IL600A Series Isolators
Isoloop® is a registered trademark of NVE Corporation.
*U.S. Patent numbers 5,831,426; 6,300,617 and others.
REV. Z
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 www.isoloop.com iso-info@nve.com ©NVE Corporation
Passive-Input Digital Isolators
Open Drain Outputs
Functional Diagrams
IN
1
OUT
2
IN
1
IN
1
IN
2
GND
OUT
1
IN
2
V
OE
OUT
1
GND
OUT
1
OUT
2
GND
GND
V
DD2
V
DD1
IL610A
IL611A
IL612A
Features
10 Mbps data rate
Flexible inputs with very wide input voltage range
5 mA input current
Failsafe output (logic high output for zero coil current)
No carrier or clock for low EMI emissions and susceptibility
3 V to 5 V power supplies
1000 VRMS/1500 VDC high voltage endurance
44000 year barrier life
Low power dissipation
40°C to 85°C temperature range
UL 1577 recognized; IEC 60747-5-5 (VDE 0884) certified
8-Pin MSOP, SOIC, and PDIP packages
Applications
General purpose optocoupler replacement
Wired-OR alarms
SPI interface
I2C
RS-485, RS-422, or RS-232
Space-critical multi-channel applications
Isolated relays and actuators
Description
The IL600A-Series are isolated signal couplers with open-
drain outputs. They have a similar interface but better
performance and higher package density than optocouplers.
The devices are manufactured with NVE’s patented*
IsoLoop® spintronic Giant Magnetoresistive (GMR)
technology for small size, high speed, and low power.
A unique ceramic/polymer composite barrier provides
excellent isolation and virtually unlimited barrier life.
A resistor sets the input current; a capacitor in parallel with
the current-limit resistor provides improved dynamic
performance.
These versatile components simplify inventory requirements
by replacing a variety of optocouplers, functioning over a
wide range of data rates, edge speeds, and power supply
levels. The devices are available in MSOP, SOIC, and PDIP
packages, as well as bare die.
IL600A Series Isolators
2
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Absolute Maximum Ratings(1)
Parameters Symbol Min. Typ. Max. Units Test Conditions
Storage Temperature TS 55 150 °C
Ambient Operating Temperature TA 40 85 °C
Supply Voltage VDD 0.5 7 V
DC Input Current IIN 25 25 mA
AC Input Current (Single-Ended Input) IIN 35 35 mA
AC Input Current (Differential Input) IIN 75 75 mA
Output Voltage VO 0.5 VDD+1.5 V
Maximum Output Current IO 10 10 mA
ESD 2 kV HBM
Note 1: Operating at absolute maximum ratings will not damage the device. Parametric performance is not guaranteed at absolute maximum ratings.
Recommended Operating Conditions
Parameters Symbol Min. Typ. Max. Units Test Conditions
Ambient Operating Temperature TA 40 85 °C
Supply Voltage VDD 3.0 5.5 V
Open Drain Reverse Voltage VSD 0.5 V
Open Drain Voltage VDS 6.5 V
Open Drain Load Current IOD 7 mA
Common Mode Input Voltage VCM 400 VRMS
Insulation Specifications
Parameters Symbol Min. Typ. Max. Units Test Conditions
Creepage Distance (external)
MSOP 3.01 mm
0.15'' SOIC 4.03 mm
PDIP 7.08 mm
Total Barrier Thickness 0.012 0.013 mm
Leakage Current 0.2 μA 240 VRMS, 60 Hz
Barrier Resistance RIO >1014 Ω 500 V
Barrier Capacitance CIO 7 pF f = 1 MHz
Comparative Tracking Index CTI 175 V Per IEC 60112
High Voltage Endurance
(Maximum Barrier Voltage
for Indefinite Life)
AC
DC
VIO
1000
1500
VRMS
VDC
At maximum
operating temperature
Barrier Life 44000 Years 100°C, 1000 VRMS, 60%
CL activation energy
IL600A Series Isolators
3
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Safety and Approvals
IEC 60747-5-5 (VDE 0884) (File Number 5016933-4880-0001)
Working Voltage (VIORM) 600 VRMS (848 VPK); basic insulation; pollution degree 2
