8
AGNW Series Control Stations
IP65 Waterproof Aluminum Control
Stations for ø22 mm Switches/Pilot Lights
AGAW control stations are designed for mounting IDEC ø22 mm (7/8 inch)
switches/pilot lights.
Various control stations are available from one to four holes with most
widely used combinations of switches/pilot lights (contact configura-
tions, voltage, button colors, and nameplates).
Enclosures only are also available, in which specifically selected TW
series can be installed.
200 mm
AGAW Control Box with
four
ø22 mm switches/pilot
lights
AGA Control Box
with
three ø30 mm
switches/pilot lights
Ideal for small control
boxes
HW series can also be installed.
Specifications
Degree of Protection
(Note)
IP65 (IEC60529)
(Key selector switch: Splash-proof IP54)
Material (Box) Aluminum alloy die-cast
Coating Color
(Melamine coating) Yellow semi-gloss (Munsell 5Y7/1, outside only)
Rated Insulation
Voltage 600V
Insulation
Resistance 5 MΩ minimum
Dielectric Strength Between live and dead parts:
2500V AC, 1 minute
Standard Operating
Conditions
Ambient temperature:
-
25 to +50°C (no freezing)
Relative humidity: 45 to 85% (no condensation)
Style Wall mount (1 to 4 holes)
Pole mount (1 to 4 holes)
Cable Lead-in
(Wall Mount)
Entrance hub
1 to 3 holes: HNA22 G3/4 (22 mm)
4 to 5 holes: HNA33 G1 (28 mm)
Applicable Switches/Pilot
Lights
IDEC ø22 mm TW series
Note: The degree of protection depends on the switches/pilot lights mounted in the
enclosure. When IP65 switches/pilot lights are mounted, the entire control station
has IP65 characteristics. (See page 2)
Contact Ratings (Contact Block)
Contact Block
Rated Insulation Voltage 600V
Rated Thermal Current 10A
Contact Ratings by Utilization Category
IEC60947-5-1
AC-15 (A600)
DC-13
Operational Voltage and Current by Utilization Category
Operational Voltage 24V 48V 50V
110V 220V 440V
Operational Current
AC
(50/60Hz)
AC-12 Control of
resistive loads and
solid state loads
10A 10A 10A 6A 2A
AC-15 Control of
electromagnetic
loads (>72VA)
10A 7A 5A 3A 1A
DC
DC-12 Control of
resistive loads and
solid state loads
8A 4A 2.2A 1.1A
DC-13 Control of
electromagnets 4A 2A 1.1A 0.6A
Common
Minimum applicable load (reference) = 3V AC/DC, 5mA (the applicable range is
subject to change according to the operating conditions)
Switch/Pilot Light Mounting Holes
The holes for mounting switches/pilot lights are 22.2 mm in diameter with an
anti-rotation notch.
Mounting centers are 50 mm on 2- and 3-hole enclosures, and 36 mm on
4-hole enclosures.
Waterproof Bushing
Four plastic bushings are provided inside the corners for mounting screws to
secure the control station on a panel surface.
Lead-in Fittings (Wall Mount)
An entrance hub made of aluminum is supplied for connecting a steel conduit
to lead in cables.
1 to 3 holes: With HNA22 G3/4 for 22 mm conduit
4 holes: With HNA33 G1 for 28 mm conduit
HNAG gland hubs for lead in cables are also available.
Stand Pole (Pole Mount)
The pole is made of carbon steel pipe, and the base is made of cast iron. The
coating color is the same as the enclosure, yellow (semi-gloss).
Enclosure
Switch/Pilot Light
Stainless Steel
Screws
Pole
BaseWaterproof Bushing
Entrance Hub
Unit Mounting
Hole
9
AGNW Series Control Stations
Control Stations with Switches/Pilot Lights
The control stations are available with a selected combination of
switches/pilot lights as listed below. For the dimensions and mounting
centers, see the figures on page 10.
