Series AM50HB-UZ
50 Watt | Half Brick DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 054e R3.A 1 of 5 North America only
FEATURES:
Models
Single output
Model Input Voltage (V) Output Voltage
(V)
Output Current
max (A) Input Filter
AM50HB-2403S-UZ 18-36 3.3 10 type
AM50HB-2405S-UZ 18-36 5 10 type
AM50HB-2412S-UZ 18-36 12 4.2 L type
AM50HB-2415S-UZ 18-36 15 3.2 L type
AM50HB-2424S-UZ 18-36 24 2.1 L type
AM50HB-2428S-UZ 18-36 28 1.8 L type
AM50HB-2448S-UZ 18-36 48 1.1 L type
AM50HB-4803S-UZ 36-72 3.3 10 type
AM50HB-4805S-UZ 36-72 5 10 type
AM50HB-4812S-UZ 36-72 12 4.2 L type
AM50HB-4815S-UZ 36-72 15 3.2 L type
AM50HB-4824S-UZ 36-72 24 2.1 L type
AM50HB-4828S-UZ 36-72 28 1.8 L type
AM50HB-4848S-UZ 36-72 48 1.1 L type
AM50HB-11005S-UZ 66-160 5 10 type
AM50HB-11012S-UZ 66-160 12 4.2 L type
AM50HB-11015S-UZ 66-160 15 3.2 L type
AM50HB-11024S-UZ 66-160 24 2.1 L type
AM50HB-11048S-UZ 66-160 48 1.1 L type
NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Input Specifications
Parameters Nominal Typical Maximum Units
Voltage range
24
48
110
18-36
36-72
66-160
VDC
Remote Control CNTRL open
CNTRL connect to -Vin
On
Off -0.7 ~ 0.4 V
Turn on time 10 ms
Start-up Delay Time 150 ms
Isolation Specifications
Parameters Conditions Typical Maximum Units
Tested I/O voltage 1 Min 1500 VDC
Tested Input / Case voltage 1 Min 500 VDC
Tested Output / Case voltage 1 Min 500 VDC
Output Specifications
Parameters Conditions Typical Maximum Units
Set point accuracy ±1 %
Trim range ±10 %
Dynamic Response 200µs setting time 50-75% & 50-25% load 3% of Vout Pk deviation
Short Circuit protection Continuous
RoHS compliant
Regulated output
Wide 2:1 Input range High efficiency
Very low ripple and noise Operating temperature range: -40 to +85ºC
On/Off Control and Trim Function 1500VDC I/O Isolation
Series AM50HB-UZ
50 Watt | Half Brick DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 054e R3.A 2 of 5 North America only
Output Specifications (continued)
Parameters Conditions Typical Maximum Units
Short Circuit restart Auto recovery
Over Temperature Protection >105 110 115 oC
Total remote sense compensation 0.5 V
Line voltage regulation ±0.2 % of Vin
Load voltage regulation ±0.5 %
Temperature coefficient ±0.02 %/oC
Ripple & Noise 20MHz Bandwidth 1 % of Vout
General Specifications
Parameters Conditions Typical Maximum Units
Switching frequency 100% load 330 KHz
Efficiency At full load 87-90 %
Pin Solder Temperature Wave solder <10s 250 oC
Hand Soldering time Iron Temperature: 425 oC 5 sec
Operating temperature -40 to +85 oC
Storage temperature -55 to +125 oC
Max Case temperature 100 oC
Cooling See derating graph
Humidity 10 to 90 %
Weight Without Heatsink 75 g
Dimensions (L x W x H) 2.28 x 2.40 x 0.50 inches 57.9 x 61.0 x 12.7 mm
MTBF >1,500,000 hrs (Bellcore TR332, t=+25oC)
Safety Specifications
Standards
Safety Meets EN60950
Pin Out Specifications Dimensions
Pin Single
1 -V Input
2 Case
3 On/Off Control
4 +V Input
5 +V Output
6 +Sense
7 Trim
8 -Sense
9 -V Output
10 Omitted
Series AM50HB-UZ
50 Watt | Half Brick DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 054e R3.A 3 of 5 North America only
Derating:
Typical Application:
Aimtec’s half brick models can operate independently. However, to enhance their performance and to ensure precision of
the output signal parameters the following connections are recommended:
Output Ripple and Noise Measurement test setup:
Series AM50HB-UZ
50 Watt | Half Brick DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 054e R3.A 4 of 5 North America only
Please refer to our Application note: Ripple and Noise Measurement of Brick & POL DC-DC Converters.
ON/OFF Control:
The converter output can be disabled by moving SW to position “a”
connected to –Vin with voltage level between -0.7 and 0.4V.
When SW is open in position “b”, the converter is ON and operates
normally.
The SW can be replaced by a NPN transistor with connection as follows:
Output Voltage Trim connection:
The output voltage can be adjusted by connecting trim resistors as shown.
Series AM50HB-UZ
50 Watt | Half Brick DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC
(924 6832)
F 054e R3.A 5 of 5 North America only
The values can be determined according to the following formulas where Δ% is the desirable voltage adjustment in percentage and Vo is
the Nominal value of the Output Voltage:
The calculated Resistor values are in K.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. Aimtec may not have conducted destructive testing or chemical analysis
on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be
available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such
applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
Vo(100+%) - (100+2%)
1.225% % K Rup =
100 – 2
% K Rdown =