EMC filters 1-line filters Feedthrough filters Rated current 16 to 500 A Series/Type: B85321 The following products presented in this data sheet are being withdrawn. Ordering Code B85321A2502A160 B85321A2502B160 B85321A4304A750 B85321A4405B201 B85321A4405B301 B85321A4502C160 B85321A4504A750 B85321A4504B301 B85321A6204B250 B85321A6204B630 B85321A6504B301 B85321A6504B630 Substitute Product Date of Withdrawal 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 Deadline Last Orders 2013-11-30 2013-11-30 2013-11-30 2013-11-30 2013-11-30 2013-11-30 2013-11-30 2013-11-30 2013-11-30 2013-11-30 2013-11-30 2013-11-30 Last Shipments 2014-02-28 2014-02-28 2014-02-28 2014-02-28 2014-02-28 2014-02-28 2014-02-28 2014-02-28 2014-02-28 2014-02-28 2014-02-28 2014-02-28 For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at www.epcos.com/sales. 1-line filters Feedthrough components Insertion loss in the frequeny range (Hz) 105 106 107 Page Terminal type Rated capacitance (F) mm Rated voltage (VAC) Dia meter New Type Rated current (A) Overview of available types 5 Feedthrough filters B85321A*+160 16 16 250 2 x 0.0025 6 B85321A*+160 20 25 2 x 0.0025 8 B85321A*A250 B85321A*A750 30 25, 75 250, 500 250 2 x 0.1 ... 2 x 1.0 10 2 x 0.5 ... 2 x 4.7 11 B85321A*A630, 55 A101 ... A501 63 ... 250 500 Legend Terminal type: Tab connectors Axial leads Soldering tags Threaded studs Please read Cautions and warnings and Important notes at the end of this document. 2 01/06 1-line filters Feedthrough components General Feedthrough components from EPCOS are used for EMI suppression of all electrical installations and equipment. This new type series is also outstandingly well suited for telephone exchanges and base stations. Thanks to broadband EMI suppression up to the GHz range, it prevents external in terference pulses being transmitted to the inside of the equipment via the supply network and vice versa. The essential features of this new type series are its modular design and the solder-free contacting technology developed by EPCOS with the aid of mesh contact. Mesh contact technology permits uniform concentric contacting of the MKP capacitor winding and avoids the thermal stress associated with soldering. The result is an even higher insertion loss, a high insulation resistance and a particularly compact case. The modular system used in this new technology for feedthrough capacitors and filters allows the cost-effective implementation of a wide range of standard types. Other capacitance values can also be supplied for special applications upon request. Feedthrough components fitted into a shielding wall. In feedthrough capacitors, the conductor carrying the operating current is connected concentrically to one electrode and is run centrally through the capacitor. The other electrode is contacted con centrically to the capacitor case. Feedthrough capacitors are dimensioned so that they perform well from low frequencies to far above 300 MHz. The capacitor element with low inductance contacted securely on the face side is incorporated in a metal case provided with a screw thread. The feedthrough filters are constructed in a -circuit. They consist of two identical capacitative transverse elements and an inductive longitudinal element. The concentric layout of the compon ents allows high insertion loss values to be attained in a frequency range to above 1 GHz. Safety note Feedthrough components with high capacitances require the implementation of safety measures in line with the applicable specifications! (See also Chapter "Mounting instructions".) Please read Cautions and warnings and Important notes at the end of this document. 