How to Order
4 3 2 1
Pressure Sensor
Series PSE530
Option
PSE53 0 M5
Nil
L
CL
Option
Without cable
0
1
2
3
Pressure sensing range
High pressure [0 to 1 MPa]
Vacuum [0 to –101 kPa]
Low pressure [0 to 101 kPa]
Compound pressure [–101 to 101 kPa]
M5
Port size
M5 x 0.8
Sensor cable (3 m)
Sensor cable (3 m) + Connector (1 pc.)
Description Part no.
ZS-26-E
ZS-26-F
ZS-26-G
Note
4 pcs. per set
Cable length: 3 m
Cable length: 3 m
Connector
Sensor cable
Connector +
Sensor cable
Specifications
Model PSE530-M5
0 to 1 MPa
1.5 MPa
PSE531-M5
0 to –101 kPa
Air/Non-corrosive gas
12 to 24 VDC (Ripple ±10% or less)
15 mA or less
Analog output (1 to 5 V, Output impedance: Approx. 1 k)
±2% F.S. or less (Within rated pressure range, Ambient temperature 25° ±3°C)
±1% F.S. or less
±1% F.S. or less
±1% F.S. or less based on the analog output at 18 V ranging from 12 to 24 VDC
IP40
0° to 50°C; Stored: –10° to 70°C (No freezing or condensation)
1000 VAC, 50/60Hz for 1 minute between external terminals and case
5 M between external terminals and case (at 50 VDC)
10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s
2
acceleration, in X, Y, Z directions, for 2 hours each (De-energized)
980 m/s2 in X, Y, Z directions, 3 times each (De-energized)
±2% F.S. or less based on the analog output value at 25°C from a range of 0° to 50°C
M5 x 0.8
Body: Stainless steel Grade 303, Internal enclosure: PPE; Pressure sensor: Silicon; O-ring: NBR
Halogen-free heavy-duty cord, ø2.7, 0.15 mm2, 3 cores, 3 m
PSE533-M5
–101 to 101 kPa
PSE532-M5
0 to 101 kPa
500kPa
Rated pressure range
Proof pressure
Fluid
Power supply voltage
Current consumption
Output specification
Accuracy
Linearity
Repeatability
Power supply voltage effect
Enclosure
Temperature range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Temperature characteristics (Based on 25°C)
Port size
Material
Sensor cable/Option
Resistance
Connector
When only optional parts are required, order using the part
numbers listed below.
The connector is not connected to
the cable at the time of shipment.
Note) At the factory, the connector is not connected to the
cable, but packed together with it for shipment.
16-3-4
Internal Circuit
Dimensions
PSE53-M5
Sensor cable color
Brown
Blue
Black
DC (+) Power supply
DC (–) GND
Analog output (1 to 5 V)
With sensor cable
Main circuit
Load
Brown
Black
Blue
12 to 24 VDC
5 5.5
4
3
3.4
0.5
29.4
27.2
12
5.4
M5 x 0.8
Pressure port
ø2.5
ø13
ø12
ø7.2
ø2.7
ø10.4
16-3-5
ZSE
ISE
PSE
Z
ISE3
PS
Z
ISE 1
2
ZSP
ISA2
IS
ZSM
PF2
IF
Data
Series PSE530
Pressure Sensor
1. Do not drop, bump, or apply excessive impacts (980
m/s2) while handling. Although the body of the
sensor may not be damaged, the inside of the
sensor could be damaged and lead to a
malfunction.
2. The tensile strength of the cord is 23 N. Applying a
greater pulling force on it can cause a malfunction.
When handling, hold the body of the sensor—do
not dangle it from the cord.
3. Do not exceed the screw-in torque of 3.5 Nm when
installing piping. Exceeding this value may cause
malfunctioning of the sensor.
4. Do not use pressure sensors with corrosive and/or
inflammable gases or liquids.
5. Connecting the sensor cable (Option)
Hold the female connector of the sensor cable with your
fingers and carefully insert it into the connector.
