3006 - Trimpot® Trimming Potentiometer
Features
n Axial leaded
n Weldable nickel terminals
n Very low internal resistance
n Operating currents to 9.0 amps
n RoHS compliant*
n Agency recognition:
Applications
Any application that requires protection at low
resistances:
n Rechargeable battery pack protection
n Cellular phones
n Laptop computers
MF-LR Series - PTC Resettable Fuses
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice. Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
*RoHS COMPLIANT
LEAD FREE
*RoHS COMPLIANT
VERSIONS
AVAILABLE
LEAD FREE
VERSIONS ARE
RoHS COMPLIANT*
Environmental Characteristics
Operating/Storage Temperature ........................... -40 °C to +85 °C
Passive Aging ....................................................... +70 °C, 1000 hours ............................................... ±10 % typical resistance change
Humidity Aging...................................................... +85 °C, 85% R.H. 7 days ...................................... ±10 % typical resistance change
Vibration ............................................................... MIL-STD-883C, ..................................................... No change
Condition A
Test Procedures And Requirements For Model MF-LR Series
Test Test Conditions Accept/Reject Criteria
Visual/Mech. ......................................................... Verify dimensions and materials ........................... Per MF physical description
Resistance ............................................................ In still air @ 23 °C ................................................. Rmin R R1max
Time to Trip ........................................................... At specied current, Vmax, 23 °C ......................... T max. time to trip (seconds)
Hold Current ......................................................... 30 min. at Ihold ..................................................... No trip
Trip Cycle Life ....................................................... Vmax, Imax, 100 cycles ........................................ No arcing or burning
Trip Endurance ..................................................... Vmax, 48 hours ..................................................... No arcing or burning
cUL File Number ................................................... E174545
TÜV File Number .................................................. R2057213
Electrical Characteristics
Thermal Derating Chart - Ihold (Amps)
Model Ambient Operating Temperature
-40 ºC -20 ºC 0 ºC 23 ºC 40 ºC 50 ºC 60 ºC 70 ºC 85 ºC
MF-LR190 2.8 2.5 2.3 1.9 1.6 1.5 1.4 1.2 1.0
MF-LR260 3.8 3.4 3.1 2.6 2.2 2.0 1.9 1.7 1.4
MF-LR380 5.5 4.9 4.4 3.8 3.3 3.0 2.8 2.5 2.1
MF-LR450 6.5 5.8 5.3 4.5 3.9 3.6 3.3 2.9 2.5
MF-LR550 8.0 7.1 6.2 5.5 4.7 4.3 4.0 3.6 3.0
MF-LR550/20 8.0 7.1 6.2 5.5 4.7 4.3 4.0 3.6 3.0
MF-LR600 8.7 7.8 7.1 6.0 5.2 4.7 4.4 3.9 3.3
MF-LR730 10.5 9.5 8.6 7.3 7.4 6.8 6.2 5.5 4.5
MF-LR730/20 10.5 9.5 8.6 7.3 7.4 6.8 6.2 5.5 4.5
MF-LR900/20 12.7 11.4 10.0 9.0 7.5 6.8 6.2 5.5 4.5
Model V max.
Volts
I max.
Amps
Ihold Itrip Initial
Resistance
1 Hour (R1)
Post-Trip
Resistance
Max. Time
to Trip
Tripped Power
Dissipation
Amperes
at 23 °C
Ohms
at 23 °C
Ohms
at 23 °C
Amperes
at 23 °C
Seconds
at 23 °C
Watts
at 23 °C
Hold Trip Min. Max. Max. Typ.
MF-LR190 15 100 1.90 3.90 0.039 0.072 0.102 9.5 5.0 1.2
MF-LR260 15 100 2.60 5.80 0.020 0.042 0.083 13.0 5.0 1.3
MF-LR380 15 100 3.80 8.30 0.013 0.026 0.037 19.0 5.0 2.5
MF-LR450 16 100 4.50 8.90 0.011 0.020 0.028 22.5 5.0 1.4
MF-LR550 10 100 5.50 10.50 0.009 0.019 0.022 27.5 5.0 1.4
MF-LR550/20 20 100 5.50 10.50 0.009 0.019 0.022 27.5 5.0 1.4
MF-LR600 10 100 6.00 11.70 0.007 0.014 0.019 30.0 5.0 2.8
MF-LR730 10 100 7.30 14.10 0.006 0.012 0.015 30.0 5.0 3.0
MF-LR730/20 20 100 7.30 14.10 0.006 0.012 0.015 30.0 5.0 3.0
MF-LR900/20 20 100 9.00 16.70 0.006 0.010 0.014 45.0 5.0 3.0
Itrip is approximately two times Ihold.
3312 - 2 mm SMD Trimming Potentiometer
Typical Time to Trip at 23 ˚C
How to Order
MF - LR 730/20 - 0
Multifuse® Product
Designator
Series
LR = Axial Leaded “Strap”
Component
Hold Current, Ihold/Vmax*
190-900 (1.90 Amps - 9.00 Amps)
Packaging Options
-__ = Bulk Packaging Designator
for Models MF-LR190 through
MF-LR730
-0 = Bulk Packaging Designator
for Models MF-LR550/20,
MF-LR730/20 and
MF-LR900/20
*Vmax entry applies only to Models MF-LR550/20,
MF-LR730/20 & MF-LR900/20.