3 01/06 1-line filters Feedthrough components Mounting instructions To fully utilize their RF properties, the feedthrough components must be mounted directly into shiel ding walls. The case must be contacted seamlessly (sealed against RF signals) to the shielding wall. This can be best done by screwing it into a threaded hole or bushing so that contact is made via the threads. Alternatively, the feedthrough components may be screwed into feed-through holes on the shielding wall by means of attachment nuts. The contact between case and the shielding wall is then set up via the contact surface of the thread. Caution Contacts with rigid copper busbars are not permitted in view of mechanical stresses of the bushings due to impacts and vibrations. For types with screw connections, the connecting cable must be secured between two nuts to exclude a torque on the feedthrough pins. The use of two flat wrenches is recommended. Recommended tightening torques for feedthrough components (capacitors, filters) Thread dimensions Tightening torque (Nm) Tolerance (Nm) Terminal M2 0.2 +0.05 x M3 0.6 +0.1 x M4 1.2 +0.1 x M5 2 +0.5 x M6 3 +0.5 x M8 5 +0.5 x M10 8 +2 x M12 12 +2 x M16 28 +2 x M18 35 +2 x Thread base attachment M10 x 0.75 3 +0.5 x M12 x 0.75 4 +0.5 x M20 x 1 10 +1 x M24 x 1.5 12 +1.5 x M27 x 1.5 16 +2 x M32 x 1.5 24 +2.5 x Please read Cautions and warnings and Important notes at the end of this document. 4 01/06 1-line filters B85321 Feedthrough filters Rated voltage 250 V AC Rated current 16 to 500 A Rated capacitance 2 x 0.0025 to 2 x 4.7 F Construction Building-block system MKP technology (dry, self-healing) Dielectric: polypropylene, metallized Metal case, polyurethane potting (UL 94 V-0) For central screw fixing Features Compact dimensions Versions with rated voltage 440 V AC available on request High insertion loss Easy to install High contact reliability thanks to central screw fixing Comply with EN 133200 UL approval Applications Broadband interference suppression for AC/DC supply lines, e.g. in shielded rooms telephone exchanges, base stations electrical machines and systems power supplies Terminals Threaded studs Axial leads Soldering tag Tab connector Marking Manufacturer, ordering code, rated capacitance, rated voltage, rated current, climatic category, circuit diagram, date of manufacture (MM.YY), approvals Circuit diagram SSB1274-B Please read Cautions and warnings and Important notes at the end of this document. 5 01/06 1-line filters B85321A*+160 16 mm, 16 A Feedthrough filters Feedthrough filters 16 mm Technical data and measuring conditions Rated voltage VR 250 V AC, 50/60 Hz 600 V DC Rated current IR Referred to 40 C ambient temperature Reduced current values at 400 Hz Capacitance tolerance 20% Climatic category (IEC 60068-1) 40/085/56 (-40 C/+85 C/56 days damp heat test) Screw cap fixing M10 x 0.75 Approvals UL 1283, 250 V Characteristics and ordering codes IR CR VR VR Vtest Terminal Fig. Ordering code Approvals A F V AC V DC V DC 16 2 x 0.0025 250 600 2700 2 x 0.0025 250 600 M2 1 B85321A2502X160 x 2700 Soldering tag 2 B85321A2502Y160 x x 2 x 0.0025 250 600 2700 Leads 2 mm 3 B85321A2502Z160 2 x 0.0025 250 600 2700 Tab connector 6.3 mm B85321A2502W160 x 4 x = approval granted Insertion loss (dB); typical values at 50 CR (F) 10 kHz 2 x 0.0025 - 100 kHz - 1 MHz 10 MHz 100 MHz 1 GHz - 25 > 80 > 80 Dimensional drawings Figure 1, B85321A2502X160 45+2 60+2 80+2 M2 5 M10 x 0.75 Marking o10.5+0.3 o16 1...3 _ 10 4 Please read Cautions and warnings and