MICRO SWITCH Cable-Pull Safety Switches CPS Series 004785 Issue 5 Datasheet FEATURES DESCRIPTION Honeywell's MICRO SWITCH CPS Series Cable-Pull Safety Switches provide a readily accessible emergency stop signal, a cost-effective means compared to using multiple emergency stop push-buttons. The CPS Series Cable Pull Safety Switch's internal mechanism latches on both slackened cable (push) and pulled cable. The 1CPS is intended for use in applications where the cable span is 76 m [250 ft] or shorter. It is an economical solution for shorter runs or zone protection typical to automated systems. The 2CPS Series is intended for use in very long cable runs of 152 m [500 ft] or shorter, such as long conveyor lines found in warehouses. A line in the midpoint of the cable tension window indicates proper cable tension, providing easy set-up. The direct opening switch contacts are held closed when the actuating cable is under proper tension and the reset knob is set to the RUN position. When the actuating cable is pulled, slackened, or broken, a cam positively opens the NC (Normally Closed) switch contacts. The snap-action operation causes the switch contacts to change state and mechanically latch almost simultaneously when the cable is pulled, slackened, or broken. The NC switch contacts remain open until the CPS is reset by properly tensioning the cable and manually rotating the reset knob. When the direct opening switch contacts open, the auxiliary contacts also actuate (open contacts close). The auxiliary contacts are electrically isolated from the direct-opening switch contacts. These NO (Normally Open) contacts may be used for monitoring or signaling. DIFFERENTIATION * Internal mechanism latches on both slackened cable (push) and pulled cable Sensing and Internet of Things * Direct opening action of NC (Normally Closed) contacts * 2CPS: 2NO/2NC, 1NO/3NC, or 4NC contact configurations * 1CPS: 1NO/1NC, 2NO/2NC, 1NO/3NC, or 4NC contact configurations * Typical cable span of 76 m [250 ft] in an environment with a temperature change of 17 C [30 F]. Longer spans are possible depending upon temperature change and installation * Choice of three actuator configurations (2CPS) * Removable contact block version available (2CPS) * J-hook turnbuckle included (2CPS) * E-stop option (1CPS) * Low profile reset and new indicator options (2CPS) * Large wiring cavity with straight-through wiring * Models avaliable without broken cable, slack-cable detection * 24 Vdc or 120 Vac bright, multi-cluster high-intensity LED status indicator light available on 2CPS. Single LED on 1CPS. Low profile LED (2CPS) and emergency stop button (1CPS) options also offered * Gold-plated contacts are standard on 2CPS, available on 1CPS * Electrostatic, epoxy-coated, die-cast zinc housing * Optional hardware packets available POTENTIAL INDUSTRIAL APPLICATIONS * Long conveyor systems found in warehouses and distribution centers * Conveyor systems with a high amount of vibration * Conveyor systems that experience wide temperature