Energy-saving fans version 2012-10
The engineer’s choice
with ESM, ACi and iQ/iQ2-motor
2
The new generation of energy-saving fans
Comprehensive series
The series of these energy saving fans includes the compact fan series of ACi 4400 as well as
based on the energy saving motor (ESM), axial fans and centrifugal modules as well as the iQ-motor
as an energy saving variant of the Q-motor.
Axial fans are available in sizes of 130, 172, 200, 230, 250 and 300 mm plus the compact fan ACi
4400 with the dimensions 119 x 119 x 38 mm. With their new rotors and wall rings, which have
been optimised according to aerodynamic criteria, the fans now work even more quietly and require
no varnish, a particularly environmentally friendly feature.
Energy saving centrifugal modules are available in sizes of 190 and 220 mm. These are especially
appealing due to their compact and aerodynamically optimised design, which allows customers to
install them quickly and hassle-free.
The K1G200 energy saving centrifugal module in a diagonal impeller design rounds out the ESM
series. It particularly distinguishes itself due to noise-optimised and air flow-optimised performance
in the medium pressure range. ebm-papst sets the benchmark here, too.
The existing series was expanded with additional versions and functions to meet new market de-
mands. Among other things, this includes a 24 VDC design with an integrated 0-10 VDC open loop
speed control and a speed monitoring output.
A 0-10 VDC open loop speed control is now possible even for the existing line-fed designs by using
an ESM+ plug-in module.
This series is supplemented by the energy saving iQ-motor based on ebm-papst's GreenTech EC
technology. The iQ2series further expands the offering with additional functions. Due to its dimen-
sions and mounting options, which are identical to the Q-motor already established on the market,
customers are given the possibility of a 1:1 replacement without extensive renovations.
The iQ-motor can be readily installed with normal axial impellers with a 154 to 254 mm diameter.
Maximum efficiency
Our fans and motors achieve a maximum motor efficiency of over 70% and thus only need 1/3 to
1/6 of the power of an otherwise normal shaded-pole motor. Higher efficiency also means lower int-
rinsic heating during operation at the same time, which dissipates less heat into the surrounding
area. This means that less cooling power must be generated, thus resulting in additional energy
savings.
Energy savings have become an important topic in almost every aspect of life. Our extended energy
saving fan series, based on the energy saving motor (ESM) and the iQ-motor, offers high efficiency
throughout a long service life and a significant decrease in energy consumption along with it. This is
precisely what is required for refrigeration systems, such as in refrigerated and freezer cases or for
condensing units.
3
Green Tech: The Green Company 4
The new generation of energy-saving fans 2
Energy-saving axial fans 6
Energy-saving centrifugal modules 32
Table of contents
ESM/ACi accessories 40
ESM electrical connections 46
iQ/iQ2-motor 48
iQ/iQ2-motor accessories 58
Technical parameters & scope 62
ebm-papst representatives & subsidiaries 66
Sustainability is at the centre of our
thoughts and actions. Out of conviction!
Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked
according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better
than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy.
5
GreenTech is acknowledged and certified.
Every step in our chain of production meets the stringent standards of
environmental specialists and the public. The 2008 Environmental Prize
of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency
Award 2009 of the dena – to give just a few examples – testify to this.
The environmental advantage gained in the performance of the products
developed from our GreenTech philosophy can also be measured in the
fulfilment of the most stringent energy and environmental standards.
In many instances, our products are already well below the thresholds
energy legislation will impose a few years from now – several times over.
Our customers profit from this every day.
The heart of GreenTech is future-oriented EC technology from ebm-
papst. The EC technology at the core of our most efficient motors and
fans allows efficiency of up to 90%, saves energy at a very high level,
significantly extends service life and makes our products maintenance-
free. These values pay off not only for the environment, but every cent al-
so pays off for the user! All ebm-papst products – even those for which
GreenTech EC technology does not (yet) make sense from an application
viewpoint – feature the greatest possible connection of economy and
ecology.
GreenTech is pro-active development.
Even in the design phase, the materials and processes we use are optimi-
sed for the greatest possible eco-friendliness, energy balance and –
wherever possible – recyclability. We continually improve the material
and performance of our products, as well as the flow and noise charac-
teristics. At the same time, we significantly reduce energy consumption.
Close co-operation with universities and scientific institutes and the pro-
fessorship we endow in the area of power engineering and regenerative
energies allows us to profit from the latest research findings in these
fields – and at the same time ensure highly qualified young academics.
GreenTech is eco-friendly production.
GreenTech also stands for maximum energy efficiency in our production
processes. There, the intelligent use of industrial waste heat and ground-
water cooling, photovoltaics and, of course, our own cooling and venti -
lation technology are of the utmost importance. Our most modern plant,
for instance, consumes 91% less energy than currently specified and
required. In this way, our products contribute to protecting the environ-
ment, from their origin to their recyclable packaging.
Series: The existing series of energy saving axial fans was expanded by adding the ACi 4400 series
and a compact fan with size 130. In addition, the ESM series is now available as a 24 VDC version
with an integrated 0-10 VDC open loop speed control output and a speed monitoring signal. These
control options have also become possible for line-fed designs via an additional ESM+ plug-in
module.
System: Not just our existing shaded-pole motors were replaced by high-efficiency GreenTech EC
motors for our fans, but a complete new system was developed as a whole consisting of an EC
motor, impeller and wall ring. Optimum efficiency for the best possible noise behaviour was only
able to be achieved by having all of the components perfectly harmonised together.
Energy efficiency: The energy saving motors achieve a maximum efficiency of over 70%. So they
only need 1/3 to 1/6 the power of an otherwise normal shaded-pole motor. But higher efficiency
also means lower intrinsic heating during operation at the same time, which dissipates less heat
into the surrounding area. This results in further energy savings, since less cooling capacity needs
to be put in place from the beginning.
Easy installation: Effort needed by the customer for installation and logistics is reduced to a mini-
mum due to the complete system. In addition to the fan itself, only screws are needed for mounting.
Further savings result from the pluggable connection line. For example, this allows installation time
to be drastically reduced due to a pre-installed cable harness. The number of variants can be sub-
stantially reduced by subsequent programming as well by having different air performance levels
customised accordingly – even at a later point in time. An earth wire can be omitted due to a design
in protection class 2.
Robust design (ESM): Ten years of field experience with more than 3 million energy saving motors
shows that the system is robust, maintenance-free and durable. Depending on environmental condi-
tions, the service life usually exceeds 60,000 hours. The stator, which is hermetically sealed with a
coat of plastic, is optimally protected from ambient influences. And the electronics are protected
from humidity with a sealed off cover, so that IP 54 protection requirements are fulfilled. Shock
loads of more than 50g have no effect on the fan due to the stable design.
Certifications:
ACi 4400: UL (507), VDE (EN 60950), CSA
ESM: All of the approvals required in the refrigerated case industry are present
or in progress.
VDE: EN 60335-1, -2-24, -2-80, -2-89
UL 1004-1, 1004-3, UL 60730 and GOST
6
The new energy-saving axial fans
ESM Size 300 28
ESM Size 200, 230, 250 14
ESM Size 130, 172 10
ACI 4400 8
7
8
Energy-saving axial fans
Series ACi 4400 119 x 119 x 38 mm
Material: Housing: Plastic PBT
fibreglass-reinforced
Blade: Plastic PA,
fibreglass-reinforced
Number of blades: 5
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Clockwise, seen
on rotor
Insulation class: "E"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics
Moisture protection: Motor and circuit
board are coated
Electrical connection: Plug-in connection
lateral
Protection class: II
Product conforming to standard: CE
Approvals: UL (507), VDE (EN 60950),
CSA
Nominal data
Type
subject to alterations
ACi 4420 ML
VAC VAC Hz rpm W mA dB(A) Bel(A) °C kg
1~ 230 195...265 50/60 1850 1,4 17 25 4,1 -20..+75 0,25
ACi 4420 H
Curve
Nominal voltage
Frequency
Speed/rpm
Input power
Current draw
Perm. amb. temp.
Mass
A
ACi 4420 HH
ACi 4410 HH
Nominal voltage
range
Sound pressure level
Sound power level
1~ 230 195...265 50/60 3000 3,3 35 39 5,1 -20..+75 0,25
B
1~ 230 195...265 50/60 3350 4,4 41 42 5,3 -20..+75 0,25
C
1~ 115 85...132 50/60 3350 4,4 82 42 5,3 -20..+75 0,25
D
11
2
3
4
2
3
4
2
3
4
25 50 75 100 125 150 175
020 40 60
10
20
30
40
50
60
70
0,1 0,2
cfm
qV
pfs Pa
in H2O
m3/h
80 100
1
Curves
1
2
3
4
1
2
3
4
1850
1850
1850
1850
3000
3000
3000
3000
1,4
1,5
1,6
1,7
3,3
3,9
3,9
4,7
17
18
19
19
35
39
44
46
A
A
A
A
B
B
B
B
1
2
3
4
1
2
3
4
3350
3350
3350
3350
3350
3350
3350
3350
4,4
5,1
5,7
5,9
4,4
5,1
5,7
5,9
41
48
53
55
82
96
106
110
C
C
C
C
D
D
D
D
n
rpm
Pe
W
I
mA
Air performance measured
as per: ISO 5801,
Installation category A,
and without protection against
accidental contact
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see Compact fans catalogue
version 2011, p. 8-16
A
B
C
D
9
Accessories
p. 44 ff.
"A"
104.8 ±0.2
"B"
A
A
119 ±0.3
38±0.5
Ø4.3 ±0.15
6±0.3
Ø4.3 ±0.15
6±0.3
R 0.3
R 0.3
A-A
"V"
L
ACi 4400
N
Electr. connection:
Plug connection on
both sides possible.
10
Material: Wall ring: Plastic PP, fibreglass-
reinforced; Blade:Plastic PA,
fibreglass-reinforced
Number of blades: 7
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE;
EN 60335-1
Approvals: VDE, UL, CSA, GOST are
applied for
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
Nominal data
Type
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
W1G130-AA49 -01 M1G 055-AI
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 3200 24 0,38 90 -30..+60 0,75
W1G130-AA25 -01 M1G 055-AI 1~ 230 50/60 3200 24 0,19 90 -30..+70 0,75
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
Perm. amb. temp.
Mass
Motor
A
B
Energy-saving axial fans
Ø 130
1
5
2
6
3
7
4
8
50 100 150 200 250 300 350
040 80 120
10
20
30
40
50
60
70
80
90
0,1 0,30,2
cfm
qV
pfs Pa
in H2O
m3/h
160 200
nmax. = 3200 min-1 nmin. = 1100 min-1
n = 2800 min-1
Curves
A1
2
3
4
5
6
7
8
3200
3200
3200
3200
2800
2800
2800
2800
23
24
24
24
16
16
16
16
0,38
0,38
0,38
0,38
0,26
0,26
0,26
0,26
A
A
A
A
A
A
A
A
63
61
60
63
60
58
57
60
B
1
2
3
4
5
6
7
8
3200
3200
3200
3200
2800
2800
2800
2800
23
24
24
24
16
16
16
16
0,19
0,19
0,19
0,19
0,13
0,13
0,13
0,13
B
B
B
B
B
B
B
B
63
61
60
63
60
58
57
60
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
450+20
40±5
6
Ø172±0.5
Ø162+0.1
-0.3
Ø151±0.5
58-1
55±0.3
10 10
Ø
4
.2
Ø
4
.2
Ø
5
1.5 1.5
Ø
5
A
A
A-A
±0.1
±0.1
11
"V"
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
Handheld Pro-
grammer p. 41
Connection lead (total length 450 mm)
is fitted ex works and can be detached.
