HMI Components Edition 01/2016 Series 02 Characteristics Functions Market segments The robust Series 02 is especially suited for: The Series 02 incorporates the following functions: The EAO Series 02 is especially suited for applications in the segments: Flush design The rectangular construction (24 x 36 mm) provides large surfaces for illumination and labelling. Indicator Pushbutton Illuminated pushbutton Keylock switch Buzzer Ship building Panel building Please refer to the EAO website to obtain detailed information regarding this series www.products.eao.com Configure a product to your exact needs and request a quotation. Content 02 Overview Flush design Indicator 4 Buzzer 5 Pushbutton 6 Illuminated pushbutton 7 Mushroom-head pushbutton 8 Keylock switch 9 Mushroom-head keylock pushbutton 10 Accessories 11 Technical data 21 Marking 23 Application guidelines 24 Index 25 3 02 Flush design Indicator, IP 40 10 max. 37.6 x 23.5 Equipment consisting of (schematic overview) 84 7 Product can differ from the current configuration. Front bezel page 13 Lens page 11 LED page 17 Dimensions [mm] Actuator Additional Information For indicator 02-07x.00x can only filament lamps be used (no LEDs) * For LED element fitting information see chapter Application guidelines * Take note of heat generating 3NBY Fixing bezel NJO * NJO For front dimension 24 x 36 mm * Each article number listed below includes all the black components shown in the 3D-drawing. To obtain a complete unit, please select the red components from the pages shown. Behind panel depth Terminal Part No. Wiring diagram Mounting cut-outs [mm] Weight 60 mm Screw 02-021.001 1 0.030 kg with built-in lamp series resistor, 240 VAC/DC to 48 V, 25 mA, for filament lamp 84 mm Screw 02-070.001 1 0.045 kg with built-in lamp series resistor, 110 VAC/DC to 48 V, 25 mA, for filament lamp 84 mm Screw 02-071.001 1 0.045 kg with built-in lamp series resistor, 125 VAC/DC to 48 V, 25 mA, for filament lamp 84 mm Screw 02-072.001 1 0.045 kg with built-in lamp series resistor and diode, 240 VAC/DC to 48 V, 25 mA, for filament lamp 84 mm Screw 02-073.001 1 0.045 kg Product attribute Indicator actuator without serie resistor, for LED or filament lamp Indicator actuator 1 2 Wiring diagram 1 4 Flush design 02 Buzzer, IP 40 10 max. Equipment consisting of (schematic overview) Front bezel 37.6 x 23.5 page 13 Buzzer 75 7 Fixing bezel 84 Dimensions [mm] Product can differ from the current configuration. Each article number listed below includes all the black components shown in the 3D-drawing. Additional Information NJO To obtain a complete unit, please select the red components from the pages shown. * For front dimension 24 x 36 mm * Further information in chapter Technical Data NJO 3NBY Operating voltage Front cap Terminal Part No. Wiring diagram Mounting cut-outs [mm] Weight Pastic black Screw 02-810.001 1 0.060 kg Buzzer 10 ... 55 VAC, 10 ... 75 VDC c U1 = 30 - 55 VAC 35 - 75 VDC U2 = 10 - 35 VAC 10 - 50 VDC d f Continous tone g c f Intermittent tone approx. 3Hz d g Volume control e h e h Wiring diagram 1 5 02 Flush design Pushbutton, IP 40 10 max. 37.6 x 23.5 Equipment consisting of (schematic overview) Front bezel page 13 Lens page 11 75 7 84 Actuator Product can differ from the current configuration. Dimensions [mm] Additional Information * Fixing bezel NJO For front dimension 24 x 36 mm 3NBY NJO Each article number listed below includes all the black components shown in the 3D-drawing. To obtain a complete unit, please select the red components from the pages shown. Contacts Switching action 1C 2C Terminal