SAC-5P- 2,0-186/FS SCO Order No.: 1518368
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1518368
PHOENIX CONTACT Inc., USA Page 2 / 5
http://www.phoenixcon.com Nov 19, 2010
Insulation resistance ≥ 100 MΩ
Length of cable 2 m
Stripping length of the free conductor end 50 mm
Ambient temperature (operation) -25 °C ... 90 °C (Male connector / female connector)
General characteristics
Coding A - standard
Surge voltage category II
Pollution degree 3
Degree of protection IP65/IP68/IP69K
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material TPU GF
Material of grip body TPU, hardly inflammable, self-extinguishing
Material, knurls Zinc die-cast, (nickel-plated)
Sealing material NBR
Status display No
Conductor data
Cable type PUR/PVC black
Cable type (abbreviation) 186
Cable abbreviation LiY11Y
Conductor cross section 0.75 mm²
AWG signal line 18
Conductor structure signal line 42x 0.15 mm
Core diameter including insulation 1.7 mm ±0.05 mm
Thickness, insulation ≥ 0.23 mm (Core insulation)
≥ 0.76 mm (Outer cable sheath)
External cable diameter 6.30 mm
Wire colors Brown, white, blue, black, gray
External sheath, color Black-gray RAL 7021
Insulation resistance ≥ 1 MΩ*km
Conductor resistance max. 26 Ω/km
Nominal voltage, conductor ≤ 300 V
Test voltage, conductor ≥ 3000 V
Overall twist 5 wires around filler to the core