AUXILIARY SIGNALS
Notes :
1. Consult Factory for proper set-up for current sharing operation.
ISOLATION SPECIFICATIONS
Isolation
Input-Output: 3,000VAC
Input-Ground: 1,500VAC
Output-Ground: 500VAC
ENVIRONMENT
SAFETY
RELIABILITY
EN/CSA/UL/IEC 60950-1, 2nd edition
Safety Standards
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6
shocks total
Shock
MTBF
E-Cap Life
See model selection chart on page 1
7 years, based on typical operation of 12 hours/day,
261 days/year at 40°C ambient temp
Operating
Temperature
Temperature
Derating
Storage
Temperature
Altitude
Relative Humidity
Derate output power linearly above 50°C to 50% at 70°C
-10 to 70°C. Starts up at -40°C. The unit will meet all
published specifications after a warm-up period
See Application note for operating conditions during
start-up
-40°C to +85°C
Operating: Up to 5,000m (derating may be required
above 3,000m, consult factory)
Non-operating: -500 to 40,000 ft
5% to 95%, Non-condensing
Operating: 0.003g/Hz, 1.5grms overall, 3 axes,
10 min/axis
Non-operating: 0.026g2/Hz, 5.0grms overall, 3 axes,
1 hr/axis
670g
W: 3.3” x L: 6.2” x H: 1.62”
W: 84mm x L: 157.5mm x H: 41mm
Weight
Dimensions
Vibration
Goes HIGH when main DC output is above 90% of nominal voltage and goes LOW when the output is below 90% of rated main
output DC voltage
Logic HIGH or open = ON
Logic LOW or short to ground = OFF
Compensates for up to 0.5V voltage drop for 48V & 56V models, and 0.16V voltage drop for 12V & 24V models
Maximum deviation of 5% (main output) any 50% step above 5% load
Signal is high within 500ms after the main output is within regulation band upon AC turn on. Goes low with 4ms min before
the main. DC output drops below 90% of nominal value when AC turns off
12V @ 1A (air cooled ) or 0.5A (convection), +/-10% regulation for load change of 0.5A to FL on the main output
Active single wire, up to 4 supplies in parallel. Paralleled output voltages must be set to within 0.5% of each other
Contact Factory for details on the required set-up for proper operation
5V @ 2A, +/-5% regulation over all changes in main output load current
5% when the load current is ≥50% of the total available load current, 10% when the load current is between 25% - 49% of
the total available load current. Remote sense lines must be connected to ensure accuracy
DC OK
Inhibit
Remote Sense
Power Good/ Power Fail
Fan Output
5V Standby Output
Current Share Accuracy¹
Current Share¹
TU425 Datasheet v0418 Page 3Copyright © 2018 SL Power Electronics Corp. - All rights reserved.
425W Single Output
Test and Measurement/Industrial Grade
TU425 Family