FieldIT Data Sheet SS/268XR_2 2600T Series Pressure Transmitters Model 268DR Differential Models 268PR and 268HR Gauge Models 268VR and 268NR Absolute with remote seal(s) TUV SIL2 certified to IEC 61508/ISA S84.01 - the smart solution in Safety loop application Base accuracy : 0.075% Span limits - 0.2 to 16000kPa; 0.8inH2O to 2320psi - 0.54 to 16000kPa abs; 4mmHg to 2320psia Reliable sensing system coupled with very latest digital technologies Hardware and software redundancy with MTBF of over 100 years Comprehensive sensor choice - optimize in-use total performance and stability 5-year stability Flexible configuration facilities - via hand held terminal or PC configuration platform HART(R) communication - provides integration with HART(R) platforms Broad selection of variants, options fill fluids and wetted materials - allows total flexibility maximizing cost-effective aspect, also providing applications with critical process media at extended temperature range PED compliance to sound engineering practice (SEP) ABB 2600T Series Engineered solutions for all applications 2600T Pressure Transmitters Model 268DR, 268PR, 268HR, 268VR, 268NR SS/268XR_2 General Description Model Models detailed in this data sheet apply for those transmitters which include one or two remote seal(s) connected via a capillary to the transmitter sensor. Depending on the selected ordering code the following models are available: a) model 268DR which allows a differential measurement using either two remote seals of same type and size or one remote seal (on positive or negative side) and a standard threaded connection 1/4in NPT on flange or 1/2in NPT through adapter, for the wet or dry leg on the side opposite to seal. b) models 268PR or 268VR allowing gauge or absolute measurement respetively with the reference side at atmosphere or at vacuum. The other side which can be the positive or negative (high or low pressure side) features the required remote seal. Seal type Size Mnemonic S264W Wafer 1 1/2in / DN40 2in / DN50 3in / DN80 S264C Chemical tee flanged 3in P3 Flanged flush diaphragm 2in / DN50 3-4in / DN80-100 P2 P3 Flanged extended diaphragm 2in / DN50 3in / DN80 4in / DN100 E2 E3 P3 S264U Union 1 1/2in P1.5 S264T Threaded off-line 2 1/2in T2.5 S264M Flanged off-line 2 1/2in T2.5 The following table list the types of standard seal which can be combined with 268xR transmitters (the mnemonic is used as reference in the compatibility table of page 3). S264S Union nut Triclamp Cherry Burrel Sanitary, Aseptic 2in / F50 3in / F80 4in S2 S3 S3 Refer to seal data sheet for all data and details relevant to seal element. S264B Button 1in B1 S264P Urea service flanged 1 1/2in 2 1/2in Model 268HR or 268NR have the remote seal on the positive side and the user can select the suitable code for having the reference at armospheric or vacuum pressure respectively for gauge or absolute measure. S264F P1.5 P2 P3 U1.5 U2.5 All following specification data apply for identical characteristics of the two sides when the transmitter is differential with two seals. Functional Specifications Range and span limits - models 268DR/268PR/268VR Sensor Code B E F G H M P Q S 2 Upper Range Limit (URL) 268DR differential measure Lower Range Limit (LRL) 268PR gauge measure 268VR absolute measure Minimum span 4kPa 40mbar 16inH2O 16kPa 160mbar 64inH2O 40kPa 400mbar 160inH2O 65kPa 650mbar 260inH2O 160kPa 1600mbar 642inH2O 600kPa 6bar 87psi 2400kPa 24bar 348psi 8000kPa 80bar 1160psi -4kPa -40mbar -16inH2O -16kPa -160mbar -64inH2O -40kPa -400mbar -160inH2O -65kPa -650mbar -260inH2O -160kPa -1600mbar -642inH2O -600kPa -6bar -87psi -2400kPa -24bar -348psi -8000kPa -80bar -1160psi -16kPa -160mbar -64inH2O -40kPa -400mbar -160inH2O -65kPa -650mbar -260inH2O 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.2kPa 2mbar 0.8inH2O 0.54kPa 5.4mbar 2.16inH2O 0.67kPa 6.7mbar 2.67inH2O 1.1kPa 11mbar 4.35inH2O 2.67kPa 26.7mbar 10.7inH2O 10kPa 0.1bar 1.45psi 40kPa 0.4bar 5.8psi 134kPa 1.34bar 19.4psi 16000kPa 160bar 2320psi -16000kPa -160bar -2320psi 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 267kPa 