Data sheet ConnectPower CP-BBU 115-230VAC / 12VDC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com The UPS control unit together with the associated battery module and the power supply unit form a complete DC UPS system. In normal operation, the input voltage from the UPS control unit is connected directly to the load. In the event of a mains failure (drop of the DC input voltage) the system switches instantly to battery operation. Once the mains supply has been restored, the system switches back to normal operation and the battery is fully recharged by the integrated charger. Three relay outputs, as well as three additional active transistor outputs and a control input to lock battery operation, provide full remote control by means of SPS or DCS control. Numerous modes of operation and an easyto-use status display provide rapid fault diagnosis and optimum customisation to the application. General ordering data Delivery status Available until Type Order No. Version GTIN (EAN) Qty. Alternative product Discontinued 2014-09-30 CP-BBU 115-230VAC / 12VDC 9916280012 UPS control unit, 12 V 4032248217861 1 pc(s). 1370050010 Creation date October 28, 2019 11:40:09 PM CET Catalogue status 25.10.2019 / We reserve the right to make technical changes. 1 Data sheet ConnectPower CP-BBU 115-230VAC / 12VDC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights Width Height Depth Weight 72.5 mm 127.5 mm 161 mm 950 g Width (inches) Height (inches) Depth (inches) Net weight 20 to 85% RH without condensation 50 C 85 C -20 C...50 C Humidity at storage temperature Operating temperature, min. Storage temperature, min. Storage temperature 2.854 inch 5.02 inch 6.339 inch 1,142 g Temperatures Humidity at operating temperature Operating temperature, max. Storage temperature, max. Operating temperature 20 to 90% -20 C -20 C -20 C...85 C Input Connection range Input frequency Input voltage (voltage mode input) Surge protection AWG26-12 (0.1-4.0 mm) 50/ 60 Hz 85...265 V AC; 120...300 V DC. typ. 115...230 V AC 10% Varistor Input current Input fuse Inrush Current Limitation Wire connection method 0.8 A @ 115 V AC; 0.5 A @ 230 V AC 2 A time-lag fuse (internal) Thermistor Screw connection Output Battery charging current 3A Connection range AWG26-12 (0.1-4.0 mm) Mains failure bridge-over time for 115 V AC 46 ms Max. residual ripple < 50 mVeff Output power 180 W Output voltage type DC Battery voltage Control at input voltage Mains failure bridge-over time for 230 V AC Output current Output voltage Wire connection method EMC standards Operating temperature Standards 13.65 V 0.2% 226 ms max. 15 A / max. 9.0 A for the power supply unit 12 V Screw connection General data Degree of efficiency at max. load Low Voltage Directive Protection degree Status indication 69% 73/ 23/ EWG IP20 Green LED (full charge): battery voltage > 14.75 V DC, Yellow LED (low battery): battery voltage < 11 Vdc, Yellow LED (charging): BBU is loading battery, Red LED (error): no AC input voltage, Red LED (reversed battery): battery poles are reversed EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 -20 C...50 C DIN EN 50178, DIN EN 60950, IEC950 System data Output current max. 15 A / max. 9.0 A for the power supply unit Creation date October 28, 2019 11:40:09 PM CET Catalogue status 25.10.2019 / We reserve the right to make technical changes. 2 Data sheet ConnectPower CP-BBU 115-230VAC / 12VDC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Insulation coordination Humidity at operating temperature electrical isolation, I/O rail electrical isolation, input-output 20 to 85% RH without condensation 3 kV 3 kV Humidity at storage temperature electrical isolation, input-earth electrical isolation, output-earth 20 to 90% 1.5 kV 0.5 kV Signalling Status indication Green LED (full charge): battery voltage > 14.75 V DC, Yellow LED (low battery): battery voltage < 11 Vdc, Yellow LED (charging): BBU is loading battery, Red LED (error): no AC input voltage, Red LED (reversed battery): battery poles are reversed Approvals Institute (CSA) Certificate No. (CSA) Institute (cULus) Certificate no. (cULus) 200039-1196635 E196651 Ratings IECEx/ATEX/cUL Certificate no. (cULus) E196651 EC002850 27-04-06-92 27-04-06-92 ETIM 7.0 eClass 9.1 UNSPSC Classifications ETIM 6.0 eClass 9.0 eClass 10.0 EC002850 27-04-92-01 30-21-18-01 Approvals Approvals ROHS Conform Downloads Approval/Certificate/Document of Conformity ECC1628_02_09.pdf Creation date October 28, 2019 11:40:09 PM CET Catalogue status 25.10.2019 / We reserve the right to make technical changes. 3 Data sheet ConnectPower CP-BBU 115-230VAC / 12VDC Drawings Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Electric symbol Creation date October 28, 2019 11:40:09 PM CET Catalogue status 25.10.2019 / We reserve the right to make technical changes. 4