Transient overvoltage (VIOTM) and surge voltage (VIOSM) 4000 VPK
Each part tested at 1590 VPK for 1 second, 5 pC partial discharge limit
Samples tested at 4000 VPK for 60 sec.; then 1358 VPK for 10 sec. with 5 pC partial discharge limit
IEC 61010-1 (Edition 2; TUV Certificate Numbers N1502812; N1502812-101)
Reinforced Insulation; Pollution Degree II; Material Group III
Part No. Suffix Package Working Voltage
-1 MSOP 150 VRMS
-2 PDIP 300 VRMS
-3 SOIC 150 VRMS
None Wide-body SOIC/True 8™ 300 VRMS
UL 1577 (Component Recognition Program File Number E207481)
Each part other than MSOP tested at 3000 VRMS (4240 VPK) for 1 second; each lot sample tested at 2500 VRMS (3530 VPK) for 1 minute
MSOP tested at 1200 VRMS (1768 VPK) for 1 second; each lot sample tested at 1500 VRMS (2121 VPK) for 1 minute
Soldering Profile
Per JEDEC J-STD-020C; MSL 1
Electrostatic Discharge Sensitivity
This product has been tested for electrostatic sensitivity to the limits stated in the specifications. However, NVE recommends that all integrated
circuits be handled with appropriate care to avoid damage. Damage caused by inappropriate handling or storage could range from performance
degradation to complete failure.
IL600A Series Isolators
4
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
IL610A Pin Connections
1 NC No internal connection
2 IN+ Coil connection
3 IN Coil connection
4 NC No internal connection
5 GND Ground return for VDD
6 OUT Data out
7
VOE Output enable.
Internally held low with 100 kΩ
8 VDD Supply Voltage
IL610A
IL611A Pin Connections
1 IN1+ Channel 1 coil connection
2 IN1 Channel 1 coil connection
3 IN2+ Channel 2 coil connection
4 IN2 Channel 2 coil connection
5 GND Ground return for VDD
6 OUT2 Data out, channel 2
7 OUT1 Data out, channel 1
8 VDD Supply Voltage
IL611A
IL612A Pin Connections
1 IN1 Data in, channel 1
2 VDD1 Supply Voltage 1
3 OUT2 Data out, channel 2
4 GND1 Ground return for VDD1
5 GND2 Ground return for VDD2
6 IN2 Data in, channel 2
7 VDD2 Supply Voltage 2
8 OUT1 Data out, channel 1
IL612A
IN1+V
DD
IN1- OUT1
IN2+OUT2
IN2-GND
IN1OUT1
VDD1 VDD2
OUT2IN2
GND1GND2
NC VDD
IN+ VOE
IN- OUT
NC GND
IL600A Series Isolators
5
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Operating Specifications
Input Specifications (VDD = 3 V 5.5 V; T = 40°C 85°C unless otherwise stated)
Parameters Symbol Min. Typ. Max. Units Test Conditions
Coil Input Resistance RCOIL 47 85 112 T = 25°C
31 85 128 T = 40°C 85°C
Coil Resistance Temperature Coefficient TC RCOIL 0.2 0.25 /°C
Coil Inductance LCOIL 9 nH
DC Input Threshold (5 V) IINH-DC 0.5 1 mA
Test Circuit 1;
VDD = 4.5 V 5.5 V
IINL-DC 3.5 5 mA
DC Input Threshold (3 V) IINH-DC 0.5 0.3 mA
Test Circuit 1;
VDD = 3V 3.6 V;
no boost cap
IINL-DC 5 8 mA
Dynamic Input Threshold (3 V) IINH-BOOST 0.5 1 mA
VDD = 3V 3.6 V;
tIR = tIF = 3 ns;
CBOOST = 16 pF
IINL-BOOST 3.5 5 mA
Differential Input Threshold
IINH-DIFF 0.5 1 mA
Test Circuit 2;
VDD = 3V 5.5 V;
input current reverses;
boost cap not required
IINL-DIFF 3.5 5 mA
Failsafe Input Current(1) (5 V) IFS-HIGH 25 0.5 mA
Test Circuit 1;
VDD = 4.5 V 5.5 V
IFS-LOW 5 25 mA
Failsafe Input Current(1) (3 V) IFS-HIGH 25 0.3 mA
Test Circuit 1;
VDD = 3 V 3.6 V
IFS-LOW 8 25 mA
Input Signal Rise and Fall Times tIR, tIF 1 μs
Common Mode Transient Immunity |CMH|,|CML| 15 20 kV/μs VT = 300 V
p
ea
k
Notes:
1. Failsafe Operation is defined as the guaranteed output state which will be achieved if the DC input current falls between the input levels specified
(see Test Circuit 1 for details). Note if Failsafe to Logic Low is required, the DC current supplied to the coil must be at least 8 mA using 3.3 V supplies versus
5 mA for 5 V supplies.
