PGFI Series 15 Amp Portable Series GFCI / ELCI INTRODUCTION The LineGardTM 15 Amp In-Line Series is a ground fault circuit interrupter designed and manufactured by North Shore Safety, Ltd., a leader in innovative safety products. The 15 amp PGFI product is rated at 120 VAC and available in either manual (safe start) or automatic reset configuration. Standard offerings include products geared for maintenance repair organizations (MRO), original equipment manufacturers (OEM) or general portable power applications. MRO products are supplied with heavy-duty 12/3 conductor high flex (indoor/outdoor) safety yellow cable (SJTW type) capable of withstanding heavy trade or industrial use. OEM products are configured with robust 14/3 conductor (indoor/outdoor) black cable (SJTW type) for integration into trade related equipment. All products are industrial/trade grade tough and are backed by a 2 year manufacturer's warranty. These devices meet the requirements of OSHA 29 CFR 1926.404(b)(1) (ii) & OSHA 29 CFR 1926.405(a)(2)(ii)(G) and additionally meet the requirements of NEC 590.6(a) and (b). FEATURES * Bright LED power indicator * Recessed interface buttons reduce damage and nuisance tripping from rough service * High strength polycarbonate housing * Class A cULus 943 listed with load side connector assemblies * NEMA 3R rated (indoor / outdoor use) * Assembly is rated for 15 amps / 120 VAC * Available in automatic or manual reset configurations* * Available with single or tri-tap plug assembly * 2-year manufacturer's warranty Specifications Listing Type Rated Supply Voltage Rated Current Trip Level, Class A Operating Frequency 1 Reset Type Ground Trip Current Overload Current Insulation Voltage Endurance Operations cULus Listed Class A UL 943 CSA 22.2 No. 144 120VAC Up to 15 Amps or rating of wiring device and/or cable 5mA +/- 1mA (UL 943) 60 Hz Automatic or Manual 4 mA to 6 mA 90 Amps @ 125VAC 1,500 VRMS for 1 minute 3000 operations 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 2. Integrated or replacement cable must be indoor/outdoor 3-conductor cable of type ST, SJT, SE, SJE, SO or SJO 270 PGFI Series - 15 Amp In-Line Series http://airpax.sensata.com/ Confined Space Construction Sites Application Opportunities: (NEC 590.6) Commercial Garages (NEC 511.12) Outdoor Signs (NEC 600.10) Fountains & Water Displays (NEC 680.58) Spa & Hot Tubs (NEC 680.40) Marinas & Boat Yards Electrical wet locations Power generators Agricultural equipment Outdoor electrical equipment Cement cutting equipment Portable electric heaters Submersible pumps Pipeline heaters Automotive garages Industrial part washers Outdoor signage Vending equipment OSHA 29 CFR 1926.404 (b)(1)(ii), OSHA 29 CFR 1926.405 (a)(2)(ii)(G) (NEC 555.3) Ground Fault / Equipment Leakage RELATED CODES DECISION TABLES PGFI - M04 0 K Y - ST2 1 Product Type 6 Cable Configuration No designation No cable required (field wireable) 2 Reset Type (1) M04 Manual A04 Automatic *Note: 3 Cable Gauge 4 Cable Type No designation No cable required (field wireable) 0 12 gauge, 3 conductor 1 14 gauge (15 amp) 2 16 gauge (13 amp) 3 18 gauge (10A) 5 Connector No designation No cable required (field wireable) No designation No cable required (field wireable) K J SJTW (yellow) Y SJ00W (black) N No connector cULus 943 Listed ST2 Single-tap, 2' yellow cable TT2 Tri-tap, 2' yellow cable ST25 Single-tap, 25' yellow cable TT25 Tri-tap, 25' yellow cable ST50 Single tap, 50' yellow cable FL __ Flying leads, specify cable length in feet 1. Manual configuration should be specified if automatic power-up, after power restoration of circuit power, could create an unsafe condition. 