SCD Number SPECIFICATION CONTROL DRAWING _ 44A0811 TITLE WIRE, RADIATION-CROSSLINKED, POLYALKENE-INSULATED, Revision MEDIUMWEIGHT, 600 VOLT 28-Mar-11 Pi This specification sheet forms a part of the latest issue of Raychem Specification 44. CONDUCTOR -TIN-COATED COPPER PRIMARY INSULATION -RADIATION-CROSSLINKED, EXTRUDED POLYALKENE a as eee snannnaance TABLE!. CONSTRUCTION DETAILS DIAMETER OF STRANDED CONDUCTOR (in.) MINIMUM _]|_ MAXIMUM WIRE SIZE (AWG) CONDUCTOR STRANDING (number x AWG PARTNUMBER i 20C 4440811 -000-* 000 1665 x 30 515 540 TABLE ||. PERFORMANCE DETAILS BEND TESTING MANDREL DIAMETER PART NUMBER nch AV t3% IMMERSION, LIFE CYCLE AND ACCELERATEDAGING COLD BEND WRAP 4440811-000-* ohms/1000ft. JACKET - RADIATION-CROSSLINKED, MODIFIEDPVDF, Thickness: AWG 26 - 4 .005 + .001 in. AWG 2 - 000 .010 + .002 in. FINISHED WIRE MAXIMUM ESISTANCEA MAXIMUM WEIGHT (Ibs/1000 ft.) DIAMETER (in) 634 + 020 WEIGHT Ib) (+ 3% IMMERSION, LIFE CYCLE AND ACCELERATEDAGING 20.0 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE Connectivity also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL, Page 1 of 2 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. TE Connectivity Wire & Cabie =, 50 Oakside Avenue a Redwood City, California 94063-3800 TE Connectivity 7300.227-8816 Fax: 1-650-361-6297 9 FE speciFicATION CONTROL DRAWING | Page 2 of 2 TE Connectivity Revision SCD Number Pq 44A0811 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductortemperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING: 300 + 2C for 6 hours Identification legibility, 225 + 2C for 6 hours BLOCKING: 150+ 2C for 24 hours COLOR: White preferred FLAMMABILITY: 30 seconds (maximum); 3 inches (maximum); no flaming of facial tissue HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft (minimum) IDENTIFICATION, STRIPING, ORBAND DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown INSULATION ELONGATION AND TENSILE STRENGTH: Primary Insulation, Elongation, 150% (minimum) Tensile Strength, 2500 Ibffin? (minimum), AWG 26-12 2000 Ibf/in? (minimum), AWG 10 & larger INSULATIONFLAWS: Primary Insulation, SparkTest, 3.0 kV (rms) at 60 Hz 4.2 kV (rms) at 3 kHz Impulse DielectricTest, 6.0 kV (peak) Finished Wire, SparkTest, 5.7 kV (rms) at 3 kHz Impulse DielectricTest, 8.0 kV (peak) INSULATION RESISTANCE: 5000 megohms for 1000 ft (minimum) LIFECYCLE: 200 + 2C for 168 hours LOW TEMPERATURE COLD BEND: -65 + 2C for 4 hours SHRINKAGE: 300 + 2C, 0.125 in. (maximum) in 12 inches, AWG 26-12 0.250 in. (maximum) in 12 inches, AWG 10 & larger SMOKE: 200 + 2C, no visible smoke. SOLDERABILITY: 95% minimum coverage. Per MIL-STD-202, Method 208, except without steam aging, Type RMA Flux (for 10 AWG & smaller only) SURFACE RESISTANCE: 500 megohms-in. (minimum), both readings THERMAL SHOCK RESISTANCE: 150 + 2C, 0.060 in. (maximum) VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes WICKING: 2.25 in. (maximum) PART NUMBER: The "*" in the part numbers on page 1 shall be replaced by color code designators. 1/Example: AWG 18, white: 44A0811-18-9 AWG 14, white with a black stripe: 444081 1-14-90 1/ See Footer section on page 1.