Multi Function Timer
Leakage current
Timer
Timer
C
CR
R
T
T
Power Power
Short current
(Fig. 4) (Fig. 5)
START
RESET
INHIBIT
< Sensor >
< External sensor power supply >
Rectication
circuit
Transformer
with insulated
Power
++
--
Main circuit
(Fig. 1) ATS11DN/AT11EN
Power
Power
(Fig. 6) (Fig. 7)
START START
RESETINHIBIT
Power Power
(Fig. 2) (Fig. 3)
Setting time, time range, operation mode
Do not change time range or operation mode while time
operating. When changing it, please power off or apply
reset signal.
Input connection
AT11DN/AT11EN Timer is non-transformer type, therefore
please check following for connecting relay contact for
input signal and transistor.
When using the terminal ⑩ as a common terminal of
input signal as (Fig. 2), it may cause damage to the inner
circuit of AT11DN/AT11EN, please use the terminal ② for
common terminal as (Fig. 3).
When using more than one timer with one contact or
transistor input, the short current is owed when it is
connected as (Fig. 4). Please connect the power phase
correctly as (Fig. 5) correctly.
INHIBIT, START, RESET signal applied by short input
terminal ②-⑤, ②-⑥ or ②-⑦.
It may cause internal circuit damaged by wrong
connection.
If using power line with another high voltage line or
energy line at the same conduit, it may cause inductive
voltage. Therefore please use separated conduit for
power line.
When input(INHIBIT, START, RESET) wire is long, please
use shield wire and it should be short.
Common
For DC power supply type, be sure to check the polarity
of terminals.
In case of 12VDC, 24VAC/DC model, isolated and limited
voltage/current or Class 2 source should be provided for
power supply.
When supply the power to the timer, connection shown in
(Fig. 6) might cause malfunction due to leakage current
through R and C. Please connect R and C as shown in
(Fig. 7) to prevent malfunction.
It might cause malfunction if changing the setting
time, time range or operation mode during operating
unit. Please change the the setting time, time range or
operation mode after cut the power off.
Do not use this unit at below places.
Place where there are severe vibration or impact.
Place where strong alkalis or acids are used.
Place where there are direct rays of the sun
Place where strong magnetic eld or electric noise are
generated.
Installation environment
It shall be used indoor
Altitude Max. 2000m
Pollution Degree 2
Installation Category II
RESET INHIBIT