Chip NTC Thermistor
ABNTC-0805
STANDARD SPECIFICATIONS:
APPLICATIONS:
FEATURES:
2.0 x 1.25 x 0.85 mm.
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
ABRACON IS
CERTIFIED
30332
Esperanza, Rancho Santa Margarita, California
92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com
Revised: 05.05.14
Visit
www.abracon.com
for Terms & Conditions of Sale
ISO 9001:2008
Operating Temperature: -55˚C ~ +125˚C
Storage Temperature: -10˚C ~ +40˚C and RH 75% (Max.)
RoHS/RoHS II
Compliant
• Large B constant for high temperature sensing capability
• Designed for high density
• Available in standard EIA compatible case size
• Internal electrode designed for enhanced reliability
• Excellent aging stability
• For temperature measurement or sensor: Digital thermometer,
measuring instruments, temperature controller
• For temperature compensation: transistor circuit, TCXO, Crystal
Oscillator
• LED lighting driver, Notebook, Cell Phone, Power Supplies, Disk Drive
Part Number Resistance at 25oC
R25 (kΩ)
B constant
(25-50 oC) (K)
Max. Permissive
Operating
Current (25 oC)
(mA)
Thermal Time
Constant
Dissipation
Factor (mW/ oC)
Rated Electric
Power (mW)
ABNTC-0805-202Δ-3950□ 2.0 3950 1.0
<5sec 2.0 200
ABNTC-0805-502Δ-3950□ 5.0 3950 0.60
ABNTC-0805-682Δ-3950□ 6.8 3950 0.50
ABNTC-0805-103Δ-3450□ 10 3450 0.40
ABNTC-0805-103Δ-3950□ 10 3950 0.44
ABNTC-0805-153Δ-3500□ 15 3500 0.32
ABNTC-0805-223Δ-4050□ 22 4050 0.31
ABNTC-0805-473Δ-4150□ 47 4150 0.20
ABNTC-0805-503Δ-4150□ 50 4150 0.18
ABNTC-0805-683Δ-4150□ 68 4150 0.16
ABNTC-0805-104Δ-4250□ 100 4250 0.14
ABNTC-0805-154Δ-4300□ 150 4300 0.11
ABNTC-0805-224Δ-4350□ 220 4350 0.08
ABNTC-0805-334Δ-4400□ 330 4400 0.06
ABNTC-0805-474Δ-4500□ 470 4500 0.05
ABNTC-0805-684Δ-4500□ 680 4500 0.04
ABNTC-0805-135Δ-4700□ 1300 4700 0.03
Δ: Please specify the tolerance code of R25 (F=±1%, H=±3%, J=±5%, K=±10%).
□: Please specify the tolerance code of B value (F=±1%, H=±3%).
Unless otherwise specified, the standard atmospheric conditions for measurement/test as:
a. Ambient Temperature: 20±15oC oC
b. Relative Humidity: 65±20%
c. Air Pressure: 86 kPa to 106 kPa
Test Conditions