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
Material: Wall ring: Plastic PP
Blade: Plastic PA,
fibreglass-reinforced
Number of blades: 5
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
Nominal data
Type
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
W1G172-EC95 -01 M1G 055-BD
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 2500 21 0,30 60 -30..+50 0,95
W1G172-EC91 -01 M1G 055-BD 1~ 230 50/60 2500 22 0,18 60 -30..+50 0,95
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
Perm. amb. temp.
Mass
Motor
A
B
Energy-saving axial fans
Ø 172
1
2
3
4
6
7
8
5
100 200 300 400 500
050100 150 200 300250
0,04 0,08 0,12 0,16 0,20 0,24
nmax. = 2500 min-1 nmin. = 900 min-1
n = 1700 min-1
10
20
30
40
50
60
cfm
qV
pfs Pa
in H2O
m3/h
Curves
A1
2
3
4
5
6
7
8
2500
2500
2500
2500
1700
1700
1700
1700
20
21
21
21
9
10
10
10
0,28
0,30
0,30
0,30
0,14
0,16
0,16
0,16
A
A
A
A
A
A
A
A
62
63
63
63
54
53
53
54
B
1
2
3
4
5
6
7
8
2500
2500
2500
2500
1700
1700
1700
1700
21
22
22
22
9
10
10
10
0,17
0,18
0,18
0,18
0,07
0,08
0,08
0,08
B
B
B
B
B
B
B
B
62
63
63
63
54
53
53
54
12
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
"V"
Accessories
p. 40 ff.
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
13
450+20
40±5
6
4
78.5
35 4x Ø4.3
Ø192
Ø172
Ø208
Ø222
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
Material: Wall ring: Plastic PP
epylen
Blade: Plastic PA,
fibreglass-reinforced
Number of blades: 5
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
A
B
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
Nominal data
Type
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
W1G200-EC91 -27 M1G 055-BD
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 1300 8,0 0,11 23 -30..+50 1,0
W1G200-EC87 -25 M1G 055-BD 1~ 230 50/60 1300 8,0 0,07 23 -30..+50 1,0
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
Mass
Motor
1
2
3
4
6
7
8
5
100 200 300 400
050100 150 200 250
5
0,02 0,04 0,06 0,08 0,10
nmax. = 1300 min-1 nmin. = 500 min-1
n = 900 min-1
10
15
20
25
cfm
qV
pfs Pa
in H2O
m3/h
Curves
A
A
B
Energy-saving axial fans
Ø 200
1
2
3
4
5
6
7
8
1300
1300
1300
1300
900
900
900
900
7
8
8
8
3
4
4
4
0,09
0,10
0,10
0,11
0,05
0,05
0,05
0,05
A
A
A
A
A
A
A
A
50
49
48
51
41
41
40
41
B
1
2
3
4
5
6
7
8
1300
1300
1300
1300
900
900
900
900
7
8
8
8
3
4
4
4
0,06
0,07
0,07
0,07
0,03
0,04
0,04
0,04
B
B
B
B
B
B
B
B
50
49
48
51
41
41
40
41
14
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
Ø220
Ø200
Ø236
Ø250
4x Ø4.3
6
40±5
450+20
4
40
78.5
"V"
Accessories
p. 40 ff.
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
15
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
Material: Wall ring: Plastic PP
Blade: Plastic PA,
fibreglass-reinforced
Number of blades: 5
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
Nominal data
Type
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
W1G200-EC95 -47 M1G 055-BD
W1G200-EC91 -45 M1G 055-BD
Motor
1
2
3
4
6
7
8
5
100 200 300 400 500 600 700
050100 150 200 250 300 350 400
0,04 0,08 0,12 0,16 0,20 0,24
nmax. = 2100 min-1 nmin. = 800 min-1
n = 1500 min-1
10
20
30
40
50
60
cfm
qV
pfs Pa
in H2O
m3/h
Curves
A
Energy-saving axial fans
Ø 200
1
2
3
4
5
6
7
8
2100
2100
2100
2100
1500
1500
1500
1500
28
30
31
31
14
15
16
16
0,42
0,45
0,46
0,46
0,22
0,22
0,26
0,26
A
A
A
A
A
A
A
A
62
61
60
62
54
54
53
55
B
1
2
3
4
5
6
7
8
B
B
B
B
B
B
B
B
2100
2100
2100
2100
1500
1500
1500
1500
29
30
31
31
14
16
16
16
0,22
0,23
0,24
0,24
0,11
0,12
0,13
0,13
62
61
60
62
54
54
53
55
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 2100 31 0,46 55 -30..+50 1,0
1~ 230 50/60 2100 31 0,24 55 -30..+50 1,0
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
Mass
A
B
16
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
Accessories
p. 40 ff.
Ø220
Ø200
Ø236
Ø250
4x Ø4.3
6
40±5
450+20
4
40
78.5
"V"
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
17
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
18
Energy-saving axial fans
Ø 200
Material: Wall ring: epylen
Blade: Plastic PA,
fibreglass-reinforced
Number of blades: 5
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Approvals: VDE, UL, CSA, GOST are
applied for
Technical features: Control input 0-10
VDC / PWM, Tach output
Nominal data
Type
subject to alterations
W1G200-EF41 -01 M1G 055-BD
W1G200-EF01 -01 M1G 055-BD
Motor VDC VDC rpm W A Pa °C kg
24 16-28 1550 11 0,50 30 -30..+50 1,0
24 16-28 2130 29 1,50 55 -30..+50 1,0
Curve
Nominal voltage
Nominal
voltage range
Speed/rpm(1)
Perm. amb. temp.
Mass
A
B
Input power(1)
current draw(1)
Max. back pressure
11
2
2
3
3
4
4
100 200 300 400 500 600 700 800
0100
10
20
40
50
60
0,04 0,160,08
30
0,12 0,24
70
0,280,20
cfm
qV
pfs Pa
in H2O
m3/h
200 300 400 500
Curves
1
2
3
4
1
2
3
4
1550
1530
1510
1515
2130
2085
2050
2050
11
11
11
11
29
30
31
31
0,50
0,50
0,51
0,51
1,50
1,56
1,61
1,62
A
A
A
A
B
B
B
B
54
53
52
55
62
62
61
59
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
B
A
(1) Nominal data running at free air.
19
Electr. connection
p. 46
Ø220
Ø200
Ø236
Ø250
4x Ø4.3
6
40±5
450+20
4
40
78.5
"V"
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
Accessories
p. 41
Electr. connection:
680 R
4
3
2Reverse-polarity
protection
47 V
UB
UN +24 VDC
PWM/0-10 VDC
Tacho
GND
1
RE>100K
Tacho
GND1
20
Energy-saving axial fans
Ø 200
Material: Wall ring: epylen
Blade: Plastic PA,
fibreglass-reinforced
Number of blades: 5
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE;
EN 60335-1
Approvals: VDE, UL, CSA, GOST are
applied for
Technical features: Control input 0-10
VDC / PWM, Output 10 VDC max. 1.1 mA,
Tach output
11
2
2
3
3
4
4
100 200 300 400 500 600 700
0 100
10
20
30
40
50
0,04 0,120,08 0,200,16
cfm
qV
pfs Pa
in H2O
m3/h
200 300 400
Curves
1
2
3
4
1
2
3
4
1300
1300
1300
1300
2100
2100
2100
2100
7,0
8,0
8,0
8,0
29
30
31
31
0,06
0,07
0,07
0,07
0,23
0,24
0,24
0,24
A
A
A
A
B
B
B
B
50
49
48
48
62
62
60
59
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
Nominal data
Type
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
W1G200-EC87 -A2 M1G 055-BD
W1G200-EC91 -A4 M1G 055-BD
Motor VAC Hz rpm W A Pa °C kg
1~ 230 50/60 1300 8 0,07 23 -30..+50 1,0
1~ 230 50/60 2100 31 0,24 55 -30..+50 1,0
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
Mass
A
B
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
A
B
±5
±5
450+20
40
6
1000+20
40
6
105.5
40
78.5
4
Ø4.3(4x)
Ø220
Ø250
Ø200
Ø236
21
"V"
Electr. connection
p. 47
Accessories
p. 40 ff.
Electr. connection:
Imax=1.1mA
100μF
CON10
1
3
4
2
680R
ZMM47
1
2
47k 47k
AC1 P
AC2 N
L
N
+10V
10V/PWM
GND
Tacho
2
1
1.25A
CON50
Material: Blade: Plastic PA,
fibreglass-reinforced
Guard grille: epylen
Number of blades: 5
Direction of air flow: "A", intake over
guard grille
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
Nominal data
Type
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
S1G 200-CA95 -02 M1G 055-BD
S1G 200-CA91 -02 M1G 055-BD
Motor
1
2
3
4
6
7
8
5
100 200 300 400 500 600 700
050100 150 200 250 300 350 400
0,04 0,08 0,12 0,16 0,20
nmax. = 2000 min-1 nmin. = 800 min-1
n = 1500 min-1
10
20
30
40
50
cfm
qV
pfs Pa
in H2O
m3/h
Curves
A
Energy-saving axial fans
Ø 200
B
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 2000 31 0,43 45 -30..+50 0,95
1~ 230 50/60 2000 34 0,26 45 -30..+50 0,95
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
Mass
A
B
1
2
3
4
5
6
7
8
A
A
A
A
A
A
A
A
1
2
3
4
5
6
7
8
B
B
B
B
B
B
B
B
2000
2000
2000
2000
1500
1500
1500
1500
30
30
30
31
17
18
19
20
0,43
0,43
0,43
0,43
0,28
0,28
0,28
0,28
64
64
63
64
59
58
58
59
2000
2000
2000
2000
1500
1500
1500
1500
32
33
33
34
18
19
19
20
0,24
0,25
0,25
0,26
0,16
0,16
0,16
0,16
64
64
63
64
59
58
58
59
22
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst short nozzle
and with protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
380
40±5
±20
6
37.5
Ø200
40 38.5
3
Ø260
Ø278
4x Ø6.5
Accessories
p. 40 ff.
"A"
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
23
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
Energy-saving axial fans
Ø 230
1
2
3
4
6
7
8
5
200 400 600 800
0 100 200 300 500400
0,04 0,08 0,12 0,16
nmax. = 1500 min-1 nmin. = 700 min-1
n = 1000 min-1
10
20
30
40
cfm
qV
pfs Pa
in H2O
m3/h
Curves
Nominal data
Type
subject to alterations
W1G230-EB97 -01 M1G 055-BD
W1G230-EB89 -01 M1G 055-BD
Motor
Material: Wall ring: Plastic PP
Blade: Plastic PA,
fibreglass-reinforced
Number of blades: 5
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
A
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
B
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 1500 23 0,35 36 -30..+50 1,05
1~ 230 50/60 1500 26 0,20 36 -30..+50 1,05
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
Mass
A
B
1
2
3
4
5
6
7
8
1500
1500
1500
1500
1000
1000
1000
1000
23
23
23
23
9
10
10
10
0,35
0,35
0,35
0,35
0,15
0,16
0,16
0,16
A
A
A
A
A
A
A
A
58
58
58
57
48
48
48
48
1
2
3
4
5
6
7
8
B
B
B
B
B
B
B
B
1500
1500
1500
1500
1000
1000
1000
1000
24
25
25
26
10
11
11
11
0,19
0,19
0,19
0,20
0,09
0,09
0,10
0,10
58
58
58
57
48
48
48
48
24
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and without protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
"V"
Accessories
p. 40 ff.
