7.5x
Control/Power Cables
Chainflex®CF6
PVC Standard Energy Chain®cable, shielded1), oil-proof,
flame-retardant
Price Index
Construction
Conductors: Finely stranded bundled bare copper wires. Designed in accordance with VDE 0295, Class 5.
Conductor insulation: Mechanically high-quality, PVC-insulating compound.
Conductor twisting: Number of conductors < 12 Conductors concentrically layered with short pitch. Number of
conductors ≥12 Conductors layered in braids around a polymer, high-tensile-strength core; short pitches matched
in the direction of the pitch for extremely low torsion.
Conductor colors: Black with white numbers, one conductor green-yellow 20-16 AWG; DIN 47100 24 AWG
Shield: 1) High flexural strength copper shield. Coverage: approx. 70% linear, approx. 90% optical
Outer jacket: PVC-based, low-adhesion blend, adapted to the requirements of the Energy Chain®. Oil-resistant in
accordance with CSA and VDE. Color: green (RAL 6005).
Intermediate jacket: PVC-based, low-adhesion blend, adapted to the requirements of the Energy Chain®.
Technical Data
Minimum bending radius for flexible use: 7.5 x outer cable diameter
Permissible temperature range for continuous flexing: +23°F to +158°F (-5°C to +70°C)
UL/CSA voltage: 300V 24-16 AWG, 600V 14 AWG, VDE voltage: 300/500V
Regulations: UL AWM: 2464 80°C 20-16 AWG; 2570 80°C 14 AWG, CSA AWM: 80°C l/ll A/B FT1 Oil Resistant,
CE: CEI 20-20, VDE: 0245
CF6
Internet: http://www.igus.com
email: webmaster@igus.com
QuickSpec: http://www.igus.com/qs/chainflex.asp
10.40
Part No. AWG No. of Conductors Outer Diameter Copper Index Weight
and Rated Cross- (approx)
Section in mm2in. (mm) lbs/mft (kg/km) lbs/mft (kg/km)
CF6-02-04 24 4 x 0.25 .28 (7) 19.0 (28) 37.4 (55)
CF6-02-24 24 24 x 0.25 .53 (13.5) 68.0 (100) 170.0 (250)
CF6-05-05 20 5 x 0.5 .35 (9) 32.6 (48) 77.5 (114)
CF6-05-07 20 7 x 0.5 .43 (11) 42.8 (63) 96.6 (142)
CF6-05-09 20 9 x 0.5 .49 (12.5) 52.4 (77) 123.8 (182)
CF6-05-12 20 12 x 0.5 .51 (13) 63.2 (93) 160.5 (206)
CF6-05-18 20 18 x 0.5 .59 (15) 81.6 (120) 163.2 (276)
CF6-05-24** 20 24 x 0.5 .67 (17) 129.2 (190) 275.4 (405)
CF6-07-03 18 3 x 0.75 .33 (8.5) 35.4 (52) 74.8 (110)
CF6-07-04 18 4 x 0.75 .35 (9) 36.7 (54) 81.6 (120)
CF6-07-05 18 5 x 0.75 .39 (10) 49.6 (73) 102.0 (150)
CF6-07-07 18 7 x 0.75 .47 (12) 63.2 (93) 129.2 (190)
CF6-07-12 18 12 x 0.75 .55 (14) 93.8 (138) 179.5 (264)
CF6-07-18 18 18 x 0.75 .69 (17.5) 138.7 (204) 278.8 (410)
CF6-07-24** 18 24 x 0.75 .71 (18) 170.0 (250) 316.9 (466)
CF6-10-03 17 3 x 1 .33 (8.5) 41.5 (61) 70.0 (103)
CF6-10-04 17 4 x 1 .33 (8.5) 51.0 (75) 78.2 (115)
CF6-10-05 17 5 x 1 .43 (11) 59.2 (87) 115.6 (170)
CF6-10-07 17 7 x 1 .51 (13) 76.8 (113) 147.6 (217)
CF6-10-12 17 12 x 1 .59 (15) 116.3 (171) 212.8 (313)
CF6-10-18 17 18 x 1 .73 (18.5) 177.5 (261) 319.6 (470)
CF6-10-24** 17 24 x 1 .83 (21) 208.8 (307) 399.8 (588)
CF6-15-03 16 3 x 1.5 .39 (10) 55.1 (81) 105.4 (155)
CF6-15-04 16 4 x 1.5 .41 (10.5) 57.8 (85) 115.6 (170)
CF6-15-05 16 5 x 1.5 .43 (11) 72.1 (106) 129.2 (190)
CF6-15-07 16 7 x 1.5 .55 (14) 104.0 (153) 183.6 (270)
CF6-15-12 16 12 x 1.5 .71 (18) 157.8 (232) 279.5 (411)
CF6-15-18 16 18 x 1.5 .87 (22) 249.6 (367) 433.2 (637)
CF6-15-25 16 25 x 1.5 .96 (24.5) 334.6 (492) 556.9 (819)
CF6-25-04 14 4 x 2.5 .49 (12.5) 91.8 (135) 187.0 (275)
The Chainflex®types marked with ** are cables based on 4-conductor bundles. Due to their excellent electrical properties (star-quad with particularly low crosstalk), these cables can
be used in virtually all applications normally requiring twisted-pair cables.
1) The shield in the Chainflex®Cables is slowly being changed from copper to tinned copper. As the stock levels of the copper shielded cables are depleted, they will be
replaced with the tinned copper shield. Please be aware that we cannot predict the order in which the shielding will be replaced. This change is an upgrade in the quality of
our cables.
NOTE: The mentioned external diameters are maximum values.