Q1F-1150V48
Q1F-2150V123
Q1F-2150V125
Q1H-5060V
Q1I-1060V12
Q1I-2050V53
Q1I-2060V123
Q1I-2060V125
Q1J-1050V-5
Q1J-1060V-12
Q1J-1060V24
Q1J-1060V48
Q1K-5150V
Q1K-5200V
Q1L-5060V
RH1E-1067V
* TEMPERATURE: OPERATING 0 TO 70 DEGREES CENTIGRADE(90~264
VAC);NON-OPERATING TEMPERATURE: -20 TO 80 DEGREES CENTIGRADE
* EFFICIENCY: 85%(+/-2%) AT 230V; LOAD CONDITION: 12V/11.18A; 5V/6.47A;
3.3V/5.53A; -12V/0.36A; 5VSB/2.17A
* HOLD UP TIME: WHEN AC SOURCE SHUTDOWN DC OUTPUT MUST BE
MAINTAIN 100MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
(AC115V@80% OF FULL LOAD).
* OVER POWER PROTECTION: 110~160%
* OVER VOLTAGE PROTECTION: +3.3V→3.6V~4.3V, +5V→5.6V~6.5V,
+12V→13.2~15V
* SHORT CIRCUIT: +5V, +3.3V, +12V, -12V, +5VSB
* SAFETY: TO MEET UL, CUL, TUV, CCC
* LEAKAGE CURRENT: 3.5 mA MAX. AT NOMINAL VOLTAGE 264VAC
* REMOTE ON/OFF CONTROL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT
LLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL
SSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-
REGULATIONS.
Pa
e 2 of 2ZIPPY -
12/5/2012http://www.zipp
.com/P
PRODUCT
DETAIL.asp?pcpw
rfnbr=1&pcp
name=Open...