2200 Series / 2600 Series General Purpose Industrial Pressure Transducers > Gauge, Absolute, Vacuum and Compound Pressure Models Available > Submersible, General Purpose and Wash Down Enclosures > High Stability Achieved by CVD Sensing Element > Millivolt, Voltage and Current Output Models The 2200 series features stability and accuracy in a variety of enclosure options. The 2600 series extends the packaging options via an all welded stainless steel back end for demanding submersible and industrial applications. The 2200 and the 2600 feature proven CVD sensing technology, an ASIC (amplified units), and modular packaging to provide a sensor line that can easily accommodate specials while not sacrificing high performance. Specifications Input Pressure Range Vacuum to 6000 psi (400 bar) Proof Pressure 2 x Full Scale (FS) (1.5 x Fs for 400 bar, > 5000 psi) Burst Pressure >85 x FS <= 100 psi (6 bar): >20 x FS >= 1000 psi (60 bar); >5 x FS <= 6000 psi (400 bar) Fatigue Life Designed for more than 100 million FS cycles Performance Long Term Drift 0.2% FS/year (non-cumulative) Accuracy 0.25 % FS typical (optional 0.15% FS) Thermal Error 1.5% FS typical (optional 1% FS) Compensated Temperatures -5F to +180F (-20C to +80C) Operating Temperatures -40F to +260F (-40C to +125C) for elec. codes A, B, C, 1 -5F to +180F (-20C to +80C) for elec. codes 2, D, G, 3 -5F to +125F (-20C to +50C) for elec. codes FM, P Amplified units >100C maximum 24 VDC supply Zero Tolerance 1% of span Span Tolerance 1% of span Response Time 0.5 ms Mechanical Configuration Pressure Port See ordering chart Wetted Parts 17-4 PH Stainless Steel Electrical Connection See ordering chart Enclosure 316 ss, 17-4 PH ss IP65 NEMA 4 for elec. codes A, B, C, D, G,1, 2,3 IP67 for elec. code F IP68 for elec. codes M, (max depth 200 meters H,0) IP30 for elec. code 3 with flying leads Vibration 70g, peak to peak sinusoidal, 5 to 2000 Hz (Random Vibration: 20 to 2000 Hz @ ~20g Peak per MIL-STD.-810E Method 514.4) Acceleration 100g steady acceleration in any direction 0.032% FS/g for 15 psi (1 bar) range decreasing logarithmically to 0.0007% FS/g for 6000 psi (400 bar) range. Shock 20g, 11 ms, per MIL-STD.-810E Method 516.4 Procedure | Approvals CE, UR (22IC, 261C, 22CS, 26CS) Weight Approx. 100 grams (additional cable; 75 g/m) Series 2200 Series 2600 2200/2600 Series / p1of4 / 3-APR-14 Visit www.GemsSensors.com for most current information. PSIBAR CVD TYPES ~ 4 a! ww a (=) ya is 4 = Label a4 va) '%,) Label (a4 a.Ge Sensors &Controls Individual Specifications Electromagnetic Capability Millivolt Output units Meets the requirement for CE marking of EN50081-2 Output 100 mV (10 mv/v) for emissions and EN50082-2 for susceptibility. Supply Valtage (Vs) 10 VDC (15 VDC max.) Regulated Test Data: Bridge resistance 2600-6000 ohms * EN61000-4-2 Electrostatic Discharge. 8kV air Voltage Output units dering chart discharge, 4kV contact discharge. Unit survived. uipu see ordering cna . pope e ENV50140 Radiated RF Susceptibility. 