Important notes at the end of this document. Tightening torque 0.2 +0.05 Nm M10 x 0.75 3 SSB2018-T 6 Thread M2 01/06 +0.5 Nm 1-line filters B85321A*+160 16 mm, 16 A Feedthrough filters Figure 2, B85321A2502Y160 Marking 5 45+2 60+2 80+2 M10 x 0.75 M2 1...3 o10.5+0.3 o16 Soldering tag, size 3 mm _ 10 4 Thread Tightening torque M2 0.2 +0.05 Nm M10 x 0.75 3 SSB2019-2-E +0.5 Nm Figure 3, B85321A2502Z160 M10 x 0.75 o10.5+0.3 o16 o2 1...3 Marking 45+2 60+2 155 _ 3 5 453 SSB2020-5 Tightening torque: 3 +0.5 Nm Figure 4, B85321A2502W160 Tab connector, size 6.3 mm M10 x 0.75 Marking o10.5+0.3 o16 1...3 45+2 62+2 902 Please read Cautions and warnings and Important notes at the end of this document. 13+1 SSB2031-K-E 7 01/06 Tightening torque: 3 +0.5 Nm 1-line filters B85321A*+160 20 mm, 25 A Feedthrough filters Feedthrough filters 20 mm Technical data and measuring conditions Rated voltage VR 250 and 500 V AC, 50/60 Hz 600 and 700 V DC Rated current IR Referred to 40 C ambient temperature Reduced current values at 400 Hz Capacitance tolerance 20% Climatic category (IEC 60068-1) 40/085/56 (-40 C/+85 C/56 days damp heat test) Screw cap fixing M12 x 0.75 Approvals UL 1283, 250 V Characteristics and ordering codes IR CR VR VR Vtest Terminal Figure Ordering code Approvals A F V AC V DC V DC 25 2 x 0.0025 250 600 2700 2 x 0.0025 250 M4 1 B85321A2502A160 x 600 2700 2 B85321A2502B160 x 700 3000 Leads 2 mm 2 x 0.0025 500 B85321A4502C160 x x = approval granted Insertion loss (dB); typical values at 50 CR (F) 10 kHz 2 x 0.0025 - 100 kHz - Please read Cautions and warnings and Important notes at the end of this document. 1 MHz 10 MHz 100 MHz 1 GHz - 25 > 80 > 80 8 01/06 1-line filters B85321A*+160 20 mm, 25 A Feedthrough filters Dimensional drawings Figure 1, B85321A2502A160 M4 5 45+2 60+2 93+2 M12 x 0.75 Marking o12.5+0.3 o20 1...3 17 _ 2 SSB2022-L Thread Tightening torque M4 1.2 +0.1 Nm M12 x 0.75 4.0 +0.5 Nm Figure 2, B85321A2502B160, B85321A4502C160 M12 x 0.75 Marking o12.5+0.3 o20 o2 1...3 45+2 60+2 155 _ 3 5 Please read Cautions and warnings and Important notes at the end of this document. 453 SSB2023-U 9 01/06 Tightening torque: 4 +0.5 Nm 1-line filters B85321A*A250, A750 30 mm, 25 A, 75 A Feedthrough filters Feedthrough filters 30 mm Technical data and measuring conditions Rated voltage VR 250 V AC, 50/60 Hz 500 and 600 V DC Rated current IR Referred to 40 C ambient temperature Reduced current values at 400 Hz Capacitance tolerance 20% Climatic category (IEC 60068-1) 40/085/56 (-40 C/+85 C/56 days damp heat test) Screw cap fixing M20 x 1 Approvals UL 1283, 250 V Characteristics and ordering codes IR CR VR VR Vtest A F V AC V DC V DC 25 2 x 0.1 250 600 2 x 0.5 250 600 2 x 1.0 250 75 Terminal Ordering code Approvals 3000 M6 B85321A2204A250 x 2000 M6 B85321A2105A250 x 500 1700 M6 B85321A2205A250 x 2 x 0.1 250 600 3000 M6 B85321A2204A750 x 2 x 0.5 250 600 2000 M6 B85321A2105A750 - 2 x 1.0 250 500 1700 M6 B85321A2205A750 x x = approval granted Insertion loss (dB); typical values at 50 CR (F) 10 kHz 100 kHz 1 MHz 10 MHz 100 MHz 1 GHz 2 10 25 70 > 100 > 100 2 x 0.5 5 25 45 80 > 100 > 100 2 x 1.0 10 30 60 90 > 100 > 100 2 x 0.1 M6 o30 M6 M20 x 1 Dimensional drawing Marking 5 M6 81+1 130 _ 1 Please read Cautions and warnings and Important notes at the end of this document. Thread SSB2085-J 10 01/06 M20 x 1 Tightening torque 3 +0.5 Nm 10 +1 Nm 1-line filters B85321A*A630, A101 ... A501 55 mm, 63 ... 