101 Innovation Drive
San Jose, CA 95134
www.altera.com
MasterBlaster Serial/USB
Communications Cable User Guide
Software Version: 80
Document Version: 1.1
Document Date: © July 2008
Copyright © 2008 Altera Corporation. All rights reserved. Altera, The Programmable Solutions Company, the stylized Altera logo, specific device designations, and all other
words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other
countries. All other product or service names are the property of their respective holders. Altera products are protected under numerous U.S. and foreign patents and pending ap-
plications, maskwork rights, and copyrights. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty,
but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of
any information, product, or service described herein except as expressly agreed to in writing by Altera Corporation. Altera customers are advised to obtain the latest version of
device specifications before relying on any published information and before placing orders for products or services.
UG-MB81204-1.1
P25-10322-00
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
Contents
Chapter 1. Installing the MasterBlaster Serial/USB Communications Cable
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1
Installation on a Windows PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2
Installation on a Linux or UNIX Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–3
Selecting the MasterBlaster Cable for the SignalTap II Logic Analyzer . . . . . . . . . . . . . . . . . . . . . . . . 1–4
Chapter 2. MasterBlaster Serial/USB Communications Cable Data Sheet
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–1
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–1
Download Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2
SignalTap II Logic Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–2
MasterBlaster Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–3
Header & Plug Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–3
Powering the MasterBlaster Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–4
Circuit Board Header Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–5
LED Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–5
Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–5
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–7
Chapter Info. Additional Information
Referenced Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info–1
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info–1
How to Contact Altera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info–1
Typographic Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info–2
iv
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
List of Figures v
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
List of Figures
Figure 1–1: MasterBlaster Serial/USB Communications Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Figure 1–2: The Hardware Setup Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Figure 2–1: MasterBlaster Serial/USB Communications Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Figure 2–2: MasterBlaster 10-Pin Female Plug Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Figure 2–1: 10-Pin Male Header Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
vi List of Figures
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
List of Tables vii
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
List of Tables
Table 2–1: MasterBlaster 9-Pin Serial D-Type Connector Pin-Outs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Table 2–2: MasterBlaster Female Plug’s Pin Names & Download Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Table 2–1: LED Status Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Table 2–2: MasterBlaster Cable Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Table 2–3: MasterBlaster Cable Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Table 2–4: MasterBlaster Cable DC Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
viii List of Tables
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
1. Installing the MasterBlaster
Serial/USB Communications Cable
Introduction
The MasterBlasterTM serial/USB communications cable is a download cable that
allows PC and workstation users to program and configure devices in-system. The
MasterBlaster cable provides multi-device JTAG chain configuration and
programming support for SRAM-based devices, such as APEXTM 20K and MercuryTM
devices, EEPROM-based devices, such as MAX® 3000 and MAX 7000 devices, and
configuration devices, such as the EPC2 and EPC16. You can also use the
MasterBlaster cable to run SignalTap® II logic analysis. The MasterBlaster cable also
provides multi-device passive serial (PS) chain configuration support for
SRAM-based devices, such as APEX 20K and Mercury devices. This cable can be used
in 2.5-, 3.3-, and 5.0-V systems.
Altera® offers a variety of hardware to program and configure Altera devices. For
conventional device programming, in-system programming, and in-circuit
reconfiguration, designers can choose from a wide range of programming hardware
options.
This user guide provides the following information about the MasterBlaster
serial/USB communications cable.
How to install the cable and its driver software
How to use the cable after installation
A complete list of the cable’s features
A functional description of the cable
Installation
The MasterBlaster communications cable connects a circuit board to the USB
(Windows 2000, Windows XP x32 edition, and Windows Vista x32 edition only) or RS-
232 serial port (called a COM port on a PC) on a PC, UNIX, or Linux workstation. The
10-pin female plug for the cable connects to a 10-pin male header on the circuit board
that contains the target device(s), as shown in Figure 1–1. Programming or
configuration data can be downloaded from the serial or USB port, using the Quartus®
II Programmer, through the MasterBlaster cable to the circuit board through these
connections.
