Film Capacitors Metallized Polypropylene Film Capacitors (MKP) Series/Type: B32674 ... B32678 Date: February 2017 (c) EPCOS AG 2017. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Metallized polypropylene film capacitors (MKP) MKP DC link high power series Recommended applications Frequency converters Industrial and high-end power supplies Solar inverters Climatic Max. operating temperature: 105 C (case) Climatic category (IEC 60068-1): 40/105/56 Construction Dielectric: Polypropylene (MKP) Plastic case (UL 94 V-0) Epoxy resin sealing (UL 94 V-0) Features Capacitance value up to 270 F High CV product, compact Good self-healing properties Over-voltage capability Low losses with high current capability High reliability Long useful life Terminals Parallel wire leads, lead-free tinned 2-pin, 4-pin and 12-pin versions Standard lead lengths: 6 1 mm Marking Manufacturer's logo and lot number, date code, rated capacitance (coded), capacitance tolerance (code letter), rated DC voltage Delivery mode Bulk (untaped, lead length 6 1 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 41 B32674 ... B32678 B32674 ... B32678 MKP DC link high power series Dimensional drawings Dimensions in mm Number of wires Lead spacing 0.4 Lead diameter d1 0.05 Type 2-pin 27.5 0.8 B32674D 2-pin 37.5 1.0 B32676T 4-pin 37.5 1.2 B32676G 4-pin 37.5 1.2 B32676T 4-pin 52.5 1.2 B32678G 4-pin 52.5 1.2 B32678T 12-pin 52.5 1.2 B32678J Dimensional drawings 2-pin versions B32674D Lead spacing 0.4: 27.5 Lead diameter d1: (Dimensions in mm) 0.8 B32676T (low profile) Lead spacing 0.4: 37.5 Lead diameter d1: (Dimensions in mm) Please read Cautions and warnings and Important notes at the end of this document. 1.0 Page 3 of 41 B32674 ... B32678 MKP DC link high power series Dimensional drawings 4-pin versions B32676G, B32678G B32676G B32678G Lead spacing 0.4: 37.5 52.5 Lead diameter d1: 1.2 1.2 (Dimensions in mm) B32676T, B32678T (low profile) B32676T B32678T Lead spacing 0.4: 37.5 52.5 Lead diameter d1: 1.2 1.2 (Dimensions in mm) Dimensional drawing 12-pin version B32678J Lead spacing 0.4: 52.5 Lead diameter d1: (Dimensions in mm) Please read Cautions and warnings and Important notes at the end of this document. 1.2 Page 4 of 41 B32674 ... B32678 MKP DC link high power series Overview of available types Lead spacing 27.5 mm 37.5 mm Type B32674 B32676 Page 7 VR (V DC) 300 9 450 630 750 875 CR (F) 0.47 0.68 1.0 1.5 2.0 2.2 2.7 3.0 3.3 3.5 4.0 4.7 5.0 5.6 6.0 6.2 6.8 7.5 8.0 8.2 9.0 10 12 13 14 15 20 22 25 30 35 Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 41 300 450 630 750 875 B32674 ... B32678 MKP DC link high power series Lead spacing 52.5 mm Type B32678 Page 11 VR (V DC) 300 450 630 CR (F) 7.0 9.0 13 15 20 22 24 25 28 30 35 38 40 45 47 60 65 80 85 100 120 180 270 Please read Cautions and warnings and Important notes at the end of this document. Page 6 of 41 750 875 B32674 MKP DC link high power series Ordering codes and packing units (lead spacing 27.5 mm) CR1) Max. dimensions wxhxl P1 F mm mm Ordering code (composition see below) VR,85 C = 300 V DC, Vop,70 C = 450 V DC 2.2 11.0 x 19.0 x 31.5 B32674D3225+000 3.3 12.5 x 21.5 x 31.5 B32674D3335+000 4.7 14.0 x 24.5 x 31.5 B32674D3475+000 5.0 15.0 x 24.5 x 31.5 B32674D3505+000 6.8 18.0 x 27.5 x 31.5 B32674D3685+000 8.0 16.0 x 32.0 x 31.5 B32674D3805+000 8.2 18.0 x 33.0 x 31.5 B32674D3825+000 10.0 21.0 x 31.0 x 31.5 B32674D3106+000 12.0 22.0 x 36.5 x 31.5 B32674D3126+000 VR,85 C = 450 V DC, Vop,70 C = 630 V DC 1.5 11.0 x 19.0 x 31.5 B32674D4155+000 2.2 12.5 x 21.5 x 31.5 B32674D4225+000 3.3 15.0 x 24.5 x 31.5 B32674D4335+000 4.7 18.0 x 27.5 x 31.5 B32674D4475+000 5.0 16.0 x 32.0 x 31.5 B32674D4505+000 5.6 18.0 x 33.0 x 31.5 B32674D4565+000 6.0 21.0 x 31.0 x 31.5 