10V/m, 80MHz- Supply Voltage (Vs) 1.5 VDC above span to 35 VDC @ 6 mA 1GHz, 1kHz mod. Maximum recorded output error Supply Valtage Sensitivity 0.01% FS/Volt was <+1% mn oon Resistance _(Somoere * ENV50204 Radiated RF Susceptibility to Mobile 7 pp - : Telephones. 10V/m, 900MHz. Maximum recorded Current Output units output error was <+1% Output 4-20 mA (2 wire) oo ; Supply Voltage (Vs) 24 VDC, (7-35 VDC) EN61 000-4-4 Fast Burst Transient. 2kV, 5/50ns, 5kHz Supply Voltage Sensitivity 0.01% FS/Volt for 1 minute. Unit survived. Max. Loop Resistance (Vs-7) x 50 ohms ENV50141 Conducted RF Susceptibility. 10Vms, 1kHz mod, 150kHz - 80MHz. Maximum recorded output error was <+1% Connection Code mV units Voltage units Current units (4-20mA) IN+ |OUT+ J}OUT- |IN- |IN+ |COM |OUT+ |EARTH |(+) |() | EARTH Cable Legend: A,B,G DIN PIN | 1 2 3 E 1 2 3 4 1 2 4 R= Red BL = Blue C 40-6 Bayonet PIN|A B G D A C B E A B E BK = Black D cable R Y BL G R BK Ww DRAIN |R BK DRAIN W = White F IP 67 cable R ly {BL {a {rR |Bk |w- |pRAIN |R [BK [DRAIN = ellow M Immersible R Y BL Ww R Ww Y DRAIN |R BL DRAIN 1 8-4 Bayonet PIN]A B D A C B D A B D 2 cable R Ww BK R BK Ww DRAIN |R BK DRAIN 3 conduit & cable R Ww BK R BK Ww DRAIN |R BK DRAIN POWER SUPPLY ), | (+) IN (+) IN (-) MILLIVOLT 0 z OUTPUT i OUT(+) rm) TRANSDUCER c (+) (-) OUT(-) S [| fan | - READOUT z > 4 Pa POWER SUPPLY e 0), | | a IN (4) a VOLTAGE aay COMMON OUTPUT iil 4) { (-) C.] (+) OUT(+) TRANSDUCER READOUT POWER SUPPLY (-), | ; (+) + CURRENT output | 1), 0) C.._| (4) (| TRANSDUCER READOUT oes Visit www.GemsSensors.com for most current information. 2200/2600 Series / p20f4 / 3-APR-14: PSIBAR CVD TYPES Dimensions 2200 Series Mini 4 Pin - No Connector 1/8-27 NPT Code B Code ll 08 mV Gauge/Absolute 7 |. oS Mini 4 Pin - With Connector Amplified Gauge 1/4 - 18 NPT 1.02, Code A | A | I A Code Ee QJ with snubber r snubbe 0.79 4 - 2% MAX _ | 20 IP67 Cable (Waterproof) Amplified Absolute 1/4-18 NPT Internal Code "or Ti (lB oC a | IP65 or NEMA4 Cable " " Code Code D or2 Maximum diameter 1.07" (27.3 mm) OH (4 lk 278 26.0 24 AWG Shielded PVC 7/16-20 UNF-2A : Code 2600 Series 04 im 10-6 or 8-4 Mil-C Connector | i 0.75 9 10-6 Code C 9/16-18 UNF-2A mV Gauge/Absolute 4 Amplified G code 8-4Code1 He agze! o 1P Large DIN 43650 Plug {| v | | |. sz Code G a G 1/8 Internal 2.09. ate cae Amplified Absolute 09 IB 'e 130->| + Conduit Connector with Cable wo o Coles NT { a G 1/4 External =) ode { Code 2 254 MAX _ 01 ij = 24 AWG Shielded PVC - |. oF ce - Maximum diameter 1.07" (27.3 mm) = Conduit Connector with Flying Leads R 1/4 Lu 1/2" NPT Code S ] a A 2 he Code 3 0.79 with length U = 17043 >| + kK ce Moulded, Immersible Cable 24 AWG, Vent, Shielded, 4 7 [Py Polyurethane Ko} ogo ke >| 0.75 Nose Cone Sink Weight | a4.67/121 7 8 hy Sl inch | Code 29 oe 2200/2600 Series / pSof4 / 3-APR-14 Visit www.GemsSensors.com for most current information. H-150Ge