**Packaged per EIA 486-B
Product Dimensions
Model A B C D F
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.
MF-LR190 19.9
(0.783)
22.1
(0.870)
4.9
(0.193)
5.2
(0.205)
0.6
(0.024)
1.0
(0.039)
5.5
(0.217)
7.5
(0.295)
3.9
(0.154)
4.1
(0.161)
MF-LR260 20.9
(0.823)
23.1
(0.909)
4.9
(0.193)
5.2
(0.205)
0.6
(0.024)
1.0
(0.039)
4.1
(0.161)
5.5
(0.217)
3.9
(0.154)
4.1
(0.161)
MF-LR380 24.0
(0.945)
26.0
(1.024)
6.9
(0.272)
7.5
(0.295)
0.6
(0.024)
1.0
(0.039)
4.1
(0.161)
5.5
(0.217)
4.9
(0.193)
5.1
(0.201)
MF-LR450 24.0
(0.945)
26.0
(1.024)
9.9
(0.390)
10.5
(0.414)
0.6
(0.024)
1.0
(0.039)
5.3
(0.209)
6.7
(0.264)
5.9
(0.232)
6.1
(0.240)
MF-LR550 35.0
(1.378)
37.0
(1.457)
6.9
(0.272)
7.5
(0.295)
0.6
(0.024)
1.0
(0.039)
5.3
(0.209)
6.7
(0.264)
4.9
(0.193)
5.1
(0.201)
MF-LR550/20 35.0
(1.378)
37.0
(1.457)
6.9
(0.272)
7.5
(0.295)
0.6
(0.024)
1.0
(0.039)
5.3
(0.209)
6.7
(0.264)
4.9
(0.193)
5.1
(0.201)
MF-LR600 24.0
(0.945)
26.0
(1.024)
13.9
(0.547)
15.9
(0.626)
0.6
(0.024)
1.0
(0.039)
4.1
(0.161)
5.5
(0.217)
5.9
(0.232)
6.1
(0.240)
MF-LR730 30.0
(1.18)
29.1
(1.146)
13.9
(0.547)
15.0
(0.590)
0.6
(0.024)
1.0
(0.039)
4.1
(0.161)
5.5
(0.217)
5.9
(0.232)
6.1
(0.240)
MF-LR730/20 27.1
(1.067)
29.1
(1.146)
13.9
(0.547)
14.5
(0.571)
0.6
(0.024)
1.0
(0.039)
4.1
(0.161)
5.5
(0.217)
5.9
(0.232)
6.1
(0.240)
MF-LR900/20 45.4
(1.787)
47.6
(1.874)
7.9
(0.311)
8.5
(0.335)
0.6
(0.024)
1.3
(0.051)
4.6
(0.181)
9.2
(0.362)
5.9
(0.232)
6.1
(0.240)
Packaging: Bulk - 500 pcs. per bag. Tape and Reel - Consult factory.
DIMENSIONS: MM
(INCHES) Typical Part Marking
Represents total content. Layout may vary.
Specifications are subject to change without notice.
Users should verify actual device
performance in their specific applications.
The products described herein and this document are subject
to specific legal disclaimers as set forth on the last page of
this document, and at www.bourns.com/docs/legal/
disclaimer.pdf.
MF-LR Series - PTC Resettable Fuses
F
B
D D
C
A
F
B
D D
A
Standard Style "S" Style
C
SLIT NOMINAL
0.5
(.020)
4.0
(.157)
X
MANUFACTURER'S
TRADEMARK PART
IDENTIFICATION
LOT NO.
(T = TAIWAN
S = CHINA)
LR190
0144T
DATE CODE
(FIRST DIGIT =
LAST DIGIT OF YEAR;
NEXT THREE DIGITS =
DAY OF YEAR)
MF-LR SERIES, REV. W, 04/17
.01
110 100
1
10
100
Fault Current (Amps)
Time to Trip (Seconds)
MF-LR190
MF-LR260
MF-LR380
MF-LR450
MF-LR550
MF-LR550/20
MF-LR600
MF-LR730 & MF-LR730/20
MF-LR900/20
MF-S, MF-LS, MF-LR* and MF-VS Series Tape and Reel Specifications
DIMENSIONS: MM
(INCHES)
Taped Component Dimensions
PASTEBOARD
HOLD
PASTEBOARD
HOLD
4.0 ± 0.2
(.157 ± .008)
2.0
(.079)
RADIUS
DIA.
13.0
(.512)
DIA.
1.0 + 0.1/ -0
(.039 + .004/-0)
5.56 ± 0.10
(.219 ± .004)
4.0 ± 0.1
(.157 ± .004)
12.0 ± 0.1
(.472 ± .004)
48.0 ± 0.3
(1.90 ± .012)
0.2
(.008)MAX.
