Input Specifications
Parameters Conditions Min Typ Max Units
Operating Range 47-63Hz 90 264 VAC
Input Current Nominal line, full load 12 A
Inrush Current 120VAC, 250C, cold star t 80 Apk
240VAC, 250C, cold start 16 0 Apk
Efficiency Nominal line, full load 70 75 80 %
Holdup Full load 20 msec
Power Factor (1) Full load 0.99
Notes: (1) Harmonic currents meet EN61000-3-2
Output Voltages and Maximum Rated Loads
Model Output Voltage Output Current
TX10005AASLPLNH 5. 0 200A
TX10005BASLPLNH(1) 12.0 84A
TX10005CASLPLNH(1) 15.0 67A
TX10005DASLPLNH(1) 18.0 56A
TX10005EASLPLNH(1) 24.0 42A
TX10005FASLPLNH(1) 28.0 36A
TX10005GASLPLNH(1) 36.0 28A
TX10005HASLPLNH(1) 48.0 21A
TX10005JASLPLNH(1) 20.0 50A
TXD10005KASLPLNH(1) 3.3 182A
TXD10005LASLPLNH(1) 2.5 200A
Notes: (1) Model specified without optional ORing diode; to specify the diode option, replace the letter “N” with the letter “D”, no O-Ring diode on 5V models.
Output Specifications
Parameter Conditions Min Typ Max Units
Output Power All environmental and line conditions 1000 Watts
Voltage Adjustment Range Relative to nominal output voltage +5 %
Output Regulation Line and load (each) +0.2 %
Minimum Load 0 Amps
PARD Measured at output ter minals, 20MHz 1 % pk-pk
Temperature Coefficient 00 to 500C+0.2 %/0C
Environmental Specifications
Parameter Conditions Min Typ Max Units
Ambient Temperature Output de-rated linearly to 50% of
(Operating) rated capacity between 500C and 700C 0 +70 0C
Ambient Temperature Non-operating -50 +85 0C
Altitude (Operating) -200 +10,000 Feet
Altitude (Non-operating) -200 +50,000 Feet
Shock Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test
Vibration Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test
Cooling The TX1000 is provided with an internal cooling fan.