B32674D4605+000 6.8 22.0 x 36.5 x 31.5 B32674D4685+000 7.5 22.0 x 36.5 x 31.5 B32674D4755+000 VR,85 C = 630 V DC, Vop,70 C = 800 V DC 1.0 11.0 x 19.0 x 31.5 B32674D6105+000 1.5 12.5 x 21.5 x 31.5 B32674D6155+000 2.2 15.0 x 24.5 x 31.5 B32674D6225+000 3.3 16.0 x 32.0 x 31.5 B32674D6335+000 4.7 22.0 x 36.5 x 31.5 B32674D6475+000 5.0 22.0 x 36.5 x 31.5 B32674D6505+000 IRMS,max2) 70 C 10 kHz A ESRtyp ESLtyp3) tan tan MOQ 70 C 10 kHz 1 kHz 10 kHz m nH 10-3 10-3 pcs. 5.0 7.0 8.5 9.0 11.5 12.5 13.0 14.5 17.0 18.1 12.2 8.9 8.4 6.3 5.6 5.5 4.6 4.0 16.0 19.0 21.0 21.0 24.0 27.0 27.0 27.0 31.0 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.8 0.8 4.1 4.1 4.2 4.2 4.4 4.5 4.5 4.6 4.9 1280 1120 1040 960 800 880 800 720 640 4.5 6.0 8.0 10.5 11.0 12.0 13.0 14.5 15.0 22.1 14.9 10.3 7.5 7.1 6.3 5.9 5.4 5.0 16.0 19.0 22.0 24.0 28.0 29.0 28.0 29.0 32.0 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 3.3 3.3 3.4 3.5 3.6 3.6 3.6 3.7 3.8 1280 1120 960 800 880 800 720 640 640 4.0 5.5 7.5 10.0 13.5 14.5 26.1 17.9 12.4 8.5 6.0 5.8 17.0 19.0 21.0 28.0 31.0 31.0 0.6 0.6 0.6 0.6 0.6 0.6 2.7 2.7 2.7 2.8 3.0 3.0 1280 1120 960 880 640 640 MOQ = Minimum Order Quantity, consisting of 4 packing units. Intermediate capacitance values are available on request. Composition of ordering code + = Capacitance tolerance code: K = 10% J = 5% 1) Capacitance value measured at 1 kHz 2) Max. ripple current IRMS at 70 C at 10 kHz for a T 20 C when ESRtyp 5% 3) ESL value measured at resonance frequency (see specific graphs of Z vs freq) Please read Cautions and warnings and Important notes at the end of this document. Page 7 of 41 B32674 MKP DC link high power series Ordering codes and packing units (lead spacing 27.5 mm) CR4) Max. dimensions wxhxl P1 F mm mm Ordering code (composition see below) IRMS,max5) 70 C 10 kHz A VR,85 C = 750 V DC, Vop,70 C = 900 V DC 0.68 11.0 x 19.0 x 31.5 B32674D1684+000 3.5 1.0 12.5 x 21.5 x 31.5 B32674D1105+000 4.5 1.5 14.0 x 24.5 x 31.5 B32674D1155+000 6.5 2.2 18.0 x 27.5 x 31.5 B32674D1225+000 8.5 3.3 21.0 x 31.0 x 31.5 B32674D1335+000 11.0 4.0 22.0 x 36.5 x 31.5 B32674D1405+000 13.0 VR,85 C = 875 V DC, Vop,70 C = 1050 V DC 0.47 11.0 x 19.0 x 31.5 B32674D8474+000 3.0 0.68 11.0 x 21.0 x 31.5 B32674D8684+000 4.0 1.0 13.5 x 23.0 x 31.5 B32674D8105+000 5.0 1.5 18.0 x 27.5 x 31.5 B32674D8155+000 7.5 2.2 18.0 x 33.0 x 31.5 B32674D8225+000 9.5 3.0 22.0 x 36.5 x 31.5 B32674D8305+000 12.0 ESRtyp ESLtyp6) tan tan MOQ 70 C 10 kHz 1 kHz 10 kHz m nH 10-3 10-3 pcs. 34.7 24.2 16.3 11.3 7.9 6.7 17.0 18.0 22.0 24.0 28.0 32.0 0.5 0.5 0.6 0.6 0.6 0.6 2.4 2.5 2.5 2.5 2.6 2.7 1280 1120 1040 800 720 640 45.2 31.5 22.2 14.7 10.3 7.8 16.0 19.0 20.0 23.0 29.0 31.0 0.5 0.5 0.5 0.5 0.5 0.5 2.2 2.2 2.2 2.2 2.3 2.4 1280 1280 1040 800 800 640 MOQ = Minimum Order Quantity, consisting of 4 packing units. Intermediate capacitance values are available on request. Composition of ordering code + = Capacitance tolerance code: K = 10% J = 5% 4) Capacitance value measured at 1 kHz 5) Max. ripple current IRMS at 70 C at 10 kHz for a T 20 C when ESRtyp 5% 6) ESL value measured at resonance frequency (see specific graphs of Z vs freq) Please read Cautions and warnings and Important notes at the end of this document. Page 8 of 41 B32676 MKP DC link high power series Ordering codes and packing units (lead spacing 37.5 mm) CR1) Max. dimensions wxhxl P1 F mm mm VR,85 C = 300 V DC, Vop,70 C = 6.2 24.0 x 15.0 x 41.5 9.0 24.0 x 19.0 x 41.5 15.0 20.0 x 39.5 x 42.0 10.2 20.0 28.0 x 37.0 x 42.0 10.2 20.0 43.0 x 22.0 x 41.5 20.3 22.0 28.0 x 42.5 x 42.0 10.2 25.0 28.0 x 42.5 x 42.0 10.2 30.0 30.0 x 45.0 x 42.0 20.3 35.0 33.0 x 48.0 x 42.0 20.3 VR,85 C = 450 V DC, Vop,70 C = 4.0 24.0 x 15.0 x 41.5 4.7 24.0 x 19.0 x 41.5 8.2 20.0 x 39.5 x 42.0 10.2 10.0 