1The Quartus II software version 8.1 and later will no longer support MasterBlaster
communication cable.
The MasterBlaster communications cable receives power from any one of the
following sources:
5.0- or 3.3-V circuit boards
5.0 V from the USB cable (Windows 2000, Windows XP x32 edition, and Windows
Vista x32 edition only)
1–2 Chapter 1: Installing the MasterBlaster Serial/USB Communications
Cable
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
DC power supply, which is supplied with the MasterBlaster communications cable
The MasterBlaster cable connects to a computer through a serial or USB port, and
connects to the circuit board through a standard 10-pin female connector.
Installation on a Windows PC
To install and set up the MasterBlaster cable for device configuration or programming
on a Windows PC, follow these steps:
1. Connect one end of a standard RS-232 cable or a standard USB cable, to the
MasterBlaster cable and connect the other end to the appropriate port on the
computer.
1If you are using the MasterBlaster communications cable with the USB port, the
Windows 2000, Windows XP, or Windows Vista operating system prompts you to
locate the MasterBlaster USB driver mblaster.inf file. The MasterBlaster driver is
located in your \<Quartus II system directory>\drivers directory.
2. Connect the 16-pin female header end of the cable to the 16-pin male MasterBlaster
port, and the 10-pin female end of the cable to the
10-pin male header on the target printed circuit board. Figure 1–1 shows the
MasterBlaster serial/USB communications cable.
3. Open the Quartus II Programmer. Choose Programmer (Tools menu) or choose
New (File menu). Click the Other Files tab, select Chain Description File, and
click OK.
4. In the Programmer window, click Hardware Setup. The Hardware Settings tab of
the Hardware Setup dialog box is displayed.
5. Click Add Hardware. The Add Hardware dialog box is displayed.
6. In the Hardware type list, select either MasterBlaster (COM) or MasterBlaster
(USB).
Figure 1–1. MasterBlaster Serial/USB Communications Cable
Chapter 1: Installing the MasterBlaster Serial/USB Communications Cable 1–3
Installation
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
1The USB option is available only for Windows 2000, Windows XP x32 edition and
Windows Vista x32 edition systems.
1The COM option is available only for Windows 2000, Windows XP x32 edition,
Windows XP x64 edition and Windows Vista x32 edition systems.
7. In the Port list, select the appropriate port.
8. If you are using a serial port, in the Baud rate list, select a baud rate appropriate
for your computer.
9. Click OK to close the Add Hardware dialog box. You will see MasterBlaster in the
Available hardware items section of the Hardware Setup dialog box.
10. Click on MasterBlaster to highlight it, then click on the Select Hardware button to
the right of the Available hardware items section. You will now see MasterBlaster
and your selected port in the Currently selected hardware section of the window,
as shown in Figure 1–2.
11. Click Close to close the Hardware Setup dialog box.
12. Close the Programmer window.
Installation on a Linux or UNIX Workstation
To install and set up the MasterBlaster cable for device configuration or programming
on a Linux or UNIX Workstation, follow these steps:
1. With a standard RS-232 cable, connect one end of the cable to the MasterBlaster
cable, and connect the other end of the cable to the appropriate port on the
computer.
2. Connect the 16-pin female header end of the cable to the 16-pin male MasterBlaster
port, and the 10-pin female end of the cable to the 10-pin male header on the target
printed circuit board, as shown in Figure 1–1.
Figure 1–2. The Hardware Setup Dialog Box
1–4 Chapter 1: Installing the MasterBlaster Serial/USB Communications
Cable
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
3. Open the Quartus II Programmer. Choose Programmer (Tools menu) or choose
New (File menu). Click the Other Files tab, select Chain Description File, and
click OK.
4. In the Programmer window, click Hardware Setup. The Hardware Settings tab of
the Hardware Setup dialog box is displayed.
5. Click Add Hardware. The Add Hardware dialog box is displayed.
6. In the Hardware type list, select MasterBlaster.
7. In the Port box, select the name of the appropriate serial port. Also, make sure you
have read and write permission for the serial port.