swings * Long conveyor systems where easy-through wiring, or highly visible trip status, is required * Perimeter guarding in hose-down conditions * Packaging equipment * Assembly lines VALUE TO CUSTOMERS * Cost-effective means of providing an emergency stop signal compared to multiple emergency stop push buttons * Capability enhances productivity by minimizing nuisance stops due to variations in temperature, stretch of cable over time, or other application variables * Direct opening of normally closed contacts when cable is actuated PORTFOLIO The CPS Series is the largest switch in Honeywell's MICRO SWITCH line of safety switches. For more details on the extensive line of Honeywell safety switches, click here. MICRO SWITCH Cable-Pull Safety Switches, CPS Series Table 1. Specifications Characteristic Parameter Description cable-pull safety switches Switching options 1NO/1NC direct acting 2NO/2NC direct acting 1NO/3NC direct acting 4NC direct acting Sealing IP67, NEMA 1, 4, 12, 13 Contacts silver, gold plated over silver Conduit/Connectors 1/2 NPT, PG 13.5, 20 mm, PF 1/2; Brad Harrison 10-pin conductor Force to maintain actuation shaft 1CPS & 2CPS: 25 lb* Actuation shaft operating force 1CPS & 2CPS: 40 lb* Operating temperature -40 C to 80 C [-40 F to 176 F] Storage temperature 1CPS: -40 C to 85 C [-40 F to 185 F] Mechanical endurance 1 million operations Rated thermal current (Ith) 10 A Rated impulse withstand (Uimp) 2500 V Rated insulation voltage (Ui) 300 V Useable gold-plated current 1 mA to 50 mA, 60 Vdc max./125 Vdc max. Pollution degree 3 Conditional short circuit current 1000 A Short circuit protective device (type/maximum rating) Class J fuse (10 A/600 V) Shock 15 g per IEC 68-2-27 Vibration 10 Hz to 500 Hz, 5 g per IEC 68-2-6 Approvals UL, CSA, CE, SIL Standards * UL Listed per File E37138 against UL508 * CSA Certified per File 57323 against CSA C22.2 No. 14 * CE mark: The CPS complies with Low Voltage Directive 2006/95/EC; Machinery Directive 2006/42/EC only as the directives relate to the components being used in a safety function; EN 60947-1; EN 60947-5-1; EN 60947-5-5 * SIL: MCTF (Mechanical Life): >1,000,000 cycles with single-sided confidence limit of 100 %. MCTF (Electrical Life): >25,000 cycles with single-sided confidence limit of 87.5 %. Highest SIL Capability: SIL3 (HFT:1), IEC 61508-2: 2010. Proof Test Interval: 1 Year * Incline measures, and not typical for manual trip Table 2. Electrical Ratings ac dc A300 Ue AC15 Ie Q300 Ue DC13 Ie Volts Amps Volts Amps - - 24 2.8 120 6 125 0.55 240 3 250 0.27 Ith = 10 A 2 sensing.honeywell.com MICRO SWITCH Cable-Pull Safety Switches, CPS Series Figure 1. 