2.67bar 38.7psi 2600T Pressure Transmitters Model 268DR, 268PR, 268HR, 268VR, 268NR SS/268XR_2 Span limits - models 268HR/NR Sensor Code Upper Range Limit (URL) Lower Range Limit (LRL) Minimum Span G 65kPa 650mbar 260inH2O 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 1.1kPa 11mbar 4.35inH2O H 160kPa 1600mbar 642inH2O 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 2.67kPa 26.7mbar 10.7inH2O M 600kPa 6bar 87psi 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 10kPa 0.1bar 1.45psi P 2400kPa 24bar 348psi 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 40kPa 0.4bar 5.8psi Q 8000kPa 80bar 1160psi 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 134kPa 1.34bar 19.4psi S 16000kPa 160bar 2320psi 0.07kPa abs () 0.7mbar abs () 0.5mmHg () 267kPa 2.67bar 38.7psi Maximum span = URL (can be further adjusted up to URL (TD = 0.5) for differential models, within the range limits) IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS. Zero suppression and elevation Zero and span can be adjusted to any value within the range limits detailed in the table as long as: - calibrated span minimum span Damping Selectable time constant : 0, 0.25, 0.5, 1, 2, 4, 8 or 16s. This is in addition to sensor response time Turn on time Operation within specification in less than 5s with minimum damping. Insulation resistance > 100M at 1000VDC (terminals to earth) () Double the value with the inert filling Sensor Code B E F-G H M P Q S Compatibility (allowed seal types with maximum capillary length (m) in brakets) versus measurement configuration Differential gauge and differential absolute (two seals) (one seal) (one seal) P3 (1.5) E3 (1*) T2.5 (1*) S3 (1.5*) P3 (3) E3 (2*), T2.5 (2*), S3 (3*) P2 (3), P3 (6), E2 (2), E3 (4), T2,5 (3) U2.5 (3), S2 (1*), S3 (6) P1.5 (4), P2 (8), P3 (8), E2 (6), E3 (6) T2.5 (6),U2.5 (6), S2 (3), S3 (10) P1.5 (5), P2 (8), P3 (10), E2 (6), E3 (8), T2.5 (6), U2.5 (6), S2 (6), S3 (10) P1.5 (5), P2 (8), P3 (10), E2 (6), E3 (8), T2.5 (6), U2.5 (6), S2 (6), S3 (10) P1.5 (5), P2 (8), P3 (10), E2 (6), E3 (8), T2.5 (6), U2.5 (6), S2 (6), S3 (10) P1.5 (5), P2 (8), P3 (10), T2.5 (6), U2.5 (6) P3 (1) S3 (1) P2 (2), P3 (4), E3 (3), T2,5 (2) U2.5 (3), S3 (4) P1.5 (3), P2 (6), P3 (10), E2 (4), E3 (8) T2.5 (6),U2.5 (6), S2 (2), S3 (10) P1.5 (5), P2 (8), P3 (10), E2 (6), E3 (8), T2.5 (6), U1.5 (5),U2.5 (6), S2 (6), S3 (10) P1.5 (5), P2 (8), P3 (10), E2 (6), E3 (8), T2.5 (6), U1.5 (5), U2.5 (6), S2 (6), S3 (10) P1.5 (5), P2 (8), P3 (10), E2 (6), E3 (8), B1 (3*) T2.5 (6), U1.5 (5), U2.5 (6), S2 (6), S3 (10) P1.5 (5), P2 (8), P3 (10), T2.5 (6), U1.5 (5), U2.5 (6), B1 (3*) P2 (2), P3 (3), E3 (3), T2,5 (2) U2.5 (3), S3 (3) P1.5 (3), P2 (5), P3 (8), E2 (3), E3 (6) T2.5 (5),U2.5 (5), S2 (2), S3 (8) P1.5 (4), P2 (6), P3 (8), E2 (5), E3 (6), T2.5 (5), U1.5 (4),U2.5 (5), S2 (5), S3 (8) P1.5 (4), P2 (6), P3 (8), E2 (5), E3 (6), T2.5 (5), U1.5 (4),U2.5 (5), S2 (5), S3 (8) P1.5 (4), P2 (6), P3 (8), E2 (5), E3 (6), T2.5 (5), U1.5 (4),U2.5 (5), S2 (5), S3 (8) P1.5 (4), P2 (6), P3 (8), T2.5 (5), U1.5 (4),U2.5 (5) The combinations sensor code/seal type marked (*) modify the base accuracy rating and static pressure effect; refer to performance specifications. Although he above table defines capillary length, for some types of seal combined to the sensor, care should be taken of the maximum working pressure of the used seal which can limit the range. Refer to ABB for data related to application of capillary lengths greater than those specified in above table. 