Warning
Handling
Pressure Sensor
1. Do not drop, bump, or apply excessive impacts
(1000 m/s2) while handling. Although the body of
the controller case may not be damaged, the inside
of the controller could be damaged and cause a
malfunction.
2. The tensile strength of the power supply/output
connection cable is 50 N; that of the pressure
sensor lead wire with connector is 25 N. Applying a
greater pulling force than the applicable specified
tensile strength to either of these components can
lead to a malfunction. When handling, hold the
body of the controller—do not dangle it from the
cord.
Warning
Handling
1. Incorrect wiring can damage the switch and cause
a malfunction or erroneous switch output.
Connections should be done while the power is
turned off.
2. Do not attempt to insert or pull the pressure sensor
or its connector when the power is on. Switch
output may malfunction.
3. Wire separately from power lines and high voltage
lines, avoiding wiring in the same conduit with
these lines. Malfunctions may occur due to noise
from these other lines.
4. If a commercial switching regulator is used, make
sure that the F.G. terminal is grounded.
Connection
Warning
1. Our multi-channel pressure sensor controllers are
CE marked; however, they are not equipped with
surge protection against lightning. Lightning surge
countermeasures should be applied directly to
system components as necessary.
2. Our multi-channel pressure sensor controllers do
not have an explosion proof rating. Never use
pressure sensors in the presence of inflammable or
explosive gases.
3. Enclosure “IP65” applies only to the front face of
the panel when mounting. Do not use in an
environment where oil splashing or spraying are
anticipated.
Operating Environment
Warning
1. The pressure sensors are CE marked; however, they
are not equipped with surge protection against
lightning. Lightning surge countermeasures should
be applied directly to system components as
necessary.
2. The pressure sensors do not have an explosion
proof rating. Never use pressure sensors in the
presence of inflammable or explosive gases.
Operating Environment
Warning
Controller
Sensor
Male connector
Female connector
Unlock
Lock
Sensor
Connector cover
A connector cover is provided as part of the cable assembly
(see the figure below). It is designed to keep the female
connector from slipping out of the sensor. To lock the connector
cover in place, first make sure it is facing in the right direction
as you slip it over the female connector, then lock it to the
sensor body by turning it clockwise. To remove the cover, first
unlock it by turning it counterclockwise, then pull back on it. To
remove the female connector, grab it with your fingers and pull
back on it. Do not pull on the cable.
Series PSE
Specific Product Precautions 1
Be sure to read before handling.
16-3-19
ZSE
ISE
PSE
Z
ISE3
PS
Z
ISE 1
2
ZSP
ISA2
IS
ZSM
PF2
IF
Data
Mounting Wiring
Tighten screws 1/4 to 1/2 turn after the heads are flush with the panel.
Standard
When using 48 conversion adapter
48 conversion adapter
(ZS-26-D)
2-M3 x 8L
Front protective cover
(ZS-26-01) Panel mount
(ZS-26-B)
Caution
The front face of the panel mount conforms to IP65
(IP40 when using the 48 conversion adapter);
however, there is a possibility of liquid filtration if the
panel mount adapter is not installed securely and
properly. Securely fix the adaptor with screws as
shown below.
1. Connecting sensor cable and connector (ZS-26-E)
• Cut the sensor cable as shown below.
• Insert each lead wire into the corresponding connector number
by following the chart provided below.
Core wire color
of sensor cable
Brown (DC+)
Black (Analog output)
Blue (DC–)
N.C.
Connector
no.
1
2
3
4
Power supply/Output connector
Sensor connector port
4321
20 mm or more
4 3 2 1
4 3 2 1
4 3 2 1
B
A
2 m
C
Caution
• Make sure that the number of connector and the core wire
color match. After verifying that the wires are inserted all the
way, temporarily hold the connector down manually.
• Using pliers, snap A into B as shown below so that there is no
gap between A and B, and secure the connector.
