Modular timers 8 - 12 - 16 A Panels for electrical distribution 83 SRIES Automatic car-washes Packaging machines Pump control Industrial refrigeration Fountains FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. 83 SERIES Modular timers 12- 16A 83 SERIES 83.01 Multi-function timer range Type 83.01 - Multi-function & multi-voltage - 1 Pole Type 83.02 - Multi-function & multi-voltage - 2 Pole (timed + instantaneous options), external time setting potentiometer option Type 83.52 - Multi-function & multi-voltage - 2 Pole (timed + instantaneous options), external time setting potentiometer option, pause function option * Multi-voltage * Multi-function 83.02 83.52 * Multi-voltage * Multi-function * Timing can be regulated using ext. Potentiometer * 2 timed contacts or 1 timed + 1 * Multi-voltage * Multi-function * Timing can be regulated using ext. Potentiometer * 2 timed contacts or 1 timed + 1 instantaneous contact * 3 functions with pause option AI:On-delay DI:Interval GI:Pulse delayed SW:Symmetrical flasher (starting pulse on) BE:Off-delay with control signal CE:On- and off-delay with control signal DE:Interval with control signal on WD:Watchdog (Retriggerable interval with control signal on) AE: On-delay with control signal GE: Pulse delayed with control signal on IT: Timing step FE: Interval with control signal on and off EEa: Interval with control signal off (retriggerable) DEp: Interval with control signal on and pause signal BEp: Off-delay with control signal and pause signal SHp: "Shower" function instantaneous contact * 22.5mm wide * Eight time scales from 0.05s to 10days * High input/output isolation * Wide supply range (24...240)VAC/DC * 35mm rail (EN60715) mount * "Blade + cross" - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip * Multi-voltage versions with "PWM clever" technology * Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance against random vibrations and shock, Category 1, Class B), EN 50155 (resistance to temperature and humidity, T1 class) AI: On-delay DI: Interval GI: Pulse delayed SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on WD:Watchdog (Retriggerable interval with control signal on) Wiring diagram (without control signal) Wiring diagram (without control signal) Wiring diagram (with control signal and external potentiometer connection) Wiring diagram (with control signal) Wiring diagram (with control signal and pause signal) Wiring diagram (with control signal) Short term (10 min) + 70C For outline drawing see page 7 (1) Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A 1 CO (SPDT) 2 CO (DPDT) 2 CO (DPDT) 16/30 12/30 12/30 250/400 250/400 250/400 VA 4000 3000 3000 Rated load AC15 (230VAC) VA 750 750 750 Single phase motor rating (230VAC) kW Breaking capacity DC1: 30/110/220V A VAC Rated load AC1 Minimum switching load 0.5 0.5 0.5 16/0.3/0.12 12/0.3/0.12 12/0.3/0.12 300 (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi VAC (50/60Hz) 24...240 24...240 24...240 VDC 24...240 24...240 24...240 mW (V/mA) Standard contact material H Supply specification Nominal voltage (UN) Rated power AC/DC Operating range VA (50Hz)/W <1.5/<2 <2/<2 <2/<2 VAC 16.8...265 16.8...265 16.8...265 VDC 16.8...265 16.8...265 16.8...265 Technical data (0.05...1)s, (0.5...10)s, (0.05...1)min, (0.5...10)min, (0.05...1)h, (0.5...10)h, (0.05...1)d, (0.5...10)d V-2019,www.findernet.com Specified time range Repeatability% 1 1 1 Recovery time ms 200 200 200 Minimum control impulse ms 50 50 50 Setting accuracy-full range Electrical life at rated load in AC1 Ambient temperature range Protection category % cycles C 5 5 5 50*103 60*103 60*103 -20...+60(1) -20...+60(1) -20...