ems Sensors &Controls ~~ A ea! 7) nr Cc A Pm _ A Pa P< rn oS Cc (on) | A 7) How to Order Use the bold characters from the chart below to construct a product code Aso 83601 2200 +=: G Series J 2200 2600 Output A-100mV C-1-6V J-0.5-5.5V G-0.2-10.2V B-4-20mA_ D-1-11V R - 0-5V F -0.1-5.1V H - 1-5V S - 0-10V Pressure Datum A*-Absolute G- Gauge *Max absolute range is 25 bar. (< 300 psi) Pressure Range? psi FO7 -0-7.5 G60 - 0-600 Vac = -15 psi F15 - 0-15 H10 - 0-1,000 1F5 - Vac-0 F30 - 0-30 H15 - 0-1,500 3FO - Vac-15 F60 - 0-60 H20 - 0-2,000 GFO - Vac-45 G10 - 0-100 H30 - 0-3,000 1G0 - Vac-85 G15 - 0-150 H40 - 0-4,000 1G5 - Vac-135 G20 - 0-200 H50 - 0-5,000 2G0 - Vac-185 G30 - 0-300 H60 - 0-6,000 3G0 - Vac-285 G50 - 0-500 Pressure Range - bar Ai0 - 0-1 B25 - 0-25 Vac = -1 bar A16 - 0-1.6 B40 - 0-40 1A0 - Vac-0 A25 - 0-2.5 B60 - 0-60 1AG - Vac-0.6 AdO - 0-4 C10 - 0-100 2A5 - Vac-1.5 AGO - 0-6 C16 - 0-160 4A0 - Vac-3 Bi0 - 0-10 (25 - 0-250 GAO - Vac-5 Bi6 - 0-16 C40 - 0-400 1B0 - Vac-9 1B6 - Vac-15 2B5 - Vac-24 4B0 - Vac-39 Pressure Port 08 - 1/8-27 NPT External 02 - 1/4-18 NPT External OJ - 1/4 NPT External w/snubber OE - 1/4 NPT Internal OH - 1/2-14 NPT External 04 - 7/16-20 External (SAE #4, J514) 1P - 9/16-18 External (SAE #6, J1926-2) lJ - 7/16-20 External (SAE #4, J1926-2) European Threads 09 - G1/8 Internal 01 - G1/4 External OA - R1/4 External Submersible (2600 only) 19 - Plastic Nose Cone 29 - Sink Weight Nose Cone on Most Transducers Visit www.GemsSensors.com for most current information. -Day Delivery U A | Performance Code Accuracy/Thermal A- .25%/1.5% B - .15%/1.0% Cable Length U - No Cable Fitted! 2 D - 1 Metre (3 feet) E - 3 Metres (9 feet) F -5 Metres (16 feet) G - 10 Metres (32 feet) Apparatus Protection 2 - mV Only Transient Protection CE Mark, UR 3 - Amplified Only RFI Protected CE Mark, UR Electrical Connection (See Notes) 2200 Series A - 4 PIN DIN (Micro) Mating Connector Supplied B - 4 PIN DIN (Micro) Mating Connector Not Supplied 2 - Cable Nema 4 USA D - Cable European Color Code F - Gable Gland Metal IP67 2600 Series C - Fixed Plug Size 10-6 Mating Plug Not Supplied G - Fixed Plug To DIN 43650 Mating Plug Supplied M - Moulded Cable Immersible 1 - Fixed Plug Size 8-4 Mating Plug Not Supplied 3 - Conduit Connector 1/2NPT Ext. 1M Cable? Notes: 1. When electrical connectionis cable please select acable length irom Table 1 below. When electrical connection is DIN or plug style U must be specified. 2. Where electrical connection -3 and cable length -U occur in part number, the unit will be supplied with flying leads (4-1/27 IP30). 3. Additional Pressure Ranges are available. Please consult factory. Table 1 - Cable Length (2600 Series) (2200 Series select U through G) Code Length (M) Code Length (M) U No Cable Fitted M 40 D 1 N 50 E 3 P 75 F 5 Qa 100 G 10 R 125 H 15 Ss 150 J 20 4 170 K 25 5 200 L 30 6 225 Note: Maximum cable length on a 2200 is 10 meters. 2200/2600 Series / p4of4 / 3-APR-14