Page 7 of 8 WFxxK_V02 Jan.2010
00-S-R45
TEST AND REQUIREMENTS(JIS C 5201-1 : 1998)
REQUIREMENT
TEST PROCEDURE Resistor
DC resistance
Clause 4.5 DC resistance values measured
<10Ω@0.1V, <100Ω@0.3V, <1KΩ@1.0V,
<10KΩ@3V, <100KΩ@10V,<1MΩ@25V,
<10MΩ@30V
Within the specified tolerance
Temperature
Coefficient of
Resistance(T.C.R)
Clause 4.8
Natural resistance change per change in degree
centigrade.
( )
6
121
12 10×
−
ttR RR
(ppm/°C)
R
1
: Resistance at reference temperature
R
2
: Resistance at test temperature
t
1
: 20°C+5°C-1°C
Refer to “QUICK REFERENCE DATA”
Short time overload
(S.T.O.L)
Clause 4.13
Permanent resistance change after a 5second
application of a voltage 2.5 times RCWV or the
maximum overload voltage specified in the above
list, whichever is less.
∆R/R max. ±(0.5%+0.05Ω)
Resistance to soldering
heat(R.S.H)
Clause 4.18
Un-mounted chips completely immersed for
10±1second in a SAC solder bath at 260℃±5ºC no visible damage
∆ R/R max. ±(0.5%+0.05Ω)
Solderability
Clause 4.17
Un-mounted chips completely immersed for 2±0.5
second in a SAC solder bath at 235℃±5℃ good tinning (>95% covered)
no visible damage
Temperature cycling
Clause 4.19
30 minutes at -55°C±3°C, 2~3 minutes at
20°C+5°C-1°C, 30 minutes at +125 °C±3°C,
2~3 minutes at 20°C+5°C-1°C, total 5
continuous cycles
no visible damage
∆R/R max. ±(0.5%+0.05Ω)
Load life (endurance)
Clause 4.25 70±2ºC, 1000 hours, loaded with RCWV or
Vmax,1.5 hours on and 0.5 hours off ∆R/R max. ±(1.0%+0.05Ω)
Load life in Humidity
Clause 4.24 1000 hours, at rated continuous working voltage in
humidity chamber controller at 40°C±2°C and
90~95% relative humidity, 1.5hours on and 0.5
hours off
∆R/R max. ±(1.0%+0.05Ω)
Bending strength
Clause 4.33 Resistors mounted on a 90mm glass epoxy resin
PCB(FR4); bending : 3 mm, once for 10 seconds. ∆R/R max. ±(0.5%+0.05Ω)
Adhision
Clause 4.32 Pressurizing force: 5N, Test time: 10±1sec. No remarkable damage or removal of the
terminations.
Insulation Resistance
Clause 4.6 Apply the maximum overload voltage (DC) for
1minute R≧10GΩ
Dielectric Withstand
Voltage
Clause 4.7
Apply the maximum overload voltage (AC) for 1
minute No breakdown or flashover