+V V
DD
GND
1
GND
3
25
6
7
8
15pF
10nF
R
limit
C
boost
12
2K
IL610A
-
+
GND
12
1K
+V V
DD
GND
3
2
5
6
7
8
-
+
15 pF
10 nF
IL610A
R
limit
2K
Test Circuit 1 (Single-Ended) Test Circuit 2 (Differential)
IL600A Series Isolators
6
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Electrical Specifications (VDD = 3 V 5.5 V; T = 40°C 85°C unless otherwise stated)
Parameters Symbol Min. Typ. Max. Units Test Conditions
Quiescent Supply Current (5 V)
IL610A IDD 2 3 mA
VDD = 5 V, IIN=0
Rpullup = open circuit
IL611A IDD 4 6 mA
IL612A IDD1 2 3 mA
IL612A IDD2 2 3 mA
Quiescent Supply Current (3.3 V)
IL610A IDD 1.3 2 mA
VDD= 3.3 V, IIN=0
Rpullup = open circuit
IL611A IDD 2.6 4 mA
IL612A IDD1 1.3 2 mA
IL612A IDD2 1.3 2 mA
Logic High Output Voltage
(
1
)
VOH V
DD V Off State
Logic Low Output Voltage VOL 0 0.1 V
IO = 20
μ
A
0.4 0.8 V IO = 4 mA
Logic Output Current |IO| 7 10 mA
Switching Specifications (VDD = 3 V 5.5 V; T = 40°C 85°C unless otherwise stated)
Parameters Symbol Min. Typ. Max. Units Test Conditions
Input Signal Rise and Fall Times tIR, tIF 10
μs
Test Circuit 1;
tIR = tIF = 3 ns;
CBOOST = 16 pF
Data Rate 10 Mbps
Minimum Pulse Width PW 100 ns
Propagation Delay Input to Output
(High to Low) tPHL 20 25 ns
Propagation Delay Input to Output
(Low to High) tPLH 50 75 ns
Notes:
1. VDD refers to the supply voltage on the output side of the isolated channel.
2. Failsafe Operation is defined as the guaranteed output state which will be achieved if the DC input current falls between the input levels specified
(see Test Circuit 1 for details). Note if Failsafe to Logic Low is required, the DC current supplied to the coil must be at least 8 mA using 3.3 V supplies versus
5 mA for 5 V supplies.
IL600A Series Isolators
7
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Applications Information
IL600-Series Isolators are current mode devices. Changes in current flow into the input coil result in logic state changes at the
output. As shown in Figure 1, output logic high is the zero input current state.
Coil Polarity
The device switches to logic low if current flows from (In) to (In+).
Note that the designations “In“ and “In+” refer to logic levels, not
current flow. Positive values of current mean current flow into
the In input.
Input Resistor Selection
Resistors set the coil input current (see Figure 2). There is no limit to
input voltages because there are no semiconductor input structures.
Worst-case logic low threshold current is 8 mA, which is for single-
ended operation with a 3 V supply. In differential mode, where the
input current reverses, the logic low threshold current is 5 mA for the
range of supplies. A “boost capacitor” creates current reversals at edge
transitions, reducing the input logic low threshold current to the
differential level of 5 mA.
Typical Resistor Values
The table shows typical
values for the external
resistor for 5 mA coil
current. The values are
approximate and should be adjusted for temperature or other
application specifics. If the expected temperature range is large, 1%
tolerance resistors may provide additional design margin.
