1 Power Protection and Conditioning STFE Elite Series - Active Tracking(R) Filters with Surge Protection Features ** Series connected DIN Rail mounted filter ** Durable metal mount clip ** UL Listed surge current capacity - 45,000 Amps ** Transient protection in all modes (L-N, L-G, and N-G) ** Single Phase applications up to 20 Amp ** Operating Temperature from -40C to +50C The SolaHD STF Elite DIN Rail Mount Series combines Active Tracking(R) technology with UL Listed surge protection to protect against the full spectrum of voltage transients and surges. It continuously tracks the input AC power line responding instantly into action upon detecting extraneous high frequency noise and high voltage transients caused by everyday events such as turning on machinery, motors, or equipment. These devices are designed to meet UL 1449 3rd Edition, UL 1283, cUL recognized, and CE. STFE attenuates or reduces the amplitude of normal mode noise to a minimum of 90dB that occurs in a frequency range of 100KHz to 50MHz, and of common mode noise to a minimum of 60dB that occurs in a frequency range of 5MHz to 50MHz. STFE provides the industry's best IEEE C62.41 Category "A & B" Ringwave protection. They are built to meet your unique requirements, and are available in hardwired DIN Rail mount, single phase configuration. They are designed for years of trouble free operation and require little or no operator intervention after installation. Related Products ** Power Conditioners ** Uninterruptible Power System ** Power Supplies 24 ** Screw Terminal Connections - Reliable and convenient screw clamp connections - Accept 10-16 AWG wire - Meet IP20 specifications for ingress protection * LED status indication ** Form C contact for remote monitoring ** UL 1449 3rd Edition, UL 1283, cUL recognized component, CE ** 5 Year Limited Warranty Applications ** Control Panels ** Factory Automation Installations ** Point of Use Industrial Equipment ** Programmable Logic Controllers ** Dedicated Industrial and Machine Tools Equipment Selection Table Catalog Number Input Voltage STFE030-10N 120 V Single Phase 2 Wire + Ground STFE050-10N 120 V Single Phase 2 Wire + Ground STFE100-10N 120 V Single Phase 2 Wire + Ground STFE200-10N 120 V Single Phase 2 Wire + Ground STFE030-24L 240 V Single Phase 2 Wire + Ground STFE050-24L 240 V Single Phase 2 Wire + Ground STFE100-24L 240 V Single Phase 2 Wire + Ground STFE200-24L 240 V Single Phase 2 Wire + Ground Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 1 Power Protection and Conditioning STFE Specifications Description Input Voltage STFEXXX-10N STFEXXX-24L 120 V (0-150 VRMS) 240 V (0-275 VRMS) Line Frequency 47 - 63 Hz Response Time < .5 ns normal mode, <5 ns common mode Fully Enclosed Metal Housing Enclosure Reference Fuse/Circuit Breaker Chart Fusing Green LED "OK"/Form C Contact/10 Amps @ 250 Vac or 5 Amps @ 100 Vdc Status Indication DIN Rail Mount Connection/Mounting Type -40C to +50C at full load Derate Linearly to 60% at +70C Operating Temperature 1.7 lbs (0.7kg) Weight (Kg) 4.88 x 2.56 x 4.56 (124 x 65 x 116) Dimensions - in (mm) (H x W x D) 0% to 95% Non-condensing Operating Humidity Peak Surge Current Capability Per Phase 30,000 Amps Line to Neutral 20,000 Amps Line to Ground 10,000 Amps Neutral to Ground 10,000 Amps 10m Sec 5 x Nominal 1 sec 3 x Nominal 10 sec 2 x Nominal 100 kHz to 50 MHz 90 dB Max Load Surge Current Rating Frequency Response Normal Mode (Forward-Reverse) Common Mode (Forward-Reverse) Transient Reduction (IEEE C62.41) 5 MHz to 50 MHz 60 dB Max Typical Category A Ringwave (6 kV, 200A, 100 kHz) < 60 V Peak Typical Category B Ringwave (6 kV, 500A, 100 kHz) <100 V Peak UL 1449 UL 1449 3rd Edition, UL1283, cUL Recognized Component, CE Safety Connection Diagram LINE INPUT FROM SOURCE L/L1 N/L2 GND LINE LOAD L/L1 L/L1 N/L2 N/L2 RELAY CONTACTS GND NO COM NC GND L/L1 N/L2 TO LOAD OR EQUIPMENT PROTECT GND TO REMOTE INDICATION IF NEEDED Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 25 1 Power Protection and Conditioning Dimensional Diagram Wiring Specifications 2.560 Catalog Number Amps Min Wire Size* (AWG Suggested) Fuse/Circuit Breaker Ampacity Suggest Max Single-Phase Models (120 Vac) L/L1 N/L2 Active Tracking Filter STFE Elite Series 4.880 STFE030-10N 3.0 24 3A 3.75A STFE050-10N 5.0 22 5A 6.25A STFE100-10N 10.0 20 10A 12.5A STFE200-10N 20.0 12 20A 25A STFE030-24L 3.0 24 3A 3.75A STFE050-24L 5.0 22 5A 6.25A STFE100-24L 10.0 20 10A 12.5A STFE200-24L 20.0 12 20A 25A Single-Phase Models (240 Vac) NO COM NC L/L1 N/12 4.560 *16 AWG wire or larger may be required by code dependent upon the application. Internal Diagram Rear View Internal View of Components DIN Connector Strong all metal for horizontal or vertical mounting Finger Safe Terminals MOV Array provides high-energy all mode protection Green LED Unit Status Indicator Series Blocking Inductor blocks voltage, smooths current Silicone Avalanche Diodes fast responding surge suppressor Pulse Capacitor high-frequency noise absorption 26 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. Form C Relay Contacts DC OK signal