Features * * * * * * * Unregulated Converters Low cost 1W converter Industry standard pinout SIP4 package 1kVDC isolation Efficiency up to 80% Wide operating temperature range -40C to +85C UL60950-1 and CAN/CSA C22.2 No. 60950-1-07 certified Description The ROE DC/DC converters are typically used in general purpose power isolation and voltage matching applications, and feature a full industrial operating temperature range of -40C to +85C without derating. DC/DC Converter ROE 1 Watt SIP4 Single Output Selection Guide Part Number nom. Input Voltage [VDC] Output Voltage [VDC] Output Current [mA] Efficiency typ. [%] max. Capacitive Load (1) [F] ROE-3.305S 3.3 5 200 79 470 ROE-0505S 5 5 200 79 470 ROE-0512S 5 12 84 80 220 ROE-0515S 5 15 66 80 220 ROE-1205S 12 5 200 80 470 ROE-1505S 15 5 200 79 470 ROE-2405S 24 5 200 80 470 Notes: Note1: Max. capacitive load is tested at nominal input voltage and full load Model Numbering E358085 ROE-__ __ S Sinlge Output lnput Voltage Output Voltage UL60950-1 certified CAN/CSA C22.2 No. 60950-1-07 certified EN60950-1 certified IEC60950-1 certified EN55032 compliant Ordering Examples: ROE-0512S = 5VDC Input Voltage, 12VDC Output Voltage, Single Output ROE-2405S = 24VDC Input Voltage, 5VDC Output Voltage, Single Output www.recom-power.com REV.: 4/2018 ECO-1 ROE DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Input Voltage Range Max. 10% Operating Frequency Range Output Ripple and Noise (2) 50kHz 20NMHz BW 80kHz 105kHz 50mVp-p 100mVp-p Notes: Note2: Measurements are made with a 100nF MLCC across output. (low ESR) ROE-05xxS ROE-xx05S 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] Efficiency vs. Load 60 50 40 30 50 40 30 0505 0512 0515 20 10 0 60 0 10 20 30 40 50 60 70 80 90 3.305 1205 1505 2405 20 10 0 100 0 10 Output Load [%] 20 30 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Values Output Accuracy 5.0% max. Line Regulation 1.2% typ. / 1.0% Vin low line to high line Load Regulation 20% to 100% load Tolerance Envelope 5Vout 12Vout and 15Vout Vin= 3.3V, 5V Vin= 12V, 15V, 24V Vnom +15% Typical Load Deviation [%] Deviation [%] +15% +5% +5% Line -1% -5% 10 50 +5% +4% Vnom Typical Load Line -2% -5% 10 100 Load Current [%] www.recom-power.com 15% max. 10% max. 50 100 Load Current [%] REV.: 4/2018 ECO-2 ROE DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) PROTECTIONS Parameter Isolation Voltage Condition I/P to O/P (3) Value tested for 1 second 1kVDC Isolation Capacitance 75pF max. Isolation Resistance 1G min. Notes: Note3: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note4: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: T1A slow blow type ENVIRONMENTAL Parameter Condition Operating Temperature Range Value without derating @free air convection (see graph) Operating Humidity -40C to +85C non-condensing 95% RH max. Vibration MIL-STD-202G MTBF (5) 20140 x 103 hours 8674 x 103 hours according to MIL-HDBK-217F; G.B. +25C +85C Notes: Note5: MTBF is referring ROE-3.305S Derating Graph 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 85 Ambient Temperature [C] SAFETY AND CERTIFICATIONS Certificate Type Report / File Number Information Technology Equipment, General Requirements for Safety E358085-A4 Information Technology Equipment, General Requirements for Safety 1602031 EAC RU-AT.49.09571 RoHs 2+ EMI Compliance Electromagnetic compatibility of multimedia equipment Emission requirements Standard UL-60950-1, 2nd Edition, 2007 CAN/CSA C22.2 No.60950-1-07, 2nd Edition, 2007 IEC60950-1:2005, 2nd Edition + A2:2013 EN60950-1:2006 + A2:2013 TP TC 004/2011 RoHS-2011/65/EU + AM-2015/863 Condition without external filter with external filter (see suggestions) Standard / Criterion EN55032, Class A EN55032, Class B continued on next page www.recom-power.com REV.: 4/2018 ECO-3 ROE DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) EMC Filtering Suggestions according to EN55032 Class A and B C2 L1 +Vin DC C1 DC -Vin +Vout -Vout C3 Component List Class B C1 L1 C2 C2 10F MLCC 100V 22H PR4532Z-220K 330pF 330pF DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting non-conductive black plastic, (UL94 V-0) epoxy, (UL94 V-0) Package Dimension (LxWxH) 11.5 x 6.0 x 10.0mm Package Weight 1.4g Dimension Drawing (mm) embossed logo Bottom View 2.54 Recommended Footprint Details 2.54 7.62 1 2 3 4 0.250.05 Top View Pin Connections Pin # Function 1 -Vin 2 +Vin 3 -Vout 4 +Vout Tolerance: xx.x= 0.50mm xx.xx=0.25mm 1 2 3 4 1.25 1.90 Marking 4.10 0.51 0.51+0.10/-0.05 www.recom-power.com 6.0 10.0 11.5 REV.: 4/2018 ECO-4 ROE DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm Packaging Quantity 42 pcs Storage Temperature Range -55C to +125C The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 4/2018 ECO-5