20.0 x 39.5 x 42.0 10.2 13.0 43.0 x 22.0 x 41.5 20.3 15.0 28.0 x 42.5 x 42.0 10.2 20.0 30.0 x 45.0 x 42.0 20.3 25.0 33.0 x 48.0 x 42.0 20.3 VR,85 C = 630 V DC, Vop,70 C = 2.7 24.0 x 15.0 x 41.5 3.5 24.0 x 19.0 x 41.5 6.8 20.0 x 39.5 x 42.0 10.2 7.5 20.0 x 39.5 x 42.0 10.2 8.2 28.0 x 37.0 x 42.0 10.2 9.0 43.0 x 22.0 x 41.5 20.3 10.0 28.0 x 42.5 x 42.0 10.2 12.0 28.0 x 42.5 x 42.0 10.2 14.0 30.0 x 45.0 x 42.0 20.3 15.0 33.0 x 48.0 x 42.0 20.3 Ordering code (composition see below) 450 V DC B32676T3625+000 B32676T3905+000 B32676G3156+000 B32676G3206+000 B32676T3206K000 B32676G3226+000 B32676G3256+000 B32676G3306+000 B32676G3356+000 630 V DC B32676T4405+000 B32676T4475+000 B32676G4825+000 B32676G4106+000 B32676T4136K000 B32676G4156+000 B32676G4206K000 B32676G4256K000 800 V DC B32676T6275+000 B32676T6355+000 B32676G6685+000 B32676G6755+000 B32676G6825+000 B32676T6905K000 B32676G6106+000 B32676G6126+000 B32676G6146+000 B32676G6156+000 IRMS,max2) 70 C 10 kHz A ESRtyp ESLtyp3) tan tan MOQ 70 C 10 kHz 1 kHz 10 kHz m nH 10-3 10-3 pcs. 8.0 10.0 16.0 20.0 19.5 21.5 22.5 26.0 29.5 12.6 9.1 5.4 4.0 4.0 3.8 3.4 2.8 2.5 18.0 19.0 10.0 11.0 13.0 11.0 12.0 12.0 13.0 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.2 1.2 8.2 8.3 8.3 8.4 8.3 8.5 8.6 8.7 8.8 1040 780 640 440 280 440 440 400 180 7.0 8.0 13.5 14.5 17.5 20.0 24.0 28.0 15.5 13.2 7.8 6.4 5.0 4.4 3.3 2.8 19.0 18.0 9.0 11.0 13.0 11.0 13.0 14.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 6.6 6.6 6.7 6.7 6.6 6.8 6.9 7.1 1040 780 640 640 280 440 400 180 7.0 8.0 13.5 14.5 16.0 16.5 18.5 20.0 23.0 25.0 17.7 14.1 7.4 6.6 6.1 5.7 5.1 4.4 3.7 3.5 20.0 19.0 10.0 12.0 11.0 13.0 11.0 12.0 14.0 14.0 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 5.1 5.1 5.2 5.2 5.2 5.1 5.2 5.3 5.3 5.4 1040 780 640 640 440 280 440 440 400 180 MOQ = Minimum Order Quantity, consisting of 4 packing units. Intermediate capacitance values are available on request. Composition of ordering code + = Capacitance tolerance code: K = 10% J = 5% 1) Capacitance value measured at 1 kHz 2) Max. ripple current IRMS at 70 C at 10 kHz for a T 20 C when ESRtyp 5% 3) ESL value measured at resonance frequency (see specific graphs of Z vs freq) Please read Cautions and warnings and Important notes at the end of this document. Page 9 of 41 B32676 MKP DC link high power series Ordering codes and packing units (lead spacing 37.5 mm) CR4) Max. dimensions wxhxl P1 F mm mm Ordering code (composition see below) VR,85 C = 750 V DC, Vop,70 C = 900 V DC 2.0 24.0 x 15.0 x 41.5 B32676T1205+000 2.7 24.0 x 19.0 x 41.5 B32676T1275+000 4.7 20.0 x 39.5 x 42.0 10.2 B32676G1475+000 5.6 20.0 x 39.5 x 42.0 10.2 B32676G1565+000 6.8 28.0 x 37.0 x 42.0 10.2 B32676G1685+000 9.0 30.0 x 45.0 x 42.0 20.3 B32676G1905+000 10.0 30.0 x 45.0 x 42.0 20.3 B32676G1106+000 12.0 33.0 x 48.0 x 42.0 20.3 B32676G1126+000 VR,85 C = 875 V DC, Vop,70 C = 1050 V DC 1.5 24.0 x 15.0 x 41.5 B32676T8155+000 2.0 24.0 x 19.0 x 41.5 B32676T8205+000 3.3 20.0 x 39.5 x 42.0 10.2 B32676G8335+000 4.0 20.0 x 39.5 x 42.0 10.2 B32676G8405+000 4.7 28.0 x 37.0 x 42.0 10.2 B32676G8475+000 6.8 28.0 x 42.5 x 42.0 10.2 B32676G8685+000 7.5 30.0 x 45.0 x 42.0 20.3 B32676G8755+000 10.0 33.0 x 48.0 x 42.0 20.3 B32676G8106K000 IRMS,max5) 70 C 10 kHz A ESRtyp ESLtyp6) tan tan MOQ 70 C 10 kHz 1 kHz 10 kHz m nH 10-3 10-3 pcs. 6.0 7.5 12.0 13.0 15.5 19.5 20.5 23.0 22.7 16.7 9.5 8.2 6.7 5.1 4.7 4.0 18.0 19.0 10.0 11.0 11.0 12.0 13.0 14.0 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 4.6 4.6 4.6 4.7 4.7 4.7 4.8 4.8 1040 780 640 640 440 440 400 180 5.5 7.0 10.5 12.0 13.5 17.0 19.0 22.5 26.2 19.6 12.0 9.9 8.6 6.0 5.4 4.3 18.0 19.0 9.0 11.0 10.0 12.0 13.0 14.0 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 4.1 4.1 4.1 4.1 4.1 4.2 4.2 4.3 