1CPS Product Nomenclature and Order Guide 1CPS A 1 A Switch Type Conduit Basic Switch Code Indicator-Pilot Light Code 1CPS Series Single-Head A Cable-Pull B Safety Switch 1NO/1NC direct acting Switch 1: 1NO/1NC Switch 2: None 1/2 NPT 1 PG 13.5 2 C 20 mm 3 2NO/2NC direct acting Switch 1: 1NO/1NC Switch 2: 1NO/1NC 1NO/3NC direct acting Switch 1: 1NO/1NC Switch 2: 2NC D PF 1/2 4 4NC direct acting Switch 1: 2NC Switch 2: 2NC 7 1NO/1NC direct acting, gold contacts Switch 1: 1NO/1NC Switch 2: None 2NO/2NC direct acting, gold contacts Switch 1: 1NO/1NC Switch 2: 1NO/1NC 1NO/3NC direct acting, gold contacts Switch 1: 1NO/1NC Switch 2: 2NC 8 4NC direct acting, gold contacts Switch 1: 2NC Switch 2: 2NC 5 6 - (None) No indicator light A 24 Vdc LED B 120 Vac LED Modification Code Emergency Stop 1 10-pin Brad Harrison (None) No emergency stop on bottom, F01 connector actuator to right with emergency stop on bottom, F02 connector actuator to left 10-pin Brad Harrison 10-pin Brad Harrison on bottom, F03 connector actuator to top NOTE: Not all combinations of model code are available. Please contact your Honeywell provider/representative for assistance. Figure 2. 2CPS Product Nomenclature and Order Guide 2CPS A 1 A 1 A A Switch Type Conduit Contact Mounting Code Basic Switch Code Actuation Code Indicator-Pilot Light Code Accessory Switch Code 2CPS Series A Dual-Head Cable-Pull B Safety Switch 1/2 NPT 1 Standard: contact block mounted to housing A 2NO/2NC, direct acting Switch 1: 1NO/1NC Switch 2: 1NO/1NC 1 Maintained, both sides PG 13.5 2 Removeable: contact blocks with receptacles B 1NO/3NC, direct acting Switch 1: 1NO/1NC Switch 2: 2NC 2 Maintained, left side No actuation, right side A 24 Vdc LED cluster 1 1NO, momentary D 4NC, direct acting Switch 1: 2NC Switch 2: 2NC 3 Maintained, right side No actuation, left side B 120 Vac LED cluster 2 1NC, momentary 4 Maintained, both sides w/o broken cable detection C 3 1NO, maintained 5 Maintained, left side No actuation, right side w/o broken cable detection D 24 Vdc LED cluster, low profile 120 Vac LED cluster, low profile 4 1NC, maintained 61 Maintained, right side No actuation, left side w/o broken cable detection C 20 mm D PF 1/2 NOTE: Not all combinations of model code are available. Please contact your Honeywell provider/representative for assistance. 1 (None) No acc. switch (None) No indicator Not valid on 4NC switches Sensing and Internet of Things 3 MICRO SWITCH Cable-Pull Safety Switches, CPS Series TEMPERATURE-SPAN DISTANCE APPLICATION INFORMATION Cable-pull switches featuring broken cable detection require pre-tensioning in order to enable the RUN condition. The relative expansion or contraction of the steel actuating cable when the ambient temperature increases or decreases must be taken into account when pre-tensioning a cable pull switch. Table 3. Circuitry Charts Circuitry Chart 1NO/1NC 2NO/2NC The change in cable length with change in temperature can cause significant nuisance shut downs on longer runs. Install the system when the temperature is at the mid point of the extremes. If a warehouse has a low temperature of 15.6 C [60 F]and a high of 32.2 C [90 F], set up the system at the midpoint 23.9 C [75 F]. 1NO/3NC Use an endspring or another CPS at the opposite end of the cable span to double the temperature tolerance and to meet the requirements of EN 418. 