Schottky Powermod FST15380 - FST153100 N 4-PLCS. A Dim. Inches 1 2 3 Common Cathode C E 1 2 3 L P 1.200 9 Pins eq at .150 F G H K 1 2 3 A=Common Anode J 1 2 3 D=Doubler Notes: Baseplate: Nickel plated copper; electrically isolated Pins: Nickel plated copper M Microsemi Catalog Number Industry Part Number FST15380* FST15390* FST153100* 153CMQ080 Minimum Maximum Minimum Maximum Notes A C E F G H J K L M N P 1.995 0.495 0.990 2.390 1.490 0.120 --0.240 0.490 0.040 0.175 0.032 153CMQ100 2.005 0.506 1.010 2.410 1.510 0.130 0.400 0.260 0.510 .050 0.195 0.052 50.67 12.57 25.15 60.71 37.85 3.05 --6.10 12.45 1.02 4.45 0.81 50.93 12.83 25.65 61.21 38.35 3.30 10.16 6.60to Lead CL 12.95 Square 1.27 Dia 4.95 1.32 Schottky barrier rectifier Working Peak Repetitive Peak Reverse Voltage Reverse Voltage 80V 90V 100V Millimeter Guard ring for reverse protection V RRM - 80 to 100 Volts 80V 90V 100V High surge capacity Reverse energy tested Electrically isolated baseplate ROHS Compliant *Add the Suffix A for Common Anode, D for Doubler Electrical Characteristics IF(AV) 150 Amps Average forward current per pkg IF(AV) 75 Amps Average forward current per leg IFSM 1200 Amps Maximum surge current per leg Max repetitive peak reverse current per leg IR(OV) 2 Amps VFM .72 Volts Max peak forward voltage per leg VFM .94 Volts Max peak forward voltage per leg IRM 20 mA Max peak reverse current per leg IRM 1.5 mA Max peak reverse current per leg CJ Typical junction capacitance per leg 1500 pF TC = 120C, Square wave, R 0JC = 0.5C/W TC = 120C, Square wave, R 0JC = 1.0C/W 8.3 ms, half sine T J = 175C f = 1 KHz, 25C, 1sec Square wave I FM = 75A: T J = 125C* I FM = 75A: T J = 25C * VRRM, T J = 125C * VRRM, T J = 25C VR = 5.0V, T J = 25C *Pulse test: Pulse width 300sec, Duty cycle 2% Thermal and Mechanical Characteristics Storage temp range Operating junction temp range Maximum thermal resistance per leg Maximum thermal resistance per pkg Typical thermal resistance (greased) Mounting torque Weight T STG TJ R OJC R OJC R OCS -55C to 175C -55C to 175C 1.0C/W Junction to case 0.5C/W Junction to case 0.1C/W Case to sink 15 - 20 inch pounds maximum 2.5 ounces (71 grams) typical www.microsemi.com October, 2012 - Rev. 3 FST15380 - FST153100 Figure 1 Typical Forward Characteristics - Per Leg Figure 3 Typical Junction Capacitance - Per Leg 1000 10000 800 6000 125 C 4000 25 C Junction Capacitance - pF 600 400 200 100 80 2000 1000 60 600 400 200 100 0.1 40 5.0 1.0 10 50 100 Figure 4 Forward Current Derating - Per Leg Maximum Allowable Case Temperature - C Instantaneous Forward Current - Amperes 0.5 Reverse Voltage - Volts 20 10 8.0 6.0 4.0 2.0 1.0 0 .3 .5 .7 .9 1.1 1.3 1.5 Instantaneous Forward Voltage - Volts 175 165 155 145 135 125 115 105 90 0 10 20 30 40 50 DC 120 180 60 70 80 90 Average Forward Current - Amperes Figure 2 Typical Reverse Characteristics - Per Leg Typical Reverse Current - mA 100 10 175 C 1.0 125 C 0.1 .01 .001 75 C 25 C 0 20 40 60 80 100 Reverse Voltage - Volts www.microsemi.com October, 2012 - Rev. 3 100 DISCLAIMER The information contained in the document (unless it is publicly available on the Web without access restrictions) is PROPRIETARY AND CONFIDENTIAL information of Microsemi and cannot be copied, published, uploaded, posted, transmitted, distributed or disclosed or used without the express duly signed written consent of Microsemi. If the recipient of this document has entered into a disclosure agreement with Microsemi, then the terms of such Agreement will also apply. This document and the information contained herein may not be modified, by any person other than authorized personnel of Microsemi. No license under any patent, copyright, trade secret or other intellectual property right is granted to or conferred upon you by disclosure or delivery of the information, either expressly, by implication, inducement, estoppels or otherwise. Any license under such intellectual property rights must be approved by Microsemi in writing signed by an officer of Microsemi. Microsemi reserves the right to change the configuration, functionality and performance of its products at anytime without any notice. This product has been subject to limited testing and should not be used in conjunction with lifesupport or other mission-critical equipment or applications. Microsemi assumes no liability whatsoever, and Microsemi disclaims any express or implied warranty, relating to sale and/or use of Microsemi products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Any performance specifications believed to be reliable but are not verified and customer or user must conduct and complete all performance and other testing of this product as well as any user or customers final application. User or customer shall not rely on any data and performance specifications or parameters provided by Microsemi. It is the customer's and user's responsibility to independently determine suitability of any Microsemi product and to test and verify the same. The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the entire risk associated with such information is entirely with the User. Microsemi specifically disclaims any liability of any kind including for consequential, incidental and punitive damages as well as lost profit. The product is subject to other terms and conditions which can be located on the web at http://www.microsemi.com/legal/tnc.asp Life Support Application Seller's Products are not designed, intended, or authorized for use as components in systems intended for space, aviation, surgical implant into the body, in other applications intended to support or sustain life, or for any other application in which the failure of the Seller's Product could create a situation where personal injury, death or property damage or loss may occur (collectively "Life Support Applications"). Buyer agrees not to use Products in any Life Support Applications and to the extent it does it shall conduct extensive testing of the Product in such applications and further agrees to indemnify and hold Seller, and its officers, employees, subsidiaries, affiliates, agents, sales representatives and distributors harmless against all claims, costs, damages and expenses, and attorneys' fees and costs arising, directly or directly, out of any claims of personal injury, death, damage or otherwise associated with the use of the goods in Life Support Applications, even if such claim includes allegations that Seller was negligent regarding the design or manufacture of the goods. Buyer must notify Seller in writing before using Seller's Products in Life Support Applications. Seller will study with Buyer alternative solutions to meet Buyer application specification based on Sellers sales conditions applicable for the new proposed specific part. www.microsemi.com October, 2012