CSM_H3M_DS_E_2_2
1
Solid-state Timer
H3M
Solid-state Timer with Variable Time Ranges
Four time ranges are selectable per timer unit.
Wide timing range of 0.05 second to 30 hours can be covered
by a combination of five timer units.
Standard surface mounting type is easily convertible to flush
mounting type with the use of a special adapter (Y92F-40).
Requires only 40 x 50 mm for mounting space.
Equipped with power-ON & time-out indicators.
All standard models approved by UL, CSA, and LR.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
Note: 1. Specify both the model number and supply voltage when ordering.
2. Sockets and adapters for surface/track mounting are available optionally and therefore, place the order for them as necessary.
Timer hold-down clips (F-hook and L-hook) are supplied with the timer.
Accessories (Order Separately)
Adapter
Y92F-40
Specifications
Time Ranges
Four time ranges are available for each timer by changing the time range selector switch positions to different combinations.
Operation/resetting system Time-limit contact Instantaneous
contact
Mounting
Surface mounting Flush mounting
Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter
SPDT SPDT H3M-H H3M-H with Y92F-40 adapter
Time range code Time range selector switch
A0.05 to 0.5 s 0.5 to 5 s 0.05 to 0.5 min 0.5 to 5 min
B0.1 to 1 s 1 to 10 s 0.1 to 1 min 1 to 10 min
C0.3 to 3 s 3 to 30 s 0.3 to 3 min 3 to 30 min
Time range code Time multiplying key
D0.1 to 1 min 1 to 10 min 0.1 to 1 hrs 1 to 10 hrs
E0.3 to 3 min 3 to 30 min 0.3 to 3 hrs 3 to 30 hrs
2
H3M
Ratings
Note: 1. Color indicators for the rated voltage are provided on the front of the Timer.
Blue: 100/110/120 VAC
Red: 200/220/240 VAC
None: Other voltages
2. With DC ratings, single-phase full-wave rectified power sources may be used.
3. 90% to 110% for 12-VDC models.
Characteristics
Note: For the timer with time range code A, add ±10 ms to the respective characteristics when the time range selector switches are in the x 1 s
(0.05 to 0.5 s) position.
Rated supply voltage 100/110/120 VAC (50/60 Hz), 200/220/240 VAC (50/60 Hz),
12, 24, 48, 100, 110 VDC (see note 2)
Operating voltage range AC: 85% to 110% of rated supply voltage
DC: 80% to 110% of rated supply voltage (see note 3)
Power consumption AC: Approx. 5 VA/2 W
DC: Approx. 2 W
Control outputs 5 A at 250 VAC, resistive load (cosφ = 1)
Accuracy of operating time ±1% max. (see note)
Setting error ±10% max.
Reset time 0.1 s max.
Influence of voltage ±1% max. (see note)
Influence of temperature ±2% max. (see note)
Insulation resistance 100 M min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)
1,500 VAC, 50/60 Hz for 1 min (between contact and control circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Shock resistance Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Ambient temperature Operating: –10°C to 50°C
Storage: –25°C to 65°C
Ambient humidity Operating: 35% to 85%
Life expectancy Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
Approved standards UL (File No. E41515), CSA (File No. LR22310)
Weight Approx. 100 g
H3M
3
Engineering Data
Operation
Timing Chart
Switching operations (×103)
Load current (A)
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1).
Maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.The minimum applicable
load is 10 mA at 5 VDC (failure level: P).
H3M H3M-H
Set time Set time Set time Set time
Rt Rt
Rt: Resetting time Rt: Resetting time
7-2 (Power)
1-4 (NC)
1-3 (NO)
8-5 (NC)
8-6 (NO)
2-7 (Power)
8-5 (NC)
8-6 (NO)
1-4 (NC)
1-3 (NO)
Power ON
indicator lamp
Time-out
indicator
Power ON
indicator lamp
Time-out
indicator
4
H3M
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Accessories (Order Separately)
H3M(-H)
Y92F-40 Adapter w
i
th Flush Mount
i
ng
Track Mounted/Front Connecting Socket
PF085A
Terminal Arrangement
(Top View)
Mounting Holes
Eight, M3.5 × 7 sems
Four, 5 dia. or M4 holes
Note: When two or more timers mounted in line are to be continuously energized at the same time after the lapse
of the set time, be sure to limit the carry current to less than 1 A. When using the timers at an ambient
temperature of more than 40°C, be sure to reset the timers immediately after the set time has elapsed.
Mounting Height of
Timer with Socket
Note: There are no restrictions to
the mounting direction.
Two, 4.5 dia.
holes
63.5
75.5
Hold-down Clips (Attached)
PHC-1 For PF085A
F-hook
H3M
5
P3G-08
Terminal Arrangement
(Bottom View)
Terminal Arrangement
(Bottom View)
Mounting Holes
Back Connecting Socket
PL08
Mounting Track
PFP-100N/PFP-50N
End Plate
PFP-M
Note: This dimension applies to PFP-50N.
Spacer
PFP-S
(See note)
Two, 2 dia.
holes
Mounting Height of
Timer with Socket
Mounting Height of
Timer with Socket
Two, 3.5 dia. or M3
socket mounting
holes
6
H3M
Installation
Connection
Safety Precautions
Refer to Safety Precautions for All Timers.
Power Source Connection
Because the AC-operated version is a capacitive load, the solid-state
relay to be used must be rated at a dielectric strength two times as
that of the timer to switch the power source of the timer.
The H3M contains a capacitor-drop power circuit. Use a sinusoidal
power supply with a commercial frequency. Do not use power
supplies with a high frequency component (such as inverter power
supplies) for Timers with 100 to 240-VAC specifications. Using these
power supplies can damage internal circuits.
How to Change the Time Range
The H3M is provided with two time range selector switches. One is
on the lower right side A of the front panel and the other on the lower
left side. Change the positional combination of the time range
selector switches with a flat-blade screwdriver as desired.
!CAUTION
Be sure to turn the power off before changing the time specification.
Changing the time range while the timer is in operation may result in
a malfunction.
Connections
Connecting the Operating Power Supply
If using an AC power supply, connect it between terminals 2 and 7. If
using a DC power supply, connect the positive line to terminal 7 and
the negative line to terminal 2. An AC power supply can be
connected without considering polarity, but the DC power supply
lines must be connected as specified.
Other Precautions
A DC power supply must have 50% or less ripple and the average
voltage must be within the rated supply voltage specification.
A P3G-08 Socket can be used instead of a US-08 Socket to reduce
the depth. Also, the P3G-08 has screw terminals, making
maintenance easier.
H3M H3M-H
A
US-08 P3G-08
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
H3M-AC120-A H3M-AC120-B H3M-AC120-C H3M-AC120-D H3M-AC120-E H3M-AC200/220/240-A H3M-
AC200/220/240-D H3M-AC220-B H3M-AC240-C H3M-AC24-B H3M-DC24-A H3M-DC24-B H3M-DC24-C H3M-
DC24-D H3M-H-AC100/110/120-A H3M-H-AC100/110/120-C H3M-H-AC120-B H3M-H AC200/220/240 C H3M-H-
AC200/240-D H3M-H DC125 B H3M-H DC12 B H3M-H-DC12-C H3M-US-DC12-B H3M DC48 A H3M DC48 C
H3M DC110 B