Single-Ended or Differential Input
The IL610, IL611, IL613, and channel 1 of the IL614 can be run with
single-ended or differential inputs (see Test Circuits on page 5). In the
differential mode, current will naturally flow through the coil in both
directions without a boost capacitor, although the capacitor can still be
used for increased external field immunity or improved PWD.
Absolute Maximum recommended coil current in single-ended mode
is 25 mA while differential mode allows up to ±75 mA to flow. The
difference in specifications is due to the risk of electromigration of
coil metals under constant current flow. In single ended mode, long-term DC current flow above 25 mA can cause erosion of the
coil metal. In differential mode, erosion takes place in both directions as each current cycle reverses and has a net effect of zero up
to the absolute maximum current.
An advantage over optocouplers and other high-speed couplers in differential mode is that no reverse bias protection for the input
structure is required for a differential signal.
One of the more common applications is for an isolated Differential Line Receiver. For example, RS-485 can drive an IL610
directly for a fraction of the cost of an isolated RS-485 node (see Illustrative Applications).
3.5
5
High
Low
Logic State
Coil Current
mA
1.5
t
t
Figure 1. Typical IL600-Series Transfer Function
VINH
VINL
ICOIL
R1
85
Input
Coil
Figure 2. Limiting Resistor Calculation
Equivalent Circuit
VCOIL 0.125W, 5% Resistor
3.3 V 510
Ω
5 V 820
Ω
IL600A Series Isolators
8
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
250016 5000
3
500
1000
Signal
Rise/Fall Time (ns)
CBoost (pF)
250016 5000
3
500
1000
Signal
Rise/Fall Time (ns)
CBoost (pF)
Non-inverting and Inverting Configurations
IL600-Series Isolators can be configured in non-
inverting and inverting configurations (see Figure
3). In a typical non-inverting circuit, the In
terminal is connected via a 1 k input resistor to
the supply rail, and the input is connected to the In+
terminal. The supply voltage is +5 V and the input
signal is a 5 V CMOS signal. When a logic high
(+5 V) is applied to the input, the current through
the coil is zero. When the input is a logic low (0 V),
at least 5 mA flows through the coil from the In
side to the In+ side.
The inverting configuration is similar to standard
logic. In the inverting configuration, the signal into
the coil is differential with respect to ground. The
designer must ensure that the difference between
the logic low voltage and the coil ground is such
that the residual coil current is less than 0.5 mA.
The IL612 and IL614 devices have some inputs
that do not offer inverting operation. The IL612
coil In input is hardwired internally to the device
power supply; therefore it is important to ensure the
isolator power supply is at the same voltage as the
power supply to the source of the input logic signal.
The IL614 has a common coil In for two inputs.
This pin should be connected to the power supply
for the logic driving channels 2 and 3, and the
channels run should be run in non-inverting mode.
Both single ended and differential inputs can be
handled without reverse bias protection.
Boost Capacitor
The boost capacitor in parallel with the current-limiting resistor boosts the instantaneous coil current at the signal transition. This
ensures switching and reduces propagation delay and reduces pulse-width distortion.
Select the value of the boost capacitor based on the rise and fall
times of the signal driving the inputs. The instantaneous boost
capacitor current is proportional to input edge speeds ( ). Select a
capacitor value based on the rise and fall times of the input signal to be
isolated that provides approximately 20 mA of additional “boost”
current. Figure 4 is a guide to boost capacitor selection. For high-speed
logic signals (tr,tf < 10 ns), a 16 pF capacitor is recommended. The
capacitor value is generally not critical; if in doubt, choose a higher
value.
VDD
GND2
5
6
7
8
Note: C1is 47 nF ceramic.
Non-Inverting Circuit
Data Out
C
1
1
+5 V
GND1
820R
3
2
Data In
Cboost
IL610A
-
+
2K
+5 V VDD
GND1GND2
820R
3
2
Note: C1is 47 nF ceramic.