2. Integrated or replacement cable must be indoor/outdoor 3-conductor cable of type ST, SJT, SE, SJE, SO or SJO 3. Custom cord sets are available. Please consult Airpax for other options Single Tap (SJTW) http://airpax.sensata.com/ Tri-Tap (SJTW) PGFI Series - 15 Amp In-Line Series 271 PGFI Series 20 Amp Portable Series (Cord) GFCI / ELCI INTRODUCTION The LineGardTM 20 Amp Portable Series is an industrial grade ground fault circuit interrupter designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. This product is the "Go Anywhere" protection device. Rated for 20 amps and available at 120 VAC, 240 VAC, 208 VAC, or 277 VAC (UL 1053 compliant), the device is also available with either manual (safe start) or automatic reset configuration. Standard offerings include products with plug and connector or flying leads for field configuring which can be constructed into stand-alone cord sets or equipment integrated power supply cords. The product series is well suited for wet location use with an achieved NEMA 4X rating. Note that any power cord integrated with this device becomes OSHA compliant for portable power usage in confined space: OSHA 29 CFR 1926.404(b)(1)(ii) and 29 CFR 1926.405(a)(2)(ii)(G). Additionally, this product meets the requirements of NEC 590.6(a) & (b). FEATURES * Power and fault status indicators * Electro-mechanically latched contacts will not de-latch under rough service usage * Chemical and UV resistant enclosure * Class A cULus 943 listed * NEMA 4X rated (indoor / outdoor use) * Double insulated user interface for added safety * Available in automatic or manual reset configurations* * Available with wiring devices or flying leads * 2-year manufacturer's warranty Specifications Listing Type Rated Supply Voltage Rated Current Trip Level, Class A Operating Frequency 1 Reset Type Ground Trip Current Overload Current Insulation Voltage Endurance Operations cULus Listed Class A UL 943 CSA 22.2 No. 144 120 VAC, 240 VAC, 208 VAC, 277 VAC (UL 1053 compliant) Up to 20 Amps or rating of wiring device and/or cable 5mA +/- 1mA (UL 943) 60 Hz Automatic or Manual 4 mA to 6 mA 90 Amps @ 125VAC 1,500 VRMS for 1 minute 3000 operations 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 2. Integrated or replacement cable must be indoor/outdoor 3-conductor cable of type ST, SJT, SE, SJE, SO or SJO 272 PGFI Series - 20 Amp Portable (Cord) Series http://airpax.sensata.com/ Confined Space Construction Sites Application Opportunities: (NEC 590.6) Commercial Garages (NEC 511.12) Outdoor Signs (NEC 600.10) Fountains & Water Displays (NEC 680.58) Spa & Hot Tubs (NEC 680.40) Marinas & Boat Yards Electrical wet locations Power generators Agricultural equipment Outdoor electrical equipment Cement cutting equipment Portable electric heaters Submersible pumps Pipeline heaters Automotive garages Industrial part washers Outdoor signage De-icing equipment (roof heaters) OSHA 29 CFR 1926.404 (b)(1)(ii), OSHA 29 CFR 1926.405 (a)(2)(ii)(G) (NEC 555.3) Ground Fault / Equipment Leakage RELATED CODES DECISION TABLES PGFI - 2 2 0 1 N 1 Product Type 1 6 Connector N None 1 Locking (see notes) 2 Voltage 3 Ampacity 4 Reset Type 1 120 VAC 2 0 Manual 1 2' yellow, 12/3, SJEOOW cable 2 240 VAC 1 Automatic 2 25' yellow, 12/3, SJEOOW cable 9 208 VAC 3 50' yellow, 12/3, SJEOOW cable D 277 VAC 5 6' yellow, 12/3, SJEOOW cable Note: 20 amps 5 Cable Configuration 1. Manual configuration should be specified if automatic power-up, after power restoration of circuit power, could create an unsafe condition. 