DX-500R Accessory and I/O Configuration Reference Guide (Website) STANDARD ACCESSORIES FTKIT Air Hose Fitting 1700-0014 Power Adapter TSD800-6 7045-9020 Foot Switch OPTIONAL ACCESSORIES DX-ECABLE BLACK WHITE ENCODER B+ ENCODER A+ GND ENCODER B+ ENCODER A+ +5VDC +5VDC MOTOR + MOTOR GND BACK VIEW OF CABLE (FRONT VIEW FROM CONTROLLER) SPARE PARTS Part Number 2900-0015 7049-9010 TSD500-30 TSD650-21 535 TSD1121-23 TSD1135-26 Description LCD, 20 x 4 with Back Light PCBA, DX-500 Pressure Regulator, 0-100 psi Solenoid Valve Coupler, Panel mount Knob, Pressure Regulator 6 Pin Din Socket I/O Configuration and End of Cycle Switch Upon completion of a dispense cycle, an open collector circuit closes and remains closed until the next dispense cycle. This circuit can be used to signal back to a host computer, start another device in sequence, or drive any other operations that need to be tied to the completion of the dispense cycle. Upon closure, (end of dispense cycle), power from an external source is allowed to pass through the circuit to operate a 5 to 24 VDC load. Power consumption must not exceed 250 mA. The load could be a relay, solenoid, counter, LED, or any device that will operate within a 5 to 24 VDC range and a maximum of 250 mA. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: OK International: 535 7049-9010 DX-ECABLE TSD1135-26