Pressure Sensor Series PSE530 How to Order PSE53 0 M5 Pressure sensing range 0 1 2 3 High pressure [0 to 1 MPa] Vacuum [0 to -101 kPa] Low pressure [0 to 101 kPa] Compound pressure [-101 to 101 kPa] Option Sensor cable (3 m) Port size M5 Without cable Nil L M5 x 0.8 Option Sensor cable (3 m) + Connector (1 pc.) When only optional parts are required, order using the part numbers listed below. Connector ZS-26-E 4 pcs. per set Sensor cable ZS-26-F Cable length: 3 m Connector + Sensor cable ZS-26-G The connector is not connected to the cable at the time of shipment. 4321 Note Part no. CL Description Connector Note) At the factory, the connector is not connected to the cable, but packed together with it for shipment. Cable length: 3 m Specifications Model Rated pressure range Proof pressure PSE530-M5 PSE531-M5 PSE532-M5 PSE533-M5 0 to 1 MPa 0 to -101 kPa 0 to 101 kPa -101 to 101 kPa 1.5 MPa 500kPa Air/Non-corrosive gas Fluid Power supply voltage 12 to 24 VDC (Ripple 10% or less) Current consumption 15 mA or less Output specification Analog output (1 to 5 V, Output impedance: Approx. 1 k) Accuracy 2% F.S. or less (Within rated pressure range, Ambient temperature 25 3C) Linearity 1% F.S. or less Repeatability Power supply voltage effect Resistance Enclosure 1% F.S. or less 1% F.S. or less based on the analog output at 18 V ranging from 12 to 24 VDC IP40 Temperature range 0 to 50C; Stored: -10 to 70C (No freezing or condensation) Withstand voltage 1000 VAC, 50/60Hz for 1 minute between external terminals and case Insulation resistance 5 M between external terminals and case (at 50 VDC) Vibration resistance 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized) Impact resistance Temperature characteristics (Based on 25C) 980 m/s2 in X, Y, Z directions, 3 times each (De-energized) 2% F.S. or less based on the analog output value at 25C from a range of 0 to 50C Port size M5 x 0.8 Material Body: Stainless steel Grade 303, Internal enclosure: PPE; Pressure sensor: Silicon; O-ring: NBR Sensor cable/Option 16-3-4 Halogen-free heavy-duty cord, o2.7, 0.15 mm2, 3 cores, 3 m Pressure Sensor Series PSE530 Internal Circuit DC (+) Power supply Brown DC (-) GND Blue Analog output (1 to 5 V) Black Main circuit Brown Sensor cable color Black Blue 12 to 24 VDC Load ZSE ISE PSE Dimensions Z I PSE53-M5 SE3 PS 29.4 27.2 0.5 M5 x 0.8 Z I o2 .5 3.4 Pressure port SE 12 3 o1 5.4 o12 o7.2 ZSP ISA2 3 IS 12 4 5 ZSM 5.5 PF2 With sensor cable o2.7 o10.4 IF Data 16-3-5 Series PSE Specific Product Precautions 1 Be sure to read before handling. Controller Pressure Sensor Handling Handling 1. Do not drop, bump, or apply excessive impacts (980 m/s2) while handling. Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to a malfunction. 2. The tensile strength of the cord is 23 N. Applying a greater pulling force on it can cause a malfunction. When handling, hold the body of the sensor--do not dangle it from the cord. 3. Do not exceed the screw-in torque of 3.5 Nm when installing piping. Exceeding this value may cause malfunctioning of the sensor. 4. Do not use pressure sensors with corrosive and/or inflammable gases or liquids. 5. Connecting the sensor cable (Option) 1. Do not drop, bump, or apply excessive impacts (1000 m/s2) while handling. Although the body of the controller case may not be damaged, the inside of the controller could be damaged and cause a malfunction. 2. The tensile strength of the power supply/output connection cable is 50 N; that of the pressure sensor lead wire with connector is 25 N. Applying a greater pulling force than the applicable specified tensile strength to either of these components can lead to a malfunction. When handling, hold the body of the controller--do not dangle it from the cord. Warning Warning Hold the female connector of the sensor cable with your fingers and carefully insert it into the connector. Sensor Male connector Female connector A connector cover is provided as part of the cable assembly (see the figure below). It is designed to keep the female connector from slipping out of the sensor. To lock the connector cover in place, first make sure it is facing in the right direction as you slip it over the female connector, then lock it to the sensor body by turning it clockwise. To remove the cover, first unlock it by turning it counterclockwise, then pull back on it. To remove the female connector, grab it with your fingers and pull back on it. Do not pull on the cable. Lock Sensor Connector cover Unlock Operating Environment Warning 1. The pressure sensors are CE marked; however, they are not equipped with surge protection against lightning. Lightning surge countermeasures should be applied directly to system components as necessary. 