196 DLC www.vishay.com Vishay BCcomponents Energy Storage Double Layer Capacitors FEATURES * Polarized capacitor with high charge density, alternative product to rechargeable backup batteries * Dielectric: electric double layer * Radial leads, cylindrical case, insulated with a blue sleeve * Available in both vertical and low-profile versions * Unlimited charge and discharge cycle numbers * No charge-discharge control circuitry and no series resistor necessary * Maintenance-free, no periodic replacement or service necessary * Ecologically beneficial (no Cd, no Li) * Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 APPLICATIONS * Energy storage, for backup of semiconductor memories (CMOS) in all fields of electronics * Telecommunication, audio-video, EDP * General industrial, clock and timer systems MARKING The capacitors are marked with the following information: * Rated capacitance (in F) * Rated voltage (in V) * Date code, in accordance with IEC 60062 * Name of manufacturer * Negative terminal identification * Upper category temperature (at 85 C types only) QUICK REFERENCE DATA VALUE DESCRIPTION Nominal case sizes (O D x L in mm) Rated capacitance range, CR STANDARD FORM A HIGH VOLTAGE FORM A HIGH TEMPERATURE FORM A VERTICAL, MINIATURIZED FORM B 13 x 7 and 21 x 7.5 13 x 9 and 21 x 9 13 x 9 and 21 x 9 11.5 x 13 (vertical) 0.047 F to 1.0 F 0.047 F to 0.68 F 0.047 F to 0.68 F 0.047 F to 0.33 F Tolerance on CR at 20 C -20 % to +80 % Rated voltage, UR 5.5 V 6.3 V 5.5 V 5.5 V Maximum surge voltage, US 6.3 V 7.0 V 6.3 V 6.3 V Category temperature range -25 C to +70 C -25 C to +70 C -25 C to +85 C -25 C to +70 C at 85 C - - 1000 h - at 70 C 1000 h 1000 h 2800 h 1000 h at 40 C 8000 h 8000 h 23 000 h 8000 h at 25 C 23 000 h 23 000 h 64 000 h 23 000 h Useful life at UR: Shelf life at 0 V Climatic category IEC 60068 Revision: 13-Mar-18 1000 h at upper category temperature 25 / 070 / 21 25 / 070 / 21 25 / 085 / 21 25 / 070 / 21 Document Number: 28362 1 For technical questions, contact: energystorage@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 196 DLC www.vishay.com Vishay BCcomponents SELECTION CHART FOR CR, UR, AND FORM AT UPPER CATEGORY TEMPERATURE (UCT) CR (F) UR = 5.5 V FORM 0.047 0.1 0.22 0.33 0.47 0.68 1.0 UCT = 85 C 13 x 9 13 x 9 x 9 21 x 9 21 x 9 - A B A B A B A B A B A B A UR = 6.3 V UCT = 70 C 13 x 9 13 x 9 21 x 9 21 x 9 - UCT = 70 C 13 x 7 11.5 x 13 13 x 7 11.5 x 13 13 x 7 11.5 x 13 13 x 7 11.5 x 13 21 x 7.5 21 x 7.5 DIMENSIONS in millimeters AND AVAILABLE FORMS Sleeve 0.8 0.1 1.2 0.1 0.5 0.1 5 0.3 61 L OD 61 Fig. 1 - Form A: Low profile (4.5) OD L Laser weld + Sleeve 4.0 0.3 5.0 0.3 Solder plating (0.8) 5.0 0.5 Fig. 2 - Form B: Vertical DIMENSIONS in millimeters, MASS AND PACKAGING QUANTITIES NOMINAL CASE SIZE O D x L (mm) 11.5 x 13 13 x 7 13 x 9 21 x 7.5 21 x 9 CASE CODE 1 2 3 4 5 FORM O Dmax. Lmax. B A A A A 11.8 13.5 13.5 21.5 21.5 13.5 7.5 9.5 8.0 9.5 MASS (g) 1.5 2.8 3.4 7.1 8.8 PACKAGING QUANTITIES 2000 1000 1000 500 500 Note * Packaging: bulk in box Revision: 13-Mar-18 Document Number: 28362 2 For technical questions, contact: energystorage@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 196 DLC www.vishay.com Vishay BCcomponents ORDERING EXAMPLE ELECTRICAL DATA Double layer capacitor 196 series SYMBOL DESCRIPTION CR Rated capacitance, tolerance -20 % / +80 %, measured by constant current discharge method UCT Max. leakage current after 30 min at