Digital Delay Units series DDU-11 = 5 Taps ECL interfaced Features: @ Input & Output Buffered @ 5 Equally Spaced Taps @ Fits in Standard 16 Pins DIP Specifications: @ Total Delay Tolerance: +5% or better, or 2 NS whichever is greater. m@ No. Taps: 5 equally spaced @ Rise-time: 2 ns typical @ Logic 1 voltage: .96V @ Logic 1 current: .26 MA @ Logic 0 current: 5A m@ Logic 0 voltage: 1.65V m@ Supply voltage: 5.2V @ Operating Temperature: 30C to 85C m@ Power Dissipation: 200 MW typ. (no load) = Temperature Coefficient: 100 PPM/C Part No. *DDU-11-5 *DDU-11-10 *DDU-11-20 *DDU-11-25 DDU-11-50 DDU-11-75 DDU-11-100 DDU-11-150 DDU-11-200 DDU-11-250 DDU-11-300 DDU-11-400 DDU-11-500 time delay measurements referenced to 1st tap. Test Conditions: @ Input pulse-width: 150% of total delay. @ Input pulse rise-time: <6 ns @ Input pulse voltage: .7V m Rise-time measured from 20% to 80% of leading edge w Delay time measured at 50% of leading edge. @ All measurements taken @ Vee = 5.2V and Ta = 25C m@ Unless otherwise specified, ail time-delays are referenced to the input pin. DATA DELAY DEVICES Inc. @ 385 Lakeview Avenue, Clifton, New Jersey 07011 (201) 772-1106 = TWX 710-989-7008 14