The A and B portion of the sensor connector are already tacked
down temporarily at the time of shipment. Do not snap the A
portion in place before inserting the cable. Note that the
connector cannot be taken apart to be reused once it is
crimped. Use a new sensor connector in case wiring or the
snapping of A into B are done incorrectly.
To connect the connector to the multi-channel pressure sensor,
push the connector with its A portion facing toward you into the
socket until it clicks as shown below.
To remove the connector, pull it straight out while applying
pressure to the fingers on both sides.
2. Connecting power supply/output connection cable
To connect the power supply/output connection cable to the
controller, insert the cable connector with the C part facing
down until it clicks.
Brown
Black
Blue
N.C.
1
2
3
4
Ver ify from the top side of
A that the lead wires are
inserted completely.
Series PSE
Specific Product Precautions 2
Be sure to read before handling.
16-3-20
Wiring
Caution
3. Connecting to other series
• Any pressure sensor (SW) can be connected as long as it
generates analog output (1 to 5 V) signal. However, the
pressure range must match.
• SMC pressure sensors, Series PSE510 & PSE520, are also
connectable.
When connecting to pressure sensors other than the Series
PSE530, connector types will vary depending on the wire core
size of the cable and the outside diameter of the insulation
cover. Refer to the table provided below.
Refer to the following diagram for connecting Series PSE520 to
the connector.
ZS-26-E
ZS-26-E-1
ZS-26-E-2
ZS-26-E-3
Connector
part no. Wire core size
AWG24-26 (0.14 to 0.2 mm2)
AWG24-26 (0.14 to 0.2 mm2)
AWG20-22 (0.3 to 0.5 mm2)
AWG20-22 (0.3 to 0.5 mm2)
Insulation
cover
O.D.
ø1.0 to 1.4
ø1.4 to 2.0
ø1.0 to 1.4
ø1.4 to 2.0
Sensor part no.
PSE510, PSE530
PSE521
PSE520
Brown
Black
Blue
N.C.
1
2
3
4
F. G .
Regulating Pressure Range & Rated Pressure Range
1. Regulating pressure range: Refers to allowable
pressure range in a pressure setting mode.
• Setting range is between P_1(n_1) to P_4(n_4).
For Series PSE200, the regulating pressure range and the
setting pressure range that can be displayed are the same.
2. Rated pressure range: Refers to the pressure range
that satisfies the product specifications.
Pressure range that satisfies the product specifications
(accuracy and linearity) for PSE530.
Caution
( )
There is no shielding wire for
Series PSE510 & PSE530.
Connect the shielding wire to
the frame ground (F.G.) or
F.G. terminal.
Series PSE
Specific Product Precautions 3
Be sure to read before handling.
16-3-21
ZSE
ISE
PSE
Z
ISE3
PS
Z
ISE 1
2
ZSP
ISA2
IS
ZSM
PF2
IF
Data
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by labels of
"Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1),
JIS B 8370
Note 2) and other safety practices.
1. The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements. The expected performance and safety assurance will be the responsibility of the
person who has determined the compatibility of the system. This person should continuously review
the suitability of all items specified, referring to the latest catalog information with a view to giving due
consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery
and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to
prevent falling or runaway of the driver objects have been confirmed.
2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply
pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston
rod, etc.
4. Contact SMC if the product is to be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles,
medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and
brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.
Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems.
Note 2) JIS B 8370: General Rules for Pneumatic Equipment
Warning
Caution : Operator error could result in injury or equipment damage.
Warning
: Operator error could result in serious injury or loss of life.
Danger : In extreme conditions, there is a possible result of serious injury or loss of life.
16-14-3
1. Confirm the specifications.
Products represented in this catalog are designed for use in
compressed air appllications only (including vacuum), unless
otherwise indicated.
Do not use the product outside their design parameters.
Please contact SMC when using the products in applications
other than compressed air (including vacuum).
4. Use clean air
If the compressed air supply is contaminated with chemicals,
cynthetic materials, corrosive gas, etc., it may lead to break
down or malfunction.