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
25
78.5
50
4
450+20
40±5
6
Ø250
4x Ø4.3
Ø230
Ø266
Ø280
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
Energy-saving axial fans
Ø 250
1
2
3
4
6
7
8
5
200 400 600 800 1000
0 100 200 300 500400
0,04 0,08 0,12 0,16
nmax. = 1700 min-1 nmin. = 900 min-1
n = 1200 min-1
10
20
30
40
cfm
qV
pfs Pa
in H2O
m3/h
Curves
Nominal data
Type
subject to alterations
W1G250-BB21 -01 M1G 055-BI
W1G250-BB17 -01 M1G 055-BI
Motor
Material: Wall ring: Plastic PP
Blade: Plastic PA,
fibreglass-reinforced
Number of blades: 5
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
A
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
B
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 1700 32 0,47 40 -30..+50 1,55
1~ 230 50/60 1700 32 0,24 40 -30..+50 1,55
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
Mass
A
B
1
2
3
4
5
6
7
8
1700
1700
1700
1700
1200
1200
1200
1200
30
31
32
32
14
15
16
17
0,44
0,45
0,47
0,47
0,22
0,24
0,25
0,26
A
A
A
A
A
A
A
A
62
63
64
65
53
54
55
57
1
2
3
4
5
6
7
8
B
B
B
B
B
B
B
B
1700
1700
1700
1700
1200
1200
1200
1200
30
31
32
32
14
15
16
17
0,24
0,24
0,24
0,24
0,12
0,13
0,14
0,14
62
63
64
65
53
54
55
57
26
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and with protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
"V"
Accessories
p. 40 ff.
27
Ø295
Ø315
340
6
Ø250
45˚
4x90˚
296
4xØ7
Ø280
80
92
4
40±5
±20
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
Energy-saving axial fans
Ø 300
1
2
3
4
6
7
8
5
200 400 600 800 1000 1200
0 100 200 300 500400 600 800700
0,04 0,08 0,12 0,14
nmax. = 1300 min-1 nmin. = 700 min-1
n = 900 min-1
10
0,06
15
0,02
5
20
0,10
25
30
35
cfm
qV
pfs Pa
in H2O
m3/h
Curves
Nominal data
Type
subject to alterations
W1G300-BB23 -01 M1G 055-BI
W1G300 -BB19 -01 M1G 055-BI
Motor
Material: Wall ring: Plastic PP
Blade: Plastic PA,
fibreglass-reinforced
Number of blades: 5
Direction of air flow:
"V", exhaust over struts
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
A
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
B
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 1300 35 0,50 35 -30..+50 1,75
1~ 230 50/60 1300 35 0,27 35 -30..+50 1,75
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
Mass
A
B
1
2
3
4
5
6
7
8
1300
1300
1300
1300
900
900
900
900
28
31
32
35
12
14
15
16
0,41
0,46
0,47
0,50
0,24
0,25
0,26
0,27
A
A
A
A
A
A
A
A
58
58
57
58
50
49
49
50
1
2
3
4
5
6
7
8
B
B
B
B
B
B
B
B
1300
1300
1300
1300
900
900
900
900
32
34
34
35
13
14
15
16
0,25
0,27
0,27
0,27
0,12
0,13
0,14
0,15
58
58
57
58
50
49
49
50
28
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst full nozzle
and with protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
Ø380
Ø397
4xØ6.3
4x90˚
45˚
360
Ø300
40±5
±20
6
290
Ø350
4
92
80
"V"
Accessories
p. 40 ff.
29
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
Material: Blade: Plastic PA,
fibreglass-reinforced
Guard grille: epylen
Number of blades: 5
Direction of air flow: "A", intake over
guard grille
Direction of rotation: Counter-clockwise,
seen on rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
Energy-saving axial fans
Ø 300
1
2
3
4
6
7
8
5
200 400 600 800 1000 1200
0 100 200 300 500 700400 600
0,04 0,08 0,12 0,16
nmax. = 1250 min-1 nmin. = 700 min-1
n = 900 min-1
10
20
30
40
cfm
qV
pfs Pa
in H2O
m3/h
Curves
Nominal data
Type
subject to alterations
S1G 300-CA23 -02 M1G 055-BI
S1G 300-CA19 -02 M1G 055-BI
Motor
A
(1) Nominal data in operating point with maximum load and 115 or 230 VAC
1
2
3
4
5
6
7
8
1250
1250
1250
1250
900
900
900
900
31
32
32
35
13
14
16
17
0,45
0,47
0,48
0,56
0,24
0,26
0,30
0,32
A
A
A
A
A
A
A
A
64
62
62
63
55
54
53
54
B
1
2
3
4
5
6
7
8
B
B
B
B
B
B
B
B
1250
1250
1250
1250
900
900
900
900
27
30
32
35
13
14
16
17
0,21
0,23
0,24
0,27
0,12
0,13
0,15
0,16
64
62
62
63
55
54
53
54
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 1250 35 0,56 35 -30..+50 1,4
1~ 230 50/60 1250 35 0,27 35 -30..+50 1,4
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
Mass
A
B
30
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
in ebm-papst short nozzle
and with protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
330
40±5
±20
6
Ø300
45
3
43
38
4x Ø6.5
Ø360
Ø377
Accessories
p. 40 ff.
"A"
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
31
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
The perfect combination!
For the new energy saving centrifugal modules, we have combined a backward curved centrifugal
impeller already established on the market with new compact modules. The result is a highly com-
pact unit with an integrated inlet nozzle and motor suspension directly connected to the mounting
plate. The mounting plate, inlet nozzle and motor suspension consist of a robust and durable plastic.
This has the advantage that no compromises have to be made in the aero-acoustic design.
The energy saving centrifugal modules are available with impellers with a 190 and 220 mm diame-
ter. They are extremely compact and easy to install. Intricate adjustments to the impeller for the
nozzle are not necessary. An inlet side guard grille is available for installation as an accessory.
The new diagonal K1G200 with an energy saving motor rounds out the series. The diagonal impeller
design particularly distinguishes itself through its noise-optimised and air flow-optimised perfor-
mance in the medium pressure range and sets new benchmarks in the process.
Take advantage of the benefits offered by a completely pre-installed functional unit:
– Compact design
– Optimised, tested and guaranteed functional unit
– Plug-and-play characteristic
– Easy installation
– Energy saving motor (ESM)
– Optional guard grille
– Simple logistics
Maximum efficiency
The energy saving motors achieve a maximum efficiency of over 70%. So they only need 1/3 to 1/6
the power of an otherwise normal shaded-pole motor. But higher efficiency also means lower intrin-
sic heating during operation at the same time, which dissipates less heat into the surrounding area.
This means that less cooling power must be generated from the outset, thus resulting in additional
energy savings.
32
The new energy-saving centrifugal modules
Size 200, diagonal 38
Size 220, backward curved 36
Size 190, backward curved 34
33
EC centrifugal module
backward curved, Ø 190
100 200 300 400
0 50 100 150 200 250
40
20
60
80
140
120
100
160
180
0,2 0,4 0,60,1 0,3 0,70,5
nmax. = 2000 min-1 nmin. = 700 min-1
n = 1600 min-1
6
5 1
2
3
4
7
8
cfm
qV
pfs Pa
in H2O
m3/h
Curves
2000
2000
2000
2000
1600
1600
1600
1600
2000
2000
2000
2000
1600
1600
1600
1600
21
25
30
26
13
15
17
15
21
25
30
26
13
15
17
15
0,34
0,38
0,45
0,39
0,19
0,25
0,27
0,26
0,16
0,19
0,24
0,20
0,10
0,11
0,13
0,12
62
60
59
60
57
55
53
55
62
60
59
60
57
55
53
55
Nominal data
Type
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
K1G 190
K1G 190
Motor
M1G 055-BD
M1G 055-BD
Material: Housing: Plastic PA,
fibreglass-reinforced
Impeller: Plastic PA,
fibreglass-reinforced
Rotor: Galvanised
Number of blades: 7
Direction of rotation: clockwise, seen on
rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None, open rotor
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST are
applied for
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
VAC Hz rpm W A °C
1~ 115 50/60 2000 30 0,45 -30..+50
1~ 230 50/60 2000 30 0,24 -30..+50
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Max.
input power(1)
Max.
current draw(1)
Perm. amb. temp.
A
B
1
2
3
4
5
6
7
8
A
A
A
A
A
A
A
A
1
2
3
4
5
6
7
8
B
B
B
B
B
B
B
B
A
B
34
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against acci-
dental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
Centrifugal module
with support bracket
K1G 190-AD50 -02
kg
1,3
Mass of centrifugal
module with support
bracket
K1G 190-AD73 -02 1,3
Ø256+1
94
109
6
450+20
16.5°
8x45°
4xØ4.3
Ø280
Ø266
Ø190
4
40±5
Accessories
p. 40 ff.
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
35
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
EC centrifugal module
backward curved, Ø 220
Curves
1600
1600
1600
1600
1200
1200
1200
1200
1600
1600
1600
1600
1200
1200
1200
1200
18
26
32
30
7
11
13
12
18
25
33
30
7
10
13
12
59
57
55
56
52
50
48
50
59
57
55
56
52
50
48
50
Nominal data
Type
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
K1G 220
K1G 220
Motor
M1G 055-BD
M1G 055-BD
Material: Housing: Plastic PA,
fibreglass-reinforced
Impeller: Plastic PA,
fibreglass-reinforced
Rotor: Galvanised
Number of blades: 11
Direction of rotation: clockwise, seen on
rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None, open rotor
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST are
applied for
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
VAC Hz rpm W A °C
1~ 115 50/60 1600 32 0,50 -30..+50
1~ 230 50/60 1600 33 0,25 -30..+50
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
A
B
0,25
0,37
0,50
0,44
0,10
0,15
0,18
0,18
0,14
0,21
0,25
0,25
0,06
0,08
0,11
0,10
A
B
1
2
3
4
5
6
7
8
A
A
A
A
A
A
A
A
1
2
3
4
5
6
7
8
B
B
B
B
B
B
B
B
nmax. = 1600 min-1 nmin. = 600 min-1
n = 1200 min-1
100 200 300 400 500
0 100 150 250 30050
20
40
60
80
100
120
140
0,08 0,16 0,24 0,32 0,40 0,48 0,56
200
6
5 1
2
3
4
7
8
cfm
qV
pfs Pa
in H2O
m3/h
36
Max.
input power(1)
Max.
current draw(1)
n
rpm
Pe
W
LWA
dB(A)
I
A
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
Centrifugal module
with support bracket
K1G 220-AF90 -02
kg
1,4
Mass of centrifugal
module with support
bracket
K1G 220-AF92 -02 1,4
Ø
310
4x90°
28.5°
295
Ø
Ø220
4
6
450+20
105
113
Ø281+1
Ø4.34x
40±5
Accessories
p. 40 ff.