+60(1) IP 20 IP 20 IP 20 Approvals (according to type) 3 83 SERIES 83 SERIES Modular timers 16A Mono-function timer range 83.11 83.21 83.41 Type 83.11 - ON-delay, multi-voltage Type 83.21 - I nterval, multi-voltage Type 83.41 -O ff-delay with control signal, multi-voltage * 1 Pole * 22.5mm wide * Eight time scales from 0.05s to 10days * Multi-voltage * High input/output isolation * Mono-function * Wide supply range (24...240)VAC/DC AI: On-delay * 35mm rail (EN60715) mount * "Blade + cross" - both flat blade and cross head * Multi-voltage * Mono-function * Multi-voltage * Mono-function DI: Interval BE: Off-delay with control signal H Short term (10 min) + 70C For outline drawing see page 7 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/ Maximum switching voltage VAC Rated load AC1 VA Rated load AC15 (230VAC) VA Single phase motor rating (230VAC) kW Breaking capacity DC1: 30/110/220V A Minimum switching load mW (V/mA) Standard contact material Supply specification VAC (50/60Hz) Nominal voltage (UN) VDC Rated power AC/DC VA (50Hz)/W Operating range VAC VDC Technical data Specified time range Repeatability% Recovery time ms Minimum control impulse ms Setting accuracy-full range % Electrical life at rated load in AC1 cycles Ambient temperature range C Protection category (1) Approvals (according to type) 4 Wiring diagram (without control signal) Wiring diagram (without control signal) Wiring diagram (with control signal) 1 CO (SPDT) 16/30 1 CO (SPDT) 16/30 1 CO (SPDT) 16/30 250/400 4000 750 0.5 16/0.3/0.12 300 (5/5) AgNi 250/400 4000 750 0.5 16/0.3/0.12 300 (5/5) AgNi 250/400 4000 750 0.5 16/0.3/0.12 300 (5/5) AgNi 24...240 24...240 <1.5/<2 16.8...265 16.8...265 24...240 24...240 <1.5/<2 16.8...265 16.8...265 24...240 24...240 <1.5/<2 16.8...265 16.8...265 (0.05...1)s, (0.5...10)s, (0.05...1)min, (0.5...10)min, (0.05...1)h, (0.5...10)h, (0.05...1)d, (0.5...10)d 1 1 1 200 200 200 -- -- 50 5 5 5 50*103 50*103 50*103 (1) (1) -20...+60 -20...+60 -20...+60(1) IP 20 IP 20 IP 20 V-2019,www.findernet.com screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip * Multi-voltage versions with "PWM clever" technology * Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance against random vibrations and shock, Category 1, Class B), EN 50155 (resistance to temperature and humidity, T1 class) 83 SERIES Modular timers 8- 16A Mono-function and multi-function timer range 83 SERIES 83.62 83.82 83.91 Type 83.62 - Power off-delay, multi-voltage, 2 Pole Type 83.82 - Star-Delta, multi-voltage, star and delta output contacts Type 83.91 - Asymmetrical flasher, multi-voltage, 1 Pole * 22.5mm wide * Time scales: Type 83.62 - 0.05s to 3 minutes Type 83.82/83.91 - 0.05s to 10days * Wide supply range (24...240)VAC / DC * 35mm rail (EN60715) mount * Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance against random vibrations and shock, Category 1, Class B), EN 50155 (resistance to temperature and humidity, T1 class) * Multi-voltage * Mono-function * 2 pole * Multi-voltage * Multi-voltage * Mono-function * Multi-function * 2 pole * Transfer time can be regulated BI: Power off-delay (True off-delay) SD: Star-delta (0.05...1)s*** LI: Asymmetrical flasher (starting pulse on) LE: Asymmetrical flasher (starting pulse on) with control signal PI: Asymmetrical flasher (starting pulse off ) PE: Asymmetrical flasher (starting pulse off ) with control signal Wiring diagram (without control signal) Wiring diagram (with control signal) * (0.05...2)s, (1...16)s, (8...70)s, (50...180)s **(0.05...1)s, (0.5...10)s, (0.05...1)min, (0.5...10)min, (0.05...1)h, (0.5...10)h, (0.05...1)d, (0.5...10)d ***0.05 s, 0.2 s, 0.3 s, 0.45 s, 0.6 s, 0.75 s, 0.85 s, 1 s Short term (10 min) + 70C For outline drawing see page 7 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/ Maximum switching voltage VAC Rated load AC1 VA Rated load AC15 (230VAC) VA Single phase motor rating (230VAC) kW Breaking capacity DC1: 30/110/220V A Minimum switching load mW (V/mA) Standard contact material Supply specification VAC (50/60Hz) Nominal voltage (UN) VDC Rated power AC/DC VA (50Hz)/W Operating range VAC VDC Technical data Specified time range Repeatability% Recovery time ms Minimum control impulse ms Setting accuracy-full range % Electrical life at rated load in AC1 cycles Ambient temperature range C Protection category V-2019,www.findernet.com (1) Wiring diagram (without control signal) Wiring diagram (without control signal) 2 CO (DPDT) 8/15 2 NO (DPST-NO) 16/30 1 CO (SPDT) 16/30 250/400 2000 400 0.3 8/0.3/0.12 300 (5/5) AgNi 250/400 4000 750 0.5 16/0.3/0.12 300 (5/5) AgNi 250/400 4000 750 0.5 16/0.3/0.12 300 (5/5) AgNi 24...240 24...220 <1.5/<2 16.8...265 16.8...242 24...240 24...240 <1.5/<2 16.8...265 16.8...265 24...240 24...240 <1.5/<2 16.8...265 16.8...265 * 1 -- 500 ms (A1 - A2) 5 100*103 -20...