Inverting Circuit
Data In
C
boost
5
6
7
8
Data Out
C
1
IL610A
-
+
2K
Figure 3. Non-inverting and inverting circuits
Figure 4. Cboost Selector
dV
dt
C
IL600A Series Isolators
9
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Dynamic Power Consumption
Power consumption is proportional to duty cycle, not data rate. The use of NRZ coding minimizes power dissipation since no
additional power is consumed when the output is in the high state. In differential mode, where the logic high condition may still
require a current to be forced through the coil, power consumption will be higher than a typical NRZ single ended configuration.
Power Supply Decoupling
47 nF low-ESR ceramic capacitors are recommended to decouple the power supplies. The capacitors should be placed as close as
possible to the appropriate VDD pin.
Maintaining Creepage
Creepage distances are often critical in isolated circuits. In addition to meeting JEDEC standards, NVE isolator packages have
unique creepage specifications. Standard pad libraries often extend under the package, compromising creepage and clearance.
Similarly, ground planes, if used, should be spaced to avoid compromising clearance. Package drawings and recommended pad
layouts are included in this datasheet.
Electromagnetic Compatibility and Magnetic Field Immunity
Because IL600-Series Isolators are completely static, they have the lowest emitted noise of any non-optical isolators.
IsoLoop Isolators operate by imposing a magnetic field on a GMR sensor, which translates the change in field into a change in
logic state. A magnetic shield and a Wheatstone Bridge configuration provide good immunity to external magnetic fields.
Immunity to external magnetic fields can be enhanced by proper orientation of the device with respect to the field direction, the
use of differential signaling, and boost capacitors.
1. Orientation of the device with respect to the field direction
An applied field in the “H1” direction is the worst case for
magnetic immunity. In this case the external field is in the same
direction as the applied internal field. In one direction it will
tend to help switching; in the other it will hinder switching.
This can cause unpredictable operation.
An applied field in direction “H2” has considerably less effect
and results in higher magnetic immunity.
NC V
DD
IN+ V
OE
IN- OUT
NC GND
2. Differential Signaling and Boost Capacitors
Regardless of orientation, driving the coil differentially improves magnetic immunity. This is because the logic high state is driven
by an applied field instead of zero field, as is the case with single-ended operation. The higher the coil current, the higher the
internal field, and the higher the immunity to external fields. Optimal magnetic immunity is achieved by adding the boost
capacitor.
Method Approximate Immunity Immunity Description
Field applied in H1 direction ±20 Gauss A DC current of 16 A flowing in a conductor
1 cm from the device could cause disturbance.
Field applied in H2 direction ±70 Gauss A DC current of 56 A flowing in a conductor
1 cm from the device could cause disturbance.
Field applied in any direction but with boost
capacitor (16 pF) in circuit ±250 Gauss A DC current of 200 A flowing in a conductor
1 cm from the device could cause disturbance.
Data Rate and Magnetic Field Immunity
It is easier to disrupt an isolated DC signal with an external magnetic field than it is to disrupt an isolated AC signal. Similarly, a
DC magnetic field will have a greater effect on the device than an AC magnetic field of the same effective magnitude. For
example, signals with pulses longer than 100 μs are more susceptible to magnetic fields than shorter pulse widths.
H1
H2
IL600A Series Isolators
IsoLoop® is a registered trademark of NVE Corporation.
*U.S. Patent numbers 5,831,426; 6,300,617 and others.
REV. V
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.isoloop.com ©NVE Corporation
Illustrative Applications
GND
2
V
DD2
C
boost
3
2
5
6
7
8
C
2
2
3
2
IL610A
-
+
B/Z
ISL8485
D
C
1
V
DD1
GND
1
4
5
7
1
Notes:
Cboost is application specific
All other capacitors are 47 nF ceramic
A/Y
8
6
1
R
R
Isolated RS-485 and RS-422 Receivers Using IL610As
IL610As can be used as simple isolated RS-485 or RS-422 receivers, terminating signals at
the IL610A for a fraction of the cost of an isolated node. Cabling is greatly simplified by
eliminating the need to power the input side of the receiving board. No current-limiting
resistor is needed for a single receiver because it will draw less current than the driver
maximum. Current limiting resistors allow at least eight nodes without exceeding the
maximum load of the transceiver chip. Placement of the current-limiting resistors on both
lines provides better dynamic signal balance. There is no need for line termination resistors
because the IL610A coil resistance of approximately 85 is close to the characteristic
impedance of most cables. The circuit is intrinsically open circuit failsafe because the
IL610A is guaranteed to switch to the high state when the coil input current is less than
500 µA. For higher speed, a faster output device (such the CMOS-output IL600-Series Isolators) are needed as well as possibly
better impedance matching.