8. In the Baud rate list, select a baud rate that is appropriate for your computer.
9. Click OK.
10. In the Hardware Setup dialog box, click Close.
Selecting the MasterBlaster Cable for the SignalTap II Logic Analyzer
To select the MasterBlaster communications cable for the SignalTap II Logic Analyzer,
follow these steps.
1. Choose SignalTap II Logic Analyzer (Tools menu). The SignalTap window will
open.
2. Under JTAG Chain Configuration, select MasterBlaster in the Hardware
pull-down list.
If the MasterBlaster cable does not appear in the Hardware list, continue as follows:
1. Under JTAG Chain Configuration, click Setup.
2. Click Add Hardware in the Hardware Setup dialog box to add a hardware setup
for the MasterBlaster cable.
3. Click Add Hardware in the Hardware Setup dialog box to add a hardware setup
for the communications cable.
fFor more information about SignalTap II logic analysis with the MasterBlaster cable,
refer to Selecting the Communications Cable for the SignalTap II Logic Analyzer in the
Quartus II Help.
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
2. MasterBlaster Serial/USB
Communications Cable Data Sheet
Features
Supports SignalTap® II logic analysis in the Altera® Quartus® II software
Allows PC, Linux, and UNIX users to perform the following functions:
Configure Stratix®IV, Stratix III, Stratix II, Stratix II GX, Stratix, Stratix GX,
CycloneTM III, Cyclone II, Cyclone, MercuryTM, APEXTM II, APEX 20K, FLEX®
10K, FLEX 3000A, FLEX 6000, FLEX 8000 devices, and ExcaliburTM embedded
processor solutions
Program MAX®II, MAX 9000, MAX 7000S, MAX 7000B, MAX 7000A, EPC2,
EPC4, EPC8, and EPC16 devices in-system
Supports operation with VCC at 5.0 V, 3.3 V, or 2.5 V
Provides a fast, low-cost method for in-system programming
Downloads data from the Quartus II development software and the MAX+PLUS®
II software versions 9.3 and higher
Interfaces with an RS-232 serial or universal serial bus (USB) port
Uses a 10-pin circuit board connector
Functional Description
The MasterBlasterTM serial/USB communications cable (ordering code:
PL-MASTERBLASTER) is a standard PC serial or USB port hardware interface (see
Figure 2–1). This cable downloads configuration data to Stratix IV, Stratix III, Stratix
II, Stratix II GX, Stratix, Stratix GX, Cyclone III, Cyclone II, Cyclone, Mercury,
APEX II, APEX 20K (including APEX 20K, APEX 20KE, and APEX 20KC), FLEX 10K
(including FLEX 10KA and FLEX 10KE), FLEX 8000, and FLEX 6000 devices, as well
as programming data to MAX II, MAX 9000, MAX 7000S, and MAX 7000A (including
MAX 7000AE) devices. Because design changes are downloaded directly to the
device, prototyping is easy and multiple design iterations can be accomplished in
quick succession. The MasterBlaster cable also supports in-circuit debugging with the
SignalTap II embedded logic analyzer in Stratix, APEX II, and APEX 20K devices.
2–2 Chapter 2: MasterBlaster Serial/USB Communications Cable Data Sheet
Functional Description
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
Download Modes
The MasterBlaster cable provides two download modes:
Passive serial mode (PS)—In this mode the Quartus II Programmer can configure
all Altera devices supported by the Quartus II software except MAX 3000 and
MAX 7000 devices.
JTAG mode—Industry-standard IEEE Std. 1149.1 Joint Test Action Group (JTAG)
interface for programming JTAG-capable devices. In JTAG mode, the Quartus II
Programmer can program or configure all Altera devices supported by the
Quartus II software, except FLEX 6000 devices. FLEX 6000 devices can be in a
JTAG chain, but they must be bypassed; they cannot be configured. The Quartus II
Programmer can also program EPC2, EPC4, EPC8, and EPC16 configuration
devices in this mode. The JTAG chain can contain any number and combination of
Altera and non-Altera devices that comply with this IEEE 1149.1 specification.