2. Units are configured with SJTW cable and molded locking non-watertight connectors configured to 20 Amps. NEMA configurations for the 120 VAC and 208/240 VAC are L5-20 and L6-20 respectively. 277 VAC configurations are L7-20 3. Integrated or replacement cable must be indoor/outdoor 3-conductor cable of type ST, SJT, SE, SJE, SO or SJO 4. Custom cord sets and watertight connectors are available. Please consult Airpax NEMA and IEC 309 Connectors available http://airpax.sensata.com/ Flying Leads (SJOOW) PGFI Series - 20 Amp Portable (Cord) Series 273 PGFI Series 30 Amp Portable Series (Cord) GFCI / ELCI INTRODUCTION The LineGardTM 30 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. Available with an operating voltage of 120 VAC, 208 VAC, 240 VAC or 277 VAC (UL 1053 compliant), this product can be integrated during after-market equipment upgrades or used as a stand-alone portable cordset. All units are MADE IN THE USA and are listed per UL 943 and CSA 22.2 No.144. Note that any power cord integrated with this GFCI becomes OSHA compliant for portable power usage in confinded space: OSHA 29 CFR 1926.404 (b)(1)(ii) and OSHA 29 CFR 1926.405 (a)(2)(ii)(G). Additionally, these devices meet NEC requirement 590.6 (a) and (b). FEATURES Specifications Listing Type * Power and fault status indicators * * * * Double insulated user interface Industrial design for rough service Chemical and UV resistant enclosure cULus Listed as a Class A GFCI per UL 943 and CSA 22.2 No. 144 * 30 amp, 3-wire configurations in 120VAC, 208 VAC, 240 VAC or 277 VAC (UL 1053) * NEMA 4X and 6P wet location rated (indoor / outdoor) * Available in automatic or manual reset configurations* Rated Supply Voltage Rated Current Trip Level, Class A Operating Frequency 1 Reset Type Response Time Operating Temperature Operating Voltage Range Let-Go Voltage Open Neutral Protection2 Grounded Neutral Protection2 cULus Listed Class A UL 943 CSA 22.2 No. 144 120 VAC, 240 VAC, 208 VAC, 277 VAC (UL 1053 compliant) Up to 30 Amps or rating of wiring device and/or cable 5mA +/- 1mA (UL 943) 60 Hz Automatic or Manual 25mS max -35C to 66C 85% to 110% of rated VAC 60% of supply voltage Trips upon loss of neutral Trips if ground and neutral touch at load side 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 2. Applicable models only 274 PGFI Series - 30 Amp Portable (Cord) Series http://airpax.sensata.com/ Confined Space Construction Sites Application Opportunities: (NEC 590.6) Commercial Garages (NEC 511.12) Outdoor Signs (NEC 600.10) Fountains & Water Displays (NEC 680.58) Spa & Hot Tubs (NEC 680.40) Marinas & Boat Yards Electrical wet locations Power generators Agricultural equipment Outdoor electrical equipment Cement cutting equipment Portable electric heaters Submersible pumps Pipeline heaters Automotive garages Industrial part washers Outdoor signage De-icing equipment (roof heaters) OSHA 29 CFR 1926.404 (b)(1)(ii), OSHA 29 CFR 1926.405 (a)(2)(ii)(G) (NEC 555.3) Ground Fault / Equipment Leakage RELATED CODES DECISION TABLES PGFI - 2 3 0 1 N 1 Product Type 1 6 Connector N None 1 Locking 2 Voltage 3 Ampacity 4 Reset Type 1 120 VAC 3 0 Manual 1 2' yellow, 10/3, SJEOOW cable 2 240 VAC 1 Automatic 2 25' yellow, 10/3, SJEOOW cable 9 208 VAC 3 50' yellow, 10/3, SJEOOW cable D 277 VAC 5 6' yellow, 10/3, SJEOOW cable Note: 30 amps (see notes) 5 Cable Configuration 1. Manual configuration should be specified if automatic power-up, after power restoration of circuit power, could create an unsafe condition. 