2. The pressure sensors do not have an explosion proof rating. Never use pressure sensors in the presence of inflammable or explosive gases. ZSE ISE PSE Z I SE3 PS Z I SE 12 ZSP ISA2 Connection Warning IS 1. Incorrect wiring can damage the switch and cause a malfunction or erroneous switch output. Connections should be done while the power is turned off. 2. Do not attempt to insert or pull the pressure sensor or its connector when the power is on. Switch output may malfunction. 3. Wire separately from power lines and high voltage lines, avoiding wiring in the same conduit with these lines. Malfunctions may occur due to noise from these other lines. 4. If a commercial switching regulator is used, make sure that the F.G. terminal is grounded. Operating Environment Warning 1. Our multi-channel pressure sensor controllers are CE marked; however, they are not equipped with surge protection against lightning. Lightning surge countermeasures should be applied directly to system components as necessary. 2. Our multi-channel pressure sensor controllers do not have an explosion proof rating. Never use pressure sensors in the presence of inflammable or explosive gases. 3. Enclosure "IP65" applies only to the front face of the panel when mounting. Do not use in an environment where oil splashing or spraying are anticipated. 16-3-19 ZSM PF2 IF Data Series PSE Specific Product Precautions 2 Be sure to read before handling. Mounting Wiring Caution Caution The front face of the panel mount conforms to IP65 (IP40 when using the 48 conversion adapter); however, there is a possibility of liquid filtration if the panel mount adapter is not installed securely and properly. Securely fix the adaptor with screws as shown below. 1. Connecting sensor cable and connector (ZS-26-E) * Cut the sensor cable as shown below. * Insert each lead wire into the corresponding connector number by following the chart provided below. Connector no. Standard Front protective cover (ZS-26-01) Panel mount (ZS-26-B) 2-M3 x 8L Tighten screws 1/4 to 1/2 turn after the heads are flush with the panel. When using 48 conversion adapter Core wire color of sensor cable 1 Brown (DC+) 2 Black (Analog output) 3 Blue (DC-) 4 N.C. 20 mm or more Brown Black Blue N.C. 1 2 3 4 * Make sure that the number of connector and the core wire color match. After verifying that the wires are inserted all the way, temporarily hold the connector down manually. * Using pliers, snap A into B as shown below so that there is no gap between A and B, and secure the connector. * The A and B portion of the sensor connector are already tacked down temporarily at the time of shipment. Do not snap the A portion in place before inserting the cable. Note that the connector cannot be taken apart to be reused once it is crimped. Use a new sensor connector in case wiring or the snapping of A into B are done incorrectly. 48 conversion adapter (ZS-26-D) B 4321 A 432 1 432 1 Verify from the top side of A that the lead wires are inserted completely. * To connect the connector to the multi-channel pressure sensor, push the connector with its A portion facing toward you into the socket until it clicks as shown below. * To remove the connector, pull it straight out while applying pressure to the fingers on both sides. 1 2 3 4 Sensor connector port Power supply/Output connector 2. Connecting power supply/output connection cable * To connect the power supply/output connection cable to the controller, insert the cable connector with the C part facing down until it clicks. C 2m 16-3-20 Series PSE Specific Product Precautions 3 Be sure to read before handling. Wiring Caution 3. Connecting to other series ZSE ISE * Any pressure sensor (SW) can be connected as long as it generates analog output (1 to 5 V) signal. However, the pressure range must match. * SMC pressure sensors, Series PSE510 & PSE520, are also connectable. * When connecting to pressure sensors other than the Series PSE530, connector types will vary depending on the wire core size of the cable and the outside diameter of the insulation cover. Refer to the table provided below. Connector part no. ZS-26-E ZS-26-E-1 ZS-26-E-2 ZS-26-E-3 PSE Z I PS Z I Insulation Sensor part no. cover Wire core size O.D. AWG24-26 (0.14 to 0.2 mm2) o1.0 to 1.4 PSE510, PSE530 AWG24-26 (0.14 to 0.2 mm2) o1.4 to 2.0 AWG20-22 (0.3 to 0.5 mm2) o1.0 to 1.4 PSE521 AWG20-22 (0.3 to 0.5 mm2) o1.4 to 2.0 PSE520 ISA2 IS ZSM PF2 1 2 3 4 IF Data F.G. Connect the shielding wire to the frame ground (F.G.) or F.G. terminal. ( There is no shielding wire for Series PSE510 & PSE530. SE 12 ZSP * Refer to the following diagram for connecting Series PSE520 to the connector. Brown Black Blue N.C. SE3 ) Regulating Pressure Range & Rated Pressure Range Caution 1. Regulating pressure range: Refers to allowable pressure range in a pressure setting mode. * Setting range is between P_1(n_1) to P_4(n_4). * For Series PSE200, the regulating pressure range and the setting pressure range that can be displayed are the same. 2. Rated pressure range: Refers to the pressure range that satisfies the product specifications. * Pressure range that satisfies the product specifications (accuracy and linearity) for PSE530. 