3 2600T Pressure Transmitters Model 268DR, 268PR, 268HR, 268VR, 268NR SS/268XR_2 Operative limits Pressure limits Temperature limits C (F) : Refer to seal specification sheet for maximum working pressure related to the used remote seal. Ambient (is the operating temperature) Overpressure limits (without damage to the transmitter) Filling Silicone oil DC 200TM Inert GaldenTM Inert HalocarbonTM Models 268DR/PR/VR Models 268HR/NR Sensors Sensors Sensors B, E F to S G to S -40 and +85 -25 and +85 -40 and +85 (-40 and +185) (-13 and +185) (-40 and +185) -20 and +85 -10 and +85 -20 and +85 (-4 and +185) (+14 and +185) (-4 and +185) -20 and +85 -10 and +85 -20 and +85 (-4 and +185) (+14 and +185) (-4 and +185) Lower ambient limit for LCD indicators: -20C (-4F) Note : For Hazardous Atmosphere applications see the temperature range specified on the certificate/approval relevant to the aimed type of protection Process Lower limit (low pressure side 268DR only) - refer to lower ambient limits; -20C (-4F) for Viton gasket Upper limit (low pressure side 268DR only) - Silicone oil: 121C (250F) (1) - Inert fluid: 100C (212F) (2) (1) 100C (212F) for application below atmospheric pressure (2) 65C (150F) for application below atmospheric pressure The following table show characteristics of capillary/seal fill fluids when used in transmitters with remote seal. OPERATING CONDITIONS Tmax Pmin Tmax @ Pabs>of mbar abs @ P min (psia) Silicone oil-DC200TM 200 (390) 0.7 160 (General purpose) @ 35mbar (0.01) (320) Silicone oil-AN140TM 380 (716) 0.7 300 (High temperature) @ 1bar (0.01) (572) Silicone Polymer-SylthermXLTTM 100 (212) 2 20 (Low temperature) @ 110mbar (0.03) (68) Vegetable oil-Neobee M-20TM 200 (390) 130 150 (Food-Sanitary) FDA @ 1bar (1.9) (300) Glycerin Water (70%) 93 (200) 1000 93 (Food-Sanitary) FDA @ 1bar (14.5) (200) Mineral oil-MARCOL 82TM 200 (390) 33 40 (Food-Sanitary) FDA @ 200mbar (0.5) (104) Inert - GaldenTM 160 (320) 0.7 65 (Oxygen Service) @ 1bar (0.01) (150) Inert - HalocarbonTM4.2 180 (356) 4 70 (Oxygen Service) @ 400mbar (0.06) (158) ABB fill 300 (572) 0.7 160 (Paints and specials) @ 400mbar (0.01) (320) Tmin -40 (-40) -5 (+23) -100 (-148) -18 (0) -7 (+20) -40 (-40) -18 (0) -20 (-4) -10 (+14) Fills fluids with FDA are defined as food fills and are Generally Recognized As Safe (GRAS) by the US Food and Drug Administration (FDA). Lower limit for Viton gasket -20C (-4F) Storage Lower limit: -50C (-58F); -40C (-40F) for LCD indicators Upper limit: +85C (+185F) 4 - 16MPa, 160bar, 2320psi for models 268DR, 268PR and 268VR (except 7MPa, 70bar, 1015psi for sensor code B) - 21MPa, 210bar, 3045psi for models 264HR and 264NR Static pressure Transmitters for differential pressure model 268DR operates within specifications between the following limits: - 1.3kPa abs,13mbar abs, 0.2psia and 16MPa, 160bar, 2320psi (except 7MPa, 70bar, 1015psi for sensor code B). Upper ambient limit for LCD indicators: +70C (+158F) FILL FLUIDS (APPLICATION) 0.067kPa abs, 0.67mbar abs, 0.01psia (double with inert filling) to transmitter sensor limit or flange rating of seal, whichever is less: - 0.067kPa abs,0.67mbar abs, 0.1psia and 16MPa, 160bar, 2320psi (except 7MPa, 70bar, 1015psi for sensor code B) or flange rating of seal whichever is less, using two remote seals on both transmitter side. 2600T Pressure Transmitters Model 268DR, 268PR, 268HR, 268VR, 268NR Proof pressure SS/268XR_2 Wet and dust-laden atmospheres The transmitter can be exposed without leaking to line pressure of up to - 28MPa, 280bar, 4000psi for model 268DR The transmitter is dust and sand tight and protected against immersion effects as defined by EN 60529 (1989) to IP 67 (IP 68 on request) or by NEMA to 4X or by JIS to C0920. - 40MPa, 400bar, 5900 psi for models 268HR/NR or two times the flange rating of seal, whichever is less Meet ANSI/ISA-S 82.03 hydrostatic test requirements and SAMA PMC 27.1. Environmental limits Electromagnetic compatibility (EMC) Comply with EN 61000-6-3 for emission and EN 61000-6-2 for immunity requirements and test; Radiated electromagnetic immunity level: (according to IEC 1000-4-3, EN61000-4-3) 30V/m Conducted electromagnetic immunity level : (according to IEC 1000-4-6, EN 61000-4-6) 30V Surge immunity level (with surge protector): (according to IEC 1000-4-5 EN 61000-4-5) 4kV Fast transient (Burst) immunity level: (according to IEC 1000-4-4 EN 61000-4-4) 4kV Hazardous atmospheres With or without output meter - INTRINSIC SAFETY/EUROPE: ATEX/TUV approval II 1 G T50C, EEx ia IIC T5 (-40C Ta +40C) T95C, EEx ia IIC T4 (-40C Ta +85C) - FLAMEPROOF/EUROPE: ATEX/CESI approval II 1/2 GD T85C, EEx d IIC T6 (-40C Ta +75C) - FACTORY MUTUAL: - Explosionproof: Class