ROHS Compliant
Schottky Powermod
Pins: Nickel plated copper
Baseplate: Nickel plated copper;
Repetitive Peak
Reverse Voltage
FST15380 - FST153100
*Add the Suffix A for Common Anode, D for Doubler
75 Amps
150 Amps
2 Amps
.72 Volts
1.5 mA
20 mA
1500 pF
.94 Volts
1200 Amps
*Pulse test: Pulse width 300µsec, Duty cycle 2%
Thermal and Mechanical Characteristics
Electrical Characteristics
JC
R
O
Maximum thermal resistance per pkg
Mounting torque
Typical thermal resistance (greased)
Weight
R
CS
O
Average forward current per leg
Max peak reverse current per leg
Max peak forward voltage per leg
Max repetitive peak reverse current per leg
Typical junction capacitance per leg
Max peak reverse current per leg
Max peak forward voltage per leg
Maximum surge current per leg
Average forward current per pkg
Maximum thermal resistance per leg
Operating junction temp range
Storage temp range
I
RM
T
R
T
STG
JC
O
J
RM
C
I
J
I
F(AV)
R(OV)
F(AV)
I
V
V
I
I
FM
FM
FSM
C
H
80V
90V
100V
Working Peak
Reverse Voltage
FST153100*
FST15380*
Catalog Number
Microsemi
1.200
F
G
9 Pins eq at .150
J
electrically isolated
80V
90V
100V
Notes:
K
A
E
N 4-PLCS.
C = 120°C, Square wave, 0JC = 1.0°C/W
C = 120°C, Square wave, 0JC = 0.5°C/W
0.5°C/W
Junction to case
Case to sink
15 - 20 inch pounds maximum
2.5 ounces (71 grams) typical
0.1°C/W
T
FM = 75A: J = 25°C
FM = 75A: J = 125°C
RRM, J = 25°C
R = 5.0V, J = 25°C
RRM, J = 125°C
f = 1 KHz, 25°C, 1µsec Square wave
8.3 ms, half sine J = 175°C
-55°C to 175°C
-55°C to 175°C
Junction to case
T
V
1.0°C/W
V
V
T
T
I
I
T
*
T
T
**
T
R
R
Minimum Maximum Minimum Maximum Notes
to Lead C
Square
50.9350.672.005
A
1.995
0.506
2.410
1.510
0.400
0.510
0.260
0.130
0.195
0.052
1.010
P
N
L
M
K
M
F
H
J
G
E
C
0.490
0.240
0.040
0.032
0.175
0.495
2.390
1.490
0.120
---
0.990
12.57
60.71
---
12.45
6.10
3.05
37.85
1.02
4.45
0.81
25.15
.050
6.60
12.95
4.95
1.32
1.27
12.83
61.21
38.35
10.16
3.30
25.65
Dim. Inches
Millimeter
Dia
L
P
L
D=Doubler
A=Common Anode
Common Cathode
1
2
1
2
1
2
3
3
3
1
2 3
153CMQ080
153CMQ100
Industry
Part Number
FST15390*
Schottky barrier rectifier
V
Guard ring for reverse protection
RRM - 80 to 100 Volts
High surge capacity
Reverse energy tested
Electrically isolated baseplate
October, 2012 - Rev. 3
www.microsemi.com
FST15380 - FST153100
Instantaneous Forward Current - Amperes
Typical Reverse Current - mA
Reverse Voltage - Volts
0
75 C
25 C
.001
.01
20 40 8060
100
Instantaneous Forward Voltage - Volts
Typical Reverse Characteristics - Per Leg
10
175 C
125 C
0.1
1.0
100
Figure 2
0
1.0
.3
2.0
4.0
.5 .7 .9
1.1
1.3 1.5
600
125 C
60
6.0
8.0
10
20
40
200
100
80
400
25 C
Typical Forward Characteristics - Per Leg
Figure 1
800
1000
100
Reverse Voltage - Volts
0.1
0.5
1.0
600
Junction Capacitance - pF
200
100
400
4000
2000
1000
10
5.0
50
Typical Junction Capacitance - Per Leg
10000
6000
Figure 3
145
Maximum Allowable Case Temperature - C
100
Average Forward Current - Amperes
105
0
115
125
135
20
10
30 40 50
90
60
120
70 80
180
90
DC
Forward Current Derating - Per Leg
175
155
165
Figure 4
October, 2012 - Rev. 3
www.microsemi.com
www.microsemi.com October, 2012
DISCLAIMER
The information contained in the document (unless it is publicly available on the Web without access restrictions) is
PROPRIETARY AND CONFIDENTIAL information of Microsemi and cannot be copied, published, uploaded, posted,
transmitted, distributed or disclosed or used without the express duly signed written consent of Microsemi. If the
recipient of this document has entered into a disclosure agreement with Microsemi, then the terms of such Agreement
will also apply. This document and the information contained herein may not be modified, by any person other than
authorized personnel of Microsemi. No license under any patent, copyright, trade secret or other intellectual property
right is granted to or conferred upon you by disclosure or delivery of the information, either expressly, by implication,
inducement, estoppels or otherwise. Any license under such intellectual property rights must be approved by
Microsemi in writing signed by an officer of Microsemi.
Microsemi reserves the right to change the configuration, functionality and performance of its products at anytime
without any notice. This product has been subject to limited testing and should not be used in conjunction with life-
support or other mission-critical equipment or applications. Microsemi assumes no liability whatsoever, and Microsemi
disclaims any express or implied warranty, relating to sale and/or use of Microsemi products including liability or
warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other
intellectual property right. Any performance specifications believed to be reliable but are not verified and customer or
user must conduct and complete all performance and other testing of this product as well as any user or customers final
application. User or customer shall not rely on any data and performance specifications or parameters provided by
Microsemi. It is the customer’s and user’s responsibility to independently determine suitability of any Microsemi
product and to test and verify the same. The information contained herein is provided “AS IS, WHERE IS” and with all
faults, and the entire risk associated with such information is entirely with the User. Microsemi specifically disclaims
any liability of any kind including for consequential, incidental and punitive damages as well as lost profit. The product
is subject to other terms and conditions which can be located on the web at http://www.microsemi.com/legal/tnc.asp
Life Support Application
Seller's Products are not designed, intended, or authorized for use as components in systems intended for space,
aviation, surgical implant into the body, in other applications intended to support or sustain life, or for any other
application in which the failure of the Seller's Product could create a situation where personal injury, death or property
damage or loss may occur (collectively "Life Support Applications").
Buyer agrees not to use Products in any Life Support Applications and to the extent it does it shall conduct extensive
testing of the Product in such applications and further agrees to indemnify and hold Seller, and its officers, employees,
subsidiaries, affiliates, agents, sales representatives and distributors harmless against all claims, costs, damages and
expenses, and attorneys' fees and costs arising, directly or directly, out of any claims of personal injury, death, damage
or otherwise associated with the use of the goods in Life Support Applications, even if such claim includes allegations
that Seller was negligent regarding the design or manufacture of the goods.
Buyer must notify Seller in writing before using Seller’s Products in Life Support Applications. Seller will study with
Buyer alternative solutions to meet Buyer application specification based on Sellers sales conditions applicable for the
new proposed specific part.