Selection
Mounting
Piping
Air Supply
Maintenance
Operating Environment
Warning
1. Instruction manual
Install the products and operate them only after reading the
instruction manual carefully and understanding its contents.
Also keep the manual where it can be referred to as
necessary.
2. Securing the space for maintenance
When installing the products, please allow access for
maintenance.
3. Tightening torque
When installing the products, please follow the listed torque
specifications.
Warning
1. Do not use in environments where the product
is directly exposed to corrosive gases,
chemicals, salt water, water or steam.
2. Do not expose the product to direct sunlight
for an extended period of time.
3. Do not use in a place subject to heavy
vibrations and/or shocks.
4. Do not mount the product in locations where it
is exposed to radiant heat.
Warning
1. Maintenance procedures are outlined in the
operation manual.
Not following proper procedures could cause the product to
malfunction and could lead to damage to the equipment or
machine.
2. Maintenance work
If handled improperly, compressed air can be dangerous.
Assembly, handling and repair of pneumatic systems should
be performed by qualified personnel only.
3. Drain flushing
Remove drainage from air filters regularly. (Refer to the
specifications.)
4. Shut-down before maintenance
Before attempting any kind of maintenance make sure the
supply pressure is shut of and all residual air pressure is
released from the system to be worked on.
5. Start-up after maintenance and inspection
Apply operating pressure and power to the equipment and
check for proper operation and possible air leaks. If operation
is abnormal, please verify product set-up parameters.
6. Do not make any modifications to be product.
Do not take the product apart.
Warning
1. Before piping
Make sure that all debris, cutting oil, dust, etc, are removed
from the piping.
2. Wrapping of pipe tape
When screwing piping or fittings into ports, ensure that chips
from the pipe threads or sealing material do not get inside the
piping. Also, when the pipe tape is used, leave 1.5 to 2 thread
ridges exposed at the end of the threads.
Caution
1. Operating fluid
Please consult with SMC when using the product in
applications other than compressed air (including vacuum).
Regarding products for general fluid, please ask SMC about
applicable fluids.
2. Install an air dryer, aftercooler, etc.
Excessive condensate in a compressed air system may cause
valves and other pneumatic equipment to malfunction.
Installation of an air dryer, after cooler etc. is recommended.
3. Drain flushing
If condensate in the drain bowl is not emptied on a regular
basis, the bowl will over flow and allow the condensate to
enter the compressed air lines.
If the drain bowl is difficult to check and remove, it is
recommended that a drain bowl with the auto-drain option be
installed.
For compressed air quality, refer to “Air Preparation
Equipment” catalog.
Warning
Common Precautions
Be sure to read before handling.
For detailed precautions on every series, refer to main text.
16-14-4
Quality Assurance Information
(ISO 9001, ISO 14001)
Reliable quality of products in the global market
To enable our customers throughout
the world to use our products with
even greater confidence, SMC has
obtained certification for international
standards “ISO 9001” and “ISO
14001”, and created a complete
structure for quality assurance and
environmental controls. SMC
products pursue to meet its
customers’ expectations while also
considering company’s contribution in
society.
This is an international standard for quality control
and quality assurance. SMC has obtained a large
number of certifications in Japan and overseas,
providing assurance to our customers throughout
the world.
Quality management system
ISO 9001
This is an international standard related to
environmental management systems and
environmental inspections. While promoting
environmentally friendly automation technology,
SMC is also making diligent efforts to preserve
the environment.
Environmental management system
ISO 14001
Sales coordination
Production
Make customers our
first priority, offering
them reliable and
friendly service.
Market research
Product planning
After service
Process control
Inspection, testing, etc.
Initial production control
Quality system
education
Training of
suppliers
New product evaluation
Reliability design
Reliability testing
New technical
development
Education
Training
Research
Design
Development
Produce the highest
quality with the
participation of all
employees.
Create new
products using the
latest technology,
and offer the finest
products in a
timely manner.