Switch/Pilot Light Part No. Specifications
Pushbutton
PB
ABW110 *Flush, 1NO
ABW101 *Flush, 1NC
ABW111 *Flush, 1NO-1NC
ABW411 *ø40 mushroom, 1NO-1NC
Pilot Light
PL
(LED)
APW116D *Round flush, 100/110V AC
APW126D *Round flush, 200/220V AC
Selector Switch
SS
ASW211 Knob, 2-position, 1NO-1NC
ASW320 Knob, 3-position, 2NO
ASW2K11 Key, 2-position, 1NO-1NC
Note: Specify a button or lens color code in place of * :
Pushbutton: B (black), G (green), R (red)
Pilot Light: G (green), R (red), W (white)
Control Stations Package Quantity: 1
Control Station Mounted Switches/Pilot Lights
Style Part No. Symbol Part No. NWA Nameplate
Legend
Wall Mount
1 hole
AGAW1101Y PB ABW110B ON
AGAW1102Y PB ABW411R Without nameplate
AGAW1105Y SS ASW211 HAND-AUTO
AGAW1107Y *SS ASW2K11 OFF-ON
Pole Mount
1 hole
AGAW1101SY PB ABW110B ON
AGAW1102SY PB ABW411R OFF
Wall Mount
2 holes
AGAW2101Y PB
PB
ABW110B
ABW101R
ON
OFF
AGAW2102Y PB
PB
ABW111B
ABW111R
ON
OFF
AGAW2103Y PL
PL
APW116DR
APW116DG Without nameplate
AGAW2104Y PL
PL
APW126DR
APW126DG Without nameplate
AGAW2105Y PL
PB
APW116DR
ABW111DR
Without nameplate
STOP
AGAW2106Y PL
PB
APW126DR
ABW111R
Without nameplate
STOP
AGAW2107Y PL
SS
APW116DR
ASW211
Without nameplate
HAND-AUTO
Degree of protection marked with * is splash-proof IP54.
Control Station Mounted Switches/Pilot Lights
Style Part No. Sym-
bol Part No. NWA Nameplate
Legend
Wall Mount
2 holes
AGAW2108Y PL
SS
APW126DR
ASW211
Without nameplate
HAND-AUTO
AGAW2109Y *PL
SS
APW116DR
ASW2K11
Without nameplate
OFF-ON
AGAW2110Y *PL
SS
APW126DR
ASW2K11
Without nameplate
OFF-ON
AGAW2113Y PB
PB
ABW110B
ABW411R
ON
Without nameplate
Pole Mount
2 holes AGAW2101SY PB
PB
ABW110B
ABW101R
ON
OFF
Wall Mount
3 holes
AGAW3102Y
PL
PB
PB
APW116DR
ABW110B
ABW101R
Without nameplate
ON
OFF
AGAW3103Y
PL
PB
PB
APW126DR
ABW110B
ABW101R
Without nameplate
ON
OFF
AGAW3104Y
PB
PB
SS
ABW111B
ABW111R
ASW211
ON
OFF
HAND-AUTO
Pole Mount
3 holes
AGAW3102SY
PL
PB
PB
APW116DR
ABW110B
ABW101R
Without nameplate
ON
OFF
AGAW3104SY
PB
PB
SS
ABW111B
ABW111R
ASW211
ON
OFF
HAND-AUTO
Wall · Pole
4 holes
Wall Mount
AGAW4101Y PL
PL
PB
PB
APW126DR
APW126DG
ABW111B
ABW111R
Without nameplate
Without nameplate
ON
OFF
Pole Mount
AGAW4101SY
Wall Mount
AGAW4102Y PL
PB
PB
SS
APW126DR
ABW111B
ABW111R
ASW211
Without nameplate
ON
OFF
HAND-AUTO
Pole Mount
AGAW4102SY
Degree of protection marked with * is splash-proof IP54.
10
AGNW Series Control Stations
Empty Enclosures Package Quantity: 1
Style Part No. Unit Mounting
Hole
Switch/Pilot Light
Mounting Centers
1 hole
(approx. 0.6 kg)
AGAW211Y With
G3/4
(
22mm
)
Hub HNA22
NP
AGA210Y Without
2 holes
(approx. 0.6 kg) AGAW212Y With
NP
2723
G3/4
(
22mm
)
Hub HNA22
3 holes
(approx. 0.7 kg)
AGAW313Y With
NP
502
48
G3/4 (22mm)
Hub HNA22
AGA310Y Without
4 holes
(approx. 0.7 kg) AGAW314Y With
NP
36
G1
(28mm)
Hub HNA33
4 holes
(approx. 0.9 kg) AGAW514Y With
505050
NP
5 holes
(approx. 0.9 kg)
KGNW515Y With
505050 48
2
NP
KGN510Y Without
Switch/Pilot Light Mounting Hole
24
3.