1040 780 640 640 440 440 400 180 MOQ = Minimum Order Quantity, consisting of 4 packing units. Intermediate capacitance values are available on request. Composition of ordering code + = Capacitance tolerance code: K = 10% J = 5% 4) Capacitance value measured at 1 kHz 5) Max. ripple current IRMS at 70 C at 10 kHz for a T 20 C when ESRtyp 5% 6) ESL value measured at resonance frequency (see specific graphs of Z vs freq) Please read Cautions and warnings and Important notes at the end of this document. Page 10 of 41 B32678 MKP DC link high power series Ordering codes and packing units (lead spacing 52.5 mm) CR1) Max. dimensions wxhxl P1 F mm mm Ordering code (composition see below) IRMS,max2) 70 C 10 kHz A VR,85 C = 300 V DC, Vop,70 C = 450 V DC 30.0 43.0 x 24.0 x 57.5 20.3 B32678T3306K000 22.5 40.0 30.0 x 45.0 x 57.5 20.3 B32678G3406+000 28.0 47.0 35.0 x 50.0 x 57.5 20.3 B32678G3476+000 33.0 60.0 35.0 x 50.0 x 57.5 20.3 B32678G3606K000 37.0 80.0 45.0 x 57.0 x 57.5 20.3 B32678G3806+000 47.0 80.0 130.0 x 24.0 x 57.5 20.3 B32678J3806K000 51.0 100.0 60.0 x 45.0 x 57.5 20.3 B32678G3107+000 48.0 270.0 130.0 x 58.0 x 57.5 20.3 B32678J3277K000 108.0 VR,85 C = 450 V DC, Vop,70 C = 630 V DC 20.0 43.0 x 24.0 x 57.5 20.3 B32678T4206K000 20.0 30.0 35.0 x 50.0 x 57.5 20.3 B32678G4306+000 28.0 35.0 35.0 x 50.0 x 57.5 20.3 B32678G4356+000 31.5 40.0 35.0 x 50.0 x 57.5 20.3 B32678G4406K000 34.0 60.0 45.0 x 57.0 x 57.5 20.3 B32678G4606+000 45.0 60.0 130.0 x 24.0 x 57.5 20.3 B32678J4606K000 49.5 65.0 60.0 x 45.0 x 57.5 20.3 B32678G4656+000 48.0 180.0 130.0 x 58.0 x 57.5 20.3 B32678J4187K000 97.5 VR,85 C = 630 V DC, Vop,70 C = 800 V DC 13.0 43.0 x 24.0 x 57.5 20.3 B32678T6136K000 18.0 20.0 35.0 x 50.0 x 57.5 20.3 B32678G6206+000 26.5 25.0 35.0 x 50.0 x 57.5 20.3 B32678G6256+000 29.5 38.0 130.0 x 24.0 x 57.5 20.3 B32678J6386K000 43.5 40.0 45.0 x 57.0 x 57.5 20.3 B32678G6406+000 41.0 45.0 60.0 x 45.0 x 57.5 20.3 B32678G6456+000 43.0 120.0 130.0 x 58.0 x 57.5 20.3 B32678J6127K000 90.0 ESRtyp ESLtyp3) tan tan MOQ 70 C 10 kHz 1 kHz 10 kHz m nH 10-3 10-3 pcs. 3.9 3.0 2.6 2.1 1.6 1.4 1.4 0.5 13.0 12.0 13.0 15.0 18.0 4.0 19.0 6.0 1.5 1.5 1.5 1.6 1.6 1.5 1.6 1.6 11.8 12.3 12.5 12.9 13.5 11.7 13.5 13.8 420 280 108 108 140 80 200 40 4.9 3.2 2.8 2.5 1.8 1.6 1.6 0.6 13.0 14.0 14.0 15.0 18.0 4.0 19.0 6.0 1.3 1.3 1.3 1.3 1.4 1.2 1.3 1.4 9.8 9.9 10.0 10.2 11.2 9.5 10.6 11.2 420 108 108 108 140 80 200 40 5.9 4.0 3.3 2.1 2.1 1.9 0.7 13.0 13.0 15.0 4.0 18.0 19.0 6.0 1.1 1.1 1.1 1.1 1.2 1.2 1.2 7.9 8.2 8.3 7.9 8.8 8.7 8.8 420 108 108 80 140 200 40 MOQ = Minimum Order Quantity, consisting of 4 packing units. Intermediate capacitance values are available on request. Composition of ordering code + = Capacitance tolerance code: K = 10% J = 5% 1) Capacitance value measured at 1 kHz 2) Max. ripple current IRMS at 70 C at 10 kHz for a T 20 C when ESRtyp 5% 3) ESL value measured at resonance frequency (see specific graphs of Z vs freq) Please read Cautions and warnings and Important notes at the end of this document. Page 11 of 41 B32678 MKP DC link high power series Ordering codes and packing units (lead spacing 52.5 mm) CR4) Max. dimensions wxhxl P1 F mm mm Ordering code (composition see below) VR,85 C = 750 V DC, Vop,70 C = 900 V DC 9.0 43.0 x 24.0 x 57.5 20.3 B32678T1905K000 15.0 30.0 x 45.0 x 57.5 20.3 B32678G1156K000 20.0 35.0 x 50.0 x 57.5 20.3 B32678G1206K000 28.0 45.0 x 57.0 x 57.5 20.3 B32678G1286+000 30.0 60.0 x 45.0 x 57.5 20.3 B32678G1306+000 30.0 130.0 x 24.0 x 57.5 20.3 B32678J1306K000 85.0 130.0 x 58.0 x 57.5 20.3 B32678J1856K000 VR,85 C = 875 V DC, Vop,70 C = 1050 V DC 7.0 43.0 x 24.0 x 57.5 20.3 B32678T8705K000 15.0 35.0 x 50.0 x 57.5 20.3 B32678G8156K000 22.0 45.0 x 57.0 x 57.5 20.3 B32678G8226+000 22.0 130.0 x 24.0 x 57.5 20.3 B32678J8226K000 24.0 60.0 x 45.0 x 57.5 20.3 B32678G8246+000 65.0 130.0 x 58.0 x 57.5 20.3 B32678J8656K000 IRMS,max5) 70 C 10 kHz A ESRtyp ESLtyp6) tan tan MOQ 70 C 10 kHz 1 kHz 10 kHz m nH 10-3 10-3 pcs. 16.5 23.0 28.0 37.5 39.5 40.5 82.5 7.2 4.5 3.5 2.5 2.4 2.3 0.9 13.0 14.0 15.0 18.0 19.0 4.0 6.