Features * * * * * Regulated Converter Universal input 90-264VAC Efficiency up to 86% Short circuit and over voltage/current protected UL/EN60950 certified, CE marked Conformal coated product Description The RAC45-xxG/OF series are low cost, 4"x2" AC/DC power supplies with universal inputs (90-264VAC) and fully protected and isolated DC outputs in the range of 12V up to 48V. The converters are offered in open frame (/OF) version. The outputs are trimmable to compensate for cable losses and are short circuit and overload protected. The converters work over a wide temperature range of -25C to +60C (with derating), are UL60950, EN60950 and CE certified and comply with Class B EMC limits. The RAC45-G series come with a three year warranty. AC/DC Converter RAC RAC45-G/OF 45 Watt 4" x 2" Open Frame Selection Guide Part Number Input Voltage Range [VAC] 90-264 90-264 90-264 RAC45-12SG/OF RAC45-24SG/OF RAC45-48SG/OF Output Voltage [VDC] 12 24 48 max. Output Current [mA] 3700 1900 1000 Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Efficiency typ. (1) [%] 84 85 86 E196683 UL60950 certified CAN/CSA C22.2 N.60950-1-07 certified EN60950-1 certified EN55032 compliant EN55024 compliant Model Numbering RAC45-__ SG/OF nom. Output Voltage Single Case Style Ordering Examples: RAC45-24SG/OF RAC45-12SG/OF www.recom-power.com 24Vout 12Vout Single Single open frame version open frame version REV.: 2/2018 PA-1 RAC45-G/OF AC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin and full load unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. 90VAC 230VAC 264VAC Output Power 48W Input Voltage Range 1A 0.6A 115VAC 230VAC Input Current Inrush Current 115VAC 230VAC cold start at 25C No load Power Consumption 20A 40A 230VAC 0.5W Input Frequency Range 47Hz 11.4VDC 22.8VDC 45.6VDC 0% 12Vout 24Vout 48Vout Output Voltage Trimming 63Hz 13.2VDC 26.4VDC 52.8VDC Minimum Load Power Factor 115VAC 230VAC 0.6 0.5 Start-up Time 115VAC 230VAC Rise Time 115VAC 230VAC 10ms 8ms Hold-up Time 115VAC 230VAC 16ms 80ms 2s 0.8s Internal Operating Frequency Output Ripple and Noise 65kHz 100kHz 20MHz BW (2) Notes: Note2: 50mVp-p 120mVp-p Measurements are made with a 1.0F & 10F parallel capacitor Efficiency vs. Load RAC45-24SG/OF 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RAC45-12SG/OF 60 50 90VAC 115VAC 230VAC 264VAC 40 30 20 50 90VAC 115VAC 230VAC 264VAC 40 30 20 10 0 60 10 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Value Output Accuracy 1.0% typ. / 3.0% max. Line Regulation 0.2% typ. / 1.0% max. Load Regulation www.recom-power.com 10%-100% load REV.: 2/2018 0.5% typ. / 3.0% max. PA-2 RAC45-G/OF AC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin and full load unless otherwise stated) PROTECTIONS Parameter Type Input fuse Value internal T3.15A / 250V slow blow Short Circuit Protection (SCP) Over Voltage Protection (OVP) continuous, auto recovery 115-135% of Vout nominal Latch OFF Over Voltage Category OVCII 3.9 - 6.2A 2.0 - 3.2A 1.1 - 1.56A 12VDC 24VDC 48VDC Over Current Protection (OCP) Hiccup Mode, auto recovery Class of Equipment Isolation Voltage Isolation Resistance Class I 3kVAC 1.5kVAC 0.5kVDC 100M min. I/P to O/P I/P to PE O/P to PE tested for 1 minute I/P to O/P Isolation Capacitance 2200pF max. Insulation Grade Leakage Current reinforced I/P to O/P O/P to FG 0.25mA max. 3.5mA max. Notes: Note3: Refer to local safety regulations if input over-current protection is also required ENVIRONMENTAL Parameter Condition Operating Temperature Range @ natural convection 0.1m/s Value full load -25C to +50C refer to derating graph -25C to +60C Temperature Coefficient 0.05%/K typ. 5000m Operating Altitude (4) Operating Humidity non-condensing 20% - 90% RH max. Pollution Degree PD2 Conformal Coating provided Shock 20G, 11ms, 3 times for X,Y and Z axis MTBF according to MIL-HDBK-217F, G.B. +25C 200 x 103 hours Notes: Note4: Recognized by UL for safe operation up to 5000m. High altitude operation may impact the performance and lifetime Contact RECOM techsupport for advice continued on next page www.recom-power.com REV.: 2/2018 PA-3 RAC45-G/OF AC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin and full load unless otherwise stated) Operating Altitude (@ Chamber and natural convection 0.1m/s) (limitation E-Cap heitsink) 100 100 90 90 80 80 70 70 Output Load [%] Output Load [%] Derating Graph 60 50 40 60 50 40 30 30 20 20 10 10 0 -25 0 10 20 30 40 50 60 70 80 0 +25C Tamb +50C Tamb 0 1000 2000 Ambient Temperature [C] 3000 4000 5000 6000 Operating Altitude [m] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Information Technology Equipment, General Requirements for Safety E196683 Information Technology Equipment, General Requirements for Safety (LVD) SA1406027L01001 EAC Safety of Low Voltage Equipment RU-AT.49.09571 RoHS2+ Standard UL60950-1, 2nd Edition, 2014 CSA C22.2 No. 60950-1-07, 2nd Ed. 2014 EN60950-1, 2nd Edition, 2013 TP TC 004/2011 RoHS 2011/65/EU + AM2015/863 EMC Compliance Electromagnetic compatibility of multimedia equipment - Emission Requirements Conditions Standard / Criterion without external filter EN55032:2015, Class B Information technology equipment - Immunity characteristics - Limits and methods of measurement ESD Electrostatic discharge immunity test Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity Surge Immunity Immunity to conducted disturbances, induced by radio-frequency fields EN55024:2010 + A1:2015 8kV Air; 4kV Contact EN61000-4-2, Criteria A 3V/m EN61000-4-3, Criteria A AC Power Port: 1.0kV L-L 1.0kV AC Power L-PE 2.0kV Port: N-PE 2.0kV EN61000-4-4, Criteria A EN61000-4-5, Criteria B AC Power Port: 3V EN61000-4-6, Criteria A Power Magnetic Field Immunity 50Hz, 1A/m Voltage Dips and Interruptions Dips: >95% reduction Interruption: >95% EN61000-4-8, Criteria A EN61000-4-11, Criteria A EN61000-4-11, Criteria C Limits of Harmonic Current Emissions Limits of Voltage Fluctuations & Flicker www.recom-power.com EN61000-3-2, Criteria A EN61000-3-3 REV.: 2/2018 PA-4 RAC45-G/OF AC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin and full load unless otherwise stated) DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Material PCB Value FR4 (UL94-V0) Dimension (LxWxH) 101.6 x 51.0 x 28.0mm Weight 126g typ. Dimension Drawing Open Frame (mm) 101.6 21.0 M3 T3.15 1 1 CN2 51.0 CN1 3 2 3 4 Trim Connections LED AC Input (CN1) Top View Pin # Terminal 1 AC/L 3 AC/N 3 Pins (Pin2 removed) with 3.96mm pitch 4.0 DC Output (CN2) Side View Pin # Terminal 1,2 V+ 3,4 V- 4 Pins with 3.96mm pitch FC= fixing centers Crimp Terminal AWG Range: 18-22AWG Tolerance: xx.x= 1.0mm xx.xx= 0.5mm 2.5 28.0 Customer Application Compatible Connectors Housing 3.5 4.0 PCB thickness=1.6mm Customer Application Landwin 3960S Series JST VHR Molex 51144 Series FC 44.3 Crimp Terminal Bottom View Landwin 3963T011R JST SVH-21T-P1.1 Molex 50539 3.15 FC 95.3 continued on next page www.recom-power.com REV.: 2/2018 PA-5 RAC45-G/OF vertical DC AC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin and full load unless otherwise stated) APPLICATION and INSTALLATION Mounting horizontal (standard) AC AC horizontal (standard) DC DC AC If module is mounted vertical or upside-down with natural convection cooling, the power must be derated 10%. vertical vertical DC DC upside-down AC DC AC AC Block diagram L N T3.15A Input upside-down Filter PE DC DC OCP Limit +V Output Filter upside-down Power Stage -V AC AC LED Protection OVP ShutDown Outoput Voltage Regulation Vadj. PACKAGING INFORMATION Parameter Packaging Dimension (LxWxH) Type cardboard box Packaging Quantity 174.0 x 125.0 x 266.0mm 10pcs Storage Temperature Range Storage Humidity Value -40C to +85C non-condensing 10% - 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 2/2018 PA-6