Wiring diagram Mounting cut-outs [mm] Part No. A Screw 02-611.011 1 0.045 kg C Screw 02-613.011 2 0.045 kg A Screw 02-612.011 3 0.050 kg C Screw 02-614.011 4 0.050 kg B-C Screw 02-615.011 5 0.050 kg Contacts: C = Changeover Switching action: B = Momentary, C = Maintain d e c Wiring diagram 1 6 g f d e h c Wiring diagram 2 Weight Wiring diagram 3 g f e d h c Wiring diagram 4 g f d e h c Wiring diagram 5 g f h Flush design 02 Illuminated pushbutton, IP 40 10 max. Front bezel page 13 Lens page 11 LED page 17 37.6 x 23.5 Equipment consisting of (schematic overview) 75 7 84 Dimensions [mm] [mm] Product can differ from the current configuration. Actuator Additional Information NJO 3NBY Each article number listed below includes all the black components shown in the 3D-drawing. For front dimension 24 x 36 mm * For LED element fitting information see chapter Application guidelines NJO Fixing bezel * To obtain a complete unit, please select the red components from the pages shown. Contacts Switching action Terminal Part No. Wiring diagram Mounting cut-outs [mm] Gewicht Illuminated pushbutton actuator 1C 2C B Screw 02-616.011 1 0.050 kg C Screw 02-618.011 2 0.050 kg B Screw 02-617.011 3 0.055 kg C Screw 02-619.011 4 0.055 kg B-C Screw 02-620.011 5 0.055 kg Contacts: C = Changeover Switching action: B = Momentary, C = Maintain d e 1 c 2 Wiring diagram 1 g f 1 d e h 2 c Wiring diagram 2 d e c g f 1 h 2 Wiring diagram 3 g f 1 e d h 2 c g f 1 h 2 Wiring diagram 4 Wiring diagram 5 7 02 Flush design Mushroom-head pushbutton, IP 40 10 max. Equipment consisting of (schematic overview) 37.6 x 23.5 Mushroom-head page 11 cap Front bezel page 13 75 16 Product can differ from the current configuration. 84 Actuator Dimensions [mm] Additional Information * Use only flush front bezel Fixing sleeve NJO 3NBY Each Part Number listed below includes all the black components shown in the 3D-drawing. NJO For front dimension 24 x 36 mm * To obtain a complete unit, please select the red components from the pages shown. Contacts Switching action Terminal Wiring diagram Mounting cut-outs[mm] Part No. Weight Mushroom-head pushbutton actuator 1C 2C B Screw 02-611.011 1 0.045 kg C Screw 02-613.011 2 0.045 kg B Screw 02-612.011 3 0.050 kg C Screw 02-614.011 4 0.050 kg B-C Screw 02-615.011 5 0.050 kg Contacts: C = Changeover Switching action: B = Momentary, C = Maintain d e c Wiring diagram 1 8 g f d e h c Wiring diagram 2 Wiring diagram 3 g f e d h c Wiring diagram 4 g f d e h c Wiring diagram 5 g f h Flush design 02 Keylock switch 2 positions, IP 40 Equipment consisting of (schematic overview) page 13 Keylock front bezel page 12 37.6 x 23.5 Front bezel 10 max. 26 10 75 Actuator Dimensions [mm] Product can differ from the current configuration. Additional Information Fixing bezel NJO Each article number listed below includes all the black components shown in the 3D-drawing. NJO 3NBY To obtain a complete unit, please select the red components from the pages shown. * For front dimension 24 x 36 mm * Front plastic grey * Keylock number YB1 * After turning the key 90 clockwise, the switch can be operated * In the unlocked switch positions always perform a momentary action * Two keys are supplied with each key lock switch Mounting cut-outs [mm] B A Product attribute Contacts Switching angle Key remove Terminal Part No. Wiring diagram Switching positions (A = Rest, B = Momentary) Gewicht Schlusselschalter-Vorsatz 2 Stellungen A = lockable, actuated 2C B = 90 A Screw 02-690.011 1 0.055 kg A = lockable, non-actuated or actuated 2C B = 90 A Screw 02-692.011 1 0.055 kg A = lockable, non-actuated 