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
37
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
EC centrifugal module
diagonal, Ø 200
nmax. = 2000 min-1 nmin. = 700 min-1
n = 1500 min-1
6
5 1
2
3
4
7
8
100 200 300 400 500
0 50 200 250100 150 300
20
40
60
80
100
120
0,1 0,2 0,4 0,50,3
cfm
qV
pfs Pa
in H2O
m3/h
Curves
27
29
31
30
14
16
17
16
31
33
35
35
16
19
20
18
0,38
0,42
0,50
0,43
0,22
0,24
0,26
0,25
0,24
0,26
0,30
0,27
0,13
0,14
0,18
0,14
63
62
62
62
57
56
55
55
63
62
62
62
57
56
55
55
Material: Housing: Plastic PA,
fibreglass-reinforced
Blades: Plastic PA,
fibreglass-reinforced
Number of blades: 7
Direction of rotation: clockwise, seen on
rotor
Type of protection: IP 54
Insulation class: "B"
Mounting position: Any
Condensate discharges: None, open rotor
Mode of operation: Con. operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics and
TOP
Electrical connection: Plug-in connection
on motor side
Protection class: II
Product conforming to standard: CE
Approvals: VDE, UL, CSA, GOST are
applied for
Speed: Using the programming unit, 2
speeds between nmin and nmax can be
programmed.
1
2
3
4
5
6
7
8
A
A
A
A
A
A
A
A
1
2
3
4
5
6
7
8
B
B
B
B
B
B
B
B
A
B
Nominal data
Type
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
K1G 200
K1G 200
Motor
M1G 055-BD
M1G 055-BD
VAC Hz rpm W A PA °C
1~ 115 50/60 2000 31 0,50 120 -30..+50
1~ 230 50/60 2000 35 0,30 120 -30..+50
Curve
Nominal voltage
Frequency
Speed/rpm(1)
Perm. amb. temp.
A
B
38
Max.
input power(1)
Max.
current draw(1)
Max. back pressure
n
rpm
Pe
W
LWA
dB(A)
I
A
2000
2000
2000
2000
1500
1500
1500
1500
2000
2000
2000
2000
1500
1500
1500
1500
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LWA as per ISO 13347,
LpA measured at 1 m distance
to fan axis
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
For detailed information
see page 62 ff.
Ø250
4
78.5
Ø220
4xØ4.3
6
450+20
4xØ5
Ø236
40±5
Connection lead (total length 450 mm) is fitted ex works and can be detached
Other lengths available as accessory.
Accessories
p. 40 ff.
Centrifugal module
with support bracket
K1G 200-AA95 -02
kg
1,2
Mass of centrifugal
module with support
bracket
K1G 200-AA73 -02 1,2
39
Electr. connection: L1
S
black
Speed selection
Energy-saving
motor / fan
(ESM)
blue
brown
Mains supply
voltage
off on (L1 or N)
n1 n2
N
S
Speed selection
L1 or N
Connection leads (ESM)
Design: Cable conforms to UL standards,
sealed plug. Custom-built connection leads
on request.
a
31,5
22,5
6
40
27,5
10
9,3
Connection lines for energy-saving motors 115/230 VAC
Part no.
10637-4-1040
subject to alterations
a
450
10640-4-1040 600
10638-4-1040 1500
10639-4-1040 2000
Jacketed cable, internal line
(UL Style 2464/1061)
3 x AWG20 (approx. 0.5 mm2)
Brass lead tips
Guard grilles (ESM)
ab
Material: Plastic PA, fibreglass-reinforced
Guard grille (sucking side) for energy-saving centrifugal modules
Part no. Size ab
19051-2-2929 190 133,0 9,0
22051-2-2929 220 166,0 8,7
subject to alterations
40
41
Connection leads (ESM)
Design: Cable conforms to UL standards,
sealed plug. Custom-built connection leads
on request.
a
31,5
22
,5
6
40
27,5
10
9,3
Connection lines for energy-saving motors 24 VDC
Part no.
10710-4-1040
subject to alterations
a
450
10711-4-1040 1500
Jacketed cable, internal line
(UL Style 2464/1061)
4 x AWG20 (approx. 0.5 mm2)
Brass lead tips
Handheld Programmer
Easy speed programming
Battery operated
User-friendly navigation menu
Protective boot with kickstand
For Energy Saving Motor (ESM) based products
Part no.
CBC 000-AF08-01
subject to alterations
Makes quick work of programming the two ESM selectable operating speeds. Eliminates the need for a personal computer, software, power adapter
and 2nd cable. Good for production line or field service use. Automatic shut-off function for an extended battery life. Mini-USB connector for uploading
software upgrades. Batteries, programming cable and operating manual included.
42
Pressure sensor
for pressure-controlled speed control
Material: Housing made of PA
Pressure connection made of brass
Type of protection: IP 65 according to EN 60529 / IEC 529
Suitable for commonly used refrigerants
( R134A; R407C, R404A, R507)
Easy installation via pressure connection with 7/16”-20 UNF female thread with
Schrader valve opener
Power supply via10 VDC
0-10 VDC control output signal for pressure-dependent speed control of the fan
Delivered in individual packaging
A B
Nominal data
Part no.
40100-4-7380
subject to alterations
VDC mA bar bar bar bar °C °C g
10 1 4 to12.5 7.8 30 27 70 -20 to +65 125
Nominal voltage
Max. power input
Setting range
cut-off
Max. medium
temperature
Mass
Factory setting
cut-off
Test pressure
Connecting cable with plug (1.5 m)
not included in scope of delivery.
Part No.: 24010-4-1040
Max. operating
pressure
Perm. amb. temp.
40101-4-7380 10 1 10 to 21 15.5 36 32 70 -20 to +65 125
A
B
3920
48
70
15
(55)
54
4
12
1 = Signal 0-10 V
2 = 10 V
4 = GND
4
1
2
Connection fan
GND
Tacho
10V/PWM
+10V
L
N
PE
Imax=1.1mA
1μF
680R
ZMM47
1
3
2
4
47k 47k
PE1
2AT
AC1 P
AC2 N
Electr. connection:
Pressure sensor
Control voltage
0-10 VDC
Cut-off
Hysteresis
1 bar
Proportional
band
Condensation pressure,
bar
43
Connection lead (Pressure sensor)
Design: Single packed in plastic bag.
6
70±10
1500±20
28.3±0.5
45.5±0.5
31±0.5
Connection line for pressure sensor
Part no.
24010-4-1040
subject to alterations
a
1500
Jacketed cable, internal line
(UL Style 2464), 4 x AWG18
Brass lead tips
44
Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of galvanised or nickel-
plated and passivated steel wire for device fans.
Additional guard grilles that do not conform to DIN EN ISO 13857 are available on request.
Our guard grilles are specially designed for use with ebm-papst fans. Their design ensures
maximum safety with minimum effect on the operating noise level. Note that when using
guard grilles from other manufacturers, compliance with safety-related distances will not
always be present.
Guard grilles (ACi)
ACi 4400 LZ30 Intake side
ACi 4400 LZ30 Outlet side
Fan series Guard grilles
4,3 5
3
+0,2 +1
±0,25
115
153,5
±1
±1
LZ30 Fan size 119 x 119
6
ȯ1,5
Core crimp sleeve Leads end A
10+5
–2
Tin-plated Leads end B
6
ȯ1,5
Core end sleeve Leads end C
Connector cable with injection-moulded plug in various lengths.
Strand ends with core-crimping sleeve, core-end sleeve or tin-plated.
LZ120 610 0,5 mm2straight C black/black 2,8 x 0,5 AC
LZ120-4 2 000 0,5 mm2straight A black/black 2,8 x 0,5 AC
LZ120-16 800 0,5 mm2straight B black/black 2,8 x 0,5 AC
LZ120-18 4 000 0,5 mm2straight A black/black 2,8 x 0,5 AC
LZ126 1 000 0,5 mm2straight C black/black 2,8 x 0,5 AC
LZ127 1 600 0,5 mm2straight B black/black 2,8 x 0,5 AC
LZ130-1 610 0,82 mm2straight C black/black 2,8 x 0,5 AC
Plug model L1 (mm) Leads Plug Leads end Lead colour Receptacle for tabs Application
Connector cables (ACi)
45
FF 119
Filter guard grille consisting of 3 parts: outer grille barrier, inner fastening plate and repla-
ceable filter mat.
Grille barrier made of moulded polycarbonate (PC), with matted surface.
Fast and easy exchange of filter mat via a quick release on the grille barrier.
Fastening plate made of wire netting, with black powder coating.
Filter mat can be replaced while the fan is running, protection provided by welded wire
netting.
Filter mat made of white, synthetically bonded fibres.
Fan filter guard drilles (ACi)
Filter capacity
A fan filter guard filters out up to 75% of
dust particles up to a size of 5-10 microns
and withstands temperatures of up to
100°C. Flame retardant in accordance with
DIN 53438, grade F1. For installed, clean
filters, an air flow reduction of 20 – 30%
can be assumed.
* Replacement filters only in packs of 5.
Fan size: 119 x 119 mm
FF119 119 x 119 mm 162 136 18,5 104,5 RF 119
Protection filter Fan size A B C D Replacement filter*
46
Electrical connections
680 R
Line Connection Colour Assignment / function
1Un +24 VDC red Power supply 24 VDC, residual ripple 3.5 %, see type plate for voltage range
W1G 200 - EF41 - 01 / W1G 200 - EF01 - 01
Customer circuit Connection Fan / Motor
1Tacho white Tacho output: Open Collector, 1 pulse per revolution, Isink max = 10 mA
4
3
2Reverse-polarity
protection
47 V
UB
UN +24 VDC
PWM/0-10 VDC
Tacho
GND
Full
speed
Speed
setting
2
4
4
1
10V -> n = max
1V -> n = min
< 1V -> n = 0
Safe start up at Unom -30%
from 40% PWM
1-10V
Speed
setting via
PWM 1-10kHz
Setting of values via
ebm temperature
controller
2
4
1
33K
12V
100% PWM -> n = max
10% PWM -> n = min
< 10% PWM -> n = 0
Safe start-up at Unom -30%
from 40% PWM
1
No.
1
3
Speed setting with
fixed resistance
4
1
2
4.7K
RE>100K
Tacho
GND1
2
4
1
1PWM / 0-10 VDC yellow Control input PWM or 0-10 V, RE > 100K
1GND blue Reference ground
4
2
10K
OUT
T
PN
47
Imax=1.1mA
100μF
Line Connection Colour Assignment / function
CON10
CON10
W1G 200 - EC87 - A2 / W1G 200 - EC91 - A4
Customer circuit Connection Fan / Motor
CON10
1
3
4
2
680R
ZMM47
1
2
47k 47k
AC1 P
AC2 N
L
N
+10V
10V/PWM
GND
Tacho
max.
speed
Adjustable
speed
50.4
50.3
50.3
50.1
10V -> n = max
1V -> n = min
< 1V -> n = 0
1-10V
Speed
setting via
PWM 1-10kHz
Speed
setting via
potentiometer
50.4
50.3
50.1
10K
15V
50.4
50.3
12V
Imax=10mA
100% PWM -> n = max
10% PWM -> n = min
< 10% PWM -> n = 0
Electrical connections
2
1
1.25A
CON50
No.