4NC Figure 3. Total Temperature Variation vs. Cable Span Distance 1NO/1NC 1NO/3NC 2NO/2NC 4NC Table 4. 1CPS Contact Blocks = grounding screw 4 sensing.honeywell.com MICRO SWITCH Cable-Pull Safety Switches, CPS Series Table 5. 2CPS Contact Blocks Removable Contact Blocks with Heavy-Duty Wiring Receptacles Contact Block Mounted to Housing A = grounding screw A = grounding screw 2NO/2NC 2NO/2NC 1NO/3NC 1NO/3NC 4NC Sensing and Internet of Things 5 MICRO SWITCH Cable-Pull Safety Switches, CPS Series Conduit Switching Bar Chart Contact Closed | Contact Open Contact Material 1CPSA1 1/2 in NPT 1NO/1NC silver alloy 1CPSA1A 1/2 in NPT 1NO/1NC silver alloy 1CPSA1B 1/2 in NPT 1NO/1NC 1CPSA5 1/2 in NPT 1NO/1NC 1CPSC1 20 mm 1NO/1NC 1CPSC1A 20 mm 1NO/1NC 1CPSC5 20 mm 1NO/1NC 1CPSA2 1/2 in NPT 2NO/2NC silver alloy 1CPSA2A 1/2 in NPT 2NO/2NC silver alloy 1CPSA2B 1/2 in NPT 2NO/2NC 1CPSA6 1/2 in NPT 2NO/2NC 1CPSA6A 1/2 in NPT 2NO/2NC 1CPSA6B 1/2 in NPT 2NO/2NC 1CPSC2 20 mm 2NO/2NC 12,7 [0.5] Left 21-22 Switch 13-14 9,9 [0.39] 9,9 [0.39] 7,9 3,8 3,8 7,9 12,7 [0.31] [0.15] [0.15] [0.31] [0.5] 0 Slackened cable - u gold-plated Pulled cable silver alloy - - u gold-plated Left Switch Right Switch 12,7 [0.5] 21-22 13-14 21-22 13-14 9,9 [0.39] 0 7,9 3,8 3,8 7,9 [0.31] [0.15] [0.15] [0.31] 9,9 [0.39] Pulled cable silver alloy 1CPSC2B 20 mm 2NO/2NC silver alloy 1CPSC6 20 mm 2NO/2NC gold-plated 1CPSC6A 20 mm 2NO/2NC gold-plated 1CPSA3 1/2 in NPT 1NO/3NC silver alloy 1CPSA3A 1/2 in NPT 1NO/3NC silver alloy 1/2 in NPT 1NO/3NC 0 7,9 3,8 3,8 7,9 [0.31] [0.15] [0.15] [0.31] 9,9 [0.39] - - - u u silver alloy Proper cable tension 2NO/2NC 9,9 [0.39] - u gold-plated 20 mm 12,7 [0.5] 21-22 13-14 11-12 21-22 - u gold-plated gold-plated Slackened cable Left Switch Right Switch - silver alloy 12,7 [0.5] - - silver alloy Proper cable tension Notes - u silver alloy 1CPSC2A 1CPSA3A-F01 Pilot Light 120 Vac LED Catalog Listing Pilot Light 24 Vdc LED Table 6. 1CPS With Broken Cable Detection Order Guide - - - u u - - - u - u - silver alloy u 10-pin Brad Harrison connector; actuator to right silver alloy u 10-pin Brad Harrison connector; actuator to left 12,7 [0.5] 1CPSA3A-F02 1/2 in NPT 1NO/3NC 1CPSA3B 1/2 in NPT 1NO/3NC 1CPSA7 1/2 in NPT 1NO/3NC gold-plated - 1CPSC3 20 mm 1NO/3NC silver alloy - 1CPSC3A 20 mm 1NO/3NC silver alloy 1CPSC7 20 mm 1NO/3NC gold-plated - 1CPSA4 1/2 in NPT 4NC silver alloy - 1CPSA4B 1/2 in NPT 4NC 1CPSA8 1/2 in NPT 4NC 1CPSC4 20 mm 1CPSC8 20 mm 6 sensing.honeywell.com 4NC 4NC Slackened cable Left Switch Right Switch 12,7 [0.5] 11-12 21-22 11-12 21-22 9,9 [0.39] Proper cable tension 0 9,9 [0.39] 7,9 3,8 3,8 7,9 [0.31] [0.15] [0.15] [0.31] Slackened cable Proper cable tension silver alloy Pulled cable Pulled cable 12,7 [0.5] silver alloy u - - u u - gold-plated - silver alloy - gold-plated - MICRO SWITCH Cable-Pull Safety Switches, CPS Series 1CPSA1-N Conduit Switching Bar Chart Contact Closed | Contact Open 1/2 in NPT 1NO/1NC 7,9 [0.31] 0 1CPSA1A-N 1/2 in NPT 1NO/1NC 1CPSA1B-N 1/2 in NPT 1NO/1NC 1CPSA2-N 1/2 in NPT 2NO/2NC 1CPSA2B-N 1/2 in NPT 2NO/2NC 9,9 [0.39] silver alloy silver alloy Pulled cable 21-22 13-14 21-22 13-14 0 7,9 [0.31] 9,9 [0.39] Notes - 12,7 [0.5] Left 21-22 Switch 13-14 Left Switch Right Switch Contact Material Pilot Light 120 Vac LED Catalog Listing Pilot Light 24 Vdc LED Table 7. 