EKMC series ((PaP|Rs))) motion sensor EKMC (VZ)ceries OEconomy type suitable for a wide range of applications Recommended applications Lt] Lighting control, lighting equipment, heaters, (Gass detection (tors distance detection ) ventilators or air conditioners t t . . , co oo security equipment for IP cameras, intrusion alarms, digital signage, vending machines, = multi-function printers, display panels for meeting rooms, PCs = Lensless type available Wall installation 170UA type: EKMC 1600100 type I Specifications EKMC1601111 EKMC1601112 EKMC1601113 EKMC1603111 EKMC1603112 EKMC1603113 EKMC1604111 EKMC1604112 EKMC1604113 White Black Pearl white White Black Pearl white White Black Pearl white Standard detection type 13. Long distance detection type 64 170uA Digital 92 2 1 " Wall installation type WOrdering information EKMC16 |i IL @PaPIRs motion sensor ee 2 @Lens color 0: Lensless / 1: White / 12m (ist step lens) 6m (2nd step lens) 3M (3rd step lens) 40 68 @Detection(Lens) 2: Black / 3: Pearl white 00: Lensless / 01: 5m distance standard / @Lens 03: 12m long distance / 04: Wall installation type 0: Lensless / 1: with lens | Characteristics | Timing chart MiMaximum rated values ON evan} | Value Power supply | OFF Power supply voltage -0.3 to 7V Ambient temperature | -20 to +60 (no frost, no condensation) Storage temperature -20 to +70C Present! to _ WElectrical characteristics Absent _! Teta Piel EKMC (VZ) type | Conditions boi 1 Operating Max 6.0V _ ON moo rot voltage Min Vdd 3.0V Output voltage | j Ambient temperature: 25C OFF Current consumption x 1 1 {in standby mode) Note 1) Ave | Iw 170HA ey 1 Twu 1 > Output current Ambient temperature: 250 (during detection) Note 2) -Je 100MA Vout2Vdd-0.5 {Explanation of the timing) Output volt Ambient t + 950 Twu: pireult stapiy ume: max. 30 sec defined (ON/OFF) and a lutput voltage . . mbient temperature: uring this stage, the output's status is unde! and detection [during detection period) Min | Vout Vdd-0.5 Open at no detection is therefore not guaranteed. Circuit stability time Ambient temperature: 25C (when voltage is applied] coe) Twu 30 sec au Note 1) Current consumption during detection period is the total value of current consumption in standby mode add to output current. Note 2) Please select an output resistors (pull-down concept) in accordance with Vout so that the output current is lower than or equal to 100A. If the output current is more than 100A, this may cause false alarms.Lenses for the EKMB/EKMC series [ Dimension if Detection zone if Detection characteristics ] Standard 5m detection type j sm oo oa) om Bo Detection Max. 5m CAD data HaSeaq 5 rm o anceecE views 94x82" rs eases a Detection 7 oo aie oo roe oaeun 6m Detection | -The temperature difference jaa) X-Y Cross Section condition between the target and the > surroundings must be higher < than 4. rn | 1 | -Movement speed: 1.0m/s Target concept: Human body with an approx. size of 700X250mm pea \Cross]seclional Target moving direction: Crossing the detection beam. Long distance detection type Detection CAD data distance Max. 12m tH Field of 99" = ia 102x92 Detection 92 beams oO > Detection | -The temperature difference < condition between the target and the iw surroundings must be higher than 4. *Movement speed: 1.0m/s Target concept: Human body with an approx. size of 700X250mm Target moving direction: Crossing the detection beam. A-A Cross sectional eo om = Wall installation Detection | 1st step lens Max. 12m i distance Mo 2nd step lens Max. 6m A & ist step CAD data na oo bene step 3rd step lens Max. 3m >| % 2 oe ee 3rd step Field of 40X105 14.9m view X-Y Cross Section Detection _ a 68 beams SIDE VIEW Detection | -The temperature difference condition between the target and the surroundings must be higher than 4. *Movement speed: 1.0m/s Target concept: Human body with an approx. size of \ 700X250mm Target moving direction: Crossing the detection beam. TOP VIEW A-A Cross sectional MPIR element Lensless type (=)20 a 3.0 0.4mm Detection Average: 5.6uW/cmi t + itivit 3834 oo i i ann Maximum: 7.6uW/cni Iso ELEMENT i 7 0.6mm} {0.6mm * Detection sensitivity is measured by following system 0.4mm 8.4 9.3 | | MiTest setup 90.45 2095 | 55 t ples body Aperture Masking 3.2mm plate PaPIRs Le <0 VDD 20605 |Dcsv SOUT 340mm Reseed sot Chopper (1Hz) (@WEEED CAD data can be downloaded from the ((PaPlRs)) PaPIRs WEB site. Please refer to the formal specification for the dimension, and the tolerance *Please note that the horizontal and vertical field of view depends on the position of the metal tab on which the lens is mounted. 