3M Round, Shielded/Jacketed, Flat Cable
.050 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series
Physical
Electrical
Note: Unbalanced is measured between ground-signal-ground conductors with shield grounded.
Balanced is measured between signal conductors within a pair, with the shield floating.
Environmental
Jaket Material: Polyvinyl Chloride (PVC)
Color: Black
Primary Material: PVC
Color: Gray
Marking Standard: (UL) CL2 75C 28 AWG or AWM 20267 3M NU AWM IIA/B 80C 300V FT1 EU <50V
Conductors: 28 AWG, 7 x 36 AWG [ 7 x Ø 0.127 ] Tinned Stranded Copper
Shielding: 0.001 [ 0.03 ] Thick Aluminum/Polyester Film Foil and 90% Coverage Tinned Copper Braid
Voltage Rating: USA: N.E.C. 725, CL2 or AWM; 300V Canada: 300V EU: <50V
Insulation Resistance: > 1 × 1010 Ω/10 ft. [ 3m ]
Unbalanced Balanced
Characteristic Impedance: 62 Ω 106 Ω
Capacitance: 27.7 pF/ft [ 90.88 pF/m ] 15.2 pF/ft [ 49.9 pF/m ]
Inductance: 0.11 μH/ft [ 0.35 μH/m ] 0.17 μΗ/ft [ 0.57 μΗ/m ]
Propagation Delay: 1.72 ns/ft [ 5.64 ns/m ] 1.62 ns/ft [ 5.31 ns/m ]
Velocity of Propagation: 59% 62%
Temperature Rating: USA: -20° C to +105° C Canada: -20° C to +80° C
Flammability Rating: USA: VW-1 Canada: FT1
TS-0083-18
Sheet 1 of 2
Round construction permits easier routing
28 AWG wire on .050 inch pitch permits mass
termination to broad line of IDC connectors
Continuous split/bond repeat allows for mass
termination on 2.4 inch centers (approximate)
Primary cable is zippable for branching or
discrete terminations
Meets external wiring requirements of National
Electrical Code, Article 725 (CL2)
UL listed for USA and Canadian markets
Dual shielding provides 35 db average shielding
effectiveness
RoHS* Compliant
Date Modified: April 13, 2007
UL File No.: E118773, Power Limited Circuit Cable: CL2 (or AWM Style 20267)
*"RoHS Compliant 2005/95/EC" means that the product or part ("Product") does not contain any of the substances in excess of the maximum concentration
values in EU Directive 2002/95/EC, as amended by Commission Decision 2005/618/EC, unless the substance is in an application that is exempt under EU
RoHS. This information represents 3M's knowledge and belief, which may be based in whole or in part on information provided by third party suppliers to 3M.
In the event any product is proven not to conform with 3M’s Regulatory Information Appendix, then 3M’s entire liability and Buyer’s exclusive
will be in accordance with the Warranty stated below.
3
Interconnect Solutions
http://www.3M.com/interconnects/
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
3M Round, Shielded/Jacketed, Flat Cable
.050 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series
Number of
Conductors
3M Part Number Diameter A Dimension B Ref
(See Note 2)
09 3659/09 0.27 [ 6.9 ] 0.40 [ 10.2 ]
10 3659/10 0.27 [ 6.9 ] 0.45 [ 11.4 ]
14 3659/14 0.31 [ 7.9 ] 0.65 [ 16.5 ]
15 3659/15 0.31 [ 7.9 ] 0.70 [ 17.8 ]
16 3659/16 0.31 [ 7.9 ] 0.75 [ 19.1 ]
20 3659/20 0.34 [ 8.6 ] 0.95 [ 24.1 ]
24 3659/24 0.37 [ 9.4 ] 1.15 [ 29.2 ]
25 3659/25 0.37 [ 9.4 ] 1.20 [ 30.5 ]
26 3659/26 0.37 [ 9.4 ] 1.25 [ 31.8 ]
34 3659/34 0.41 [ 10.4 ] 1.65 [ 41.9 ]
36 3659/36 0.43 [ 10.9 ] 1.75 [ 44.5 ]
37 3659/37 0.43 [ 10.9 ] 1.80 [ 45.7 ]
40 3659/40 0.43 [ 10.9 ] 1.95 [ 49.5 ]
50 3659/50 0.48 [ 12.2 ] 2.45 [ 62.2 ]
60 3659/60 0.51 [ 13.0 ] 2.95 [ 74.9 ]
64 3659/64 0.54 [ 13.7 ] 3.15 [ 80.0 ]
TS-0083-18
Sheet 2 of 2
[mm]
±.010±.1 ±.05
Tolerance Unless Noted
.0 .00 .000
Inch
[ ] Dimensions for
Reference only
Inch
Notes:
1. Red marking on one edge of primary cable designates wire #1.
2. Dimension B pertains to bonded area only.
Ordering Information
B
Bonded
Split
1.0 Ref.
[25]
Aluminum
Polyester
Film Foil
2.4 Ref
[61]
0.050 Typ
[ 1.27 ]
.026 Min [0.66]
PVC Jacket
28 AWG, 7 X 36 AWG [ 7 X Ø 0.127 ]
Tinned Stranded Copper Conductors
PVC Primary Insulation
Paper
[ Mfgr Option ] Braid
R
Ø
A
Note: Contact 3M for availability of custom roll lengths.
Note: Contact 3M for availability of additional conductor counts.
3659 / XX XX X00 XX
Blank = Standard
SF = Splice Free
Length of Roll in Feet
100 = 100 ft Standard
300 = 300 ft Standard
Blank = Standard
SO = Continuously Bonded Wire
(No Split)
Number of Conductors
(See Table)
3
Printed in USA.
Minimum 10%
Post-Consumer Fiber
Important Notice
All statements, technical information, and recommendations
related to 3M’s products are based on information believed to be
reliable, but the accuracy or completeness is not guaranteed.
Before using this product, you must evaluate it and determine if it
is suitable for your intended application. You assume all risks and
liability associated with such use. Any statements related to the
product which are not contained in 3M’s current publications, or
any contrary statements contained on your purchase order shall
have no force or effect unless expressly agreed upon, in writing,
by an authorized officer of 3M.
Warranty; Limited Remedy; Limited Liability.
This product will be free from defects in material and
manufacture for a period of one (1) year from the time of
purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING,
BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. If this product is defective within the warranty period
stated above, your exclusive remedy shall be, at 3M’s option, to
replace or repair the 3M product or refund the purchase price of
the 3M product. Except where prohibited by law, 3M will not
be liable for any indirect, special, incidental or consequential
loss or damage arising from this 3M product, regardless of
the legal theory asserted.
3M Electronics
6801 River Place Blvd.
Austin, TX 78726-9000
800/225-5373
www.3M.com/electronics © All rights reserved. 3M 2007