1CPS Without Broken Cable Detection Order Guide silver alloy - u u silver alloy - - 12,7 [0.5] silver alloy u - silver alloy u - Pulled cable 9,9 [0.39] 1CPSA4B-N 1/2 in NPT 4NC Left Switch Right Switch 11-12 21-22 11-12 21-22 0 7,9 [0.31] 12,7 [0.5] Pulled cable Sensing and Internet of Things 7 MICRO SWITCH Cable-Pull Safety Switches, CPS Series Pilot Light LED Actuation Bar Chart Contact Closed Contact Open Removeable Contact Block Standard Contact Block Switching Catalog Listing Conduit Table 8. 2CPS With Broken Cable Detection and Silver Alloy Contacts Order Guide Notes 2CPSA1A1 1/2 in NPT 2NO/2NC u Both 2CPSA1A1A 1/2 in NPT 2NO/2NC u Both 24 Vdcdc 2CPSA1A1A-FW 1/2 in NPT 2NO/2NC u Both 10-pin Brad 24 Vdc Harrison connector 2CPSA1A1B 1/2 in NPT 2NO/2NC u Both 120 Vac 2CPSA1A2 1/2 in NPT 2NO/2NC u Left only 2CPSA1A2A 1/2 in NPT 2NO/2NC u Left only 24 Vdc 2CPSA1A2A-FW 1/2 in NPT 2NO/2NC u Left only 10-pin Brad 24 Vdc Harrison connector 2CPSA1A2B 1/2 in NPT 2NO/2NC u Left only 120 Vac 2CPSA1A3 1/2 in NPT 2NO/2NC u Right only 2CPSA1A3A 1/2 in NPT 2NO/2NC u Right only 24 Vdc u 10-pin Brad Right only 24 Vdc Harrison connector u Right only 2CPSA1A3A-FW 1/2 in NPT 2NO/2NC 2CPSA1A3B 1/2 in NPT 2NO/2NC 2CPSA2A1 1/2 in NPT 2NO/2NC 2CPSA2A1A 1/2 in NPT 2NO/2NC 2CPSA2A1B 1/2 in NPT 2NO/2NC 2CPSA2A2 Left Switch Right Switch 12,7 [0.5] 21-22 13-14 21-22 13-14 9,9 [0.39] 0 7,9 3,8 3,8 7,9 [0.31] [0.15] [0.15] [0.31] 9,9 [0.39] 12,7 [0.5] 120 Vac u Both u Both 24 Vdc u Both 120 Vac 1/2 in NPT 2NO/2NC u Left only 2CPSA2A2A 1/2 in NPT 2NO/2NC u Left only 24 Vdc 2CPSA2A2B 1/2 in NPT 2NO/2NC u Left only 120 Vac 2CPSA2A3 1/2 in NPT 2NO/2NC u Right only 2CPSA2A3A 1/2 in NPT 2NO/2NC u Right only 24 Vdc 2CPSA2A3B 1/2 in NPT 2NO/2NC u Right only 2CPSC1A1 20 mm 2NO/2NC u Both 2CPSC1A1A 20 mm 2NO/2NC u Both 2CPSC1A2 20 mm 2NO/2NC u Left only 2CPSC1A2A 20 mm 2NO/2NC u Left only 2CPSC1A3 20 mm 2NO/2NC u Right only 2CPSC1A3A 20 mm 2NO/2NC u 2CPSC2A1A 20 mm 2NO/2NC 8 sensing.honeywell.com Slackened cable Proper cable tension Pulled cable 120 Vac 24 Vdc 24 Vdc Right only 24 Vdc u Both 24 Vdc MICRO SWITCH Cable-Pull Safety Switches, CPS Series Pilot Light LED Actuation Bar Chart Contact Closed Contact Open Removeable Contact Block Standard Contact Block Switching Catalog Listing Conduit Table 8. 2CPS With Broken Cable Detection and Silver Alloy Contacts Order Guide, continued Notes 2CPSA1B1 1/2 in NPT 1NO/3NC u Both 2CPSA1B1A 1/2 in NPT 1NO/3NC u Both 24 Vdc 2CPSA1B1A-F01 1/2 in NPT 1NO/3NC u Both 10-pin Brad 24 Vdc Harrison connector 2CPSA1B1B 1/2 in NPT 1NO/3NC u Both 120 Vac 2CPSA1B2 1/2 in NPT 1NO/3NC u Left only 120 Vac 2CPSA1B2A 1/2 in NPT 1NO/3NC u Left only 24 Vdc u Left only 10-pin Brad 24 Vdc Harrison connector u Left only 120 Vac u Right only u