SignalTap II Logic Analysis
The SignalTap II logic analysis enables captured device data at specified trigger points
and stores the data in APEX II and APEX 20K embedded system blocks (ESBs). This
data is then sent to the JTAG IEEE Std. 1149.1 port of an APEX II or APEX 20K device,
uploaded through the MasterBlaster communications cable, and displayed in the
Quartus II Waveform Editor.
fFor more information on SignalTap logic analysis, see the Design Debugging using the
SignalTap II Embedded Logic Analyzer chapter in volume 3 of the Quartus II Handbook.
Figure 2–1. MasterBlaster Serial/USB Communications Cable
Chapter 2: MasterBlaster Serial/USB Communications Cable Data Sheet 2–3
Functional Description
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
MasterBlaster Connections
The MasterBlaster cable connects to a computer through a serial or USB port and
connects to the circuit board through a standard 10-pin female connector. Data is
downloaded from the serial or USB port through the MasterBlaster cable to the circuit
board through the connections discussed in this section.
Header & Plug Connections
The 9-pin male D-type connector connects to an RS-232 port with a standard serial
cable. See Table 2–1.
1The USB connector can be used with any standard USB cable.
fFor more information on 9-pin versus 25-pin serial connectors, search for “9-pin or 25-
pin serial connectors” in the Altera solutions database at www.altera.com.
The 10-pin female plug connects to a 10-pin male header on the circuit board
containing the target device(s). Figure 2–2 shows the dimensions of the female plug.
Table 2–1. MasterBlaster 9-Pin Serial D-Type Connector Pin-Outs
Pin Signal Name Description
2rx Receive data
3tx Transmit data
4dtr Data terminal ready
5GND Signal ground
6dsr Data set ready
7rts Request to send
8cts Clear to send
2–4 Chapter 2: MasterBlaster Serial/USB Communications Cable Data Sheet
Functional Description
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
Table 22 identifies the 10-pin female plug’s pin names for the corresponding
download mode.
Powering the MasterBlaster Cable
The MasterBlaster cable can receive power from the following sources:
5.0- or 3.3-V circuit boards
DC power supply
5.0 V from the USB cable
Figure 2–2. MasterBlaster 10-Pin Female Plug Dimensions
Dimensions are shown in inches. The spacing between pin centers is 0.1 inches.
0.250 Typ.
0.700 Typ.
0.425 Typ.
0.100 Sq.
2
3
46
7
8
9
0.025 Sq.
C
olor Stri
p
15
10
Table 2–2. MasterBlaster Female Plug’s Pin Names & Download Modes
Pin PS Mode JTAG Mode
Signal Name Description Signal Name Description
1dclk Clock signal tck Clock signal
2gnd Signal ground gnd Signal ground
3CONF_DONE Configuration control tdo Data from device
4VCC Power supply VCC Power supply
5nCONFIG Configuration control tms JTAG state machine control
6VIO Reference voltage for
MasterBlaster output driver
VIO Reference voltage for MasterBlaster output
driver
7nstatus Configuration status No connect
8No connect No connect
9data0 Data to device tdi Data to device
10 gnd Signal ground gnd Signal ground
Chapter 2: MasterBlaster Serial/USB Communications Cable Data Sheet 2–5
Operating Conditions
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
When 5.0- or 3.3-V power is not available on the circuit board, the MasterBlaster cable can be
powered by either DC power or the USB cable.
1For the MasterBlaster cable’s output drivers, connect the circuit board’s VCC and
ground to the MasterBlaster cable’s VCC, VIO, and GND pins.
Circuit Board Header Connection
The MasterBlaster cable’s 10-pin female plug connects to a 10-pin male header on the
circuit board. The 10-pin male header has two rows of five pins, which are connected
to the device’s programming or configuration pins. Figure 2–1 shows the dimensions
of a typical 10-pin male header.