SMC’s quality control system
Quality policies
Quality control activities
16-14-5
CE Mark
SMC Product Conforming to Inter
SMC products complying with EN/ISO, CSA/UL standards are supporting
The CE mark indicates that machines and components meet essential requirements of all the EC Directives
applied.
It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and
components are exported to the member Nations of the EU.
Once “A manufacturer himself” declares a product to be safe by means of CE marking (declaration of
conformity by manufacturer), free distribution inside the member Nations of the EU is permissible.
CE Mark
SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in
accordance with CETOP (European hydraulics and pneumatics committee) guide lines.
As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation
Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark,
Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg
EC Directives and Pneumatic Components
• Machinery Directive
The Machinery Directive contains essential health and safety requirements for machinery, as applied to
industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic
equipment is not specified in Machinery Directive. However, the use of SMC products that are certified as
conforming to EN Standards, allows customers to simplify preparation work of the Technical Construction File
required for a Declaration of Conformity.
Electromagnetic Compatibility (EMC) Directive
The EMC Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic
interference or whose function may be compromised by electromagnetic interference is required to be immune
to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).
• Low Voltage Directive
This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC
operating voltage, and require electrical safety measures to be introduced.
• Simple Pressure Vessels Directive
This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V)
exceed 50 bar/L. Such vessels require EC type examination and then CE marking.
16-14-6
http://www.smcworld.com
you to comply with EC directives and CSA/UL standards.
CSA Standards & UL Standards
UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric
products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with
electric products. Both UL and CSA standards are acknowledged in North America as the first class certifying
body. They have a long experience and ability for issuing product safety certificate. Products approved by CSA
or UL standards are accepted in most states and governments beyond question.
Since CSA is a test certifying body as the National Recognized Testing Laboratory (NRTL) within the
jurisdiction of Occupational Safety and Health Administration (OSHA), SMC was tested for compliance with
CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards.
The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved
by CSA and UL Standards.
TSSA (MCCR) Registration Products
TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi
(0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation.
Products conforming to CE Standard
With CE symbol for simple visual recognition
In this catalog each accredited product series is indicated with a
CE mark symbol. However, in some cases, every available
models may not meet CE compliance. Please visit our web site
for the latest selection of available models with CE mark.
Mark of compliance
for CSA
Mark of compliance
for CSA/UL
national Standards
16-14-7
SMC Product Conforming to International Standards
America Europe
U.S.A. SMC Corporation of America
3011 North Franklin Road Indianapolis, IN 46226, U.S.A.
TEL: 317-899-4440 FAX: 317-899-3102
CANADA SMC Pneumatics (Canada) Ltd.
6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada
TEL: 905-812-0400 FAX: 905-812-8686
MEXICO SMC Corporation (Mexico), S.A. DE C.V.
Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo
C.P. 36100, Silao, Gto., Mexico
TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46
CHILE SMC Pneumatics (Chile) S.A.
Av. La Montaña 1,115 km. 16,5 P. Norte Parque
Industrial Valle Grande, Lampa Santiago, Chile
TEL: 02-270-8600 FAX: 02-270-8601
ARGENTINA SMC Argentina S.A.
Teodoro Garcia 3860 (1427) Buenos Aires, Argentina
TEL: 011-4555-5762 FAX: 011-4555-5762
BOLIVIA SMC Pneumatics Bolivia S.R.L.
Avenida Beni Numero 4665
Santa Cruz de la Sierra-Casilla de Correo 2281, Bolivia
TEL: 591-3-3428383 FAX: 591-3-3449900
VENEZUELA SMC Neumatica Venezuela S.A.
Apartado 40152, Avenida Nueva Granada, Edificio Wanlac,
Local 5, Caracas 1040-A, Venezuela
TEL: 2-632-1310 FAX: 2-632-3871
PERU (Distributor) IMPECO Automatizacion Industrial S.A.