500 A Feedthrough filters Feedthrough filters 55 mm Technical data and measuring conditions Rated voltage VR 250 V AC, 50/60 Hz 350 and 600 V DC Rated current IR Referred to 40 C ambient temperature Reduced current values at 400 Hz Capacitance tolerance 20% Climatic category (IEC 60068-1) 40/085/56 (-40 C/+85 C/56 days damp heat test) Screw cap fixing Standard M32 x 1.5 Special fixing M27 x 1.5 for filters up to 300 A on request Approvals UL 1283, 250 V Characteristics and ordering codes IR CR VR A F V AC V DC V DC 63 100 200 300 400 VR Vtest Terminal Dimensions (mm) l +1 l1 -1 l2 -3 Ordering code Approvals 2 x 0.5 250 600 3000 M6 100 166 45 B85321A2105A630 x 2 x 1.0 250 600 2500 M6 100 166 45 B85321A2205A630 x 2 x 2.0 250 600 2500 M6 100 166 45 B85321A2405A630 x 2 x 4.7 250 350 1700 M6 100 166 45 B85321A2945A630 x 2 x 0.5 250 600 3000 M8 100 180 52 B85321A2105A101 x 2 x 1.0 250 600 2500 M8 100 180 52 B85321A2205A101 x 2 x 2.0 250 600 2500 M8 100 180 52 B85321A2405A101 x 2 x 4.7 250 350 1700 M8 100 180 52 B85321A2945A101 x 2 x 0.5 250 600 3000 M10 100 185 55 B85321A2105A201 x 2 x 1.0 250 600 2500 M10 100 185 55 B85321A2205A201 x 2 x 2.0 250 600 2500 M10 100 185 55 B85321A2405A201 x 2 x 4.7 250 350 1700 M10 100 185 55 B85321A2945A201 x 2 x 0.5 250 600 3000 M12 100 195 60 B85321A2105A301 x 2 x 1.0 250 600 2500 M12 100 195 60 B85321A2205A301 x 2 x 2.0 250 600 2500 M12 100 195 60 B85321A2405A301 - 2 x 4.7 250 350 1700 M12 100 195 60 B85321A2945A301 x 2 x 0.5 250 600 3000 M16 130 245 72 B85321A2105A401 - 2 x 1.0 250 600 2500 M16 130 245 72 B85321A2205A401 - 2 x 2.0 250 600 2500 M16 130 245 72 B85321A2405A401 - 2 x 4.7 250 350 1650 M16 130 245 72 B85321A2945A401 - x = approval granted Please read Cautions and warnings and Important notes at the end of this document. 11 01/06 1-line filters B85321A*A 55 mm, 63 ... 500 A Feedthrough filters Characteristics and ordering codes IR CR VR A F V AC V DC V DC 500 2 x 0.5 250 600 2 x 1.0 250 2 x 2.0 250 2 x 4.7 250 VR Vtest Terminal Dimensions (mm) Ordering code Approvals l +1 l1 -1 l2 -3 3000 M18 130 250 75 B85321A2105A501 - 600 2500 M18 130 250 75 B85321A2205A501 - 600 2500 M18 130 250 75 B85321A2405A501 - 350 1650 M18 130 250 75 B85321A2945A501 - x = approval granted Insertion loss (dB); typical values at 50 CR (F) 100 kHz 1 MHz 100 MHz 1 GHz 2 x 0.5 10 kHz 5 25 45 10 MHz 80 > 100 > 100 2 x 1.0 10 30 60 > 100 > 100 > 100 2 x 2.0 15 35 70 > 100 > 100 > 100 2 x 4.7 25 40 90 > 100 > 100 > 100 Dimensional drawing M Marking M32 x 1.5 A/F 10 A/F 41 8 551 15+1 2 1 SSB1273-3-E Thread Thread Tightening torque 3 +0.5 Nm M27 x 1.5 16 +2 M8 5 +0.5 Nm M32 x 1.5 24 +2.5 Nm M10 8 +2 Nm M12 12 +2 Nm M16 28 +2 Nm M18 35 +2 Nm M6 Tightening torque Please read Cautions and warnings and Important notes at the end of this document. 12 01/06 Nm EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective. 13 01/06 EMC filters Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 14 01/06 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: EPCOS: B85321A2405A401 B85321A2105A401 B85321A2502Z160 B85321A2205A401 B85321A6204B630 B85321A2502Y160 B85321A4504A750 B85321A2502V160 B85321A4504B301 B85321A2945A630 B85321A2405A301 B85321A4205A750 B85321A2502C160 B85321A2502X160 B85321A4405B301 B85321A2945A201 B85321A2205A301 B85321A2105A301 B85321A2205B201 B85321A2945A101 B85321A2502A160 B85321A2502B160 B85321A4502C160 B85321A2205B301 B85321A2205A750 B85321A2105A750 B85321A2204A750 B85321A2105A250 B85321A2105A101 B85321A4104B201 B85321A2405A101 B85321A2204A250 B85321A2105A630 B85321A2945A401 B85321A6204B250 B85321A2105A501 B85321A2405A501 B85321A2205A501 B85321A2945A301 B85321A6504B630 B85321A2405A201 B85321A4205B201 B85321A2205A201 B85321A2945A501 B85321A2945B630 B85321A2105A201