Agere Systems Inc. 3
Pre liminary Data Sheet
February 2000 Erbium-Doped Fiber Amplifier
1725-Type Gain Block
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Th ese are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operational sections o f the data sheet. Exposure to absolute maximum rat ings for extended
per iods can adversely affect device reliability.
Optical Characteristics
Parameter Symbol Min Max Unit
Storage Temperature Tstg –40 85 °C
Operating Temperature TOP –5 70 °C
Bias Current First-stage Pump IBS1 —400 mA
Bias Current Seco nd-stage Pump IBS2 —800 mA
Pump Laser Reverse Voltage VR—2 V
TEC Current First-stage Pump ITECS1 —1.5 A
TEC C urrent Second-stage Pum p ITECS2 —1.6 A
Mo nitor Revers e B i a s Vol t age V RMON —10 V
Temperature S ens or Current TSEN —5 mA
Table 2a. Performance Specifi catio ns
Parameter Symbol Conditions Min Max Unit
Wavelen gth Range λ— 1530.3 1560.6 nm
EOL Optical Output P ower POUT PIN = –14 dBm 14 — dBm
Gain Flatness GF PIN = –14 d Bm,
9 dB inters tage loss —1.5dB
Noise Figure NF PIN = –14 dBm — 6.0 dB
First-stage Pump Bias IF1 — — 330 mA
Second-stage Pump Bias IF2 — — 800 mA
First-stage Pump Forward Voltage IVF1 ——2.5V
Second-stage Pump Forward Voltage IVF2 ——2.5V
First-stage Pump TEC Current ITEC1 Case temperature = 70 °C,
bias current s = EOL values —1.5A
Second-stage Pump TEC Current ITEC2 Case temperature = 70 °C,
bias current s = EOL values —1.5A
First-stage Pump TEC Voltage VTEC1 Case temperature = 70 °C,
bias current s = EOL values —3.0V
Second-stage Pump TEC Voltage VTEC2 Case temperature = 70 °C,
bias current s = EOL values —4.0V
First-stage Pump Photodetec to r Current IPD1 — 270 2500 µA
Second-stage Pump Photodetector
Current IPD2 — 100 2250 µA