Technical Data 4395
Effective May 2017
Supersedes July 2011
Product features
Agency information
•UL Listed, Guide JDYX, File E19180, 63mA-6.3A
•UL Recognized Card: (7A-10A) Guide JDYX2, File E19180
•CSA Certified, Class 1422-01, File E65063, 63mA-6.3A
•MITI Approval, 1A-10A
•KC-Mark: Certificate SU05011-4001 (63mA~250mA);
SU05011-4002 (300mA~800mA); SU05011-4003 (1A~3.15A);
SU05011-4004 (3.5A~6.3A)
Ordering
•Specify packaging code prefix, product number and option
code suffix
•For RoHS compliant version (suffix “-R”), drop mA or A from
product code (e.g., GMC-2-R)
GMC
5 mm x 20 mm Medium time-delay glass tube fuses
•Medium time-delay, low breaking capacity
•Available with optional axial leads
•5 mm x 20 mm physical size
•Glass tube, nickel-plated brass endcap construction
•Designed to UL/CSA 248-14
Pb
HALOGEN
HF
FREE
Electrical Characteristics
Rated Current % of Amp Rating Opening Time
100% None
63mA - 10A 135% 60 minutes maximum
200% 2 minutes maximum
Voltage Typical DC Cold Typical Maximum
Product Rating Interrupting Rating (Amps)* Resistance Pre-Arc I2t Voltage
Number Vac 250Vac 125Vac (Ω)** AC†Drop (mV)‡
GMC-63mA 250 35 10,000 10.350 0.0027 1400
GMC-80mA 250 35 10,000 - 0.0050 1400
GMC-100mA 250 35 10,000 4.775 0.0094 1200
GMC-125mA 250 35 10,000 3.400 0.014 1000
GMC-150mA 250 35 10,000 2.555 0.022 800
GMC-160mA 250 35 10,000 2.295 0.022 730
GMC-200mA 250 35 10,000 1.395 0.032 650
GMC-250mA 250 35 10,000 0.965 0.046 490
GMC-300mA 250 35 10,000 0.838 0.081 580
GMC-315mA 250 35 10,000 0.685 0.081 480
GMC-400mA 250 35 10,000 0.615 0.18 510
GMC-500mA 250 35 10,000 0.335 0.41 370
GMC-600mA 250 35 10,000 0.282 0.60 360
GMC-630mA 250 35 10,000 0.246 0.66 360
GMC-700mA 250 35 10,000 0.213 0.85 340
GMC-750mA 250 35 10,000 0.213 0.85 320
GMC-800mA 250 35 10,000 0.180 0.85 290
GMC-1A 250 35 10,000 0.156 1.8 250
GMC-1.25A 250 100 10,000 0.098 3.4 200
GMC-1.5A 250 100 10,000 0.076 5.4 190
GMC-1.6A 250 100 10,000 0.067 5.8 160
GMC-2A 250 100 10,000 0.043 8.9 130
GMC-2.5A 250 100 10,000 0.035 13 130
GMC-3A 250 100 10,000 0.026 19 130
GMC-3.15A 250 100 10,000 0.025 23 130
GMC-3.5A 125 - 10,000 0.022 25 130
GMC-4A 125 - 10,000 0.019 36 120
GMC-5A 125 - 10,000 0.014 58 120
GMC-6A 125 - 10,000 0.013 88 120
GMC-6.3A 125 - 10,000 0.012 110 120
GMC-7A 125 - 200 0.012 150 120
GMC-8A 125 - 200 0.009 200 110
GMC-10A 125 - 200 0.007 300 110
* Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC.The interrupting ratings for 7A - 10A were measured at 100% power factor on AC.
** DC Cold Resistance (Measured at <10% of rated current)
†
Typical Pre-Archin
2
tg ( II
2
t was measured at listed interrupting rating and rated voltage)
Maximum Voltage drop (Voltage drop was measured at 20°C ambient temperature at rated current)
‡