2. Units are configured with SJTW cable and molded locking non-watertight connectors configured to 30 Amps. 3. Custom cord sets are available. Please consult Airpax for other options NEMA and IEC 309 Connectors available http://airpax.sensata.com/ PGFI Series - 30 Amp Portable (Cord) Series 275 PGFI Series 30 Amp Multi-Phase Portable Series (Cord) GFCI / ELCI INTRODUCTION The LineGardTM 30 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. Available with an operating voltage of 120/240 VAC, 3O 120/208 VAC, 3O 240 VAC (certified to CSA 22.2 only) or 3O 208 VAC, 3O 277 VAC (UL 1053 compliant). This product can be integrated during after-market equipment upgrades or used as a stand-alone portable cordset. All units are MADE IN THE USA and are listed per UL 943 and CSA 22.2 No.144. Note that any power cord integrated with this GFCI becomes OSHA compliant for portable power usage in confinded space: OSHA 29 CFR 1926.404 (b)(1)(ii) and OSHA 29 CFR 1926.405 (a)(2)(ii)(G). Additionally, these devices meet NEC requirement 590.6 (a) and (b). FEATURES Specifications Listing Type * Power and fault status indicators * * * * Double insulated user interface Industrial design for rough service Chemical and UV resistant enclosure cULus Listed as a Class A GFCI per UL 943 and CSA 22.2 No. 144 * 30 amp configurations in 120/240 VAC 4-wire, 3O 120/208 VAC 5-wire, 3O 240 VAC 4-wire, 3O 208 VAC 4-wire, 3O 277 VAC 4-wire (UL 1053) Rated Supply Voltage 120/240 VAC, 3O 120/208 VAC, 3O 240 VAC (CSA only), 3O 208 VAC, 3O 277 VAC (UL 1053) Rated Current Up to 30 Amps or rating of wiring device and/or cable Horse Power 1HP @ 120 VAC, 3HP @ 240 VAC Trip Level, Class A * NEMA 4X and 6P wet location rated (indoor / outdoor) * Available in automatic or manual reset configurations* cULus Listed Class A UL 943, UL 1053 CSA 22.2 No. 144 Phase Operating Frequency Reset Type1 Response Time Operating Temperature Operating Voltage Range Let-Go Voltage Open Neutral Protection Grounded Neutral Protection 5mA +/- 1mA Dual voltage and 3 phase 60 Hz Automatic or Manual 25mS max -35C to 66C 85% to 110% of rated VAC 60% of supply voltage Trips upon loss of neutral Trips if ground and neutral touch at load side 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 276 PGFI Series - 30 Amp Multi-Phase Portable (Cord) Series http://airpax.sensata.com/ Confined Space Construction Sites Application Opportunities: (NEC 590.6) Commercial Garages (NEC 511.12) Outdoor Signs (NEC 600.10) Fountains & Water Displays (NEC 680.58) Spa & Hot Tubs (NEC 680.40) Marinas & Boat Yards Electrical wet locations Power generators Agricultural equipment Outdoor electrical equipment Cement cutting equipment Portable electric heaters Submersible pumps Pipeline heaters Automotive garages Industrial part washers Outdoor signage De-icing equipment (roof heaters) OSHA 29 CFR 1926.404 (b)(1)(ii), OSHA 29 CFR 1926.405 (a)(2)(ii)(G) (NEC 555.3) Ground Fault / Equipment Leakage RELATED CODES DECISION TABLES PGFI - 4 3 0 9 N 1 Product Type 6 Connector N 1 2 2 Voltage 3 Ampacity 4 Reset Type C 120/240 VAC split O 3 0 Manual A 2' black, 10/4 SEOOW cable 1 Automatic 9 25' black, 10/4 SEOOW cable C 50' black, 10/4 SEOOW cable 30 amps 4 120/208 VAC 3O 7 240 VAC 3O 5 Cable Configuration None 8 208 VAC 3O B 277 VAC 3O *Note: 1. Manual configuration should be specified if automatic power-up, after power restoration of circuit power, could create an unsafe condition. 