Input Specifications
Input current no load 5 Vin models: 40 mA typ.
12 Vin models: 27 mA typ.
24 Vin models: 15 mA typ.
48 Vin models: 8 mA typ.
Surge voltage (1 sec. max.) 5 Vin models: 12 V max.
12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Input filter internal capacitor
Conducted noise EN 55022 class A, B (with external components)
ESD (electrostatic discharge) EN 61000-4-2, ±8 kV / ±6 kV, perf. criteria A
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / surge (with external input capacitor) EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV perf. criteria A
–external input capacitor all models: 220 F/100V
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Magnetic field immunity EN 61000-4-8, 3 A/m, perf. criteria A
Output Specifications
Voltage set accuracy ±1.5 % max.
Regulation – Input variation 0.2 % max.
– Load variation 0 – 100 % 1 % max.
dual output: 2 % max. (balanced load)
cross regulation - dual output: 5 % max. (asymmetrical load 25 % / 100 %)
Minimum load no minimum load required
Ripple and noise (20 MHz Bandwidth) 70 mVp-p typ.
Transient response – Recovery time ( 25% load step change) 500 µs typ.
– Response deviation ( 25% load step change) 5 % max.
Current limitation at 180% of nominal lout typ., foldback
Short circuit protection continuous, automatic recovery
Capacitive load – Single output all models: 100 F max.
– Dual output all models: 100 F max. (each output)
General Specifications
Temperature ranges – Operating (convection cooling 20LFM, 0,1m/s) –40°C to +70°C (without derating)
– Case temperature +90°C max.
– Storage temperature –50°C to +125°C
Derating 4.0%/K above 70°C
Humidity (non condensing) 95 % rel H max.
Isolation voltage – I/O isolation voltage (60 sec.) 1’500 VDC
Isolation capacitance (input/output) 100 pF typ.
Isolation resistance (input/output) >1 Gohm
Altitude during operation 5’000 m
Temperature coefficient ±0.02 %/K typ.
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >4‘226‘000 h
Switching frequency 100 kHz min. (PFM)
Safety standards UL 60950-1
IEC/EN 60950-1
– Certification documents www.tracopower.com/overview/tdl2
Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU