Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1419A Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 For more Information please call 1-800-Belden1 General Description: 24 AWG stranded (7x32) TC conductors, Datalene(R) insulation, twisted pairs, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 2 24 7x32 TC - Tinned Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Trade Name Insulation Material Datalene(R) Wall Thickness (mm) FPE - Foam Polyethylene 0.330 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 7x32 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.889 Overall Cable Overall Nominal Diameter: 6.299 mm Pair Pair Color Code Chart: Number Color 1 White/Blue & Blue/White 2 White/Orange & Orange/White Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +80C Non-UL Temperature Rating: 80C (UL AWM Style 2919) Bulk Cable Weight: 40.181 Kg/Km Max. Recommended Pulling Tension: 97.860 N Min. Bend Radius/Minor Axis: 63.500 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1419A Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 NEC/(UL) Specification: CM CEC/C(UL) Specification: CM AWM Specification: UL Style 2919 (30 V 80C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT1 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 100 Nom. Inductance: Inductance (H/m) 0.689 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 42.653 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 72.182 Nominal Velocity of Propagation: VP (%) 78 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 78.744 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 49.5431 Max. Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 2919); 300 V RMS Max. Recommended Current: Current 1.8 Amps per conductor @ 25C Notes (Overall) Notes: Datalene(R) insulation features include low dielectric constant and a dissipation factor for high-speed, low distortion data Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1419A Multi-Conductor - Low Capacitance Computer Cable for EIA RS-232/422 Notes: Datalene(R) insulation features include low dielectric constant and a dissipation factor for high-speed, low distortion data handling. Physical properties include good crush resistance and light weight. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 1419A 0601000 305 MT 13.608 KG CHROME C 2 PR #24 FHDPE FS PVC 1419A 06010000 3,048 MT 140.614 KG CHROME CY 2 PR #24 FHDPE FS PVC 1419A 060500 152 MT 6.804 KG CHROME C 2 PR #24 FHDPE FS PVC Notes: C = CRATE REEL PUT-UP. Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'. Revision Number: 2 Revision Date: 08-14-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013