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 6.8 7.0 7.2 7.4 7.3 6.8 7.4 420 280 108 140 200 80 40 15.5 26.5 35.0 39.0 38.0 78.0 8.2 4.0 2.9 2.6 2.6 1.0 13.0 15.0 17.0 5.0 19.0 6.0 0.9 0.9 1.0 0.9 0.9 1.0 6.0 6.3 6.5 6.0 6.4 6.5 420 108 140 80 200 40 MOQ = Minimum Order Quantity, consisting of 4 packing units. Intermediate capacitance values are available on request. Composition of ordering code + = Capacitance tolerance code: K = 10% J = 5% 4) Capacitance value measured at 1 kHz 5) Max. ripple current IRMS at 70 C at 10 kHz for a T 20 C when ESRtyp 5% 6) ESL value measured at resonance frequency (see specific graphs of Z vs freq) Please read Cautions and warnings and Important notes at the end of this document. Page 12 of 41 B32674 ... B32678 MKP DC link high power series Technical data Reference standard: IEC 61071. All data given at T = 20 C, unless otherwise specified. Max. operating temperature, Top,max +105 C Operating temperature range (case) Upper category temperature Tmax +105 C Lower category temperature Tmin 40 C Insulation Resistance Rins > 10000 s (after 1 min) given as time constant For VR 500 V measured at 500 V = CR Rins, rel. humidity 65% For VR < 500 V measured at VR (minimum as-delivered values) DC voltage test between terminals (10 s) 1.5 VR Voltage test terminal to case (10 s) 2110 V AC, 50 Hz Pulse Handling Capability (V/s) IP (A) / C (F) Damp heat test 56 days/40 C/93% relative humidity Limit values after damp heat test Capacitance change |C/C| 5% Dissipation factor change tan 0.005 (at 1 kHz) 50% of minimum Insulation resistance Rins as-delivered values Reliability: Failure rate 1 fit ( 1 10-9/h) at 0.5 VR, 40 C 200 000 h at VR, 85 C Service life tSL For conversion to other operating conditions and temperatures, refer to chapter "Quality, 2 Reliability". VR (V DC) 300 450 630 750 875 Continuous operation voltage Vop (V DC) at 70 C 450 630 800 900 1050 Continuous operation voltage Vop (V DC) at 85 C 300 450 630 750 875 For temperatures between 1.2%/C of Vop de-rating compared to Vop at 85 C 85 C and 100 C Please read Cautions and warnings and Important notes at the end of this document. Page 13 of 41 B32674 ... B32678 MKP DC link high power series Typical waveforms Restrictions: VR: Maximum operating peak voltage of either polarity but of a non-reversing waveform, for which the capacitor has been designed for continuous operation. uAC 0.2 VR Vp, max: Overvoltage Maximum duration within one day 1.1 VR 1.15 VR 1.2 VR 1.3 VR 30% of on-load duration 30 min. 5 min. 1 min. Observation System regulation System regulation System regulation System regulation NOTE 1 An overvoltage equal to 1.5 VR for 30 ms is permitted 1000 times during the life of the capacitor. The amplitudes of the overvoltages that may be tolerated without significant reduction in the life time of the capacitor depend on their duration, the number of application and the capacitor temperature. In addition these values assume that the overvoltages may appear when the internal temperature of the capacitor is less than 0 C but within the temperature category. NOTE 2 The average applied voltage must not be higher than the specified voltage. Pulse handling capability "dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal voltages, expressed in V/s. Note: The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the capacitor. These parameters are given for isolated pulses in such a way that the