2C B = 90 A Screw 02-691.011 1 0.055 kg Contacts: C = Changeover d e c g f h Wiring diagram 1 9 02 Flush design Keylock switch 2 positions, IP 40 Equipment consisting of (schematic overview) 10 max. 37.6 x 23.5 Front bezel 26 10 page 13 Keylock front bezel 75 Actuator Product can differ from the current configuration. Dimensions [mm] Additional Information Fixing bezel NJO * For front dimension 24 x 36 mm * Front plastic grey * Keylock number YB1 * After turning the key 90 clockwise, the switch can be operated * In the unlocked switch positions always perform a momentary action * Two keys are supplied with each key lock switch NJO 3NBY Each article number listed below includes all the black components shown in the 3D-drawing. To obtain a complete unit, please select the red components from the pages shown. Mounting cut-outs [mm] B A Wiring diagram Switching positions (A = Rest, B = Momentary) Gewicht A = lockable, non-actuated, B = lockable, key not removable 2C B = 90 A Screw 02-695.011 1 0.055 kg A = lockable, non-actuated or actuated; can be used with protective cover Part No. 22-925 2C B = 90 A Screw 02-198.011 1 0.055 kg Product attribute Contacts Switching angle Key remove Terminal Part No. Schlusselschalter-Vorsatz 2 Stellungen Contacts: C = Changeover d e c Wiring diagram 1 10 g f h Accessories 02 Front Lens Additional Information * Material plastic Product attribute Dimension Lens Part No. Weight Lens illuminative, not suitable for film insert, ripped 17.5 x 25.4 mm illuminative, use holder for film insert 17.5 x 25.4 mm non-illuminative 17.5 x 25.4 mm smoked translucent 02-901.1 0.004 kg red translucent 02-901.2 0.004 kg orange translucent 02-901.3 0.004 kg yellow translucent 02-901.4 0.004 kg green translucent 02-901.5 0.004 kg blue translucent 02-901.6 0.004 kg colourless transparent 02-901.7 0.004 kg white translucent 02-901.9 0.004 kg red translucent 02-902.2 0.004 kg green translucent 02-902.5 0.004 kg colourless transparent 02-902.7 0.004 kg black opaque 02-901.0 0.004 kg grey opaque 02-901.8 0.004 kg Keylock front bezel Additional Information * Keylock number YB1 * Further lock numbers see Technical data Product attribute Dimension Material Colour Part No. Weight 17.5 x 25.5 mm Plastic grey 02-980.1 0.002 kg 17.5 x 25.5 mm Plastic grey 02-982.1 0.002 kg Keylock front bezel for keylock switch Part No. 02-695 11 02 Accessories Holder Additional Information * For lens with film insert Material Colour Optics Part No. Weight red translucent 02-908.2 0.001 kg orange translucent 02-908.3 0.001 kg yellow translucent 02-908.4 0.001 kg green translucent 02-908.5 0.001 kg blue translucent 02-908.6 0.001 kg colourless transparent 02-908.7 0.001 kg white translucent 02-908.9 0.001 kg Holder Plastic Diffusor plate Additional Information * For lens with film insert Part No. Weight Diffusor plate 02-909 0.001 kg Front bezel flush Additional Information * Lens only removable with lens remover Part No. 02-905 Front bezel Part No. Weight 02-965.0 0.001 kg Front bezel flush, Front dimension 24 x 36 mm Pastic black 12 Accessories 02 Front bezel raised Additional Information * Lens only removable with lens remover Part No. 98-969 Front bezel Part No. Weight 02-967.0 0.001 kg Front bezel raised, Front dimension 24 x 36 mm Pastic black Protective cover, IP 65 Additional Information Use only flush front bezel * Hinged, with means for sealing * Front panel thickness reduces by 2 mm 36.5 36 30 * 18 13.7 Please note that bigger minimum distances are necessary 29.7 * 2 10.5 Dimensions [mm] Product attribute Material Optics Dimension