1
2
CON50 GND blue GND - Connection for control interface
CON50 0-10V PWM yellow Control input 0 - 10 V or PWM, electrically isolated
CON50 Tacho white Tacho output: Open Collector, 1 pulse per revolution, electrically isolated
CON50 10V/max.1.1mA red Voltage output 10V / 1.1mA, electrically isolated
4
3
2
1
Nblue Neutral conductor
Lblack Power supply 230 VAC, 50 - 60 Hz, see type plate for voltage range
The smart way to save energy
Exchange your old motor for 70 % more efficiency
From the outside, the iQ and iQ² motors are barely distinguishable from conventional shaded-pole
motors. Thus the identical dimensions enable easy replacement without structural modifications or
other obstacles. Axial impellers with diameters from 154 to 300 mm can be installed on the iQ
motor as usual. The same applies to the mounting flange, the wall ring and the guard grille. Thus
the efficiency of many applications can be increased drastically without any development effort.
One design – thousands of applications
Just one design is compatible with the entire range of impellers, from 154 to 300 mm. This makes
logistics easier and keeps your development effort low. Moreover, the smallest size, the iQ 3608, is the
most compact version of an EC motor in the area of refrigeration technology. With an axial installation
depth of only 74 mm, it guarantees the bit of air that is so badly needed in tight spaces.
Energy-saving and quiet – throughout its long service
What all variants have in common is their low-noise performance and very long service life. A critical
role is played by a particularly low-friction bearing system with ball bearings. This enables the
iQ motors to continue to deliver their enormous savings potential for a very long time.
All advantages at a glance
– High efficiency of up to 70 %
– Constant speed, even in the event of voltage fluctuations
– High running smoothness due to low-friction bearing system
– Intelligent electronics with n-control, overload and locked-rotor protection
– Conventional AC technology can be replaced easily
– Identical accessories and dimensions to Q motor
– Long service life due to maintenance-free ball bearings
– One solution replaces multiple sizes of comparable AC motors
Available in 24 V, 115 V and 230 V
Classic shaded-pole motors (Q motors) have reached the end of their usefulness. The new iQ motors
are just as compact, but they are significantly more intelligent, energy-saving and environmentally
friendly. Thanks to ebm-papst GreenTech EC technology, the efficiency has been increased by some
70 %. This means that the switch pays off extremely quickly. And that’s not all: With the additional
functions of the latest iQ² generation, you can increase the efficiency even more with intelligent control
options.
48
The new generation of iQ motors
Quadratic. Practical. Intelligent.
Air performance curves 56
Technical data 52
Savings potential 51
49
50
The smart square:
The new additional functions of the iQ²
The new iQ² motors can do everything the “normal” iQ motors can do – and more, which makes appli-
cations such as those in refrigeration technology more efficient. Additional functions enable different
operating modes, like one that is customised to your needs or automated reverse operation. Simply
select the motor variant that best suits your application.
iQ² safety class II.
The iQ² safety class II features a
special design with plastic housing
parts. This makes extra steps such
as installing the protective earth
conductor (protection class II)
unnecessary – and saves you a lot
of money.
iQ² reverse on start.
The iQ² reverse on start runs back-
wards automatically for a pre-pro-
grammed time at each start-up.
This is an important function for
cooling units, as it allows accumu -
lated dust to be blown from the heat
exchanger of the condenser – for
long-lasting high cooling capacity.
iQ² reverse on demand.
With the iQ² reverse on demand,
you determine the time and
duration of the reverse operation.
For example, you can use the
defrost cycle of the evaporator
to eliminate dust from the heat
exchanger of the condenser.
iQ² two speeds.
The special performance feature of
the iQ² two speeds is its two factory-
programmed speed steps. For ex-
ample, if you want your application
to run in different daytime and
nighttime modes to save additional
energy, it is the right choice.
General overview of data: iQ and iQ²
Material: Die-cast aluminium housing
Direction of air flow: Sucking or blowing
(depending on axial impeller used)
Direction of rotation: Counterclockwise, seen on shaft end
System of protection: IP54
Insulation class: "H"
Mounting position: Any
Mode of operation: Continuous operation (S1)
Bearings: Maintenance-free ball bearings
Motor protection: Via electronics
Electrical connection: Mains cable
Protection class: I, for iQ² plastic housing II on request
Approvals: UL, TÜV in accordance with DIN EN
60335-2-24, DIN EN 60335-2-89,
DIN EN 60075-15, in progress for iQ²
Mounting attachment parts: Guard grille and wall ring are attached
to the projecting thread ends on
the A side
Axial impeller attachment: A plastic adapter with catching peg
and M4 screw is used to secure the
impeller on the motor shaft
51
iQ – Intelligence that pays
A quick example calculation:
A typical supermarket operates 200 AC fans with 200 mm blades (blade angle 28°) in its refrigeration units. If the shaded-pole motors were to be
replaced by iQ or iQ² motors, the energy consumption would be reduced by 39 megawatt hours. That is an annual saving of more than 5.000 euros*
and a good 23 tonnes of CO2.
Reduction in
power input:
70 %
Annual reduction
in energy costs:
5.000 euro total
Annual reduction
in energy consumption:
39 MWh
Annual reduction
in emissions:
23 tonnes CO2
*Assumptions: electricity price 0.13 euros per kWh, continuous operation 24 hours a day, 365 days a year
10
50
100
150
200
2345
0
250
300
350
Consumption [MWh]
Service life [years]
6
iQ 3612
AC-shaded-pole motor
(comparable)
Savings
potential
138 t CO
2
30.600 euro
Electricity price: 0.13 euro per kWh
Number of motors: 200
Continuous operation (24 h/365 d)
Axial blades: 200 mm/28° blade angle
CO
2
emissions factor: 0.596 kg per kWh
(Federal Environment Agency, Dessau, May 2008)
If you look at the figures for the iQ-motor over a prolonged period, its considerable energy-savings potential becomes especially obvious.
iQ motor in energy-saving calculator:
How much energy and money could an iQ motor
save in your company? By what amount could
you decrease CO2emissions in the process?
You can get a good idea of this with the ebm-
papst energy savings calculator at www.green-
tech.info. Go for your energy cost calculation
there and the numbers will speak for them-
selves!
subject to alterations
Nominal data Dimensions
Type V Hz rpm W °C kg abc
220-240 50/60 1300 5 -40..+50 0,5
Nominal voltage
Frequency
Speed/rpm
Output power
Perm. amb. temp.
Mass
83
Ø25,4
Ø3,6
11,5
b
M4
480 / 1000 / 1500
67
M4 (4x)
Ø41
26
51
c
a
15
Standard direction
of rotation
A-side
A-side
B-side
Standard version
52
Technical data
Features
115* 50/60 1550 5 -40..+50 0,5
220-240 50/60 1300 5 -40..+50 0,4
115* 50/60 1550 5 -40..+50 0,4
220-240 50/60 1300 15 -40..+50 0,6
115* 50/60 1550 15 -40..+50 0,6
220-240 50/60 1300 15 -40..+50 0,5
115* 50/60 1550 15 -40..+50 0,5
24 -- 1300 11 -40..+50 0,6
24 -- 400-1300 11 -40..+50 0,6
*With 2 Speeds: upper speed
82 43,5 30,5
220-240 50/60 1300 20 -40..+50 0,8
115* 50/60 1550 20 -40..+50 0,8
220-240 50/60 1300 20 -40..+50 0,7
115* 50/60 1550 20 -40..+50 0,7
24 -- 1300 15,5 -40..+50 0,8
24 -- 400-1300 15,5 -40..+50 0,8
iQ/iQ23608
iQ/iQ23612
iQ/iQ23620
Standard, ROS, ROD, 2 Speeds
Hybrid
Standard, ROS, ROD, 2 Speeds
Hybrid
24 V
Standard, ROS, ROD, 2 Speeds
Hybrid
24 V
74 43,5 30,5
90 51,5 38,5
Mounting bracket
p. 59
Axial impeller
p. 58
Guard grille
p. 60
Basket guard grille
p. 60
Wall ring
p. 61
26
1500
51 48
M4 (4x)
18
43,4
M4
11,5
13
48,9
M4
15
30,5
82
67
83
Ø41
Ø3,6
Ø25,4
Ø71,4
Ø41
3x120°
M4 (3x)
A-side
A-side
B-side
B-side
Depth of screw
max. 5 mm
Multi function version
(only iQ 3612)
53
Standard direction
of rotation
10
200
400
600
234 5
0
800
1000
1200
Speed [rpm]
Control voltage [V]
67 89
24 V version; 400 - 1300 rpm; 0-10 V interface
Speed vs. control voltage:
Power ratings (220 - 240 V design):
Power input and air flow at 230 V / 50 Hz and a constant speed of 1300 min-1.
Axial impeller
diameter
Axial impeller
blade angle
Input power
running at full throttle
Input power
running at free air
iQ/iQ23608
iQ/iQ23612
iQ/iQ23620
mm °
154 22
154 28
154 34
172 22
172 28
172 34
200 22
200 28
mm °
172 28
172 34
200 22
200 28
200 34
230 22
230 28
230 34
254 22
254 * 28
mm °
230 22
230 28
230 34
254 22
254 28
254 * 34
300 * 22
Air flow running
at free air
at n=1300 rpm
WWm
3/h
3,0 2,0 170
3,8 2,8 190
4,1 3,3 220
4,6 2,6 230
6,1 3,8 270
7,8 5,0 310
9,2 4,5 360
9,2 5,5 410
WWm
3/h
4,2 2,9 270
5,7 3,8 310
5,1 3,4 360
8,3 5,3 410
12,1 7,3 470
9,6 6,0 520
19,0 13,1 710
20,5 16,9 750
21,2 11,3 710
19,3 21,2 980
WWm
3/h
16,1 8,3 520
21,2 11,9 710
25,0 13,9 750
26,5 12,3 710
27,4 23,1 980
25,7 28,4 1010
23,7 24,3 1380
Curves
Motor
A
B
C
B
D
E
F
subject to alterations * Depending on back pressure, full nominal speed of 1300 min-1 is not reached to some part. Depending on mounting situation and version, a speed of approx. 1200 min-1 (+/- 100 min-1) is reached. Due to the
intelligent electronics, however, safe (permanent) operation is still guaranteed.
54
iQ/iQ2-motor – combination with axial impellers
Power input and air flow
E
G
H
Mounting bracket
p. 59
Axial impeller
p. 58
Guard grille
p. 60
Basket guard grille
p. 60
Wall ring
p. 61
55
iQ/iQ2-motor
Air performance curves measured in wall ring, at a constant speed of 1,300 rpm.