Right only 24 Vdc 2CPSA1B3A-F01 1/2 in NPT 1NO/3NC u 10-pin Brad Right only 24 Vdc Harrison connector 2CPSA1B3B 1/2 in NPT 1NO/3NC u Right only 2CPSA2B1 1/2 in NPT 1NO/3NC u Both 2CPSA2B1A 1/2 in NPT 1NO/3NC u Both 24 Vdc 2CPSA2B1B 1/2 in NPT 1NO/3NC u Both 120 Vac Both 24 Vdc 2CPSA1B2A-F01 1/2 in NPT 1NO/3NC 2CPSA1B2B 1/2 in NPT 1NO/3NC 2CPSA1B3 1/2 in NPT 1NO/3NC 2CPSA1B3A 1/2 in NPT 1NO/3NC 2CPSC1D1A 20 mm 4NC Left Switch Right Switch 12,7 [0.5] 21-22 13-14 11-12 21-22 9,9 [0.39] 7,9 3,8 3,8 7,9 [0.31] [0.15] [0.15] [0.31] Slackened cable Left Switch Right Switch 12,7 [0.5] 11-12 21-22 11-12 21-22 0 Proper cable tension 9,9 [0.39] 12,7 [0.5] Pulled cable 120 Vac 0 9,9 [0.39] 7,9 3,8 3,8 7,9 12,7 [0.31] [0.15] [0.15] [0.31] [0.5] 9,9 [0.39] Slackened cable u Proper cable tension Pulled cable Sensing and Internet of Things 9 MICRO SWITCH Cable-Pull Safety Switches, CPS Series 2CPSA1A4 1/2 in NPT 2NO/2NC 2CPSA1A4B 1/2 in NPT 2NO/2NC 2CPSA1A5B 1/2 in NPT 2NO/2NC 2CPSA1A6B 1/2 in NPT 2NO/2NC 2CPSA2A4A 1/2 in NPT 2NO/2NC 2CPSA2A4B 1/2 in NPT 2NO/2NC 2CPSC1A4-F02 20 mm 10 sensing.honeywell.com 2NO/2NC Left Switch Right Switch 21-22 13-14 21-22 13-14 0 7,9 [0.31] 9,9 [0.39] Pulled cable 12,7 [0.5] Pilot Light LED Actuation Bar Chart Contact Closed Contact Open Removeable Contact Block Standard Contact Block Switching Catalog Listing Conduit Table 9. 2CPS Without Broken Cable Detection and With Silver Alloy Contacts Order Guide u Both u Both 120 Vac u Left only 120 Vac u Right only 120 Vac u u Both 24 Vdc u Both 120 Vac Both Notes No turnbuckles included MICRO SWITCH Cable-Pull Safety Switches, CPS Series Figure 4. 1CPS Dimensional Drawing 172,72 mm [6.8 in] 6,6 mm [0.26 in] 88,9 mm [3.5 in] 152,4 mm [6.0 in] Indicator version only 81,28 mm [3.2 in] 33,02 mm [1.3 in] 12,7 mm [0.5 in] 99,1 mm 76,2 mm [3.9 in] [3.0 in] 53,34 mm [2.1 in] 4 X O 7,37 mm [4 X O 0.29 in] 117,25 mm [4.616 in] approx. at full travel 56,8 mm [2.24 in] 65,2 mm [2.57 in] 50,82 mm [2.001 in] 3X 25,4 mm [3X 1.0 in] 25,4 mm [1.0 in] 3X conduit thread 4X mounting pad 172,72 mm [6.8 in] 6,6 mm [0.26 in] 152,4 mm [6.0 in] Indicator version only 88,9 mm [3.5 in] 99,1 mm [3.9 in] 76,2 mm [3.0 in] 12,7 mm [0.5 in] 4 X O 7,37 mm [4 X O 0.29 in] Yellow e-stop background field 53,34 mm [2.1 in] 104,6 mm [4.12 in] approx. at full travel Red emergency stop button 50,82 mm [2.001 in] 3X 25,4 mm [3X 1.0 in] 25,4 mm [1.0 in] Sensing and Internet of Things 11 MICRO SWITCH Cable-Pull Safety Switches, CPS Series Figure 5. 2CPS Dimensional Drawing 40,39 mm [1.59 in] 66,8 mm [2.63 in] 84,07 mm [3.31 in] 92,89 mm [3.66 in] 323,85 mm [12.75 in] approx. at actuation 152,4 mm [6.0 in] Manual reset button 19,05 mm [0.75 in] 52,07 mm [2.05 in] 12,7 mm [0.5 in] 40,39 mm [1.59 in] 2X 7,11 mm [0.28 in] 18,29 mm [0.72 in] 34,93 mm [1.375 in] 152,4 mm [6 in] 2X 7,11 mm [0.28 in] 2X 9,14 mm [0.36 in] 81,3 mm [3.2 in] 2X mounting pad 104,78 mm [4.125 in] Indicator version only 2X 31,75 mm [1.25 in] 12,7 mm [0.5 in] 57,15 mm [2.25 in] 139,7 mm [5.50 in] 3X conduit thread 2X mounting pad 2X 6,9 mm [0.27 in] 3X 12,46 mm [0.845 in] 12 sensing.honeywell.com MICRO SWITCH Cable-Pull Safety Switches, CPS Series Figure 6. 