Volts Output Current
Model Number
5Vsb
12V
12V Fan
5
5Vsb
18V
12V Fan
5
5Vsb
24V
12V Fan
5
5Vsb
48V
12V Fan
5
5Vsb
56V3
12V Fan
5
FEATURES AND BENEFITS
3.3” x 6.2” x 1.62” Package
Up to 425W of Air-cooled Power, 300W Convection
Isolated 12V Fan Output
Universal Input 90-264VAC Input Range
5V at 2A Isolated Standby Output
Inhibit, Power Fail, DC OK Signals, Remote Sense
MODEL SELECTION
Audio Visual
Automation
Broadcast
Industrial
Display
& Signage
ITE & Comms
Lighting
Military COTS
Renewable
Test &
Measurement
Efficiency 90% Typical
3 Years Warranty
Approved to CSA/EN/IEC/UL60950-1, 2nd Edition
Compliant to High Levels of EMC Per EN61000-4
Meets Class B Conducted EMI with 6db Margin
Class A Radiated EMI with 3db Margin
MTBF7
3,89,750
356,330
355,520
354,722
354,560
TU425S12E
TU425S18E
TU425S24E
TU425S24E
TU425S56E
88%
88%
90%
90%
90%
Efficiency³
(Main Output)
5.5V – 8.0V
N/A
14.0 ± 1.1V
5.5V – 8.0V
N/A
21.0 ± 2.0V
5.5V – 8.0V
N/A
28.0 ± 2.5V
5.5V – 8.0V
N/A
55.0 ± 4.0V
5.5V – 8.0V
N/A
63.0 ± 4.0V
OVP
Threshold
±5%
±10%
±3%
±5%
±10%
±3%
±5%
±10%
±3%
±5%
±10%
±3%
±5%
±10%
±3%
Total
Regulation
100mV
360mV
240mV
100mV
360mV
480mV
100mV
360mV
560mV
100mV
360mV
120mV
100mV
360mV
180mV
Ripple & Noise
(mV pk-pk)w/200LFM air¹ Convection²
2.0A
0.5A
22.0A
2.0A
0.5A
14.6A
2.0A
0.5A
11.9A
2.0A
0.5A
5.9A
2.0A
0.5A
5.1A
2.0A
1.0A
32.2A
2.0A
1.0A
21.4A
2.0A
1.0A
16.8A
2.0A
1.0A
8.4A
2.0A
1.0A
7.2A
Notes : 1. Total power with 200lfm of forced air cooling is 425W (385W for 12V model) including 12V/1A for Fan output and 5V/2A standby.
2. Maximum convection cooled power is limited to 280W for 12V model and 300W for other models. This includes 12V/0.5A fan output and 5V/2A standby output.
3. Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25°C.
4. Measured at 25°C ambient with noise probe directly at end of 6” twisted pair terminated with 0.1μF ceramic and 10μF low ESR capacitors. Values will be higher at ambient
temperatures below 0°C.
5. Fan Output: If the load on this output is other than a fan, a short circuit condition on this output can only be remedied by removing both the cause of the short circuit and the load.
This will allow the output to resume normal operation.
6. No output adjustment for 56V model.
7. MTBF values are in hours, per Telcordia 332, Issue 6, 25°C, full rated load (w/airflow) at 110VAC input.
425W Single Output
Test and Measurement/Industrial Grade
TU425 Family
TU425 Datasheet v0418 Page 1Copyright © 2018 SL Power Electronics Corp. - All rights reserved.