Part No. Weight Plastic transparent 36 x 29.7 mm 22-925 0.004 kg Protective cover for button with mounting cut-out 21.2 x 29.2 mm 13 02 Accessories Spare key Additional Information * Keylock number YB1 Part No. Weight Spare key 02-989.001 0.001 kg Front protective cap, IP 65 Additional Information * Use only flush front bezel * Three-part NJO 42 NJO 30 3NBY 9.5 Dimensions [mm] Material Colour Mounting cut-outs [mm] Optics Temperature Part No. Weight transparent -20 ... +60 02-924 0.005 kg -25 ... +85 02-935 0.005 kg Front protective cap PVC 14 colourless Accessories 02 Blind plug NJO NJO 3 NBY Mounting cut-outs [mm] Dimension Material Colour Part No. Weight Blind plug 24 x 36 mm Plastic black 02-949.0 0.004 kg grey 02-949.8 0.004 kg 15 02 Accessories Backside Terminal cover Additional Information * For all connection methods * Not suitable for indicators with built-in series resistor with lamp Part No. Weight Terminal cover 02-929 16 0.005 kg Accessories 02 Illumination Single-LED, T6.8 Additional Information For LED element fitting information see Application guidelines * Due to high surface temperatures, the series resistor must not be soldered directly to the terminals of the equipment (use a terminal plate) * When using AC/DC types with AC operation, slight flickering can occure * Luminous intensity data of the LEDs on direct voltage * Electrical and optical data are measured at 25 C * The specified versions are built with a protection diode (halve wave rectifier) in series and the LED * Luminosity and wave length variations caused by LED manufacturing processes may cause slight differences regarding the illumination * For supply voltages above 48 V, it is necessary to use a voltage reduction element (external series resistor or transformer) LED colour Operating voltage 45 max. + O 7.1 max. * Dimensions [mm] Operation current Lumi. intensity Dom. wavelength Part No. Weight 6 VDC 17 mA 15 % 400 mcd 630 nm 10-2K06.3152 0.002 kg 12 VAC/DC 9/17 mA 15 % 400 mcd 630 nm 10-2K09.1072 0.002 kg 24 VAC/DC 9/17 mA 15 % 400 mcd 630 nm 10-2K12.1072 0.002 kg 28 VAC/DC 9/17 mA 15 % 400 mcd 630 nm 10-2K13.1072 0.002 kg 48 VAC/DC 4/8 mA 15 % 200 mcd 630 nm 10-2K19.1052 0.002 kg 6 VDC 17 mA 15 % 340 mcd 340 nm 10-2K06.3154 0.002 kg 12 VAC/DC 9/17 mA 15 % 340 mcd 340 nm 10-2K09.1074 0.002 kg 24 VAC/DC 9/17 mA 15 % 340 mcd 340 nm 10-2K12.1074 0.002 kg 28 VAC/DC 9/17 mA 15 % 340 mcd 340 nm 10-2K13.1074 0.002 kg 48 VAC/DC 4/8 mA 15 % 180 mcd 340 nm 10-2K19.1054 0.002 kg 6 VDC 7 mA 15 % 1050 mcd 525 nm 10-2K06.3155 0.002 kg 12 VAC/DC 4/7 mA 15 % 1050 mcd 525 nm 10-2K09.1075 0.002 kg 24 VAC/DC 4/7 mA 15 % 1050 mcd 525 nm 10-2K12.1075 0.002 kg 28 VAC/DC 4/7 mA 15 % 1050 mcd 525 nm 10-2K13.1075 0.002 kg 48 VAC/DC 2/4 mA 15 % 600 mcd 525 nm 10-2K19.1055 0.002 kg 6 VDC 17 mA 15 % 780 mcd 470 nm 10-2K06.3156 0.002 kg 12 VAC/DC 9/17 mA 15 % 780 mcd 470 nm 10-2K09.1076 0.002 kg 24 VAC/DC 9/17 mA 15 % 780 mcd 470 nm 10-2K12.1076 0.002 kg 28 VAC/DC 9/17 mA 15 % 780 mcd 470 nm 10-2K13.1076 0.002 kg 48 VAC/DC 4/8 mA 15 % 400 mcd 470 nm 10-2K19.1056 0.002 kg Single-LED red yellow green blue 17 02 Accessories LED colour Operating voltage Operation current Lumi. intensity Dom. wavelength Part No. Weight white 6 VDC 6 mA 15 % 900 mcd x0.31/y0.32 nm 10-2K06.3159 0.002 kg 12 VAC/DC 3/6 mA 15 % 900 mcd x0.31/y0.32 nm 10-2K09.1079 0.002 kg 24 VAC/DC 3/6 mA 15 % 900 mcd x0.31/y0.32 nm 10-2K12.1079 0.002 kg 28 VAC/DC 2.5/5 mA 15 % 750 mcd x0.31/y0.32 nm 10-2K13.1079 0.002 kg 48 VAC/DC 2/4 mA 15 % 600 mcd x0.31/y0.32 nm 10-2K19.1059 0.002 kg Part No. Weight Filament lamp, T6.8 