1CPS Application Information Figure 7. 2CPS Application Information Sensing and Internet of Things 13 MICRO SWITCH Cable-Pull Safety Switches, CPS Series Table 10. Accessories/Hardware Packets Catalog Listing Accessory CLSZC1 Cable - 7,6 m [25 ft] length CLSZC2 Cable - 15,2 m [50 ft] length CLSZC3 Cable - 30,5 m [100 ft] length CLSZC4 Cable - 45,7 m [150 ft] length CLSZC5 Cable - 61 m [200 ft] length CLSZC7 Cable - 76,2 m [250 ft] length CLSZTC (2) Thimbles (2) Low-profile duplex cable clamps CLSZ1S (1) Draw-bar endspring CPSZ1E M6 x 1 x 60 mm eyebolt CPSZ1S (1) Draw-bar endspring CPSZK1 (1) J-hook turnbuckle with lock nuts (2) Thimbles (2) Low-profile duplex cable clamps (16) Sets of cable supports [(16) 1/4-20 eye bolts, (32) 1/4-20 nuts, (32) flat washers, (16) lock washers] CPSZK2 European hardware packet (1) J-hook turnbuckle with lock nuts (2) Thimbles (2) Stainless steel cable clamps (16) Sets of cable supports [(16) 1/4-20 eye bolts, (32) 1/4-20 nuts, (32) flat washers, (16) lock washers] CPSZTB J-hook turnbuckle with lock nuts (included with 2CPS) CPSLED24 Multi-cluster LED accessory - 24 Vdc (conduit mount) CPSLED120 Multi-cluster LED accessory - 120 Vac (conduit mount) CPS-BRACKET Mounting bracket (to be used with 1CPS or 2CPS) Figure 8. CPSLED Dimensional Drawing 14 sensing.honeywell.com Figure 9. CPS-Bracket m WARNING ADDITIONAL MATERIALS The following associated literature is available on the Honeywell web site at sensing.honeywell.com: * * * * * * Product line guide Product part listing/nomenclature tree Product range guide CPS troubleshooting guide Electromechanical safety switch product selection guide Application note: MICRO SWITCH switches in conveyor applications RISK TO LIFE OR PROPERTY Never use this product for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that this product is properly rated and installed for the intended use within the overall system. Failure to comply with these instructions could result in death or serious injury. m WARNING MISUSE OF DOCUMENTATION * * The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. For more information Honeywell Sensing and Internet of Things services its customers through a worldwide network of sales offices and distributors. For application assistance, While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer's sole responsibility to determine the suitability of the product in the application. current specifications, pricing or the Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. nearest Authorized Distributor, visit However, Honeywell assumes no responsibility for its use. sensing.honeywell.com or call: Asia Pacific +65 6355-2828 Europe +44 (0) 1698 481481 USA/Canada +1-800-537-6945 Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 www. honeywell.com 004785-5-EN | 5 | 10/18 (c) 2018 Honeywell International Inc. All rights reserved.