Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1153A Coax - CATV Cable For more Information please call 1-800-Belden1 General Description: 14 AWG solid .064" bare copper-covered steel conductor, plenum, foam FEP insulation, Duofoil(R) (100% coverage) + TC braid shields (60% and 40% coverage), FEP jacket. Physical Characteristics (Overall) Conductor AWG: # Coax AWG Stranding Conductor Material 1 14 Solid Dia. (mm) BCCS - Bare Copper Covered Steel 1.6256 Total Number of Conductors: 1 Insulation Insulation Material: Insulation Trade Name Insulation Material Teflon(R) Dia. (mm) FFEP - Foam Fluorinated Ethylene Propylene 7.112 Outer Shield Outer Shield Material: Layer # Outer Shield Trade Name Type Outer Shield Material 1 Duofoil(R) 2 3 Coverage (%) Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100 Braid TC - Tinned Copper Duofoil(R) 60 Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100 4 Braid TC - Tinned Copper 40 Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Teflon(R) FEP - Fluorinated Ethylene Propylene Overall Cable Overall Nominal Diameter: 9.830 mm Mechanical Characteristics (Overall) Operating Temperature Range: -70C To +200C Non-UL Temperature Rating: 200C Bulk Cable Weight: 145.844 Kg/Km Max. Recommended Pulling Tension: 1049.775 N Min. Bend Radius/Minor Axis: 101.600 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP, CL2P CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1153A Coax - CATV Cable EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Series Type: Series 11 Flame Test UL Flame Test: NFPA 262 CSA Flame Test: FT6 Plenum/Non-Plenum Plenum (Y/N): Yes Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 75 Nom. Inductance: Inductance (H/m) 0.305133 Nom. Capacitance Conductor to Shield: Capacitance (pF/m) 53.1522 Nominal Velocity of Propagation: VP (%) 82 Nominal Delay: Delay (ns/m) 4.06844 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 36.091 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 5.9058 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100m) 1 0.6562 10 1.27959 50 3.9372 100 5.5777 200 8.2025 400 11.4835 700 15.0926 900 17.3893 1000 18.3736 Max. Operating Voltage - UL: Voltage 300 V RMS Minimum Structural Return Loss: Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Min. SRL (dB) Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1153A Coax - CATV Cable 5 400 20 Notes (Overall) Notes: Sweep tested 5 MHz to 400 MHz. For use in indoor plenum environments but also suitable for outdoor and underground applications. Teflon(R) is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 1153A A8R1000 305 MT 48.081 KG BEIGE, SNOW C #14 FFEP DBL SH FEP 1153A A8R500 152 MT 23.814 KG BEIGE, SNOW C #14 FFEP DBL SH FEP Notes: C = CRATE REEL PUT-UP. Revision Number: 1 Revision Date: 08-21-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013