330
(13.0)
8.0 ± 0.2
(.315 ± .008)
Reel Dimensions
*Bulk packaging is standard for Model MF-LR Series; consult factory for tape and reel option.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
Legal Disclaimer Notice
This legal disclaimer applies to purchasers and users of Bourns® products manufactured by or on behalf of Bourns, Inc. and
its aliates (collectively, “Bourns”).
Unless otherwise expressly indicated in writing, Bourns® products and data sheets relating thereto are subject to change
without notice. Users should check for and obtain the latest relevant information and verify that such information is current
and complete before placing orders for Bourns® products.
The characteristics and parameters of a Bourns® product set forth in its data sheet are based on laboratory conditions, and
statements regarding the suitability of products for certain types of applications are based on Bourns’ knowledge of typical
requirements in generic applications. The characteristics and parameters of a Bourns® product in a user application may vary
from the data sheet characteristics and parameters due to (i) the combination of the Bourns® product with other components
in the user’s application, or (ii) the environment of the user application itself. The characteristics and parameters of a Bourns®
product also can and do vary in dierent applications and actual performance may vary over time. Users should always verify
the actual performance of the Bourns® product in their specic devices and applications, and make their own independent
judgments regarding the amount of additional test margin to design into their device or application to compensate for
dierences between laboratory and real world conditions.
Unless Bourns has explicitly designated an individual Bourns® product as meeting the requirements of a particular industry
standard (e.g., ISO/TS 16949) or a particular qualication (e.g., UL listed or recognized), Bourns is not responsible for any
failure of an individual Bourns® product to meet the requirements of such industry standard or particular qualication. Users
of Bourns® products are responsible for ensuring compliance with safety-related requirements and standards applicable to
their devices or applications.
Bourns® products are not recommended, authorized or intended for use in nuclear, lifesaving, life-critical or life-sustaining
applications, nor in any other applications where failure or malfunction may result in personal injury, death, or severe property
or environmental damage. Unless expressly and specically approved in writing by two authorized Bourns representatives
on a case-by-case basis, use of any Bourns® products in such unauthorized applications might not be safe and thus is at
the user’s sole risk. Life-critical applications include devices identied by the U.S. Food and Drug Administration as Class III
devices and generally equivalent classications outside of the United States.
Bourns expressly identies those Bourns® standard products that are suitable for use in automotive applications on such
products’ data sheets in the section entitled “Applications.” Unless expressly and specically approved in writing by two
authorized Bourns representatives on a case-by-case basis, use of any other Bourns® standard products in an automotive
application might not be safe and thus is not recommended, authorized or intended and is at the user’s sole risk. If Bourns
expressly identies a sub-category of automotive application in the data sheet for its standard products (such as infotainment
or lighting), such identication means that Bourns has reviewed its standard product and has determined that if such Bourns®
standard product is considered for potential use in automotive applications, it should only be used in such sub-category of
automotive applications. Any reference to Bourns® standard product in the data sheet as compliant with the AEC-Q standard
or “automotive grade” does not by itself mean that Bourns has approved such product for use in an automotive application.
Bourns® standard products are not tested to comply with United States Federal Aviation Administration standards generally
or any other generally equivalent governmental organization standard applicable to products designed or manufactured for
use in aircraft or space applications. Bourns expressly identies Bourns® standard products that are suitable for use in aircraft
or space applications on such products’ data sheets in the section entitled “Applications.” Unless expressly and specically
approved in writing by two authorized Bourns representatives on a case-by-case basis, use of any other Bourns® standard
product in an aircraft or space application might not be safe and thus is not recommended, authorized or intended and is at
the user’s sole risk.
The use and level of testing applicable to Bourns® custom products shall be negotiated on a case-by-case basis by Bourns
and the user for which such Bourns® custom products are specially designed. Absent a written agreement between Bourns
and the user regarding the use and level of such testing, the above provisions applicable to Bourns® standard products shall
also apply to such Bourns® custom products.
Users shall not sell, transfer, export or re-export any Bourns® products or technology for use in activities which involve the
design, development, production, use or stockpiling of nuclear, chemical or biological weapons or missiles, nor shall they use
Bourns® products or technology in any facility which engages in activities relating to such devices. The foregoing restrictions
apply to all uses and applications that violate national or international prohibitions, including embargos or international
regulations. Further, Bourns® products and Bourns technology and technical data may not under any circumstance be
exported or re-exported to countries subject to international sanctions or embargoes. Bourns® products may not, without
prior authorization from Bourns and/or the U.S. Government, be resold, transferred, or re-exported to any party not eligible
to receive U.S. commodities, software, and technical data.
To the maximum extent permitted by applicable law, Bourns disclaims (i) any and all liability for special, punitive, consequential,
incidental or indirect damages or lost revenues or lost prots, and (ii) any and all implied warranties, including implied warranties
of tness for particular purpose, non-infringement and merchantability.
For your convenience, copies of this Legal Disclaimer Notice with German, Spanish, Japanese, Traditional Chinese and Simplied Chinese
bilingual versions are available at:
Web Page: http://www.bourns.com/legal/disclaimers-terms-and-policies
PDF: http://www.bourns.com/docs/Legal/disclaimer.pdf
C1753 05/17/18R