Solid-state Timer H3M CSM_H3M_DS_E_2_2 Solid-state Timer with Variable Time Ranges * Four time ranges are selectable per timer unit. * Wide timing range of 0.05 second to 30 hours can be covered by a combination of five timer units. * Standard surface mounting type is easily convertible to flush mounting type with the use of a special adapter (Y92F-40). * Requires only 40 x 50 mm for mounting space. * Equipped with power-ON & time-out indicators. * All standard models approved by UL, CSA, and LR. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information Operation/resetting system Time-limit operation/ self-resetting Time-limit contact Instantaneous contact Mounting Surface mounting Flush mounting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter Note: 1. Specify both the model number and supply voltage when ordering. 2. Sockets and adapters for surface/track mounting are available optionally and therefore, place the order for them as necessary. Timer hold-down clips (F-hook and L-hook) are supplied with the timer. Accessories (Order Separately) Adapter Y92F-40 Specifications Time Ranges Four time ranges are available for each timer by changing the time range selector switch positions to different combinations. Time range code Time range selector switch A 0.05 to 0.5 s 0.5 to 5 s 0.05 to 0.5 min 0.5 to 5 min B 0.1 to 1 s 1 to 10 s 0.1 to 1 min 1 to 10 min C 0.3 to 3 s 3 to 30 s 0.3 to 3 min 3 to 30 min Time range code Time multiplying key D 0.1 to 1 min 1 to 10 min 0.1 to 1 hrs 1 to 10 hrs E 0.3 to 3 min 3 to 30 min 0.3 to 3 hrs 3 to 30 hrs 1 H3M Ratings Rated supply voltage 100/110/120 VAC (50/60 Hz), 200/220/240 VAC (50/60 Hz), 12, 24, 48, 100, 110 VDC (see note 2) Operating voltage range AC: 85% to 110% of rated supply voltage DC: 80% to 110% of rated supply voltage (see note 3) Power consumption AC: Approx. 5 VA/2 W DC: Approx. 2 W Control outputs 5 A at 250 VAC, resistive load (cos = 1) Note: 1. Color indicators for the rated voltage are provided on the front of the Timer. Blue: 100/110/120 VAC Red: 200/220/240 VAC None: Other voltages 2. With DC ratings, single-phase full-wave rectified power sources may be used. 3. 90% to 110% for 12-VDC models. Characteristics Accuracy of operating time 1% max. (see note) Setting error 10% max. Reset time 0.1 s max. Influence of voltage 1% max. (see note) Influence of temperature 2% max. (see note) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts) 1,500 VAC, 50/60 Hz for 1 min (between contact and control circuit) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude Malfunction: 10 to 55 Hz with 0.5-mm double amplitude Shock resistance Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 100 m/s2 (approx. 10G) Ambient temperature Operating: Storage: Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) Approved standards UL (File No. E41515), CSA (File No. LR22310) Weight Approx. 100 g -10C to 50C -25C to 65C Note: For the timer with time range code A, add 10 ms to the respective characteristics when the time range selector switches are in the x 1 s (0.05 to 0.5 s) position. 2 H3M Switching operations (x103) Engineering Data Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos = 1). Maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected.The minimum applicable load is 10 mA at 5 VDC (failure level: P). Load current (A) Operation Timing Chart H3M Set time Rt H3M-H Set time Set time Rt Set time 2-7 (Power) 7-2 (Power) 1-4 (NC) 8-5 (NC) 1-3 (NO) 8-6 (NO) 8-5 (NC) 1-4 (NC) 8-6 (NO) Power ON indicator lamp Time-out indicator 1-3 (NO) Power ON indicator lamp Time-out indicator Rt: Resetting time Rt: Resetting time 3 H3M Dimensions Note: All units are in millimeters unless otherwise indicated. H3M(-H) Accessories (Order Separately) Y92F-40 Adapter with Flush Mounting 63.5 75.5 Note: When two or more timers mounted in line are to be continuously energized at the same time after the lapse of the set time, be sure to limit the carry current to less than 1 A. When using the timers at an ambient temperature of more than 40C, be sure to reset the timers immediately after the set time has elapsed. Track Mounted/Front Connecting Socket PF085A Terminal Arrangement (Top View) Eight, M3.5 x 7 sems Two, 4.5 dia. holes Mounting Holes Mounting Height of Timer with Socket Four, 5 dia. or M4 holes Note: There are no restrictions to the mounting direction. Hold-down Clips (Attached) PHC-1 For PF085A F-hook 4 H3M Back Connecting Socket PL08 Two, 2 dia. holes Terminal Arrangement (Bottom View) Mounting Height of Timer with Socket Mounting Holes Two, 3.5 dia. or M3 socket mounting holes P3G-08 Mounting Height of Timer with Socket Terminal Arrangement (Bottom View) Mounting Track End Plate Spacer PFP-100N/PFP-50N PFP-M PFP-S (See note) Note: This dimension applies to PFP-50N. 5 H3M Installation Connection H3M H3M-H Safety Precautions Refer to Safety Precautions for All Timers. Power Source Connection Connections Because the AC-operated version is a capacitive load, the solid-state relay to be used must be rated at a dielectric strength two times as that of the timer to switch the power source of the timer. Connecting the Operating Power Supply If using an AC power supply, connect it between terminals 2 and 7. If using a DC power supply, connect the positive line to terminal 7 and the negative line to terminal 2. An AC power supply can be connected without considering polarity, but the DC power supply lines must be connected as specified. The H3M contains a capacitor-drop power circuit. Use a sinusoidal power supply with a commercial frequency. Do not use power supplies with a high frequency component (such as inverter power supplies) for Timers with 100 to 240-VAC specifications. Using these power supplies can damage internal circuits. How to Change the Time Range The H3M is provided with two time range selector switches. One is on the lower right side A of the front panel and the other on the lower left side. Change the positional combination of the time range selector switches with a flat-blade screwdriver as desired. Other Precautions * A DC power supply must have 50% or less ripple and the average voltage must be within the rated supply voltage specification. * A P3G-08 Socket can be used instead of a US-08 Socket to reduce the depth. Also, the P3G-08 has screw terminals, making maintenance easier. US-08 P3G-08 A !CAUTION Be sure to turn the power off before changing the time specification. Changing the time range while the timer is in operation may result in a malfunction. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 6 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: H3M-AC120-A H3M-AC120-B H3M-AC120-C H3M-AC120-D H3M-AC120-E H3M-AC200/220/240-A H3MAC200/220/240-D H3M-AC220-B H3M-AC240-C H3M-AC24-B H3M-DC24-A H3M-DC24-B H3M-DC24-C H3MDC24-D H3M-H-AC100/110/120-A H3M-H-AC100/110/120-C H3M-H-AC120-B H3M-H AC200/220/240 C H3M-HAC200/240-D H3M-H DC125 B H3M-H DC12 B H3M-H-DC12-C H3M-US-DC12-B H3M DC48 A H3M DC48 C H3M DC110 B