+60(1) IP 20 1 200 -- 5 50*103 -20...+60(1) IP 20 H ** 1 200 50 5 50*103 -20...+60(1) IP 20 Approvals (according to type) 5 83 SERIES Modular timers 16A 83 SERIES Ordering information Example: 83 series, modular timers, 1 CO (SPDT) - 16A, supply rated at (24...240)VAC/DC. 8 3 . 0 1 . 0 . 2 4 0 . 0 Series 0 0 0 Versions 0000 = Standard Type 0 = Multi-function (AI, DI, GI, SW, BE, CE, DE, WD) 1 = On-delay (AI) 2 = Interval (DI) 4 = Off-delay with control signal (BE) 5 = Multi-function (AE, GE, IT, FE, EEa, DEp, BEp, SHp) 6 = Power off-delay (True off-delay) (BI) 8 = Star-delta (SD) 9 = Asymmetrical flasher (LI, LE, PI, PE) Supply voltage 240 = (24 ... 240)VAC/DC Supply version 0 = AC (50/60Hz)/DC No. of poles 1 = 1 CO (SPDT) 2 = 2 CO (DPDT) for 83.02, 83.52 and 83.62 2 = 2 NO (DPST-NO) for 83.82 Technical data Insulation Dielectric strength between input and output circuit VAC 4000 between open contacts Insulation (1.2/50s) between input and output VAC 1000 kV 6 EMCspecifications Type of test Reference standard 83.01/02/52/11/21/41/82/91 83.62 Electrostatic discharge contact discharge EN61000-4-2 4kV 4kV air discharge EN61000-4-2 8kV 8kV (80/1000MHz) EN61000-4-3 10V/m 10V/m (1000/2700MHz) EN61000-4-3 3V/m 3V/m EN61000-4-4 7kV 6kV on control signal terminal (B1) EN61000-4-4 7kV 6kV common mode EN61000-4-5 6kV 6kV differential mode EN61000-4-5 6kV 4kV common mode EN61000-4-5 6kV 6kV differential mode EN61000-4-5 4kV 4kV Radio-frequency common mode (0.15/80MHz) EN61000-4-6 10V 10V on Supply terminals (80/230MHz) EN61000-4-6 10V 10V EN55022 class A class A Radio-frequency electromagnetic field Surges (1.2/50s) on Supply terminals on control signal terminal (B1) Radiated and conducted emission Other data Current absorption on control signal (B1) <1mA - max cable length (capacity of 10nF/100m) 150m - when applying a control signal to B1, which is different from the supply voltage at A1/A2 B1 is isolated from A1 and A2 by an opto-coupler, and can therefore be operated at a voltage other than the supply voltage. If using a control signal of between (24... 48)VDC and a supply voltage of (24...240)VAC, ensure that the signal - is connected to A2 and the + is applied to B1, and that L is applied to B1 and N to A2. Use a 10k/0.25W linear potentiometer. Maximum cable length 10 m. When using an external potentiometer, the timer automatically use its setting in place of the internal setting. Consider the voltage potential at the potentiometer to be the same as the timer supply voltage. External potentiometer for 83.02/52 Power lost to the environment Screw torque Max. wire size 6 without contact current W 1.4 with rated current W 3.2 Nm 0.8 solid cable stranded cable mm2 1x6 / 2x4 1x4 / 2x2.5 AWG 1x10 / 2x12 1x12 / 2x14 V-2019,www.findernet.com H Fast transients (burst) (5-50ns, 5 and 100kHz) on Supply terminals 83 SERIES Modular timers 16A 83 SERIES Outline drawings Type 83.01 Screw terminal Types 83.02/52 Screw terminal Type 83.11 Screw terminal Type 83.21 Screw terminal Type 83.41 Screw terminal Type 83.62 Screw terminal H Type 83.91 Screw terminal V-2019,www.findernet.com Type 83.82 Screw terminal 7 83 SERIES 83 SERIES Modular timers 16A Accessories Sheet of marker tags (CEMBRE Thermal transfer printers) for relays types 83.01/11/21/41/62/82, plastic, 48 tags, 6x12mm 060.48 Potentiometer usable as external potentiometer for type 83.02/52 10k/0.25W linear, IP 66 087.02.2 060.48 087.02.2 Z2 Z1 Functions LED* H Supply voltage NO output contact OFF Open ON Open ON Open (Timing in Progress) ON Closed Contacts Open Closed 15 - 18 25 - 28 15 - 18 25 - 28 15 - 18 25 - 28 15 - 16 25 - 26 15 - 16 25 - 26 15 - 16 25 - 26 15 - 16 25 - 26 15 - 18 25 - 28 * The LEDon type 83.62 is illuminated when supply voltage is supplied to timer. * Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1. ** 8 * With DC supply, positive polarity has to be connected to B1 terminal (according to EN60204-1). **A voltage other than the supply voltage can be applied to the control signal (B1), example: A1 - A2 = 230VAC B1 - A2 = 12VDC V-2019,www.findernet.com * 83 SERIES Modular timers 16A 83 SERIES Functions Wiring diagram U = Supply voltageS = Signal switch Multi-function without control signal Type 83.01 83.02 = Output contact (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 83.01 (GI) Pulse delayed. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5s. (SW) Symmetrical flasher (starting pulse on). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on= time off ). 83.02 *** (BE) Off-delay with control signal. Power is permanently applied to the timer. The output contacts transfer immediately on closure of the control signal (S). Opening the control signal initiates the preset delay, after which time the output contacts reset. with control signal (CE) On- and off-delay with control signal. Power is permanently applied to the timer. Closing the control signal (S) initiates the preset delay, after which time the output contacts transfer. Opening the control signal initiates the same preset delay, after which time the output contacts reset. 83.01 (DE) Interval with control signal on. Power is permanently applied to the timer. On momentary or maintained closure of control signal (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. 83.02 *** (WD) Watchdog (Retriggerable interval with control signal on). Power is permanently applied to the timer. On momentary or maintained closure of control signal (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset; subsequent closures of control signal during the delay will extend the time. If the closure of the control signal (S) is longer than the preset time (T) then the output contacts reset. ***Type 83.02: regulated using an external potentiometer (10 k - 0.25 W). H NOTE: The timing function must be set when the timer is de-energised. Or for the 83.02/52, when the contact mode selector is in the OFF position. 83.02 type Contact mode selector Functions without control signal (example: AI) Functions with control signal (example: BE) Both output contacts (15-18 and 25-28) follow the timing function Both output contacts (15-18 and 25-28) follow the timing function Both output contacts [15-18 and 25(21)-28(24)] stay permanently open Both output contacts [15-18 and 25(21)-28(24)] stay permanently open The output contact 15-18 follows the timing function The output contact 21-24 follows the power supply (U) The output contact 15-18 follows the timing function The output contact 21-24 follows the control signal (S) 2 timed contacts V-2019,www.findernet.com 1 timed + 1 instantaneous contact 9 83 SERIES Modular timers 16A 83 SERIES Functions Wiring diagram Multi-function with control signal U = Supply voltage S = Signal switch P = Pause switch Type 83.52 AE T = Output contact (AE) On-delay with control signal. Power is permanently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which times the output contacts transfer and remain so until the power is removed. (EEa) Interval with control signal off (retriggerable). Power is permanently applied to the timer. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. *** ***Regulated using an external potentiometer (10k- 0.25W). (FE) Interval with control signal on and off. Power is permanently applied to the timer. Both the opening and the closing of the Signal Switch (S) initiates the transfer of the output contacts. In both instances the contacts reset after the preset delay has elapsed. (GE) Pulse delayed with control signal on. Power is permanently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which the output contacts transfer. Reset occurs after a fixed time of 0.25s. (IT) Timing step. Closing the Signal Switch (S) the output contacts transfer and remain so, after S opening, for the duration of the preset delay, after which they reset. During the timing period it is possible to immediate open the contact with a further impulse on S. with control signal and pause signal (BEp) Off-delay with control signal and pause signal. Power is permanently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the signal switch initiates the preset delay, after which the output contacts reset. Closure of the pause switch (X1-X2) will immediately halt the timing process, but the elapsed time will be retained. The current state of the output