Operating voltage Operation current Filament lamp 12 VAC/DC 50 mA 10 % 10-1209.1279 0.001 kg 12 VAC/DC 100 mA 10 % 10-1209.1329 0.001 kg 24 VAC/DC 25 mA 10 % 10-1212.1199 0.001 kg 24 VAC/DC 50 mA 10 % 10-1212.1279 0.001 kg 28 VAC/DC 40 mA 10 % 10-1213.1249 0.001 kg 30 VAC/DC 40 mA 10 % 10-1214.1249 0.001 kg 36 VAC/DC 35 mA 10 % 10-1216.1229 0.001 kg Resistance Part No. Weight 110 VAC 2.7 kOhm 02-904.0 0.003 kg 125 VAC 3.3 kOhm 02-904.1 0.003 kg 145 VAC 4.7 kOhm 02-904.3 0.003 kg 240 VAC 10 kOhm 02-904.7 0.003 kg Series resistor Additional Information * For filament lamp 48 VAC, 25 mA * For lamp voltage reduction * Keep to the country specific safety instructions * Due to high surface temperatures, the series resistor must not be soldered directly to the terminals of the equipment (use a terminal plate) Operating voltage Series resistor 18 Accessories 02 Terminal plate empty Additional Information * For fitting with series resistors Product attribute Dimension Part No. Weight Terminal plate empty 5 spaces 62.5 x 60 x 15 mm 02-912.1 0.025 kg 10 spaces 125 x 60 x 15 mm 02-912.2 0.045 kg 15 spaces 187.6 x 60 x 15 mm 02-912.3 0.090 kg 20 spaces 250 x 60 x 15 mm 02-912.4 0.095 kg 19 02 Accessories Mounting Lens remover Product attribute Part No. Weight 02-905 0.011 kg 98-968 0.004 kg Lens remover for flush front bezel Lens remover for raised front bezel Lamp remover Additional Information p Vorsicht: A switching process might be released when replacing the lamp Product attribute Part No. Weight 03-996 0.027 kg 61-9740.0 0.003 kg Lamp remover for LED Lamp remover for filament lamp 20 Technical data 02 Actuator with snap-action switching element Switching system 1 or 2 self-cleaning, snap-action switching elements. 1 or 2 double-throw contacts. Material Material of contact Standard version: Silver (U > 20 V) Special versions: (on request) Gold/Silver 700 Au/300 Ag (U < 50 V) Silver/Palladium 700 Ag/300 Pd (U > 20 V) for atmospheres containing sulphur Conventional free air thermal current 10 A The maximum current in continuous operation and at ambient temperature not exceeding the quoted maximum values. Switch rating 400 VAC, 10 A, cos 0.95, as per IEC 60947-5-1 250 VAC, 10 A, as per UL Electric strength 2500 VAC, 50 Hz, 1 min. between all terminals and earth, as per IEC 60947-5-1 Environmental conditions Switch housing Thermosetting material, heat-resistant Storage temperature -30 C ... +85 C Indicator housing with reduced length Polyamide Service temperature -25 C ... +55 C For indicators and illuminated pushbuttons mounted as a block, make sure the heat can escape freely. Mechanical characteristics Terminals Screw terminal (with self-lifting clip): max. wire cross-section, 2 x 2.5 mm max. wire cross-section of stranded cable, 2 x 1.5 mm Protection degree Front side IP 40, IP 65 with spray cover, as per IEC 60529 Shock resistance 15 g for 11 ms, as per IEC 60068-2-27 Tightening torque For fixing sleeve max. 20 Ncm For screw terminal max. 80 Ncm Vibration resistance 10 g at 10 ... 2000 Hz, amplitude 1.0 mm, as per IEC 60068-2-6 Actuating force 6 N ... 12 N Approvals Actuating travel 5 mm Mechanical lifetime Momentary action 2 million operations Maintained action 1 million operations Approbations CB (IEC 60947-5-1) CSA Germanischer Lloyd UL Declaration of conformity CE Electrical characteristics Standards The switches comply with the "Standards for low-voltage switching devices" IEC 60947-5-1 Rated insulation voltage 400 VAC/440 VDC, as per IEC 60947-5-1 21 02 Technical data Buzzer Buzzer system System Electronic non-contacting buzzer with IC oscillator Material Buzzer case Thermosetting material Front cap Polycarbonate (PC) Operation Voltage/Current typical 10 ... 