AV. Canevaro 752, Lince, Lima, Peru
TEL: 1-471-6002 FAX: 1-471-0935
URUGUAY (Distributor) BAKO S.A.
Galicia 1650 esq. Gaboto C.P. 11200, Montevideo, Uruguay
TEL: 2-401-6603 FAX: 2-409-4306
BRAZIL SMC Pneumaticos Do Brasil Ltda.
Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P.
CEP: 09950-350, Brasil
TEL: 11-4051-1177 FAX: 11-4071-6636
COLOMBIA (Distributor) Airmatic Ltda.
Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogotá, Colombia
TEL: 1-424-9240 FAX: 1-424-9260
U.K. SMC Pneumatics (U.K.) Ltd.
Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K.
TEL: 01908-563888 FAX: 01908-561185
GERMANY SMC Pneumatik GmbH
Boschring 13-15 D-63329 Egelsbach, Germany
TEL: 06103-4020 FAX: 06103-402139
ITALY SMC Italia S.p.A.
Via Garibaldi 62 I-20061 Carugate Milano, Italy
TEL: 02-9271365 FAX: 02-9271365
FRANCE SMC Pneumatique S.A.
1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600
Marne La Vallee Cedex 3 France
TEL: 01-64-76-10-00 FAX: 01-64-76-10-10
SWEDEN SMC Pneumatics Sweden AB
Ekhagsvägen 29-31, S-141 05 Huddinge, Sweden
TEL: 08-603-07-00 FAX: 08-603-07-10
SWITZERLAND SMC Pneumatik AG
Dorfstrasse 7, Postfach 117, CH-8484 Weisslingen, Switzerland
TEL: 052-396-3131 FAX: 052-396-3191
AUSTRIA SMC Pneumatik GmbH (Austria)
Girakstrasse 8, A-2100 Korneuburg, Austria
TEL: 0-2262-6228-0 FAX: 0-2262-62285
SPAIN SMC España, S.A.
Zuazobidea 14 Pol. Ind. Júndiz 01015 Vitoria, Spain
TEL: 945-184-100 FAX: 945-184-510
IRELAND SMC Pneumatics (Ireland) Ltd.
2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland
TEL: 01-403-9000 FAX: 01-466-0385
NETHERLANDS (Associated company) SMC Pneumatics BV
De Ruyterkade 120, NL-1011 AB Amsterdam, Netherlands
TEL: 020-5318888 FAX: 020-5318880
GREECE (Distributor) S.Parianopoulos S.A.
7, Konstantinoupoleos Street 11855 Athens, Greece
TEL: 01-3426076 FAX: 01-3455578
DENMARK SMC Pneumatik A/S
Knudsminde 4 B DK-8300
Odder, Denmark
TEL: 70252900 FAX: 70252901
SMC’s Global Service Network
16-14-20
Europe
FINLAND SMC Pneumatics Finland OY
PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland
TEL: 09-8595-80 FAX: 09-8595-8595
NORWAY SMC Pneumatics Norway A/S
Vollsveien 13C, Granfoss Næringspark N-1366 LYSAKER, Norway
TEL: 67-12-90-20 FAX: 67-12-90-21
BELGIUM (Distributor) SMC Pneumatics N.V./S.A.
Nijverheidsstraat 20 B-2160 Wommelgem Belguim
TEL: 03-355-1464 FAX: 03-355-1466
POLAND SMC Industrial Automation Polska Sp.z.o.o.
ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland
TEL: 022-548-5085 FAX: 022-548-5087
TURKEY (Distributor) Entek Pnömatik San.ve Tic. Ltd. Sti
Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Türkiye
TEL: 0212-221-1512 FAX: 0212-221-1519
RUSSIA SMC Pneumatik LLC.
36/40 Sredny prospect V.O. St. Petersburg 199004, Russia
TEL: 812-118-5445 FAX: 812-118-5449
CZECH SMC Industrial Automation CZ s.r.o.
Hudcova 78a, CZ-61200 Brno, Czech Republic
TEL: 05-4121-8034 FAX: 05-4121-8034
HUNGARY SMC Hungary Ipari Automatizálási kft.