16-3-21 Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices. Caution : Operator error could result in injury or equipment damage. Warning : Operator error could result in serious injury or loss of life. Danger : In extreme conditions, there is a possible result of serious injury or loss of life. Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems. Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. The expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed. 2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc. 4. Contact SMC if the product is to be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 16-14-3 Common Precautions Be sure to read before handling. For detailed precautions on every series, refer to main text. Selection Warning 1. Confirm the specifications. Products represented in this catalog are designed for use in compressed air appllications only (including vacuum), unless otherwise indicated. Do not use the product outside their design parameters. Please contact SMC when using the products in applications other than compressed air (including vacuum). Mounting Warning 1. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. 4. Use clean air If the compressed air supply is contaminated with chemicals, cynthetic materials, corrosive gas, etc., it may lead to break down or malfunction. Operating Environment Warning 1. Do not use in environments where the product is directly exposed to corrosive gases, chemicals, salt water, water or steam. 2. Do not expose the product to direct sunlight for an extended period of time. 3. Do not use in a place subject to heavy vibrations and/or shocks. 4. Do not mount the product in locations where it is exposed to radiant heat. Maintenance 2. Securing the space for maintenance When installing the products, please allow access for maintenance. 3. Tightening torque When installing the products, please follow the listed torque specifications. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping. Also, when the pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. Air Supply Warning 1. Operating fluid Please consult with SMC when using the product in applications other than compressed air (including vacuum). Regarding products for general fluid, please ask SMC about applicable fluids. 2. Install an air dryer, aftercooler, etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler etc. is recommended. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines. If the drain bowl is difficult to check and remove, it is recommended that a drain bowl with the auto-drain option be installed. For compressed air quality, refer to "Air Preparation Equipment" catalog. 16-14-4 Warning 1. Maintenance procedures are outlined in the operation manual. Not following proper procedures could cause the product to malfunction and could lead to damage to the equipment or machine. 2. Maintenance work If handled improperly, compressed air can be dangerous. Assembly, handling and repair of pneumatic systems should be performed by qualified personnel only. 3. Drain flushing Remove drainage from air filters regularly. (Refer to the specifications.) 4. Shut-down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut of and all residual air pressure is released from the system to be worked on. 5. Start-up after maintenance and inspection Apply operating pressure and power to the equipment and check for proper operation and possible air leaks. If operation is abnormal, please verify product set-up parameters. 