02/11/2015 www.crouzet.com PBX Secure Standard83240 Part number 83240014 Dimensions according to standard DIN 41 636 type F Positive break operation mechanism according to IEC 60947-5-1 Annex K Double break changeover switch with electrically separated circuits (form Zb) IP 40 or IP 67 / IP 65 versions Operating temperature between -50 and +85 C Long overtravel Standard or Low level version Part numbers 83240014 Type Degree of protection mechanism - connection Connections / Accessories Standard83240 IP 40 - IP 00 W3 with 90 angle + Lever + Mounting plate with holes Specifications Electrical characteristics Direct opening action Rating nominal / 250 VAC (A) Rating nominal / 250 VDC (A) Rating thermal (A) Operating range / 4 30 VDC/AC (A) 6 0.6 10 - Mechanical characteristics Maximum operating force (N) Minimum positive opening force (N) Maximum rest position (mm) Operating position (mm) Positive opening position (mm) Maximum end of travel position (mm) Differential travel (mm) Operating temperature (C) Mechanical life (operations) Contact gap (mm) Max. tightening torque (Nm) Weight (g) 4,5 28 8,9 6,6 0.25 * 4,4 * 3,4 * 1 0,3 -50 +85 107 (IP40) 4x10 6 (IP 67) 2x1 1.3 on O 4.1 holes 22 * Comments * Values given for versions without lever (in relation to the reference dimension X0 - See Dimensions section). Additional characteristics Components Material - Case/cover : PC GF 20 FR. (UL 94-V0, GWFI 960 C, NFF 16-101/102 I2F1) - Contacts : AgNi for Standard version and AgPd for low level version - Terminals : Brass - Button membrane : Silicone - Screws : zinc protected steel (stainless steel on request) Conformity to standards - Construction and performance according to IEC 60947-5-1 - Positive opening operation according to IEC 60947-5-1 Annex K - Dimensions conforming to standard DIN 41 636 type F - Insulation characteristics according to standard IEC 60947-5-1 * Impulse withstand voltage : Uimp = 4 KV * Rated insulation voltage : Ui = 400 V * Pollution degree = 3 - Insulation characteristics according to standard EN 50124-1 * Impulse withstand voltage : Uimp = 2.5 KV * Rated insulation voltage : Ui = 150 V * Pollution degree = PD3A Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Principles Function Four-terminal two-way snap-action contact element (form Zb) with positive break operation. The 2 contacts are electrically separated. Dimensions (mm) Product 83240 - 83241 - 83242 - 83243 No Legend Fixing screw threaded length Fixing nuts 2 x M3 Dimensions (mm) Connections W3 for 6.35 mm x 0,8 mm female connector Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 Dimensions (mm) Connections W3 with 90 angle Dimensions (mm) Connections W5 with screws Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 02/11/2015 4 x M3 screws with saddle Dimensions (mm) Connections W5 with screws and IP20 protective covers 4 x M3 screws with saddle Dimensions (mm) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 02/11/2015 Mounting accessories Mounting plates with holes Thickness : 1 mm Dimensions (mm) Mounting accessories Mounting plates with notches Thickness : 1 mm Dimensions (mm) Actuators Roller lever Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 02/11/2015 Thickness : 1 mm Dimensions (mm) Actuators Mechanical features of lever versions Thickness : 1 mm Curves Operating curve for category AC15 Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 02/11/2015 No www.crouzet.com Legend Number of operations Current in Amps Curves Operating curve for category DC13 * For IP67 versions used in 125 V DC, please consult us. No Legend Number of operations Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Current in Amps Product coding 8324 x x x x How to order 8324Xxxx (Contact/Force) 0 : Standard/4.5N 1 : Low level/4.5N 2 : Standard/6.5N High force 3 : Low level/6.5N High force 8324xXxx (Sealing) 0 : IP 40 2 : IP 67 8324xxXx (Connection) 0 : W3 terminals for 6.35 mm female connector 1 : W3 90B terminals with 90 angle for 6.35 mm female connector 2 : W5 terminals with screw 3 : W5 terminals with screw and protective cover 4 : W5 terminals supplied without screws 8324xxxX (Accessory fitted) 0 : Without 1 : Mounting plates with holes 2 : Mounting plates with notches 3 : Roller lever (without plate) 4 : Roller lever with mounting plates with holes 5 : Roller lever with mounting plates with notches Example : A PBX with Standard contact (AgNi), 6,5 N force, IP 67 sealing, W3 terminals and Roller lever accessory with mounting plates with holes = 83242204 Accessories supplied separately : 79552459 : Mounting plates with holes 79552460 : Mounting plates with notches 79552456 : Roller lever (without plate) 79552457 : Roller lever with mounting plates with holes 79552458 : Roller lever with mounting plates with notches Product adaptations Wire outputs, cable outputs Special levers and actuators Connections : - W3 terminals with angle between 0 and 90 - special add-on terminals Special protective cover UL CSA, CCC, GOST and VDE certification on request Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 83240014