FKHD POWER ENTRY MODULES WITH LINE FILTER Actual information about approvals can be found on http://www.schurter.com/approvals C14 70 C Description Characteristics - Panel mount: Screw-on version from front side - 4 Functions: Connector Protection class I, Fuseholder for fuse-links 5 x 20 mm 1pole, Line switch 2-pole, Line-filter in standard version 2-stage Quick connect terminals 6.3 x 0.8 mm - Compact design with optimal shielding All single elements are already wired The fuseholder is accessible from the equipment front Qualified for use in equipment according IEC/EN 60950 Technical data Ratings IEC Ratings UL/CSA Leakage current Dielectric strength Allowable operation temp. Climatic category Degree of protection Protection class Terminals Panel thickness s Materials: Housing 1 [www.schurter.com] 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.25 mA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-inlet /-outlet Fuseholder Power acceptance @ Ta > 23C Line switch Line filter C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I 1-pole, Shocksave category PC2 acc. to IEC/EN 60127-6, for fuse-links 5 x 20 mm Admissible power acceptance at higher ambient temperature see derating curves. Take note of the information GENERAL PRODUCT INFORMATION Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details GENERAL PRODUCT INFORMATION Standard Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details GENERAL PRODUCT INFORMATION FKHD POWER ENTRY MODULES WITH LINE FILTER Dimensions Case 45 Technical data of filter-components Rated current Filter-Type [A] Inductances Capacitance Capacity Cy1 Capacity Cy2 L [mH] CX [nF] [nF] [nF] R [M W] 1 Standard Version 2 x 10 68 1.5 1 1 2 Standard Version 2x4 68 1.5 1 1 4 Standard Version 2 x 1.5 68 1.5 1 1 6 Standard Version 2 x 0.8 68 1.5 1 1 10 Standard Version 2 x 0.3 68 1.5 1 1 Diagrams Standard Version 1) Line 2) only FKID 3) Load Attenuation loss - - - - differential mode Standard version 1A 2A 10 A 2 [www.schurter.com] 4A 6A _____ common mode FKHD POWER ENTRY MODULES WITH LINE FILTER Medical version 1A 2A 4A 6A 10 A Variants Order Number Type Fuseholder Line switch Case 4304.5042 FKHD 2 4304.5043 FKHD 4 Standard Version 1-pole 2-pole 45 Aluminum Standard Version 1-pole 2-pole 45 4304.5044 FKHD Aluminum 6 Standard Version 1-pole 2-pole 45 4304.5045 Aluminum FKHD 10 Standard Version 1-pole 2-pole 45 Aluminum 4304.5001 FKHD 1 Standard Version 1-pole 2-pole 45 Nickel plated steel 4304.5002 FKHD 2 Standard Version 1-pole 2-pole 45 Nickel plated steel 4304.5003 FKHD 4 Standard Version 1-pole 2-pole 45 Nickel plated steel 4304.5004 FKHD 6 Standard Version 1-pole 2-pole 45 Nickel plated steel 4304.5005 FKHD 10 Standard Version 1-pole 2-pole 45 Nickel plated steel Packaging unit 3 Rated current Filter-Type [A] 10 Pcs [www.schurter.com] Materials: Housing