2. 120/208 VAC 3O configurations use 10/5 SEOOW cable Flying Leads (SEOOW) http://airpax.sensata.com/ PGFI Series - 30 Amp Multi-Phase Portable (Cord) Series 277 PGFI Series 40, 50 & 60 Amp Portable Series (Cord) ELCI INTRODUCTION The LineGardTM 40, 50 and 60 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. These devices are designed for industrial and trade applications such as welders, pumps, motors and generators and come standard with selectable key switching for fault level threshold, power on and reset type (automatic vs. manual) settings. As configured the device has three fault threshold settings of 6mA, 10mA and 30mA, with all engineered trip times of 25mS or less. These units come standard with a 6' primary cord and a 6' secondary cord length with flying leads for field configuring. Integrated NEMA or IEC 309 wiring devices are also available as factory customs. The enclosure is configured with floor mount feet but is additionally supplied with wall or surface mounted feet for more permanent installations. All units are MADE IN THE USA and are UL 1053 Compliant. FEATURES Specifications Rated Supply Voltage * Power and fault status indicators Rated Current * * * * Double insulated user interface UL1053 compliant Chemical and UV resistant enclosure 40, 50 and 60 amp configurations in 1O 120 VAC, 1O 240 VAC, 1O 208 VAC, 1O 277 VAC, 120/240 VAC, 3O 240 VAC, 3O 208 VAC, 3O 277 (Available with or without neutral), 3O 480 VAC, 3O 600 VAC * Fault level key switch - max. trip threshold 6mA, 10mA, and 30mA * Surge protection optional * NEMA 4X wet location rated (indoor / outdoor) Field selectable threshold @ 6mA, 10mA and 30mA Phase Single, dual and three phase 1 Reset Type Response Time Operating Temperature Operating Voltage Range * Automatic or manual reset key switch 40 thru 60 Amps or rating of wiring device and/or cable Trip Level Operating Frequency 1 120 VAC 1O to 600 VAC 3O Let-Go Voltage Open Neutral Protection Grounded Neutral Protection 60 Hz Automatic or Manual 25mS max -35C to 66C 85% to 110% of rated VAC 60% of supply voltage Trips upon loss of neutral Trips if ground and neutral touch at load side 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 278 PGFI Series - 40, 50, 60 Amp Portable (Cord) Series http://airpax.sensata.com/ Confined Space Construction Sites Application Opportunities: (NEC 590.6) Commercial Garages (NEC 511.12) Outdoor Signs (NEC 600.10) Fountains & Water Displays (NEC 680.58) Spa & Hot Tubs (NEC 680.40) Marinas & Boat Yards Electrical wet locations Power generators Agricultural equipment Outdoor electrical equipment Cement cutting equipment Portable electric heaters Submersible pumps Pipeline heaters Automotive garages Industrial part washers Outdoor signage De-icing equipment (roof heaters) OSHA 29 CFR 1926.404 (b)(1)(ii), OSHA 29 CFR 1926.405 (a)(2)(ii)(G) (NEC 555.3) Ground Fault / Equipment Leakage RELATED CODES DECISION TABLES PGFI - 1 5 4 5 N 1 Product Type 2 Voltage 6 Connectors N Flying leads 3 Ampacity 4 Power-up 5 Secondary cord 4 5 6' Black, SEOOW 1 120 VAC 1O 2 240 VAC 1O 4 40 amps 5 480 VAC 3O 6 600 VAC 3O 5 50 amps 7 240 VAC 3O 8 208 VAC 3O 6 60 amps 9 208 VAC 1O B 277 VAC 3O C 120/240 VAC D 277 VAC 1O Key Switch Auto / Manual Contact Sensata for custom integrated connectors http://airpax.sensata.com/ PGFI Series - 40, 50, 60 Amp Portable (Cord) Series 279