Number of
Nodes
Current Limit
Resistors (Ω)
1 None
2 17
3 22
4 27
5 27
6 2
7 30
8 30
IL600A Series Isolators
11
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
2K
+5 V
Neutral
Load
47nF
3
2
5
6
8
-
+
IL610A
GND1
10K 0.5W
120V Hot
74HC123
100K
1µF
Monitor Out
15
14
13
16
8
2
3
1
+
10K 0.5W
Isolated 120V Line Monitor
The wide input voltage range of IL600 Isolators allows connection to line voltage through current-limiting resistors. Unlike
optocouplers, input voltage can reverse without damaging the inputs. In this illustrative circuit, “Monitor Out” goes low when
line voltage drops significantly. The 74HC123 monostable converts the 60 Hz isolator output to a monitor signal.
System Error
R
+5 V
GND
1
Notes:
C
boost
is application specific
All other capacitors are 47 nF ceramic
L
+5 V
C
3
1K
V
3
3
2
8
6
5
Sensor 3
Cboost
-
+
IL610A
C
2
1K
V
2
3
2
8
6
5
Sensor 2
Cboost
-
+
IL610A
C
1
1K
V
1
3
2
8
6
5
Sensor 1
Cboost
-
+
IL610A
Multi-channel Isolated Alarm Monitor
The open-drain outputs of IL600A-Series Isolators allow wired-OR outputs. The inputs can be configured for inverting or non-
inverting operation (see Applications Information), and a very wide input voltage range is possible. This illustrative circuit
provides fail-safe output (logic high output for zero coil current) and typical logic output sink current of 10 mA for each
isolator.
IL600A Series Isolators
12
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
8
7
5
6
2
1
3
4
5V
5V
GND
1
GND
2
2K2 10K
750R
750R
C3
C2
C1
3
2
8
1
4
½ P82B96
SDA
270 pF
16 pF
SDA_iso
Notes:
C1, C2, and C3 are 47nF ceramic
Resistor values change for 3 V operation
750R
V
DD2
V
DD1
IL612A
Isolation of I2C Nodes
This circuit provides bidirectional isolation of I²C bus signals with no restrictions on data rate and none of the I²C bus latch-up
problems common with other isolation circuits. The SCL section is similar as shown in the schematic using the other half of the
P82B96.
IL600A Series Isolators
13
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Package Drawings
8-pin MSOP (-1 suffix)
0.114 (2.90)
0.114 (2.90)
0.016 (0.40)
0.005 (0.13)
0.009 (0.23)
0.027 (0.70)
0.010 (0.25)
0.002 (0.05)
0.043 (1.10)
0.032 (0.80)
0.006 (0.15)
0.016 (0.40)
0.189 (4.80)
0.197 (5.00)
0.122 (3.10)
0.122 (3.10)
Dimensions in inches (mm); scale = approx. 5X
0.024 (0.60)
0.028 (0.70)
NOTE: Pin spacing is a BASIC
dimension; tolerances
do not accumulate
8-pin SOIC Package (-3 suffix)
0.188 (4.77)
0.197 (5.00)
0.049 (1.24)
0.051 (1.30)
0.004 (0.1)
0.012 (0.3)
NOTE: Pin spacing is a BASIC
dimension; tolerances
do not accumulate
0.054 (1.4)
0.072 (1.8)
0.228 (5.8)
0.244 (6.2)
0.150 (3.8)
0.157 (4.0)
0.040 (1.02)
0.050 (1.27)
0.013 (0.3)
0.020 (0.5)
0.007 (0.2)
0.013 (0.3)
0.016 (0.4)
0.050 (1.3)
NOM
Dimensions in inches (mm); scale = approx. 5X
8-pin PDIP (-2 suffix)
0.28 (7.1)
0.33 (8.4)
0.30 (7.6)
0.38 (9.7)
0.008 (0.2)