UR RI Max. internal resistance at 1 kHz Nominal case size: O 21 mm x 7.5 mm; Form A Ordering code: MAL2 19612105E3 Former 12 NC: 2222 19612105 Upper category temperature IL 1.0 F / 5.5 V Note * Unless otherwise specified, all electrical values in Table 1 apply at Tamb = 20 C, P = 86 kPa to 106 kPa and RH = 45 % to 75 % Table 1 ELECTRICAL DATA AND ORDERING INFORMATION UR (V) NOMINAL CASE SIZE ODxL (mm) CASE CODE FORM UCT (C) 0.047 13 x 7 2 A 0.10 13 x 7 2 A 0.22 13 x 7 2 0.33 13 x 7 0.47 21 x 7.5 1.0 21 x 7.5 CR (F) IL 30 min (A) RI 1 kHz () ORDERING CODE 70 69 120 MAL219612473E3 70 100 75 MAL219612104E3 A 70 135 75 MAL219612224E3 2 A 70 182 75 MAL219612334E3 4 A 70 216 30 MAL219612474E3 4 A 70 315 30 MAL219612105E3 3 A 85 69 300 MAL219622473E3 STANDARD SERIES 5.5 HIGH TEMPERATURE SERIES 0.047 5.5 13 x 9 0.10 13 x 9 3 A 85 100 200 MAL219622104E3 0.47 21 x 9 5 A 85 216 50 MAL219622474E3 0.68 21 x 9 5 A 85 260 50 MAL219622684E3 VERTICAL, MINIATURIZED SERIES 5.5 0.047 11.5 x 13 1 B 70 69 120 MAL219632473E3 0.10 11.5 x 13 1 B 70 100 75 MAL219632104E3 0.22 11.5 x 13 1 B 70 135 75 MAL219632224E3 0.33 11.5 x 13 1 B 70 182 75 MAL219632334E3 0.047 13 x 9 3 A 70 69 300 MAL219613473E3 0.10 13 x 9 3 A 70 100 200 MAL219613104E3 0.47 21 x 9 5 A 70 216 50 MAL219613474E3 0.68 21 x 9 5 A 70 260 50 MAL219613684E3 HIGH VOLTAGE SERIES 6.3 Revision: 13-Mar-18 Document Number: 28362 3 For technical questions, contact: energystorage@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 196 DLC www.vishay.com Vishay BCcomponents MEASURING OF CHARACTERISTICS CAPACITANCE (C) INTERNAL RESISTANCE (RI) AT 1 kHz Capacitance shall be measured by constant current discharge method. VC V R I = ---------------3 10 DISCHARGE CURRENT AS A FUNCTION OF RATED CAPACITANCE PARAMETER Rated capacitance, CR VALUE UNIT 0.047 0.1 0.22 0.33 0.47 0.68 1.0 F 1 mA A + C Discharge current, ID 0.1 1.0 V 1 kHz mA Fig. 5 - Test circuit for RI measurement LEAKAGE CURRENT (IL) Leakage current shall be measured after 30 min application of rated voltage UR: U (V) UR V V I L A = -----------4 10 2.0 V 0 Time 30 min T (s) RS 100 + Fig. 3 - Voltage diagram for capacitance measurement + C Capacitance value CR is given by discharge current ID, time T and rated voltage UR, according to the following equation: Fig. 6 - Test circuit for leakage current I D mA x 10 -3 x T s C F = --------------------------------------------------------UR V - 2 Curve 1: 1.0 F, 5.5 V Curve 2: 0.47 F, 5.5 V Curve 3: 0.22 F, 5.5 V Curve 4: 0.1 F, 5.5 V Curve 5: 0.047 F, 5.5 V RS = 100 102 A + V C IL (A) Constant current discharger 10 1 2 3 Fig. 4 - Test circuit for capacitance measurement 4 5 1 1 10 20 30 40 50 Time (h) Fig. 7 - Typical leakage current as a function of time Revision: 13-Mar-18 Document Number: 28362 4 For technical questions, contact: energystorage@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 196 DLC www.vishay.com Vishay BCcomponents DISCHARGE CHARACTERISTICS Backup time of 196 DLC series capacitors depends on minimum memory holding voltage and discharge current (corresponding with the current consumption of the load). For minimum backup times of standard and vertical miniaturized series see Figures 8 and 9 (charging time 24 h). MGA695 10 5 Backup time (s) Figure 10 shows the backup time when a 196 DLC capacitor is discharged by a constant resistance (charging time 24 h). The horizontal axis shows the initial value of discharge current