contacts will be maintained. On opening of the pause switch, timing resumes from the retained value. (DEp) Interval with control signal on and pause signal. Power is permanently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. Closure of the pause switch (X1-X2) will immediately halt the timing process, but the elapsed time will be retained. The current state of the output contacts will be maintained. On opening of the pause switch, timing resumes from the retained value. (SHp) "Shower" function (Off-delay with control signal and pause signal). Power is permanently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the signal switch initiates the preset delay, after which the output contacts reset. Closure of the pause switch (X1-X2) will immediately halt the timing process, but the elapsed time will be retained. During the pause, the output contacts 15-18 and 25-28 will be open. On opening of the pause switch, timing resumes from the retained value and the output contacts will take the previous condition. H 83.52 type Contact mode selector Functions with control signal and pause signal (example: BEp) Function SHp Both output contacts (15-18 and 25-28) follow the timing function Both output contacts (15-18 and 25-28) follow the timing function Both output contacts [15-18 and 25(21)-28(24)] stay permanently open Both output contacts [15-18 and 25(21)-28(24)] stay permanently open The output contact 15-18 follows the timing function The output contact 21-24 follows the control signal (S) The output contact 15-18 follows the timing function. The output contact 21-24 is always open, unless during the pause, when is closed 2 timed contacts 10 V-2019,www.findernet.com 1 timed + 1 instantaneous contact 83 SERIES Modular timers 16A 83 SERIES Functions Wiring diagram U = Supply voltageS = Signal switch Mono-function without control signal (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. 83.21 (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 83.62 (BI) Power off-delay (True off-delay). Apply power to timer (minimum 500ms). Output contacts transfer immediately. Removal of power initiates the preset delay, after which time the output contacts reset. 83.82 (SD) Star-delta. Apply power to timer. The star contact ( ) closes immediately. After preset delay has elapsed the star contact ( ) resets. After a further time (settable from 0.05s to 1s) the delta contact ( ) closes and remains in that position, until reset on power off. 83.41 (BE) Off-delay with control signal. Power is permanently applied to the timer. The output contacts transfer immediately on closure of the control signal (S). Opening the control signal initiates the preset delay, after which time the output contacts reset. 83.91 (LI) Asymmetrical flasher (starting pulse on)- (Z1-Z2 open). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ON and OFF times are independently adjustable. 83.11 83.21 83.62 = Output contact Type 83.11 83.82 with control signal (S) 83.41 Asymmetrical recycler without control signal (PI) Asymmetrical flasher (starting pulse off) - (Z1-Z2 linked). Apply power to timer. Output contacts transfer after time T1 has elapsed and cycle between OFF and ON for as long as power is applied. The ON and OFF times are independently adjustable. 83.91 Z1-Z2 open: (LI) function Z1-Z2 linked: (PI) function (LE) Asymmetrical flasher (starting pulse on) with control signal (Z1-Z2 open). Power is permanently applied to the timer. Closing control signal (S) causes the output contacts to transfer immediately and cycle between ON and OFF, until opened. with control signal (PE) Asymmetrical flasher (starting pulse off) with control signal (Z1-Z2 linked). Power is permanently applied to the timer. Closing the control signal (S) initiates delay T1 after which the output contacts transfer and continue to cycle between OFF and ON, until the control signal is opened. 83.91 Z1-Z2 open: (LE) function Z1-Z2 linked: (PE) function Times scales Rotary switch position series 83 1s (0.5...10)s 1m (0.05...1)min 10 m (0.5...10)min 1h (0.05...1)h 10 h (0.5...10)h 1d (0.05...1)d 10 d (0.5...10)d V-2019,www.findernet.com (0.05...1)s 10 s Please see general technical information 11 H