Data Sheet AT-5000 Professional Underground Cable / Pipe Locator System Buried Utilities represent a major challenge to electricians who need to trace and trouble shoot such systems. They also represent a hazard to excavation crews. Improperly performed digging can cause cable or pipe damage resulting in personal injury, costly repairs and penalties. This product is faster and more accurate than what's available on the market today. No hassle warranty No waiting. No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive "No Hassle" warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. Using superior design and powerful software, the AT-5000 offers several new performance features, establishing them as the new standard for locating and pinpointing faults in the underground systems. Distance sensitive Left / Right indication guides the user to the exact location of the buried utilities which saves time and effort not available on standard locators. The Signal Select and Distortion Alert provide superior accuracy by visually indicating a clean signal of the traced line, versus "ghost" and `return' path of false signals coming from the neighboring lines, and keeping the user on the target line. The core of the AT-5000 Utility Locating Systems is the ergonomically designed handheld receiver. Designed for comfort, the lightweight receiver is balanced for all day use. The receiver's bright color display is complete with intuitive, easily read graphics that can be viewed in all lighting conditions. (note: $500 MSLP limit) 600V Amprobe(R) Test Tools www.Amprobe.com Data Sheet Locates underground energized and de-energized wires, cables and pipes, eliminates exploratory digging in parking lots or under floors for buried pipes and wires New technology makes tracing much faster, accurate and unambiguous when compared to standard locators: - Signal Select and Distortion Alert icon indicates clean signal of the traced line, versus "ghost" and `return' path signals coming from the neighboring lines - Forward-looking Guidance Coil alerts for bends and "T" - Distance Sensitive Left / Right Guidance guides the user to the exact location of the buried utilities and eliminates "blind" searches for the line Three testing modes for best accuracy: - Passive Power Mode (50, 60, 100 and 120 Hz) - tracing energized lines conducting current - Passive Radio Mode (RF) - using surrounding radio waves to trace underground object - Active Mode - T-5000 signal generator with broad frequency selection between 491 Hz and 166 kHz with induction mode or directly connected to the cable with test leads or optional clamp Active Mode Depth measurement up to 20' (6m) Bright Color 1/4 VGA receiver graphical display and audible signal indicators provide clear reading to the user Strong testing signal generated by 10 Watt variable output transmitter for dependable depth and distance locating Powerful Digital Signal Processing in both receiver and transmitter provides outstanding performance in tracing when compared to analog devices Automatic or manual gain mode allows respectively quick and easy tracing of the line or precise pinpointing of the fault Receiver Bluetooth(R) wireless communication for downloading relevant images and archiving of meaningful digital information (previous survey results) Ground Fault Locating with A-Frame adapter for power and telecom cables (optional for AT-5000) Precise pinpointing of buried services and exceptionally fast sound and meter response Rugged durable construction, weatherproof and drop resistant to 3' Includes receiver (R-5000), transmitter (T-5000), connection cable, ground stake, ground cable, and and carrying case Amprobe(R) Test Tools www.Amprobe.com AT-5000 Professional Underground Cable / Pipe Locator System Data Sheet Specifications Depth Measurement Passive Tracing Frequencies Transmitter frequency A-Frame Ground Fault Locating R-5000 Active Frequencies (Hz) R-5000 Passive Frequencies (Hz) R-5000 Depth Display Accuracy R-5000 Depth Range R-5000 Gain Adjustment R-5000 Controls R-5000 Display Indicators R-5000 Line ID R-5000 Display R-5000 Antenna R-5000 Data Acquisition R-5000 Operating Temperature R-5000 Battery Type R-5000 Battery Life R-5000 Battery Check R-5000 Dimensions R-5000 Weight R R-5000 egulatory Compliance R-5000 Environmental T-5000 Output Frequencies (Hz) T-5000 Output Power T-5000 Simultaneous Output T-5000 Controls T-5000 Display Indicators T-5000 Display T-5000 Battery Type T-5000 Battery Life T-5000 Operation Temperature T-5000 Dimensions T-5000 Weight T-5000 Regulatory Compliance T-5000 Environmental Amprobe(R) Test Tools 16 ft 50, 60, 100 and 120 Hz Adjustable from 491 to 166 kHz Optional 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America) 491, 512, 577, 640, 982, 8k, 8.44k, 9.82k, 35k, 65.5k, 82k, 83k 50, 60, 100, 120, RF (14k-21k) Extended and special frequency sets available 0-10ft: (5%+2") under ideal field conditions 10-20ft: 10% under ideal field conditions Maximum 20ft (600 cm) Automatic & manual with pushbutton centering Four-way navigation key and soft keys Frequency Audio volume, battery condition, Guidance CompassTM, Distortion AlertTM, Signal SelectTM, signal strength, Distance Sensitive Left/ Right GuidanceTM, menu softkey, frequency softkey Signal Select, Guidance Compass, Distortion Alert 1/4 VGA Bright Color Distance Sensitive Left/Right Guidance Internal data logging memory -4F to +122F (-20C to +50C) Li-ion rechargeable 9 AA Alkaline 30 hours continuous Continuous display 8 1/4" W x 13 1/4" H x 29" L (21.0cm x 33.7 cm x 74.3cm) 4.9 lb (2.2 kg) FCC, CE IP54 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America) 491, 577, 640, 982, 8.192k, 8.44k, 9.82k, 35k, 82k, 83k Extended and special frequency sets available Variable to 10W Up to three active frequencies Frequency select, measurement units (mA, Volts, Ohms, Watts), output power, Signal SelectTM, menu, 4-way navigation, select, SFL, On/Off Battery status, audio volume, output mode, frequency setting, frequency out put, % output in SFL or induction mode, output graph, loop resistance graph 1/8 VGA monochrome NiMH rechargeable or six (6) D alkaline 6 - 12 hours continuous use, depending on power level and line conditions -4F to +122 F (-20C to +50 C) 11" W x 6 3/4" H x 9" L (27.9 cm x 17.1 cm x 22.9 cm) 8.24 lbs. (3.7 kg) FCC, CE IP54 www.Amprobe.com Data Sheet AT-5000 Professional Underground Cable / Pipe Locator System Included Accessories Receiver (R-5000), Transmitter (T-5000), connection cable, ground stake, ground cable, and carrying case Optional Accessories A-5000 SC-5000 M-5000 BT-5000 A-Frame Ground Fault Locator 4" Signal Clamp for AT-5000 series Sonde Pipe transmitter for AT-5000 series Rechargeable battery pack for transmitter AT-5000 series (requires EPS-5000 charging kit) Amprobe(R) Test Tools website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE Amprobe(R) Test Tools Amprobe(R) Test Tools Europe Amprobe Test Tools Europe Beha-Amprobe GmbH In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0 (c)2009 Amprobe Test Tools. All rights reserved. 09/2009 3520648A www.Amprobe.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: AMPROBE: AT-5000