55 VAC 10 ... 75 VDC 25 mA 15 mA Environmental conditions Storage temperature -40 C ... +85 C Operating temperature -25 C ... +55 C Protection degree Front side IP 40, as per IEC 60529 Front bezel Polymethylacrylate Approvals Mechanical characteristics Terminals Screw terminal Tightening torque For fixing sleeve max. 20 Ncm For screw terminal max. 80 Ncm Electrical characteristics Frequency (tone) Approx. 2.8 kHz Sound pressure 85 dB (A) 8 dB at a distance of 0.1 m Volume variable with a M potentiometer or corresponding fixed resistor EAO reserves the right to alter specifications without further notice. 22 Approbations CB (IEC 60947-5-1) Declaration of conformity CE Marking 02 General notes 1. Engraving In addition to the most commonly used world languages, in DIN1451-3 close spacing, other typefaces are available as Scandinavian, Slavic, Greek, Russian and Polish. Red, blue and black lenses are filled with white colour. Other colour lenses are filled in black. Standard height of letters is 3 mm. If the height is not specified, we will supply 3 mm engraved letters. 3. Film inserts Instead of using engraving the lenses can be fitted with transparent film inserts, as an alternative. For this purpose, though, it is advisible to use lenses without ripped pattern. In the case of use of a smoke-black lens the fitted film becomes readable only if the lamp is on. The film (F) is inserted in the cap. To ensure even illumination a diffusor (D) is recommended, which is inserted beneath the film. If, on the other hand, the diffusor is inserted 2. Hot stamping above the film, the lettering only becomes legible when the lamp For larger series it is worth considering markings by means of hot is alight. To hold the film and diffusor in position, the use of a stamping. We will pleased to advise you. For letters and figures, holder (N) is advised. The film thickness is 0.2 mm. typefaces with 2.5 mm, 3 mm and 4 mm are available. All dimensions in mm Number of small letters per line (target value) Image Film insert max. size Height of letters h Number of lines Number of capital letters per line (target value) 14.3 x 22.4 3 4 11 13 B1 7-8 8-9 B2 4 2 7 9 B1 4 5 5-6 B2 2 5-6 6-7 B1 3 3-4 4 B2 1 5 6 B1 2 3 4 B2 1 3 4 B1 2 2 B2 6 8 F D B1 B2 ABC abc ABC abc h 5 N 23 02 Application guidelines Suppressor circuits When switching inductive loads such as relays, DC motors, and DC solenoids, it is always important to absorb surges (e. g. with a diode) to protect the contacts. When these inductive loads are switched off, a counter emf can severely damage switch contacts and greatly shorten lifetime. Fig. 1 shows an inductive load with a free-wheeling diode connected in parallel. This free-wheeling diode provides a path for the inductor current to flow when the current is interrupted by the switch. Without this free-wheeling diode, the voltage across the coil will be limited only by dielectric breakdown voltages of the circuit or parasitic elements of the coil. This voltage can be kilovolts in amplitude even when nominal circuit voltages are low (e. g. 12 VDC) see Fig. 2. The free-wheeling diode should be chosen so that the reverse breakdown voltage is greater than the voltage driving the inductive load. The DC blocking voltage (VR) of the free-wheeling diode can be found in the datasheet of a diode. The forward current should be equal or greater than the maximum current flowing through the load. To get an efficient protection, the free-wheeling diode must be connected as close as possible to the inductive load! Counter EMF over load without free-wheeling diode Fig. 2 Switching with inductive load Fig. 1 Switch ON OFF 0 VDC + _ Free-wheeling diode Inductive load Several hundred to several thousend volts LED polarity When fitting the LED element the polarity has to correspond with the respective terminal, (+) goes to +. 