DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
Page 1 of 2
D
TWO CONDUCTOR CABLE, SHIELDED, JACKETED,
GENERAL PURPOSE, 1000 VOLT
SPECIFICATION CONTROL DRAWING Date Revision
SHIELD - COPPER, COATING SAME AS ON
CONDUCTOR EXCEPT TIN-COATED
SHIELD WITH SILVER-COATED HIGH
STRENGTH ALLOY CONDUCTOR
COMPONENT WIRE - 44A021X
PART NUMBER
1/
BEND TESTING WEIGHT
(lb) (± 3%)
MANDREL DIAMETER
(inch) (± 3%)
NOTE: Nominal values are for information only.
Nominal values are not requirements.
MAXIMUM
WEIGHT
(lb/1000 ft)
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
SHIELD
SIZE
(AWG) MINIMUM
JACKET
THICKNESS
(in.)
OUTSIDE
DIAMETER
(in.)
MAXIMUM
NOMINAL
NOMINAL
JACKET - RADIATION-CROSSLINKED,
MODIFIED PVF2
This specification sheet forms a part of the latest issue of Raychem Specification 44.
44A122X
TITLE
TABLE I. CABLE CONSTRUCTION DETAILS
TABLE II. CABLE PERFORMANCE DETAILS
LIFE CYCLE, IMMERSION
AND ACCELERATED AGING COLD
BEND
COLD
BEND
LIFE CYCLE, IMMERSION
AND ACCELERATED AGING
1-9-06
R Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
© 2006 Tyco Electronics Corporation. All rights reserved.
44A122X-26-*
44A122X-24-*
44A122X-22-*
44A122X-20-*
44A122X-18-*
44A122X-16-*
44A122X-14-*
44A122X-12-*
44A122X-10-*
44A122X- 8-*
44A122X- 6-*
44A122X- 4-*
26
24
22
20
18
16
14
12
10
8
6
4
36
36
36
36
36
36
36
36
36
36
34
34
10.3
12.9
16.2
20.7
27.9
33.4
45.9
64.3
96.3
161.
247.
377.
.124
.136
.152
.169
.193
.210
.244
.286
.351
.481
.586
.705
.118
.130
.146
.162
.186
.202
.236
.276
.334
.458
.558
.672
.008
.008
.008
.008
.009
.009
.009
.010
.010
.012
.012
.015
.006
.006
.006
.006
.007
.007
.007
.008
.008
.010
.010
.013
44A122X-26-*
44A122X-24-*
44A122X-22-*
44A122X-20-*
44A122X-18-*
44A122X-16-*
44A122X-14-*
44A122X-12-*
44A122X-10-*
44A122X- 8-*
44A122X- 6-*
44A122X- 4-*
.375
.375
.375
.500
.500
1.00
1.00
1.50
2.00
3.00
3.00
3.00
3.00
6.00
6.00
9.00
9.00
12.0
12.0
12.0
12.0
15.0
24.0
24.0
3.00
6.00
6.00
6.00
6.00
6.00
6.00
10.0
10.0
18.0
18.0
18.0
3.00
6.00
6.00
6.00
6.00
6.00
6.00
10.0
10.0
18.0
18.0
18.0
Page 2 of 2 SCD Number
SPECIFICATION CONTROL DRAWING
Revision
D44A122X
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 1000 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 6 hours
BLOCKING: 150 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 3000 volts (rms), 60 Hz, 1 minute
FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no flaming of facial tissue
IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown
JACKET COLOR: White preferred
JACKET CONCENTRICITY: 70% (minimum)
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 200% (minimum)
Tensile Strength, 4000 lbf/in² (minimum)
JACKET FLAWS:
Spark Test, 1.5 kV (rms)
Impulse Dielectric Test, 6.0 kV (peak)
LIFE CYCLE: 200 ± 3°C for 168 hours
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND TEST (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute
PART NUMBER:
The “X” in the part numbers on page 1 shall be replaced by the applicable
conductor material designator as follows:
1 tin-coated copper
2 silver-coated copper
3 nickel-coated copper
4 silver-coated high strength copper alloy (AWG's 26-16 only)
6 nickel-coated high strength copper alloy (AWG's 26-20 only)
The "*" in the part numbers on page 1 shall be replaced by color code designators
with a dash separating the component wire color from the jacket color.
1/ Example: AWG 20, tin-coated copper, black and brown component wires;
white jacket: 44A1221-20-0/1-9
1/ see footer section on page 1
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TE Connectivity:
44A1221-18-0/9-9