INPUT
AC Input
Input Current
Inrush Current
Input Fuses
Efficiency
Leakage Current
Common Mode Noise
Sensing transformer temperature, 135°C (55°C ambient temperature at full load), Auto recovery
Overvoltage Protection
100-240VAC, ±10%, 47-63Hz, 1Ø
120–300 VDC (
external fuse required for DC input
)
115VAC: 5.2A, 230VAC: 2.5A
264VAC, Cold start: will not exceed 40Arms within ½ cycle. I²T = 25A²/sec maximum
F1, F2: 6.3A, 250VAC
See Model selection chart on page 1
<750μA @ 264VAC, 60Hz, NC
<1.5mA @ 264VAC, 60Hz, SFC
Line Frequency: <2.5Vrms @ 115VAC, <5Vrms @ 230VAC, 50/60Hz. See App note for test set-up and
typical graphs. For high frequency noise, consult the factory
OUTPUT
Output Voltage
Output Power 425W continuous, with 200 lfm airflow
300W convection cooled – See chart for specific voltage model ratings
See chart on page 1. Initial setpoint within 0.5% of nominal. Adjustable +/-5% from nominal (except 56V)
Ripple and Noise 0.5%rms, 1% pk-pk, see Model selection chart on page 1
Hold-Up Time Main output: >20ms for 300W @ 120VAC/60 Hz, >16ms for 383W (90% of 425W) @ 120VAC/60Hz
5Vsb output: >500ms
Turn On Time (Main Output) Main output: <1 sec max @115VAC, Rise time 30ms max
5Vsb turn-on time is 500ms max, Rise time 50ms max. Output voltage rise is monotonic
Transient Response 50% load step, ∆i/∆t: <0.2A/μS. Max voltage deviation = 5%. Recover to within 1% of nominal within 500μS
Minimum Load Not required for main output or 5Vsb
Fan output: 0.5A min required on the main output in order for the 12V fan output to be within regulation
Total Regulation See Model selection chart on page 1
Switching Frequency 75kHz, Typical
Power Factor >0.99 @ 115VAC, Full Load
>0.95 @ 230VAC, Full Load
Overtemperature Protection
130 to 170% of rating, Hiccup mode, Auto recovery
Overload Protection
Short Circuit Protection
OVP latch. See chart for trip ranges. 5V standby output (latch). See chart for trip range
Main output & 5Vsb: Cycling type, Auto recovery. Fan output: Recovery only after removal of short and load.
See note 5 on page 1
PROTECTION
TU425 Datasheet v0418 Page 2Copyright © 2018 SL Power Electronics Corp. - All rights reserved.
425W Single Output
Test and Measurement/Industrial Grade
TU425 Family
AUXILIARY SIGNALS
Notes :
1. Consult Factory for proper set-up for current sharing operation.
ISOLATION SPECIFICATIONS
Isolation
Input-Output: 3,000VAC
Input-Ground: 1,500VAC
Output-Ground: 500VAC
ENVIRONMENT
SAFETY
RELIABILITY
EN/CSA/UL/IEC 60950-1, 2nd edition
Safety Standards
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6
shocks total
Shock
MTBF
E-Cap Life
See model selection chart on page 1
7 years, based on typical operation of 12 hours/day,
261 days/year at 40°C ambient temp
Operating
Temperature
Temperature
Derating
Storage
Temperature
Altitude
Relative Humidity
Derate output power linearly above 50°C to 50% at 70°C
-10 to 70°C. Starts up at -40°C. The unit will meet all
published specifications after a warm-up period
See Application note for operating conditions during
start-up
-40°C to +85°C
Operating: Up to 5,000m (derating may be required
above 3,000m, consult factory)
Non-operating: -500 to 40,000 ft
5% to 95%, Non-condensing
Operating: 0.003g/Hz, 1.5grms overall, 3 axes,
10 min/axis
Non-operating: 0.026g2/Hz, 5.0grms overall, 3 axes,
1 hr/axis
670g
W: 3.3” x L: 6.2” x H: 1.62”
W: 84mm x L: 157.5mm x H: 41mm
Weight
Dimensions
Vibration
Goes HIGH when main DC output is above 90% of nominal voltage and goes LOW when the output is below 90% of rated main
output DC voltage
Logic HIGH or open = ON
Logic LOW or short to ground = OFF
Compensates for up to 0.5V voltage drop for 48V & 56V models, and 0.16V voltage drop for 12V & 24V models
Maximum deviation of 5% (main output) any 50% step above 5% load
Signal is high within 500ms after the main output is within regulation band upon AC turn on. Goes low with 4ms min before
the main. DC output drops below 90% of nominal value when AC turns off
12V @ 1A (air cooled ) or 0.5A (convection), +/-10% regulation for load change of 0.5A to FL on the main output
Active single wire, up to 4 supplies in parallel. Paralleled output voltages must be set to within 0.5% of each other
Contact Factory for details on the required set-up for proper operation
5V @ 2A, +/-5% regulation over all changes in main output load current
5% when the load current is ≥50% of the total available load current, 10% when the load current is between 25% - 49% of
the total available load current. Remote sense lines must be connected to ensure accuracy
DC OK
Inhibit
Remote Sense
Power Good/ Power Fail
Fan Output
5V Standby Output
Current Share Accuracy¹
Current Share¹
TU425 Datasheet v0418 Page 3Copyright © 2018 SL Power Electronics Corp. - All rights reserved.