1Although a 10-pin surface mount header can be used for the JTAG, AS or PS
download cable, Altera recommends using a through-hole connector due to the
repeated insertion and removal force needed.
LED Status
The purpose of the LED indicator lights located on the MasterBlaster download cable
is to provide information about the status of the MasterBlaster cable. Table 21 lists
the indicator and status of the MasterBlaster cable.
Operating Conditions
Table 22 through 2–6 summarize the absolute maximum ratings, recommended
operating conditions, and DC operating conditions for the MasterBlaster cable.
Figure 2–1. 10-Pin Male Header Dimensions
0.025 Sq.
0.235
0.100
Side View
0.100
Top View
Table 2–1. LED Status Indicator
Color Blink Frequency Description
Green Slow Cable ready
Green Fast Performing a logic analysis
Amber Slow Programming in progress
2–6 Chapter 2: MasterBlaster Serial/USB Communications Cable Data Sheet
Operating Conditions
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
Table 2–2. MasterBlaster Cable Absolute Maximum Ratings
Symbol Parameter Conditions Min Max Unit
VCC Supply voltage With respect to ground –0.5 7.0 V
VIDC input voltage With respect to ground –0.5 7.0 V
Table 2–3. MasterBlaster Cable Recommended Operating Conditions (Note 1),(2)
Symbol Parameter Conditions Min Max Unit
VCC Board header supply voltage,
5.0-V operation
—4.55.5V
Board header supply voltage,
3.3-V operation
—3.03.6V
Notes for Table 23
(1) The DC adapter supply voltage has a minimum value of 3.0 V, a maximum value of 16.0 V, and a power consumption of 1 W (VCC can be at 5.0
V, 3.3 V, or 2.5 V).
(2) The 5.0-V USB cable supply voltage has a minimum value of 4.5 V and a maximum value of 5.5 V (VCC can be at 5.0 V, 3.3 V, or 2.5 V).
Table 2–4. MasterBlaster Cable DC Operating Conditions
Symbol Parameter Conditions Min Max Unit
VIH High-level input voltage VCC = VIO 0.25 ¥ VIO + 0.3 V V
VIL Low-level input voltage VCC = VIO 0.25 ¥ VIO V
VOH 5.0-V high-level TTL
output voltage
TTL load. VCC = VIO = 4.5 V, IOH =8mA 3.2 V
3.3-V high-level TTL
output voltage
TTL load. VCC = VIO = 3.0 V, IOH =4mA 2.4 V
5.0-V high-level CMOS output
voltage
CMOS load. VCC = VIO = 4.5 V,
IOH =0.1mA
4.0 V
3.3-V high-level CMOS output
voltage
CMOS load. VCC = VIO = 3.0 V,
IOH =0.1mA
2.7 V
2.5-V high-level CMOS output
voltage
CMOS load. VCC = VIO = 2.3 V,
IOH =0.1mA
2.0 V
VOL 5.0-V low-level TTL output
voltage
TTL load. VCC = VIO = 4.5 V, IOL =8mA 0.4 V
3.3-V low-level TTL output
voltage
TTL load. VCC = VIO = 3.0 V, IOL =4mA 0.4 V
5.0-V low-level CMOS output
voltage
CMOS load. VCC = VIO = 4.5 V,
IOL =0.1mA
0.1 V
3.3-V low-level CMOS output
voltage
CMOS load. VCC = VIO = 3.0 V,
IOL =0.1mA
0.1 V
2.5-V low-level CMOS output
voltage
CMOS load. VCC = VIO = 2.3 V,
IOL =0.1mA
0.1 V
P Operating power 1.0 W
Chapter 2: MasterBlaster Serial/USB Communications Cable Data Sheet 2–7
References
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
References
For more information on configuration and in-system programmability (ISP), see the
following sources:
The Altera Configuration Handbook
AN 95: In-System Programmability in MAX Devices
AN 100: In-System Programmability Guidelines
APEX 20K Programmable Logic Device Family Data Sheet
FLEX 10K Embedded Programmable Logic Family Data Sheet
FLEX 8000 Programmable Logic Device Family Data Sheet
FLEX 6000 Programmable Logic Device Family Data Sheet
MAX 9000 Programmable Logic Device Family Data Sheet
MAX 7000 Programmable Logic Device Family Data Sheet
MAX 7000A Programmable Logic Device Family Data Sheet
Design Debugging using the SignalTap II Embedded Logic Analyzer chapter in
volume 3 of the Quartus II Handbook
2–8 Chapter 2: MasterBlaster Serial/USB Communications Cable Data Sheet
References
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
© July 2008 Altera Corporation MasterBlaster Serial/USB Communications Cable User Guide
Info. Additional Information
Referenced Documents
Refer to the following introduction and overview topics in Quartus®II Help:
Selecting the Communications Cable for the SignalTap II Logic Analyzer
Revision History
The table below displays the revision history for the chapters in this user guide.