6. Do not make any modifications to be product. Do not take the product apart. Quality Assurance Information (ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout the world to use our products with even greater confidence, SMC has obtained certification for international standards "ISO 9001" and "ISO 14001", and created a complete structure for quality assurance and environmental controls. SMC products pursue to meet its customers' expectations while also considering company's contribution in society. SMC's quality control system Make customers our first priority, offering them reliable and friendly service. Produce the highest quality with the participation of all employees. Create new products using the latest technology, and offer the finest products in a timely manner. Quality policies Market research Product planning After service Sales coordination Quality management system ISO 9001 This is an international standard for quality control and quality assurance. SMC has obtained a large number of certifications in Japan and overseas, providing assurance to our customers throughout the world. Quality system education Training of suppliers Research Education Design Training Development Production New product evaluation Reliability design Reliability testing New technical development Process control Inspection, testing, etc. Initial production control Quality control activities Environmental management system ISO 14001 This is an international standard related to environmental management systems and environmental inspections. While promoting environmentally friendly automation technology, SMC is also making diligent efforts to preserve the environment. 16-14-5 SMC Product Conforming to Inter SMC products complying with EN/ISO, CSA/UL standards are supporting CE Mark The CE mark indicates that machines and components meet essential requirements of all the EC Directives applied. It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and components are exported to the member Nations of the EU. Once "A manufacturer himself" declares a product to be safe by means of CE marking (declaration of conformity by manufacturer), free distribution inside the member Nations of the EU is permissible. CE Mark SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in accordance with CETOP (European hydraulics and pneumatics committee) guide lines. As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark, Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg EC Directives and Pneumatic Components * Machinery Directive The Machinery Directive contains essential health and safety requirements for machinery, as applied to industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic equipment is not specified in Machinery Directive. However, the use of SMC products that are certified as conforming to EN Standards, allows customers to simplify preparation work of the Technical Construction File required for a Declaration of Conformity. * Electromagnetic Compatibility (EMC) Directive The EMC Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission). * Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. * Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L. Such vessels require EC type examination and then CE marking. 16-14-6 SMC Product Conforming to International Standards national Standards you to comply with EC directives and CSA/UL standards. Mark of compliance for CSA/UL Mark of compliance for CSA CSA Standards & UL Standards UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with electric products. Both UL and CSA standards are acknowledged in North America as the first class certifying body. They have a long experience and ability for issuing product safety certificate. Products approved by CSA or UL standards are accepted in most states and governments beyond question. Since CSA is a test certifying body as the National Recognized Testing Laboratory (NRTL) within the jurisdiction of Occupational Safety and Health Administration (OSHA), SMC was tested for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards. The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards. TSSA (MCCR) Registration Products TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation. Products conforming to CE Standard With CE symbol for simple visual recognition In this catalog each accredited product series is indicated with a CE mark symbol. However, in some cases, every available models may not meet CE compliance. Please visit our web site for the latest selection of available models with CE mark. http://www.smcworld.com 16-14-7 SMC's Global Service Network America Europe U.S.A. SMC Corporation of America 3011 North Franklin Road Indianapolis, IN 46226, U.S.A. TEL: 317-899-4440 FAX: 317-899-3102 U.K. SMC Pneumatics (U.K.) Ltd. Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K. TEL: 01908-563888 FAX: 01908-561185 CANADA SMC Pneumatics (Canada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 905-812-0400 FAX: 905-812-8686 GERMANY SMC Pneumatik GmbH Boschring 13-15 D-63329 Egelsbach, Germany TEL: 06103-4020 FAX: 06103-402139 MEXICO SMC Corporation (Mexico), S.A. DE C.V. Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 ITALY SMC Italia S.p.A. Via Garibaldi 62 I-20061 Carugate Milano, Italy TEL: 02-9271365 FAX: 02-9271365 CHILE SMC Pneumatics (Chile) S.A. Av. La Montana 1,115 km. 16,5 P. Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 ARGENTINA SMC Argentina S.A. Teodoro Garcia 3860 (1427) Buenos Aires, Argentina TEL: 011-4555-5762 FAX: 011-4555-5762 BOLIVIA SMC Pneumatics Bolivia S.R.L. Avenida Beni Numero 4665 Santa Cruz de la Sierra-Casilla de Correo 2281, Bolivia TEL: 591-3-3428383 FAX: 591-3-3449900 VENEZUELA SMC Neumatica Venezuela S.A. Apartado 40152, Avenida Nueva Granada, Edificio Wanlac, Local 5, Caracas 1040-A, Venezuela TEL: 2-632-1310 FAX: 2-632-3871 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 SWEDEN SMC Pneumatics Sweden AB Ekhagsvagen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 SWITZERLAND SMC Pneumatik AG Dorfstrasse 7, Postfach 117, CH-8484 Weisslingen, Switzerland TEL: 052-396-3131 FAX: 052-396-3191 AUSTRIA SMC Pneumatik GmbH (Austria) Girakstrasse 8, A-2100 Korneuburg, Austria TEL: 0-2262-6228-0 FAX: 0-2262-62285 SPAIN SMC Espana, S.A. Zuazobidea 14 Pol. Ind. Jundiz 01015 Vitoria, Spain TEL: 945-184-100 FAX: 945-184-510 PERU (Distributor) IMPECO Automatizacion Industrial S.A. AV. Canevaro 752, Lince, Lima, Peru TEL: 1-471-6002 FAX: 1-471-0935 IRELAND SMC Pneumatics (Ireland) Ltd. 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland TEL: 01-403-9000 FAX: 01-466-0385 URUGUAY (Distributor) BAKO S.A. Galicia 1650 esq. Gaboto C.P. 11200, Montevideo, Uruguay TEL: 2-401-6603 FAX: 2-409-4306 NETHERLANDS (Associated company) SMC Pneumatics BV De Ruyterkade 120, NL-1011 AB Amsterdam, Netherlands TEL: 020-5318888 FAX: 020-5318880 BRAZIL SMC Pneumaticos Do Brasil Ltda. Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P. CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogota, Colombia TEL: 1-424-9240 FAX: 1-424-9260 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 16-14-20 SMC's Global Service Network Europe Oceania/Asia FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd. 14-18 Hudson Avenue Castle Hill NSW 2154, Australia TEL: 02-9354-8222 FAX: 02-9894-5719 NORWAY SMC Pneumatics Norway A/S Vollsveien 13C, Granfoss Naeringspark N-1366 LYSAKER, Norway TEL: 67-12-90-20 FAX: 67-12-90-21 NEW ZEALAND SMC Pneumatics (New Zealand) Ltd. 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 09-573-7007 FAX: 09-573-7002 BELGIUM (Distributor) SMC Pneumatics N.V./S.A. Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland TEL: 022-548-5085 FAX: 022-548-5087 HONG KONG SMC Pneumatics (Hong Kong) Ltd. 29/F, Clifford Centre, 778-784 Cheung, Sha Wan Road, Lai Chi Kok, Kowloon, Hong Kong TEL: 2744-0121 FAX: 2785-1314 TURKEY (Distributor) Entek Pnomatik San.ve Tic. Ltd. Sti Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Turkiye TEL: 0212-221-1512 FAX: 0212-221-1519 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St. Petersburg 199004, Russia TEL: 812-118-5445 FAX: 812-118-5449 CZECH SMC Industrial Automation CZ s.r.o. Hudcova 78a, CZ-61200 Brno, Czech Republic TEL: 05-4121-8034 FAX: 05-4121-8034 HUNGARY SMC Hungary Ipari Automatizalasi kft. Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 ROMANIA SMC Romania S.r.l. Str. Frunzei, Nr. 29, Sector 2, Bucharest, Romania TEL: 01-3205111 FAX: 01-3261489 SLOVAKIA SMC Priemyselna automatizacia, s.r.o Nova 3, SK-83103 Bratislava TEL: 02-4445-6725 FAX: 02-4445-6028 SLOVENIA SMC Industrijska Avtomatilca d.o.o. Grajski trg 15, SLO- 8360 Zuzemberk, Slovenia TEL: 07388-5240 FAX: 07388-5249 SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd. P.O.Box 240 Paardeneiland 7420 South Africa TEL: 021-511-7021 FAX: 021-511-4456 EGYPT (Distributor) Saadani Trading & Ind. Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 PHILIPPINES SHOKETSU SMC Corporation Unit 201 Common Goal Tower, Madrigal Business Park, Ayala Alabang Muntinlupa, Philippines TEL: 02-8090565 FAX: 02-8090586 MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, Batu 3 40000 Shah Alam Selangor, Malaysia TEL: 03-56350590 FAX: 03-56350602 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 CHINA SMC (China) Co., Ltd. 7 Wan Yuan St. Beijing Economic & Technological Development Zone 100176, China TEL: 010-67882111 FAX: 010-67881837 THAILAND SMC Thailand Ltd. 134/6 Moo 5, Tiwanon Road, Bangkadi, Amphur Muang, Patumthani 12000, Thailand TEL: 02-963-7099 FAX: 02-501-2937 INDIA SMC Pneumatics (India) Pvt. Ltd. D-107 to 112, Phase-2, Extension, Noida, Dist. Gautaim Budh Nagar, U.P. 201 305, India TEL: (0120)-4568730 FAX: 0120-4568933 INDONESIA (Distributor) P.T. Riyadi Putera Makmur Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia TEL: 021-625 5548 FAX: 021-625 5888 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O. Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 16-14-21