I, Div. 1, Groups A, B, C, D - Dust ignitionproof : Class II, Div. 1, Groups E, F, G - Suitable for : Class II, Div. 2, Groups F, G; Class III, Div. 1, 2 Pressure equipment directive (PED) Comply with 97/23/EEC following sound engineering practice (SEP). Humidity Relative humidity: up to 100% annual average Condensing, icing: admissible Vibration resistance Accelerations up to 2g at frequency up to 1000Hz (according to IEC 60068-2-26) Shock resistance (according to IEC 60068-2-27) Acceleration: 50g Duration: 11ms 5 2600T Pressure Transmitters Model 268DR, 268PR, 268HR, 268VR, 268NR SS/268XR_2 Optional surge protection Electrical Characteristics and Options HART digital communication and 4 to 20mA output Up to 4kV Power Supply - current 8 s rise time / 20 s delay time to half value The transmitter operates from 10.5 to 42VDC with no load and is protected against reverse polarity connection (additional load allows operations over 42VDC). For EEx ia and other intrinsically safe approval power supply must not exceed 30VDC. Output signal Two-wire 4 to 20mA, user-selectable for linear or square root output, power of 3/2 or 5/2, 5th order or two 2nd order switching point selectable programmable polynomial output. HART(R) communication provides digital process variable (%, mA or engineering units) superimposed on 4 to 20mA signal, with protocol based on Bell 202 FSK standard. Ripple 20mV max on a 250 load as per HART specifications MINIMUM OPERATING VOLTAGES Output current limits (to NAMUR standard) Overload condition no link on output indicator plugs with CoMeter indicator and HART communication with ProMeter output indicator - Lower limit: 3.8mA - Upper limit: 20.5mA Transmitter failure mode (to NAMUR standard) with optional surge protection The output signal can be user-selected to a value of 3.7 or 22mA on gross transmitter failure condition, detected by self-diagnostics. with optional output analog indicator In case of CPU failure the output is driven <3.7mA or >22mA. (volts) 10.7 12.3 12.5 13.3 15.3 Load limitations 4 to 20mA and HART total loop resistance : Supply voltage - min. operating voltage (VDC) --------------------------------------- 22.5 A minimum of 250 is required for HART communication. R(k) = Optional indicators Output meter CoMeter and Prometer LCD : 5-digit (99999 counts) programmable with 7.6mm. high (3in), 7-segment numeric characters plus sign and digital point for digital indication of output value in percentage, current or engineer unit; 10-segment bargraph display (10% per segment) for analog indication of output in percentage; 7-digit with 6mm. high (2.3in), 14-segment alphanumeric characters, for engineer units and configuration display Analog : 36mm (1.4in) scale on 90. 6 - voltage 1.2 s rise time / 50 s delay time to half value 2600T Pressure Transmitters Model 268DR, 268PR, 268HR, 268VR, 268NR Performance specifications Stated at reference condition to IEC 60770 ambient temperature of 20C (68F), relative humidity of 65%, atmospheric pressure of 1013hPa (1013mbar), mounting position with vertical diaphragm and zero based range for transmitter with isolating diaphragms in AISI 316 L ss or Hastelloy and silicone oil fill and HART digital trim values equal to 4-20mA span end points, in linear mode. Unless otherwise specified, errors are quoted as % of span. SS/268XR_2 Operating influences Temperature effects per 20K (36F) ambient temperature change on transmitter sensor between the limits of -20C to +65C (-4 to +150F): Sensor Code Model for TD up to E to S 10:1 (0.04% URL +0.065% span) B 5:1 (0.06% URL +0.10% span) Some performance data are affected by the actual turndown (TD) as ratio between Upper Range Limit (URL) and calibrated span. 268DR 268PR IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS. 268VR E to S 10:1 (0.08% URL +0.13% span) 268HR/NR G to S 10:1 (0.04% URL +0.065% span) Accuracy rating % of calibrated span, including combined effects of terminal based linearity, hysteresis and repeatability. For fieldbus versions SPAN refer to analog input function block outscale range Using remote seal sizes