8((PaPIRs))) motion sensor Horizontally wide detection type > Worlds first PIR with Approach Sensing technology Panasonic presents the worlds first PIR sensor in the shape of ahammerhead with a special optic, which is more sensitive to radial motion. | | a Wall switches, thermostats, IP cameras, wake-up switch for displays, intrusion | | | | | | alarm sensors (e.g. for windows and doors), door intercom systems, entrance and garden lamps, automatic door systems, vending machines 150 degree sensing FOV Horizontally wide detection type Current consumption ) ) > in standby mode 1pA 2uaA 6A 170A (1yA type: in sleep mode) ) ) > Output Digital (open collector) White EKMB1105111 EKMB1205111 EKMB1305111K EKMC1605111 > Lens color Black EKMB1105112 EKMB1205112 EKMB1305112K EKMC1605112 Pearl white EKMB1105113 EKMB1205113 EKMB1305113K EKMC1605113 ( Dimension ) [ Detection zone ] [ Detection characteristics ] CAD data by request Detection i distance ea LIS ol Field of AreaA 122 x 35 ge Ss view Area B 150 x 20 Ss |s"|2 Detection | Area A 88 zone Area B 16 Detection | AreaA + The temperature condition A difference between the target and the surroundings must be +r higher than 4C. 3 Imesu + Movement speed: 1m/s S + Target concept: human head with an approx. size of 700x250mm . Target moving direction: crossing 2 detection (0.433 dia.) Detection Area A zones Area B + The temperature 5 difference between the VDD (0,197) target and the P.C.D.05.08 +0.2 25 surroundings must be (0.2 dia.) ey \ Ll (0.098) higher than 8C. + Movement speed: 1m/s | | + Target concept: human TO, ang ioe = 6 ragsing 2 detection (0.236) zones (759) 7424 A A s * Under specified detection conditions A Please refer to Cautions for use (page 18) and Basic principles(page 18, point 5), for more details SECTION A-A Gait Please contact your local sales representative for detailed specifications.((PaPIRs))) motion sensor Standard and slight motion detection type one Ya >2 functions in 1 lens High Sensitivity Centre ZONE: Optimized for detecting small movements and small objects Normal Sensitivity Outer ZONE: Optimized for detecting larger movements of larger objects Lighting control, heaters, ventilators or air conditioners, IP cameras, intrusion alarms, digital signage, vending machines, multi-function printers, display panels for meeting rooms, PCs Standard motion detection area 2.2m e ti -- ae. 1.8m Standard and slight motion detection type Slight motion 4.4m detection area Current consumption in standby mode 1pA 2uA 6pA 170pA (1yA type: in sleep mode) > Output Digital (open collector) White EKMB1193111 EKMB12931 11 EKMB1393111K EKMC 1693111 > Lens color Black EKMB1193112 EKMB1293112 EKMB1398112k EKMC 1693112 Pearl white EKMB1193113 EKMB1293113 EKMB1393113K EKMC1693113 ( Dimension | [ Detection zone | [ Detection characteristics EM Cr Detection 9 Slight motion. Standard m: distance Max. 2.2m detection area detection a Field of Slight motion 44 x 44 eae) view Standard motion 90 x 90 Detection | Slight motion 36 2m e.sty zone Standard motion 48 Detection | Slight motion | - The temperature ia) condition A difference between the Amasn) target and the surroundings must be (0.587 dia) higher than 4C. +) 70 + Movement speed: 0.5m/s A + Target concept: human head with an approx. size ns) of 200x200mm * Target moving direction: 2m e.sin Crossing 1 detection zone Standard motion | - The temperature P.D.CW5.08 +0.2 vop 2.2m 3m 0m 2m anne giference tetween the (0.2 dia) (7.2tt) (9.8it) (6.6it) (3.3it) (3.31) (6.6ft) (9.8ft) surroundings must be X-Y Cross Section (2.2m) (7.20) higher than 4C. UT Movement speed: 1.0m/s (45.3) 41.0 4).0 (45.3) + Target concept: human x%& Zo 2.2m body with an approx. size (7.2) of 400x200mm Target moving direction: crossing 2 detection zones SECTION A-A * Under specified detection conditions A Please refer to Cautions for use (page 18) and Basic principles(page 18, point 5), for more details Please contact your local sales representative for detailed specifications.