0.015 (0.4)
Dimensions in inches (mm); scale = approx. 2.5X
0.345 (8.76)
0.40 (10.2)
0.27 (6.9)
0.24 (6.1)
0
10
0.055 (1.40)
0.065 (1.65)
0.030 (0.76)
0.045 (1.14)
0.014 (0.36)
0.045 (1.14)
0.070 (1.78)
0.09 (2.3)
0.11 (2.8)
0.015 (0.38)
0.040 (1.02)
0.13 (3.30)
0.17 (4.32)
0.023 (0.58)
NOTE:
Pin spacing is a BASIC
dimension; tolerances
do not accumulate
IL600A Series Isolators
14
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Recommended Pad Layouts
8-pin MSOP Pad Layout
0.025 (0.65)
0.227 (5.77)
0.017 (0.43)
8 PLCS
0.120
(3.05)
Dimensions in inches (mm); scale = approx. 5X
8-pin SOIC Pad Layout
0.275 (6.99)
0.050 (1.27)
0.020 (0.51)
8 PLCS
Dimensions in inches (mm); scale = approx. 5X
0.160 (4.05)
IL600A Series Isolators
15
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Ordering Information and Valid Part Numbers
IL 610 A - 1 E TR13 IL610A Valid
Part Numbers
IL610A-1E
IL610A-2E
IL610A-3E
IL610A-5
IL610A-1ETR7
IL610A-3ETR7
IL610A-1ETR13
IL610A-3ETR13
IL611A Valid
Part Numbers
IL611A-1E
IL611A-2E
IL611A-3E
IL611A-1ETR7
IL611A-3ETR7
IL611A-1ETR13
IL611A-3ETR13
IL612A Valid
Part Numbers
IL612A-2E
IL612A-3E
IL612A-3ETR7
IL612A-3ETR13
Bulk Packaging
Blank = Tube
TR7 = 7'' Tape and Reel
TR13 = 13'' Tape and Reel
Package
E = RoHS Compliant
Package Type
-1 = MSOP
-2 = PDIP
-3 = SOIC
-5 = Bare die
Output Type
Blank = CMOS Output
A = Open Drain Output
Base Part Number
610 = Single Channel
611 = 2 Transmit Channels
612 = 1 Transmit Channel,
1 Receive Channel
Product Family
IL = Isolators
RoHS
COMPLIANT
IL600A Series Isolators
16
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Revision History
ISB-DS-001-IL600A-Z
November 2013 Changes
IEC 60747-5-5 (VDE 0884) certification.
Upgraded from MSL 2 to MSL 1.
Rearranged input threshold specifications so maximum is more than minimum.
ISB-DS-001-IL600A-Y
Changes
Added VDE 0884 pending.
Added monostable to line monitor circuit (p. 11).
Clarified circuit polarities.Updated package drawings.
Added recommended solder pad layouts (p. 14).
ISB-DS-001-IL600A-X
Changes
Detailed isolation and barrier specifications.
ISB-DS-001-IL600A-W Changes
Clarified Test Circuit 2 differential operation diagram (p.4).
ISB-DS-001-IL600A-V
Changes
Separated and clarified Input Specifications.
Added minimum/maximum coil resistance specifications.
Merged and simplified “Operation” and “Applications” sections.
ISB-DS-001-IL600A-U Changes
Update terms and conditions.
ISB-DS-001-IL600A-T
Changes
Additional changes to pin spacing specification on MSOP package drawing.
ISB-DS-001-IL600A-S Changes
Changed pin spacing specification on MSOP package drawing.
ISB-DS-001-IL600A-R Changes
Clarified failsafe operation input current (p. 4).
ISB-DS-001-IL600A-Q
Changes
P. 2—Deleted MSOP IEC61010 approval.
ISB-DS-001-IL600A-P
Changes
Added EMC details.
ISB-DS-001-IL600A-O Changes
Clarified I2C application diagram and expanded caption (p. 13).