if 5 V is connected to the capacitor via a fixed series resistor. Example: 1 A corresponds to 5 M and 0.1 A corresponds to 50 M The vertical axis shows that period of time during which the voltage drops from 5 V to 2 V. 10 4 MLB203 10 3 10 3 10 2 1 2 Curve 1: 1.0 F, 5.5 V Curve 2: 0.47 F, 5.5 V Curve 3: 0.22 F, 5.5 V Curve 4: 0.1 F, 5.5 V Curve 5: 0.047 F, 5.5 V Voltage drop from 5.0 V to 3.5 V Backup time (s) 3 4 5 2 10 10-3 10-2 10-1 1 Discharge current (mA) 10 10 Fig. 8 - Typical backup time as a function of discharge current MGA696 10 6 1 102 Curve 1: 1.0 F, 5.5 V Curve 2: 0.47 F, 5.5 V Curve 3: 0.22 F, 5.5 V Curve 4: 0.1 F, 5.5 V Curve 5: 0.047 F, 5.5 V Voltage drop from 5.0 V to 2.0 V by means of a fixed resistor 10 5 4 5 1 10-2 Backup time (s) 3 10-1 1 10 102 103 Initial value discharge current (A) Fig. 10 - Typical backup time as a function of initial discharge current 10 4 10 3 104 Curve 1: 1.0 F, 5.5 V Curve 2: 0.47 F, 5.5 V Curve 3: 0.22 F, 5.5 V Curve 4: 0.1 F, 5.5 V Curve 5: 0.047 F, 5.5 V Voltage drop: from 5.0 V to 2.0 V 10-3 10-2 1 2 3 4 5 10-1 1 10 Discharge current (mA) Fig. 9 - Typical backup time as a function of discharge current Revision: 13-Mar-18 Document Number: 28362 5 For technical questions, contact: energystorage@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 196 DLC www.vishay.com Vishay BCcomponents Table 2 TEST PROCEDURES AND REQUIREMENTS for standard and vertical miniaturized series (5.5 V; 70 C) NAME OF TEST IEC 60384-4 / EN130300 SUBCLAUSE PROCEDURE (quick reference) REQUIREMENTS Tensile strength; application of loading force for 10 s: Robustness of terminations 4.4 20 N (standard series) No breaks 5 N (vertical miniaturized series) C/C: 10 % Resistance to soldering heat 4.5 Solder bath; 260 C; 5 s Solderability 4.6 Solder bath; 235 C; 2 s 75 % tinning Vibration 4.8 10 Hz to 55 Hz; 1.5 mm; 3 directions; 2 h per direction C/C: 10 % Damp heat, steady state 4.12 500 h at 55 C; RH 90 % to 95 %; no voltage applied Endurance 4.13 RI and IL spec. limit RI and IL spec. limit C/C: 30 % RI 4 x spec. limit IL 2 x spec. limit C/C: 30 % Tamb = 70 C; 5.5 V applied; 1000 h RI 4 x spec. limit IL 2 x spec. limit C/C: 30 % Useful life Storage at upper category temperature Self discharge Characteristics at high and low temperature - 4.17 - 4.19 Tamb = 70 C; 5.5 V applied; 1000 h Tamb = 70 C; no voltage applied; 1000 h 24 h storage at room temperature after application of 5 V for 1 h Step 1: reference measurement at +20 C of C, RI and IL Step 2: measurement at -25 C Step 3: measurement at +20 C Step 4: measurement at +70 C Step 5: measurement at +20 C RI 4 x spec. limit IL 2 x spec. limit C/C: 30 % RI 4 x spec. limit IL 2 x spec. limit Remaining voltage: 4 V C/C: 30 % of +20 C value RI 5 x the +20 C value IL 4 x the +20 C value Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability. Revision: 13-Mar-18 Document Number: 28362 6 For technical questions, contact: energystorage@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. (c) 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 08-Feb-17 1 Document Number: 91000 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Vishay: MAL219612224E3 MAL219612105E3 MAL219612104E3 MAL219612473E3 MAL219622104E3 MAL219613474E3 MAL219632104E3 MAL219622474E3 MAL219632224E3 MAL219622473E3 MAL219632473E3 MAL219613473E3 MAL219613684E3 MAL219622684E3 MAL219612474E3 MAL219632334E3 MAL219613104E3 MAL219612334E3