50 100 150 200 250
10
20
30
40
50
60
70
80
90
22° 28° 34°
qV
pfs Pa
m3/h 50 100 150 200 250 300
10
20
30
40
50
22° 28° 34°
qV
pfs Pa
m3/h
iQ/iQ23608, Ø 154 iQ/iQ23608 / 3612, Ø 172
50 100 150 200 250 300 350
10
20
30
40
50
22° 28°
qV
pfs Pa
m3/h 100 200 300 400
10
20
30
40
50
60
70
22° 28° 34°
qV
pfs Pa
m3/h
iQ/iQ23608, Ø 200 iQ/iQ23612, Ø 200
A B
C D
56
100 200 300 400 500 600 700
10
20
30
40
50
60
70
80
22° 28° 34°
qV
pfs Pa
m3/h 200 400 600 800
20
40
60
80
100
22° 28°
qV
pfs Pa
m3/h
iQ/iQ23612 / 3620, Ø 230 iQ/iQ23612, Ø 254
200 400 600 800
20
40
60
80
100
22° 28° 34°
qV
pfs Pa
m3/h 200 400 800600 1000 1200
20
40
60
100
80
22°
qV
pfs Pa
m3/h
iQ/iQ23620, Ø 254 iQ/iQ23620, Ø 300
E F
G H
57
Axial impellers
58
a
6,6
c
b
c
b Material: Sheet aluminium
Axial impellers
Part no. for dir. of air flow "V" Part no. for dir. of air flow "A"
27453.34001 27453.34201
subject to alterations
Blade angle
α
abc
154,0 27,5 14,022° ± 1°30’
27453.34002 27453.34202 154,0 32,0 16,028° ± 1°30’
27453.34003 27453.34203 154,0 37,0 18,034° ± 1°30’
22° ± 1°30’
28° ± 1°30’
34° ± 1°30’
22° ± 1°30’
28° ± 1°30’
34° ± 1°30’
22° ± 1°30’
28° ± 1°30’
34° ± 1°30’
22° ± 1°30’
28° ± 1°30’
34° ± 1°30’
22° ± 1°30’
27453.34004 27453.34204 172,0 31,0 14,5
27453.34005 27453.34205 172,0 36,0 17,0
27453.34006 27453.34206 172,0 42,0 21,0
27453.34007 27453.34207 200,0 32,0 15,5
27453.34008 27453.34208 200,0 37,5 18,0
27453.34009 27453.34209 200,0 45,0 22,0
27453.34010 27453.34210 230,0 35,0 17,5
27453.34011 27453.34211 230,0 43,0 21,5
27453.34012 27453.34212 230,0 50,0 24,0
27453.34013 27453.34213 254,0 37,0 19,0
27453.34014 27453.34214 254,0 45,0 23,5
27453.34015 27453.34215 254,0 52,0 26,0
27453.34016 27453.34216 300,0 43,0 21,5
Direction of rotation
4 x Ø 4.0 with pitch circle for holes Ø 25.4 mm
"V" "A"
28° ± 1°30’27453.34017 27453.34217 300,0 53,5 26,5
34° ± 1°30’27453.34018 27453.34218 300,0 61,0 30,0
Mounting bracket
Mounting bracket - foot measure 18 mm (multi-function design)
Part no. abcd
27452.71002 56,0 51,0 78,0 100,0
subject to alterations
Material: Sheet steel, galvanized and blue
chromated
Size
172
Vers.
1
1
1
2
3
27452.71005 67,0 51,0 78,0 100,0200
27452.71003 74,5 51,0 78,0 100,0230
27452.71004 85,5 51,0 78,0 100,0254
27452.71001 112,0 150,0 172,0300
Mounting bracket - foot measure 26 mm (standard design or multi-function design)
Part no. a
27452.71201 39,0
subject to alterations
Material: Sheet steel, galvanized and blue
chromated
Size
154
Vers.
1
1
1
1
2
27452.71202 52,0172
27452.71203 72,0200
1 72,0230
27452.71204 84,0254
27452.71205 84,0254
227452.71206 109,0300
327452.71207 109,0300
2,5
c
d
b
18
4,3
14
8,2
8
25
a
2,5
c
d
b
18
a
26
109°
14
8,2
18
4,3
25
16
6,2
16,2
5
18
4,2
40
24
18
2,5
a
51
78
100
26
4,3
1,5
8,2
14
24
2,5
a
51
78
100
26
4,3
21
40
14
8
8,2
2,5
a
51
78
100
26
4,3
8,2
14
7
31,8
13
50,3
Vers. 1 Vers. 2 Vers. 3
Vers. 1 Vers. 2 Vers. 3
59
Guard grille
Part no. abc
27452.70002 170,0 190,0 11,5
subject to alterations
2,7
c
Øa
5
b
94,5
Material: Steel, galvanized and blue
chromated
Guard grille
Max. blade angle
α
at "V"
34°
Max. blade angle
α
at "A"
34°
Size
154
27452.70003 188,0 208,0 11,534° 34°172
27452.70004 214,0 236,0 11,534° 28°200
27452.70005 246,0 266,0 17,528° 28°230
27452.70006 270,0 290,0 17,528° 28°254
27452.70007 324,0 344,0 17,5 22°300
Basket guard grille
Part no. abc
27452.70201
subject to alterations
Øa
Øb
c
94,5
5
2,7
92
Material: Steel, galvanized and blue
chromated
Max. blade angle
α
at "V" Max. blade angle
α
at "A"
Size
27452.70202
188,0 208,0 37,534° 34°172
27452.70203
212,0 236,0 37,534° 28°200
27452.70204
246,0 266,0 40,028° 28°230
270,0 290,0 40,028° 28°254
27452.70205 324,0 344,0 46,8 22°300
60
Wall rings, direction of air flow "V"
Part no. (sheet steel) a b c d d (plastic)
27452.70501 164,0 190,0 200,0 24,0 26,0
subject to alterations
4,3
b
67
4,3
c
2
48
R3,5
d
67
1
Øa
Material: Sheet steel, coated in grey plastic
Wall rings
Max. blade angle
α
34°
Size
154
27452.70502 182,0 208,0 223,0 24,0 26,034°172
27452.70503 210,0 236,0 246,0 24,0 26,034°200
27452.70504 240,0 266,0 276,0 24,0 ---28°230
27452.70505 264,0 290,0 300,0 24,0 26,028°254
27452.70506 308,0 344,0 356,0 24,0 26,022°300
Wall rings, direction of air flow "A"
Part no. (sheet steel) a b c d d (plastic)
27452.70701 162,0 190,0 200,0 24,0 ---
subject to alterations
Max. blade angle
α
34°
Size
154
27452.70702 180,0 208,0 223,0 24,0 ---34°172
27452.70703 208,0 236,0 246,0 24,0 ---28°200
27452.70704 238,0 266,0 276,0 24,0 ---28°230
27452.70705 262,0 290,0 300,0 24,0 26,028°254
27452.70706 308,0 344,0 356,0 24,0 ---22°300
4,3
b
c
67
67
4,3
36
R4,5
2
d
Øa
1
Material: Sheet steel, coated in grey plastic
61
"V"
"A"
Part no. (plastic)
27452.70802
27452.70803
27452.70804
---
27452.70805
27452.70806
Part no. (plastic)
---
---
---
---
27452.70807
---
62
Technical parameters & scope
High standards for all ebm-papst products
Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best
possible product for your application. Careful monitoring of the market ensures that technical innovations are
reflected in the improvements of our products.
Based on the technical parameters listed below and the ambience you want our product to operate in,
we here at ebm-papst can always work out the best solution for your specific application.
General performance parameters
Any deviations from the technical data and parameters described here
are listed on the product-specific data sheet.
Type of protection
The type of protection is specified in the product-specific data sheets.
Insulation class
The insulation class is specified in the product-specific data sheets.
Mounting position
The mounting position is specified in the product-specific data sheets.
Condensate discharge holes
Information on the condensate discharge holes is provided in the
product-specific data sheets.
Mode of operation
The mode of operation is specified in the product-specific data sheets.
Protection class
The protection class is specified in the product-specific data sheets.
Service life
The service life of ebm-papst products depends on two major factors:
The service life of the insulation system
The service life of the bearing system
The service life of the insulation system mainly depends on voltage level,
temperature and ambient conditions, such as humidity and condensation.
The service life of the bearing system depends mainly on the thermal load
on the bearing.
The majority of our products use maintenance-free ball bearings for
any mounting position possible. As an option, sleeve bearings can be
used, which is indicated on the product-specific data sheet wherever
applicable.
The service life L10 of the ball bearings can be taken as approx. 40,000
operating hours at an ambient temperature of 40 °C, yet this estimate
can vary according to the actual ambient conditions.
We will gladly provide you with a lifetime calculation taking into account
your specific operating conditions.
Motor protection / thermal protection
Information on motor protection and thermal protection is provided in the
product-specific data sheets.
Depending on motor type and field of application, the following protective
features are realised:
Thermal overload protection (TOP), either in-circuit or external
PTC with electronic diagnostics
Impedance protection
Thermal overload protection (TOP) with electronic diagnostics
Current limitation via electronics
If an external TOP is connected, the customer has to make sure to
connect a conventional trigger device for switching it off.
Products without fitted TOP and without protection against improper use,
a motor protection complying with the valid standards has to be installed.
63
Legal and normative directives
The products described in this catalogue are designed, developed and
produced in keeping with the standards in place for the relevant product
and, if known, the conditions governing the relevant fields of application.
Standards
Information on standards is provided in the product-specific data sheets.
EMC
Information on EMC standards is provided in the product-specific data
sheets.
Complying with the EMC standards has to be established on the final
appliance, as different mounting situations can result in changed EMC
properties.
Leakage current
Information on the leakage current is provided in the product-specific
data sheets.
Measuring is according to IEC 60990.
Approvals
In case you require a specific approval for your ebm-papst product
(VDE, UL, GOST, CCC, CSA, etc.) please let us know.
Most of our products can be supplied with the relevant approval.
Information on existing approvals is provided in the product-specific
data sheets.
Air performance measurements
All air performance measurements are carried out on suction side and on
chamber test beds conforming to the specifications as per ISO 5801 and
DIN 24163. The fans under test are installed in the measuring chamber at
free air intake and exhaust (installation category A) and are operated at
nominal voltage, with AC also at nominal frequency, and without any
additional components such as guard grilles.
As required by the standard, the air performance curves correspond to
an air density of 1.2 kg/m3.
Left: Endurance test room
Middle: Shock test
Right: Chamber test rig
Mechanical strain / performance parameters
All ebm-papst products are subjected to comprehensive tests complying
with the normative specifications. In addition to this, the tests also reflect
the vast experience and expertise of ebm-papst.
Vibration test
Vibration tests are carried out in compliance with
Vibration test in operation according to DIN IEC 68, parts 2-6
Vibration test at standstill according to DIN IEC 68, parts 2-6
Shock load
Shock load tests are carried out in compliance with
Shock load according to DIN IEC 68, parts 2-27
Balancing quality
Testing the balancing quality is carried out in compliance with
Residual imbalance according to DIN ISO 1940
Standard balancing quality level G 6.3
Should you require a higher balancing quality level for your specific
application, please let us know and specify this when ordering your
product.
Chemo-physical strain / performance parameters
Should you have questions about chemo-physical strain, please direct
them to your ebm-papst contact.
Fields of application, industries and applications
Our products are used in various industries and applications:
Ventilation, air-conditioning and refrigeration technology, clean room
technology, automotive and rail technology, medical and laboratory tech -
nology, electronics, computer and office technology, telecommunications,
household appliances, heating, machines and plants, drive engineering.
Our products are not designed for use in the aviation and aerospace
industry!
64
Measurement conditions for air and noise measurement
ebm-papst products are measured under the following conditions:
Axial and diagonal fans in direction of rotation “V” in full nozzle and
without guard grille
Backward curved centrifugal fans, free-running and with inlet nozzle
Forward curved single and dual inlet centrifugal fans with housing
Noise measurements
All noise measurements are carried out in low-reflective test rooms with
reverberant floor. Thus the ebm-papst acoustic test chambers meet the
requirements of precision class 1 according to DIN EN ISO 3745. For noise
measurement, the fans being tested are placed in a reverberant wall and
operated at nominal voltage (for AC, also at nominal frequency) without
additional attachments such as the guard grille.