ISB-DS-001-IL600A-N
Changes
IEC 61010 approval for MSOP versions.
ISB-DS-001-IL600A-M Changes
Specify coil resistance as typical only.
Revise section on calculating limiting resistors.
ISB-DS-001-IL600A-L
Changes
Note on all package drawings that pin-spacing tolerances are non-accumulating; change
MSOP pin-spacing dimensions and tolerance accordingly.
IL600A Series Isolators
17
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
Datasheet Limitations
The information and data provided in datasheets shall define the specification of the product as agreed between NVE and its customer, unless NVE and
customer have explicitly agreed otherwise in writing. All specifications are based on NVE test protocols. In no event however, shall an agreement be
valid in which the NVE product is deemed to offer functions and qualities beyond those described in the datasheet.
Limited Warranty and Liability
Information in this document is believed to be accurate and reliable. However, NVE does not give any representations or warranties, expressed or
implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information.
In no event shall NVE be liable for any indirect, incidental, punitive, special or consequential damages (including, without limitation, lost profits, lost
savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on
tort (including negligence), warranty, breach of contract or any other legal theory.
Right to Make Changes
NVE reserves the right to make changes to information published in this document including, without limitation, specifications and product descriptions
at any time and without notice. This document supersedes and replaces all information supplied prior to its publication.
Use in Life-Critical or Safety-Critical Applications
Unless NVE and a customer explicitly agree otherwise in writing, NVE products are not designed, authorized or warranted to be suitable for use in life
support, life-critical or safety-critical devices or equipment. NVE accepts no liability for inclusion or use of NVE products in such applications and such
inclusion or use is at the customer’s own risk. Should the customer use NVE products for such application whether authorized by NVE or not, the
customer shall indemnify and hold NVE harmless against all claims and damages.
Applications
Applications described in this datasheet are illustrative only. NVE makes no representation or warranty that such applications will be suitable for the
specified use without further testing or modification.
Customers are responsible for the design and operation of their applications and products using NVE products, and NVE accepts no liability for any
assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the NVE product is suitable and fit for
the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customers. Customers should
provide appropriate design and operating safeguards to minimize the risks associated with their applications and products.
NVE does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s
applications or products, or the application or use by customer’s third party customers. The customer is responsible for all necessary testing for the
customer’s applications and products using NVE products in order to avoid a default of the applications and the products or of the application or use by
customer’s third party customers. NVE accepts no liability in this respect.
Limiting Values
Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the
device. Limiting values are stress ratings only and operation of the device at these or any other conditions above those given in the recommended
operating conditions of the datasheet is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the
quality and reliability of the device.
Terms and Conditions of Sale
In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. NVE hereby expressly objects to
applying the customer’s general terms and conditions with regard to the purchase of NVE products by customer.
No Offer to Sell or License
Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication
of any license under any copyrights, patents or other industrial or intellectual property rights.
Export Control
This document as well as the items described herein may be subject to export control regulations. Export might require a prior authorization from national
authorities.
Automotive Qualified Products
Unless the datasheet expressly states that a specific NVE product is automotive qualified, the product is not suitable for automotive use. It is neither
qualified nor tested in accordance with automotive testing or application requirements. NVE accepts no liability for inclusion or use of non-automotive
qualified products in automotive equipment or applications.
In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall
use the product without NVE’s warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the
product for automotive applications beyond NVE’s specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies
NVE for any liability, damages or failed product claims resulting from customer design and use of the product for automotive applications beyond NVE’s
standard warranty and NVE’s product specifications.
IL600A Series Isolators
18
NVE Corporation 11409 Valley View Road, Eden Prairie, MN 55344-3617 Phone: (952) 829-9217 Fax: (952) 829-9189 www.IsoLoop.com ©NVE Corporation
An ISO 9001 Certified Company
NVE Corporation
11409 Valley View Road
Eden Prairie, MN 55344-3617 USA
Telephone: (952) 829-9217
Fax: (952) 829-9189
www.nve.com
e-mail: iso-info@nve.com
©NVE Corporation
All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner.
ISB-DS-001-IL600A-Z
November 2013