Budafoki ut 107-113 1117 Budapest
TEL: 01-371-1343 FAX: 01-371-1344
ROMANIA SMC Romania S.r.l.
Str. Frunzei, Nr. 29, Sector 2, Bucharest, Romania
TEL: 01-3205111 FAX: 01-3261489
SLOVAKIA SMC Priemyselná automatizáciá, s.r.o
Nova 3, SK-83103 Bratislava
TEL: 02-4445-6725 FAX: 02-4445-6028
SLOVENIA SMC Industrijska Avtomatilca d.o.o.
Grajski trg 15, SLO- 8360 Zuzemberk, Slovenia
TEL: 07388-5240 FAX: 07388-5249
SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd.
P.O.Box 240 Paardeneiland 7420 South Africa
TEL: 021-511-7021 FAX: 021-511-4456
EGYPT (Distributor) Saadani Trading & Ind. Services
15 Sebaai Street, Miami 21411 Alexandria, Egypt
TEL: 3-548-50-34 FAX: 3-548-50-34
Oceania/Asia
AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd.
14-18 Hudson Avenue Castle Hill NSW 2154, Australia
TEL: 02-9354-8222 FAX: 02-9894-5719
NEW ZEALAND SMC Pneumatics (New Zealand) Ltd.
8C Sylvia Park Road Mt.Wellington Auckland, New Zealand
TEL: 09-573-7007 FAX: 09-573-7002
TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd.
17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN
TEL: 03-322-3443 FAX: 03-322-3387
HONG KONG SMC Pneumatics (Hong Kong) Ltd.
29/F, Clifford Centre, 778-784 Cheung, Sha Wan Road, Lai Chi Kok, Kowloon,
Hong Kong
TEL: 2744-0121 FAX: 2785-1314
SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd.
89 Tuas Avenue 1, Jurong Singapore 639520
TEL: 6861-0888 FAX: 6861-1889
PHILIPPINES SHOKETSU SMC Corporation
Unit 201 Common Goal Tower, Madrigal Business Park,
Ayala Alabang Muntinlupa, Philippines
TEL: 02-8090565 FAX: 02-8090586
MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd.
Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, Batu 3 40000 Shah Alam
Selangor, Malaysia
TEL: 03-56350590 FAX: 03-56350602
SOUTH KOREA SMC Pneumatics Korea Co., Ltd.
Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu,
Seoul, 152-050, South Korea
TEL: 02-3219-0700 FAX: 02-3219-0702
CHINA SMC (China) Co., Ltd.
7 Wan Yuan St. Beijing Economic & Technological Development Zone 100176, China
TEL: 010-67882111 FAX: 010-67881837
THAILAND SMC Thailand Ltd.
134/6 Moo 5, Tiwanon Road, Bangkadi, Amphur Muang, Patumthani 12000, Thailand
TEL: 02-963-7099 FAX: 02-501-2937
INDIA SMC Pneumatics (India) Pvt. Ltd.
D-107 to 112, Phase-2, Extension, Noida, Dist. Gautaim Budh Nagar,
U.P. 201 305, India
TEL: (0120)-4568730 FAX: 0120-4568933
INDONESIA (Distributor) P.T. Riyadi Putera Makmur
Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia
TEL: 021-625 5548 FAX: 021-625 5888
PAKISTAN (Distributor) Jubilee Corporation
First Floor Mercantile Centre, Newton Road Near Boulton Market P.O. Box 6165
Karachi 74000 Pakistan
TEL: 021-243-9070/8449 FAX: 021-241-4589
ISRAEL (Distributor) Baccara Automation Control
Kvutzat Geva 18915 Israel
TEL: 04-653-5960 FAX: 04-653-1445
SAUDI ARABIA (Distributor) Assaggaff Trading Est.
P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia
TEL: 02-6761574 FAX: 02-6708173
16-14-21
SMC’s Global Service Network