5
ø22.2
An entrance hub is supplied.
1 to 3 holes: With HNA22 G3/4 for 22 mm
conduit
4 holes: With HNA33 G1 for 28 mm
conduit
77
70
79
Standard
Dimensions All dimensions in mm.
AGAW Control Station (Wall Mount)
(72) (1.2)
(95) (132)
82
86
L
30
30max.
Shade
Hub
M4 grounding terminal
HNA22: 31
HNA33: 35
Nameplate
O N
O F F
4-ø4.4
Mounting holes
60 (Centers)
I
Entrance Hub (attached)
1 to 3 holes: HNA22 G3/4 (22 mm)
4 holes: HNA33 G1 (28 mm)
Gland hubs for leading in cables are also available.
See page 39 for details.
Part No. Applicable Cable
Diameter (R)
HNG21 8, 10, 12
HNAG22 13, 15, 17
HNAG33 18, 20, 22
1 hole 2 holes 3 holes 4 holes 5 holes
211Y
(210Y ) 212Y 313Y 314Y 514Y 515Y
(510Y)
L150 150 200 200 300 300
l114 114 164 164 264 264
Weight
(Approx.) 0.6 kg 0.6 kg 0.7 kg 0.7 kg 0.9 kg 0.9 kg
AGAW Control Station (Pole Mount)
ø200
(1.2)
(72)
ø230
10
100 L
H
86 82
4-ø14
M6
Grounding
terminal
Shade
1 hole 2 holes 3 holes 4 holes 4 holes 5 holes
H1350 1400 1500 1500
L 150 200 300 300
Weight
(Approx.) 6.1 kg 6.2 kg 6.4 kg 6.4 kg
24
3.
5
ø22.2
Effective Depth inside the Enclosure
11
AGNW Series Control Stations
Accessory (Options) Package Quantity: 1
Name & Shape Part No. Description & Dimensions
Enclosure Shade
132
95
70
Material: Carbon steel plate
Thickness: 1 mm
Weight: Approx. 0.25 kg
AGZ-S1Y
Protection for switches/pilot lights against direct sunlight and falling objects.
Color: Yellow (semi-gloss)
Shade mounting hole
2-M4 tapped hole: Depth 5
Pilot hole: Depth 5.5 max.
(no penetration)
68
46.5
Stand Pole
Weight: Approx. 5.6 kg
AGZ-S205
For replacement of the base and pole.
Color: Yellow (semi-gloss)
(1005)
ø52
4-ø6.5 Hole
65
51
72
50
10
(1199)
(8 to 9)
94
2
100
ø230
ø200
Sealing base
Grounding
terminal
(8 to 9)
Pole
Outside Dia.: ø48.6
Inside Dia.: ø44.0
Stand gasket
Base
4-ø14 Hole
Instructions
Precautions for Mounting on Panel (Wall)
1. Insert M4 screws into the
waterproof bushings at all four
corners inside the box. Push the
screws with a screwdriver and
penetrate the bushings (Figure
1).
2. Thrust the screws into panel
holes and secure the screws
with nuts (Figure 2). Waterproof
characteristics are not affected
by piecing the bushings with
screws.
Ordering Information
When ordering control stations with switches/pilot lights:
Specify the Part No. of the control station.
When ordering enclosures without switches/pilot lights:
Specify the following items.
1. Part No. of the enclosure
2. Part No. and specifications of the switches/pilot lights to be mounted (lens
color, button color, etc.)
3. Nameplate
4. Lead-in fitting
Only when ordering the gland hub for leading in cables, specify the Part No.
and the finished cable outside diameter (R).
5. Other specifications
Ordering Example
Note: Any ø22 mm TW/HW series are selectable. Take into consideration the
degree of protection of the switches/pilot light and the effective depth of
the enclosure.
Figure 1
Box
Waterproof Bushing
13
Figure 2
Panel surface Part No. of Enclosure AGAW313Y
Switch/Pilot Light
and Nameplate
APW126DR
ABW210G, with NWA-1
ABW201R, with NWA-2
Lead-in Fitting HNAG22 R15
All dimensions in mm.