How to Contact Altera
For the most up-to-date information about Altera® products, refer to the following
table.
Date and
Document
Version Changes Made Summary of Changes
July 2008,
v1.1
General Style and Formatting update.
Added the “Additional Information” chapter.
Added Windows Vista to the supported operating system.
Updated the “Features” section.
Updated the “Functional Description” section.
Updated the “Download Modes” section.
July 2004,
v1.0
Initial release.
Contact (1) Contact Method Address
Technical support Website www.altera.com/support
Technical training Website www.altera.com/training
Email custrain@altera.com
Product literature Website www.altera.com/literature
Altera literature services Email literature@altera.com
Non-technical support (General)
(Software Licensing)
Email nacomp@altera.com
Email authorization@altera.com
Note to table:
(1) You can also contact your local Altera sales office or sales representative.
Info–2 Chapter Info: Additional Information
Typographic Conventions
MasterBlaster Serial/USB Communications Cable User Guide © July 2008 Altera Corporation
Typographic Conventions
This document uses the typographic conventions shown below.
Visual Cue Meaning
Bold Type with Initial Capital
Letters
Command names, dialog box titles, checkbox options, and dialog box options are shown
in bold, initial capital letters. Example: Save As dialog box.
bold type External timing parameters, directory names, project names, disk drive names, filenames,
filename extensions, and software utility names are shown in bold type. Examples: fMAX,
\qdesigns directory, d: drive, chiptrip.gdf file.
Italic Type with Initial Capital
Letters
Document titles are shown in italic type with initial capital letters. Example: AN 75:
High-Speed Board Design.
Italic type Internal timing parameters and variables are shown in italic type.
Examples: tPIA, n + 1.
Variable names are enclosed in angle brackets (< >) and shown in italic type. Example:
<file name>, <project name>.pof file.
Initial Capital Letters Keyboard keys and menu names are shown with initial capital letters. Examples: Delete
key, the Options menu.
“Subheading Title” References to sections within a document and titles of on-line help topics are shown in
quotation marks. Example: “Typographic Conventions.”
Courier type Signal and port names are shown in lowercase Courier type. Examples: data1, tdi,
input. Active-low signals are denoted by suffix n, for example, resetn.
Anything that must be typed exactly as it displays is shown in Courier type. For example:
c:\qdesigns\tutorial\chiptrip.gdf. Also, sections of an actual file, such as a
Report File, references to parts of files (for example, the AHDL keyword SUBDESIGN), as
well as logic function names (e.g., TRI) are shown in Courier.
1., 2., 3., and
a., b., c., etc.
Numbered steps are used in a list of items when the sequence of the items is important,
such as the steps listed in a procedure.
■● Bullets are used in a list of items when the sequence of the items is not important.
v The checkmark indicates a procedure that consists of one step only.
1 The hand points to information that requires special attention.
cA caution calls attention to a condition or possible situation that can damage or destroy
the product or the user’s work.
wA warning calls attention to a condition or possible situation that can cause injury to the
user.
r The angled arrow indicates you should press the Enter key.
f The feet direct you to more information about a particular topic.