425W Single Output
Test and Measurement/Industrial Grade
TU425 Family
Line Surge Immunity
Static Discharge
Immunity
Radiated RF Immunity
EFT/Burst Immunity
Voltage Dip Immunity EN55024/IEC61000-4-11, Dips: 100%, 10ms; 30%, 500ms; 60%, 100ms
Interruptions: 100%, 5,000ms; Performance Criteria A, A, B & B
EMI/EMC COMPLIANCE
Input Connector
J101
Main DC Output
J302, J303
Fan Output
J301
Signal Connector
J401
CONNECTOR INFORMATION
Conducted Emissions
Radiated Emissions
Power Frequency Magnetic
Field Immunity EN55024/IEC61000-4-8, Level 3, 10A/m, Criteria A
Conducted RF Immunity EN55022/IEC61000-4-6, Level 3, 10V/m, Criteria A
EN55024/IEC61000-4-5, Level 3, 1kV diff, 2kV common-mode, Criteria A Level 4, 2kV diff, 4kV common-mode, Criteria C
EN55024/IEC61000-4-2, Level 4, 8kV contact discharge, 15kV air discharge, Criteria A
EN55022/IEC61000-4-3, Level 2, 3V/m, Criteria A
EN55024/IEC61000-4-4, Level 3, 2kV (PS output), 1kV (signal outputs), Criteria A
EN55011/CISPR22 Class B, FCC Part 15.107, Class B, 6db margin, Typical
EN55011/CISPR22 Class A, FCC Part 15.109, Class A, 3db margin, Typical
Flicker Test
Line Harmonic Emissions
EN55024/IEC61000-3-3, Section 5
EN55024/IEC61000-3-2, Class A, C & D at full load (425W output)
Mating Connector:
Molex 19141-0058
19141-0063
19141-0083
Mating Connector:
Molex 90142-0010
Pins: 90119-2110
Mating Connector:
Tyco AMP 1375820-2
Pins: 1375819-1
Mating Connector:
Tyco/AMP 640250-5
Pins: 3-770476-1
Term 1 – J302: (+V)
Term 2 – J303: (-V)
PIN 1) 12V Fan (+)
PIN 2) 12V Fan (-)
PIN 1) FG
PIN 2) NC
PIN 3) AC Neutral
PIN 4) NC
PIN 5) AC Line
6) Power Good
7) +5Vsb Output
8) +5Vsb Output
9) DC OK
10) Common
PIN 1) Remote Sense (+) Pin
PIN 2) Common Pin
PIN 3) Remote Sense (-) Pin
PIN 4) Current Sharing Pin
PIN 5) Remote Inhibit Pin
TU425 Datasheet v0418 Page 4Copyright © 2018 SL Power Electronics Corp. - All rights reserved.
425W Single Output
Test and Measurement/Industrial Grade
TU425 Family
MECHANICAL DRAWING
Notes :
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), Tolerance is ±0.02” (±0.5).
3. FG is safety ground connection.
4. Specifications are for convection rating at factory settings at 115VAC input 25 °C unless otherwise stated.
5. Warranty: 3 years.
TU425 Datasheet v0418 Page 5Copyright © 2018 SL Power Electronics Corp. - All rights reserved.
425W Single Output
Test and Measurement/Industrial Grade
TU425 Family