Sound pressure level and sound level
All acoustic values are established according to ISO 13347, DIN 45635
and ISO 3744/3745 to accuracy class 2 and given in A-rated form.
When the sound pressure level (Lp) is measured, the microphone is on
the intake side of the fan being tested, usually at a distance of 1 m on
the fan axis.
To measure the sound power level (Lw), 10 microphones are distributed
over an enveloping surface on the intake side of the fan being tested
(see graphic). The sound power level measured can be roughly calculated
from the sound pressure level by adding 7 dB.
Measuring configuration as per ISO 13347-3 respectively DIN 45635-38:
10 measuring points
d D
h = 1,5d ... 4,5d
Measurement area S = 6d2+ 7d (h + 1,5d)
3d
2d
h
D
1,5d
Room for precision noise measuring
65
Combined level of multiple same-level sound sources
Adding 2 noise sources with the same level results in a level increase of approx. 3 dB.
The noise characteristics of multiple identical fans can be determined in advance based on
the noise values specified in the data sheet. This is shown in the diagram opposite.
Example: 8 A3G800 axial fans are on a condenser. According to the data sheet, the sound
pressure level of a fan is approximately 75 dB(A). The level increase measured from the dia-
gram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A).
Combined level of two different-level sound sources
The acoustic performance of two different fans can be predetermined based on the sound
levels given in the data sheet. This is shown in the diagram opposite.
Example: There is an axial fan A3G800 with a sound pressure level of 75 dB(A) at the oper-
ating point and an axial fan A3G710 with 71 dB(A) in a ventilation unit. The level difference is
4 dB. The level increase can now be read in the diagram as approx. 1.5 dB. This means that
the overall sound level of the unit can be expected to be 76.5 dB(A).
Distance laws
Sound power level is independent of distance to the sound source. In contrast to this, sound
pressure level decreases the further away the noise source is. The adjacent diagram shows
the decrease in level under far sound field conditions. Far sound field conditions apply when-
ever the distance between microphone and fan is big when compared to fan diameter and
wavelength to be considered. For more information on far sound field, please consult the rele-
vant literature on this complex topic. Per doubling of distance, the level in the far sound field
decreases by 6 dB. In the near field of the fan, other correlations apply and the decrease in
levels can be considerably smaller. The following example only applies to far sound field
conditions and can vary strongly depending on the installation effects:
With an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of
1 m. According to the adjacent diagram, at a distance of 20 m we would get a reduction by
26 dB, i.e. a sound pressure level of 39 dB(A).
15
10 15 20 255 82 3
105 90
1
Number of sources of sound with identical level
Increase in sound pressure / sound power level
4 6 7 9
[dB]
[dB(A)]
3
12 16 20 2484
21 1,50
0
Difference in level with two sources of sound
Increase in sound pressure / sound power level [dB]
[dB(A)]
[dB]
[dB(A)]
0
10 20 50 10052
-10-26 -20-30-40
1
[m]
Distance
Decrease in sound pressure level [dB]
[dB(A)]
66
ebm-papst in Germany
Germany
ebm-papst
Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
ebm-papst
St. Georgen GmbH & Co. KG
Hermann-Papst-Straße 1
D-78112 St. Georgen
Phone +49 7724 81-0
Fax +49 7724 81-1309
info2@de.ebmpapst.com
www.ebmpapst.com
ebm-papst
Landshut GmbH
Hofmark-Aich-Straße 25
D-84030 Landshut
Phone +49 871 707-0
Fax +49 871 707-465
info3@de.ebmpapst.com
www.ebmpapst.com
fan agent
compact fan agent
motor specialist
motor agent
Heilbronn / Heidelberg
Dipl.-Ing. Mark Gartner
Gehrweg 12
D-74199 Unterheinriet
Phone +49 7130 404569-1
Fax +49 7130 404569-2
Mark.Gartner@de.ebmpapst.com
Kassel
Dipl.-Ing. (FH) Ralph Brück
Hoherainstraße 3 b
D-35075 Gladenbach
Phone +49 6462 4071-10
Fax +49 6462 4071-11
Ralph.Brueck@de.ebmpapst.com
Koblenz
Winfried Schaefer
Hinter der Kirch 10
D-56767 Uersfeld
Phone +49 2657 16-96
Fax +49 2657 16-76
Winfried.Schaefer@de.ebmpapst.com
Munich
Dipl.-Wirt.-Ing. (FH) Jens Peter
Landsbergerstraße 14
D-86932 Pürgen
Phone +49 8196 99877-54
Fax +49 8196 99877-55
Jens.Peter@de.ebmpapst.com
Nuremberg
Dipl.-Wirt.-Ing. (FH) Axel Resch
Dr.-August-Koch-Str. 1
D-91639 Wolframs-Eschenbach
Phone +49 9875 9783-170
Fax +49 9875 9783-171
Axel.Resch@de.ebmpapst.com
Offenburg
Dipl.-Ing. (FH) Ralf Braun
Hubeneck 21
D-77704 Oberkirch
Phone +49 7802 9822-52
Fax +49 7802 9822-53
Ralf.Braun@de.ebmpapst.com
Stuttgart
Dipl.-Ing. (FH) Rudi Weinmann
Hindenburgstraße 100/1
D-73207 Plochingen
Phone +49 7153 9289-80
Fax +49 7153 9289-81
Rudi.Weinmann@de.ebmpapst.com
Ulm
M.Sc. Reinhard Sommerreißer
Am Silbermannpark 10
D-86161 Augsburg
Phone +49 821 6610-7023
Fax +49 821 6610-7024
Reinhard.Sommerreisser@de.ebmpapst.com
Distributors
Frankfurt
R.E.D. Handelsgesellschaft mbH
Gutenbergstraße 3
D-63110 Rodgau - Jügesheim
Phone +49 6106 841-0
Fax +49 6106 841-111
info@red-elektromechanik.de
www.red-elektromechanik.de
Hamburg
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 48
D-22339 Hamburg
Phone +49 40 538092-20
Fax +49 40 538092-84
info@breuell-hilgenfeldt.de
Munich
A. Schweiger GmbH
Ohmstraße 1
D-82054 Sauerlach
Phone +49 8104 897-0
Fax +49 8104 897-90
info@schweiger-gmbh.de
www.schweiger-gmbh.com
(1 to 5 pieces)
North
Breuell + Hilgenfeldt GmbH
Grützmühlenweg 48
D-22339 Hamburg
Phone +49 40 538092-20
Fax +49 40 538092-84
ebmpapst@breuell-hilgenfeldt.de
South
HDS Ventilatoren Vertriebs GmbH
Glaswiesenstraße 1
D-74677 Dörzbach
Phone +49 7937 80355-20
Fax +49 7937 80355-25
info@hds-gmbh.net
www.hds-gmbh.net
Berlin
Dipl.-Ing. (TH) Jens Duchow
Händelstraße 7
D-16341 Panketal
Phone +49 30 944149-62
Fax +49 30 944149-63
Jens.Duchow@de.ebmpapst.com
Bielefeld
Dipl.-Ing. (FH) Wolf-Jürgen Weber
Niehausweg 13
D-33739 Bielefeld
Phone +49 5206 91732-31
Fax +49 5206 91732-35
Wolf-Juergen.Weber@de.ebmpapst.com
Dortmund
Dipl.-Ing. (FH) Hans-Joachim Pundt
Auf den Steinern 3
D-59519 Möhnesee-Völlinghausen
Phone +49 2925 800-407
Fax +49 2925 800-408
Hans-Joachim.Pundt@de.ebmpapst.com
Frankfurt
Dipl.-Ing. Christian Kleffmann
Dr.-Hermann-Krause-Straße 23
D-63452 Hanau
Phone +49 6181 1898-12
Fax +49 6181 1898-13
Christian.Kleffmann@de.ebmpapst.com
Halle
Dipl.-Ing. (TU) Michael Hanning
Lercheneck 4
D-06198 Salzatal / OT Lieskau
Phone +49 345 55124-56
Fax +49 345 55124-57
Michael.Hanning@de.ebmpapst.com
Hamburg
Ingenieurbüro Breuell GmbH
Ing. Dirk Kahl
Elektroingenieur
Grützmühlenweg 48
D-22339 Hamburg
Phone +49 40 538092-19
Fax +49 40 538092-84
Dirk.Kahl@de.ebmpapst.com
67
ebm-papst in Europe
Europe
Austria
ebm-papst Motoren & Ventilatoren GmbH
Straubingstraße 17
A-4030 Linz
Phone +43 732 321150-0
Fax +43 732 321150-20
info@at.ebmpapst.com
www.ebmpapst.at
Belarus
ebm-papst Bel AgmbH
P.O. Box 117
BY-220138 Minsk
Phone +375 17 3851556
Fax +375 17 3851556
info@by.ebmpapst.com
www.ebmpapst.by
Belgium
ebm-papst Benelux B.V.
Sales office Belgium-Luxemburg
Romeinsestraat 6/0101
Research Park Haasrode
B-3001 Heverlee-Leuven
Phone +32 16 396-200
Fax +32 16 396-220
info@be.ebmpapst.com
www.ebmpapst.be
Bulgaria
ebm-papst Romania S.R.L.
Str. Tarnavei No. 20
RO-500327 Brasov
Phone +40 268 331859
Fax +40 268 312805
dudasludovic@xnet.ro
Croatia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Czech Republic / Slovakia
ebm-papst CZ s.r.o.
Kaštanová 34a
CZ-620 00 Brno
Phone +420 544 502-411
Fax +420 547 232-622
info@ebmpapst.cz
www.ebmpapst.cz
Denmark
ebm-papst Denmark ApS
Vallensbækvej 21
DK-2605 Brøndby
Phone +45 43 631111
Fax +45 43 630505
mail@dk.ebmpapst.com
www.ebmpapst.dk
Estonia
ebm-papst Oy, Eesti Filiaal
Kesk tee 13
Aaviku küla, Jüri Tehnopark
EST-75301 Rae Vald, Harjumaa
Phone +372 65569-78
Fax +372 65569-79
www.ebmpapst.ee
Finland
ebm-papst Oy
Puistotie 1
FIN-02760 Espoo
Phone +358 9 887022-0
Fax +358 9 887022-13
mailbox@ebmpapst.fi
www.ebmpapst.fi
France
ebm-papst sarl
ZI Nord - rue A. Mohler
BP 62
F-67212 Obernai Cedex
Phone +33 820 326266
Fax +33 3 88673883
info@ebmpapst.fr
www.ebmpapst.fr
Greece
Helcoma
Th. Rotas & Co OE
Davaki 65
GR-17672 Kallithea-Attiki
Phone +30 210 9513-705
Fax +30 210 9513-490
contact@helcoma.gr
www.helcoma.gr
Hungary
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Iceland
RJ Engineers
Stangarhyl 1a
IS-110 Reykjavik
Phone +354 567 8030
Fax +354 567 8015
rj@rj.is
www.rj.is
Ireland
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 1245 468555
Fax +44 1245 466336
sales@uk.ebmpapst.com
www.ebmpapst.co.uk
AuBren Limited
Portlaoise Business & Technology Park
Mountrath Road
IRL-Portlaoise, Co. Laois
Phone +353 57 8664343
Fax +353 57 8664346
sales@ie.aubren.com
www.aubren.com
Italy
ebm-papst Srl
Via Cornaggia 108
I-22076 Mozzate (Co)
Phone +39 0331 836201
Fax +39 0331 821510
info@it.ebmpapst.com
www.ebmpapst.it
Macedonia
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
68
fan agent
compact fan agent
motor specialist
motor agent
ebm-papst in Europe
Russia
ebm-papst Ural GmbH
Posadskaja-Strasse, 23(E), 3
RU-620102 Ekaterinburg
Phone +7 343 2338000
Fax +7 343 2337788
Konstantin.Molokov@ru.ebmpapst.com
www.ebmpapst.ur.ru
ebm-papst Rus GmbH
proezd 4529, vladenie 5, stroenie 1
RU-141000 Mytistschi, Oblast Moskau
Phone +7 495 9807524
Fax +7 495 5140924
info@ebmpapst.ru
www.ebmpapst.ru
Serbia & Montenegro
ebm-papst Industries Kft.