1 24 (+) 2 + di __ e = L dt 02 Index Index from Part No. Part No. Page 02-021.001................. 4 02-070.001................. 4 02-071.001................. 4 02-072.001................. 4 02-073.001................. 4 02-198.011............... 10 02-611.011................. 6 02-611.011................. 8 02-612.011................. 6 02-612.011................. 8 02-613.011................. 6 02-613.011................. 8 02-614.011................. 6 02-614.011................. 8 02-615.011................. 6 02-615.011................. 8 02-616.011................. 7 02-617.011................. 7 02-618.011................. 7 02-619.011................. 7 02-620.011................. 7 02-690.011................. 9 02-691.011................. 9 02-692.011................. 9 02-695.011............... 10 02-810.001................. 5 02-901.0................... 11 02-901.1................... 11 02-901.2................... 11 02-901.3................... 11 02-901.4................... 11 02-901.5................... 11 02-901.6................... 11 02-901.7................... 11 02-901.8................... 11 02-901.9................... 11 02-902.2................... 11 02-902.5................... 11 02-902.7................... 11 02-904.0................... 18 02-904.1................... 18 02-904.3................... 18 02-904.7................... 18 02-905...................... 20 02-908.2................... 12 02-908.3................... 12 02-908.4................... 12 02-908.5................... 12 02-908.6................... 12 02-908.7................... 12 02-908.9................... 12 02-909...................... 12 02-912.1................... 19 02-912.2................... 19 02-912.3................... 19 02-912.4................... 19 02-924...................... 14 02-929...................... 16 02-935...................... 14 02-949.0................... 15 02-949.8................... 15 02-965.0................... 13 02-967.0................... 13 02-980.1................... 12 02-989.001............... 14 03-996...................... 20 10-1209.1279........... 18 10-1209.1329........... 18 10-1212.1199........... 18 10-1212.1279........... 18 10-1213.1249........... 18 10-1214.1249........... 18 10-1216.1229........... 18 10-2K06.3152........... 17 10-2K06.3154........... 17 10-2K06.3155........... 17 10-2K06.3156........... 17 Part No. Page 10-2K06.3159........... 18 10-2K09.1072........... 17 10-2K09.1074........... 17 10-2K09.1075........... 17 10-2K09.1076........... 17 10-2K09.1079........... 18 10-2K12.1072........... 17 10-2K12.1074........... 17 10-2K12.1075........... 17 10-2K12.1076........... 17 10-2K12.1079........... 18 10-2K13.1072........... 17 10-2K13.1074........... 17 10-2K13.1075........... 17 10-2K13.1076........... 17 10-2K13.1079........... 18 10-2K19.1052........... 17 10-2K19.1054........... 17 10-2K19.1055........... 17 10-2K19.1056........... 17 10-2K19.1059........... 18 22-925...................... 13 61-9740.0................. 20 98-968...................... 20 25 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: EAO: 02-021.001 02-901.1 02-902.2 02-904.6 02-901.4 02-902.5 02-904.2 02-072.001