Ezred u. 2.
H-1044 Budapest
Phone +36 1 8722-190
Fax +36 1 8722-194
office@hu.ebmpapst.com
Spain
ebm-papst Ibérica S.L.
Avda. del Sistema Solar, 29
E-28830 San Fernando de Henares (Madrid)
Phone +34 91 6780894
Fax +34 91 6781530
ventas@ebmpapst.es
www.ebmpapst.es
Sweden
ebm-papst AB
Äggelundavägen 2
S-17562 Järfälla
Phone +46 10 4544400
Fax +46 8 362306
info@ebmpapst.se
www.ebmpapst.se
Switzerland
ebm-papst AG
Rütisbergstrasse 1
CH-8156 Oberhasli
Phone +41 44 73220-70
Fax +41 44 73220-77
verkauf@ebmpapst.ch
www.ebmpapst.ch
Turkey
Akantel Elektronik San. Tic. LTD. Sti.
Atatürk Organize Sanayi
Bölgesi 10007 SK. No.:6
TR-35620 Cigli-Izmir
Phone +90 232 3282090
Fax +90 232 3280270
akantel@akantel.com.tr
www.ebmpapst.com.tr
Ukraine
ebm-papst Ukraine LLC
Lepse Boulevard, 4, Building 21
UA-03067 Kiev
Phone +38 044 2063091
Fax +38 044 2063091
mail@ebmpapst.ua
www.ebmpapst.ua
United Kingdom
ebm-papst UK Ltd.
Chelmsford Business Park
GB-Chelmsford Essex CM2 5EZ
Phone +44 1245 468555
Fax +44 1245 466336
sales@uk.ebmpapst.com
www.ebmpapst.co.uk
ebm-papst Automotive & Drives (UK) Ltd.
The Smithy
Fidlers Lane
GB-East Ilsley, Berkshire RG20 7LG
Phone +44 1635 2811-11
Fax +44 1635 2811-61
A&Dsales@uk.ebmpapst.com
www.ebmpapst-ad.com
Netherlands
ebm-papst Benelux B.V.
Engelseweg 127
NL-5705 AC Helmond
Phone +31 492 502-900
Fax +31 492 502-950
verkoop@nl.ebmpapst.com
www.ebmpapst.nl
Norway
ebm-papst AS
P.B. 173 Holmlia
N-1203 Oslo
Phone +47 22 763340
Fax +47 22 619173
mailbox@ebmpapst.no
www.ebmpapst.no
Poland
ebm-papst Polska Sp. z o.o.
ul. Annopol 4A
PL-03236 Warszawa
Phone +48 22 6757819
Fax +48 22 6769587
office@ebmpapst.pl
www.ebmpapst.pl
Portugal
ebm-papst (Portugal), Lda.
Centro Empresarial de Alverca
Rua de Adarse, Vale D’Ervas
Corpo D / Fracção 3
P-2615-178 Alverca do Ribatejo
Phone +351 218 394 880
Fax +351 218 394 759
info@pt.ebmpapst.com
www.ebmpapst.pt
Romania
ebm-papst Romania S.R.L.
Str. Tarnavei Nr. 20
RO-500327 Brasov
Phone +40 268 331859
Fax +40 268 312805
dudasludovic@xnet.ro
69
ebm-papst in America and Africa
America
Argentina
ebm-papst de Argentina S.A.
Hernandarias 148 Lomas del Mirador
Pcia. de Buenos Aires (1752)
Phone +54 11 46576135
Fax +54 11 46572092
ventas@ar.ebmpapst.com
www.ebmpapst.com.ar
Brazil
ebm-papst Motores Ventiladores Ltda.
Av. José Giorgi, 301 Galpões B6+B7
Condominio Logical Center
BR-06707-100 Cotia - São Paulo
Phone +55 11 4613-8700
Fax +55 11 4777-1456
vendas@br.ebmpapst.com
www.ebmpapst.com.br
Canada
ebm-papst Canada Inc.
1800 Ironstone Manor, Unit 2
CDN-Pickering, Ontario, L1W3J9
Phone +1 905 420-3533
Fax +1 905 420-3772
sales@ca.ebmpapst.com
www.ebmpapst.ca
Mexico
ebm Industrial S. de R.L. de C.V.
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
MEX-Mexico 05120, D.F.
Phone +52 55 3300-5144
Fax +52 55 3300-5243
sales@mx.ebmpapst.com
www.ebmpapst.com.mx
USA
ebm-papst Inc.
P.O. Box 4009
100 Hyde Road
USA-Farmington, CT 06034
Phone +1 860 674-1515
Fax +1 860 674-8536
sales@us.ebmpapst.com
www.ebmpapst.us
ebm-papst Automotive & Drives, Inc.
3200 Greenfield, Suite 255
USA-Dearborn, MI 48120
Phone +1 313 406-8080
Fax +1 313 406-8081
automotive@us.ebmpapst.com
www.ebmpapst-automotive.us
Africa
South Africa
ebm-papst South Africa (Pty) Ltd.
P.O. Box 3124
1119 Yacht Avenue
ZA-2040 Honeydew
Phone +27 11 794-3434
Fax +27 11 794-5020
info@za.ebmpapst.com
www.ebmpapst.co.za
70
fan agent
compact fan agent
motor specialist
motor agent
ebm-papst in Asia and Australia
Asia
China
ebm-papst Ventilator (Shanghai) Co., Ltd.
No. 418, Huajing Road
WaiGaoQiao Free Trade Zone
No. 2001, Yang Gao (N) Road
VRC-200131 Shanghai, P.R. of China
Phone +86 21 5046-0183
Fax +86 21 5046-1119
sales@cn.ebmpapst.com
www.ebmpapst.com.cn
Hong Kong
ebm-papst Hong Kong Ltd.
Unit No. 13,9 / F
Technology Park, 18 On Lai Street
Siu Lek Yuen, Shatin N.T.
Hong Kong - P.R. of China
Phone +852 2145-8678
Fax +852 2145-7678
info@hk.ebmpapst.com
India
ebm-papst India Pvt. Ltd.
26/3, G.N.T. Road, Erukkencherry
IND-Chennai-600118
Phone +91 44 25372556
Fax +91 44 25371149
sales@in.ebmpapst.com
www.ebmpapst.in
Indonesia
ebm-papst Indonesia
Representative Office
German Centre, 4th Floor, Suite 4470
Jl. Kapt. Subijono Dj. Bumi Serpong Damai
RI-15321 Tangerang
Phone +62 21 5376250
Fax +62 21 5388305
salesdept@id.ebmpapst.com
Israel
Polak Bros. Import Agencies Ltd.
9 Hamefalsim Street
IL-Kiryat Arie, Petach-Tikva 49514
Phone +972 3 9100300
Fax +972 3 5796679
polak@polak.co.il
www.polak.co.il
Japan
ebm-papst Industries Japan K.K.
12th Floor, Benex S-3 Bldg.
3-20-8 Shinyokohama, Kohoku-ku
J-222-0033 Yokohama
Phone +81 45 47057-51
Fax +81 45 47057-52
info@jp.ebmpapst.com
www.ebmpapst.jp
Korea
ebm-papst Korea Co. Ltd.
6F, Trutec Bldg.
B 6-2, Digital Media City (DMC)
Sangam-Dong, Mapo-Gu
ROK-Seoul 121-270
Phone +82 2 366213-24
Fax +82 2 366213-26
info@kr.ebmpapst.com
www.ebmpapst.co.kr
Malaysia
ebm-papst Malaysia
Representative Office
Unit 12-2, Jalan USJ Sentral 3
Persiaran Subang, Selangor Darul Ehsan
MAL-47600 Subang Jaya
Phone +60 3 8024-1680
Fax +60 3 8024-8718
salesdept@my.ebmpapst.com
Singapore
ebm-papst SEA Pte. Ltd.
No. 23 Ubi Road 4
#06-00 Olympia Industrial Building
SGP-Singapore 408620
Phone +65 65513789
Fax +65 68428439
salesdept@sg.ebmpapst.com
Taiwan
ETECO Engineering & Trading Corp.
10F-I, No. 92, Teh-Wei Str.
RC-Tsow-Inn District, Kaohsiung
Phone +886 7 557-4268
Fax +886 7 557-2788
eteco@ms22.hinet.net
www.ebmpapst.com.tw
Thailand
ebm-papst Thailand Co., Ltd.
99/9 Moo 2, Central Chaengwattana Tower
14th Floor, Room 1402
Chaengwattana Road Bangtarad, Pakkret
THA-11120 Nonthaburi
Phone +66 2 8353785-7
Fax +66 2 8353788
salesdept@th.ebmpapst.com
United Arab Emirates
ebm-papst Middle East FZE
PO Box 17755
Jebel Ali Free Zone / FZS1 / AP05
UAE-Dubai
Phone +971 4 88608-26
Fax +971 4 88608-27
info@ae.ebmpapst.com
www.ebmpapst.ae
Vietnam
ebm-papst Vietnam
Representative Office
Room #102, 25 Nguyen Van Thu Street
District 1
VN-Ho Chi Minh City
Phone +84 8 39104099
Fax +84 8 39103970
linh.nguyen@vn.ebmpapst.com
71
Australia
Australia
ebm-papst A&NZ Pty Ltd.
10 Oxford Road
AUS-Laverton North, Victoria, 3026
Phone +61 3 9360-6400
Fax +61 3 9360-6464
sales@ebmpapst.com.au
www.ebmpapst.com.au
New Zealand
ebm-papst A&NZ Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 9 837-1884
Fax +64 9 837-1899
sales@ebmpapst.com.au
www.ebmpapst.com.au
ebm-papst
Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
ebm-papst
Landshut GmbH
Hofmark-Aich-Straße 25
D-84030 Landshut
Phone +49 871 707-0
Fax +49 871 707-465
info3@de.ebmpapst.com
www.ebmpapst.com
ebm-papst
St. Georgen GmbH & Co. KG
Hermann-Papst-Straße 1
D-78112 St. Georgen
Phone +49 7724 81-0
Fax +49 7724 81-1309
info2@de.ebmpapst.com
37804-7-8811 · 2012-10 · KD-3’
Printed in Germany
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
ebm-papst:
10637-4-1040 10640-4-1040 10638-4-1040 FF119 RF119