heat generated by one pulse will be completely dissipated before applying the next pulse. For a train of pulses, please refer to the curves of permissible AC voltage-current versus frequency. dV/dt values Lead spacing Type VR (V DC) dV/dt in V/s 27.5 mm 37.5 mm 52.5 mm B32674 B32676 B32678 300 450 630 750 875 300 450 630 750 875 300 450 630 750 875 40 75 100 125 150 22 54 73 85 100 15 35 50 60 70 Please read Cautions and warnings and Important notes at the end of this document. Page 14 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Additional technical information can be found under "Design support" on www.epcos.com Impedance Z versus frequency f (typical values) Lead spacing 27.5 mm / B32674D3x / 300 V DC ESR versus frequency f (typical values) Lead spacing 27.5 mm / B32674D3x / 300 V DC Impedance Z versus frequency f (typical values) Lead spacing 27.5 mm / B32674D4x / 450 V DC ESR versus frequency f (typical values) Lead spacing 27.5 mm / B32674D4x / 450 V DC Please read Cautions and warnings and Important notes at the end of this document. Page 15 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Impedance Z versus frequency f (typical values) Lead spacing 27.5 mm / B32674D6x / 630 V DC ESR versus frequency f (typical values) Lead spacing 27.5 mm / B32674D6x / 630 V DC Impedance Z versus frequency f (typical values) Lead spacing 27.5 mm / B32674D1x / 750 V DC ESR versus frequency f (typical values) Lead spacing 27.5 mm / B32674D1x / 750 V DC Please read Cautions and warnings and Important notes at the end of this document. Page 16 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Impedance Z versus frequency f (typical values) Lead spacing 27.5 mm / B32674D8x / 875 V DC Please read Cautions and warnings and Important notes at the end of this document. ESR versus frequency f (typical values) Lead spacing 27.5 mm / B32674D8x / 875 VDC Page 17 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Impedance Z versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T3x / 300 V DC ESR versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T3x / 300 V DC Impedance Z versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T4x / 450 V DC ESR versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T4x / 450 V DC Please read Cautions and warnings and Important notes at the end of this document. Page 18 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Impedance Z versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T6x / 630 V DC ESR versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T6x / 630 V DC Impedance Z versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T1x / 750 V DC ESR versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T1x / 750 V DC Please read Cautions and warnings and Important notes at the end of this document. Page 19 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Impedance Z versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T8x / 875 V DC Please read Cautions and warnings and Important notes at the end of this document. ESR versus frequency f (typical values) Lead spacing 37.5 mm / B32676G/T8x / 875 V DC Page 20 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Impedance Z versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T3x / 300 V DC ESR versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T3x / 300 V DC Impedance Z versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T4x / 450 V DC ESR versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T4x / 450 V DC Please read Cautions and warnings and Important notes at the end of this document. Page 21 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Impedance Z versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T6x / 630 V DC ESR versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T6x / 630 V DC Impedance Z versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T1x / 750 V DC ESR versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T1x / 750 V DC Please read Cautions and warnings and Important notes at the end of this document. Page 22 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Impedance Z versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T8x / 875 V DC ESR versus frequency f (typical values) Lead spacing 52.5 mm / B32678G/T8x / 875 V DC Impedance Z versus frequency f (typical values) Lead spacing 52.5 mm / B32678Jx / 300 V DC, 450 V DC, 630 V DC, 750 V DC, 875 V DC ESR versus frequency f (typical values) Lead spacing 52.5 mm / B32678Jx / 300 V DC, 450 V DC, 630 V DC, 750 V DC, 875 V DC Please read Cautions and warnings and Important notes at the end of this document. Page 23 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Permissible current IRMS versus frequency f at 70 C Lead spacing 27.5 mm B32674-Dx Permissible current IRMS versus frequency f at 70 C Lead spacing 37.5 mm B32676-G/Tx Please read Cautions and warnings and Important notes at the end of this document. Page 24 of 41 B32674 ... B32678 MKP DC link high power series Characteristics curves Permissible current IRMS versus frequency f at 70 C Lead spacing 52.5 mm B32678-G/Tx Permissible current IRMS versus frequency f at 70 C Lead spacing 52.5 mm B32678-Jx Please read Cautions and warnings and Important notes at the end of this document. Page 25 of 41 B32674 ... B32678 MKP DC link high power series Curves Characteristics (IRMS derating vs temperature) Maximum IRMS current as function of the ambient temperature: IRMS (TA) = Factor x IRMS (70 C) Please read Cautions and warnings and Important notes at the end of this document. Page 26 of 41 B32674 ... B32678 MKP DC link high power series Heat transference for self heating calculation Box dimensions w (mm) Figure 1 (2-pin, 4-pin) Figure 2 (12-pin) h (mm) l (mm) Equivalent heat coefficient G (mW/C) 11.0 11.0 12.5 13.5 14.0 15.0 16.0 18.0 18.0 19.0 20.0 21.0 22.0 19.0 21.0 21.5 23.0 24.5 24.5 32.0 27.5 33.0 30.0 11.0 31.0 36.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 25 28 30 32 35 36 45 44 48 48 65 51 58 12.0 14.0 16.0 18.0 20.0 24.0 24.0 28.0 28.0 30.0 33.0 43.0 30.0 35.0 43.0 45.0 60.0 130.0 130.0 22.0 25.0 28.5 32.5 39.5 19.0 15.0 37.0 42.5 45.0 48.0 22.0 45.0 50.0 24.0 57.0 45.0 24.0 58.0 41.5 41.5 41.5 41.5 42.0 41.5 41.5 42.0 42.0 42.0 42.0 41.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5 70 43 50 59 72 50 44 83 90 100 110 80 125 145 103 185 192 200 300 The equivalent heat coefficient "G (mW/C)" is given for measuring the temperature on the lateral surface of the plastic box as figure1 shows. By using a thermocouple and avoiding effect of radiation and convection the temperature measured during operation conditions should be a result of the dissipated power divided by the equivalent heat coefficient. Please read Cautions and warnings and Important notes at the end of this document. Page 27 of 41 B32674 ... B32678 MKP DC link high power series Self Heating by power dissipation and equivalent heat coefficient The IRMS and consequently the power dissipation must be limited during operation in order to not exceed the maximum limit of T allowed for this series. Tmax given for this series is equal or lower than 20 C at rated temperature (70 C), for higher ambient temperatures Tmax (T) will have the same derating factor than IRMS vs temperature and then an equivalent derating as per: Tmax (T) = (Factor)2 x T (70 C). For any particular IRMS the T may be calculated by: T (C) = Pdis (mW) / G(mW/C). Where T (C) is the difference between the temperature measured on the box (see figure 1) and the ambient temperature when capacitor is working during normal operation; T (C) = Top (C) TA (C). It represents the increasing of temperature provoked by the IRMS during operation. G (mW/C) is the equivalent heat coefficient described above and Pdis (mW) is the dissipated power defined by: Pdis (mW) = ESRtyp (m) x IRMS2 (ARMS). Example for thermal calculation: We will take as reference B32678G8156K (15 F/875 V) type for thermal calculation. Considering the following load and capacitor characteristics: IRMS: 15 ARMS at 20 kHz TA: 85 C 35 x 50 x 57.5 box G (mW/C): 145 Then we have to find the ESRtyp at 20 kHz what is approximately 4.0 m. So according to Pdis (mW) = ESRtyp (m) x IRMS 2 (ARMS) we have the following: Pdis (mW) = 4.0 m x15 ARMS2 = 900 mW. And as per T (C) = Pdis (mW) / G (mW/C) we have the following: T (C) = 900 (mW) / 145 (mW/C) = 6.2 C. What is below of the Tmax (85 C) = (Factor)2 x T (70 C) = (0.7)2 x 20 C = 9.8 C. On the other hand we may confirm that max IRMS at 20 kHz at 70 C = 26.5 ARMS. And then max IRMS for 85 C of ambient temperature is defined as follows: IRMS (85 C) = Factor x IRMS (70 C) = 0.7 x 26.5 ARMS = 18.55 ARMS. What confirms once again that IRMS (15 ARMS at 20 kHz at 85 C) is below the max specified for such frequency and ambient temperature. Please read Cautions and warnings and Important notes at the end of this document. Page 28 of 41 B32674 ... B32678 MKP DC link high power series Life time expectancy - typical curve (300 V DC / 450 V DC / 630 V DC / 750 V DC / 875 V DC / B3267X-3/4/6/1/8) Note: Confidence level of 98% Please read Cautions and warnings and Important notes at the end of this document. Page 29 of 41 B32674 ... B32678 MKP DC link high power series Testing and Standards Test Reference Electrical Parameters (Routine test) IEC 61071-11 Robustness of terminations (Type test) Resistance to soldering heat (Type test) Conditions of test Voltage between terminals, 1.5 VR, during 10 s Insulation resistance, RINS at VR if VR < 500 V or 500 V if VR 500 V Capacitance, C at 1 kHz (room temperature) Dissipation factor, tan at 1/10 kHz (room temperature) IEC 60068-2-21 Tensile strength (test Ua1) Tensile Wire diameter force 0.5 < d1 0.8 mm 10 N 0.8 < d1 1.25 mm 20 N IEC 60068-2-20, Solder bath temperature at test Tb, 260 5 C, immersion for method 1A 10 seconds Performance requirements Within specified limits Capacitance and tan within specified limits C/C0 2% I tan l 0.002 IC/C0 I 2% I tan I 0.002 RINS 50% of initial limit Rapid change of IEC 60384-16 temperature (Type test) TA = lower category temperature TB = upper category temperature Five cycles, duration t = 30 min. Vibration (Type test) IEC 60384-16 Bump (Type test) IEC 60384-16 Climatic sequence (Type test) IEC 60384-16 Damp Heat Steady State (Type test) IEC 60384-16 Test FC: vibration sinusoidal No visible damage Displacement: 0.75 mm Accleration: 98 m/s2 Frequency: 10 Hz ... 500 Hz Test duration: 3 orthogonal axes, 2 hours each axe Test Eb: Total 4000 bumps with No visible damage IC/C0 I 2% 390 m/s2 mounted on PCB I tan I 0.002 6 ms duration RINS 50% of initial limit Dry heat Tb / 16 h. No visible damage Damp heat cyclic, 1st cycle IC/C0 I 3% + 55 C / 24h / 95% ... 100% RH I tan I 0.001 Cold Ta / 2h RINS 50% of initial limit Damp heat cyclic, 5 cycles + 55 C / 24h / 95% ... 100% RH Test Ca No visible damage 40 C / 93% RH / 56 days IC/C0 I 5% I tan I 0.005 RINS 50% of initial limit Please read Cautions and warnings and Important notes at the end of this document. Page 30 of 41 B32674 ... B32678 MKP DC link high power series Test Reference Conditions of test Endurance (Type test) IEC 61071-11 Endurance (Type test) IEC 60384-16 70 C / 1.4 VR / 250 hours or Top / 1.4 Vop / 250 hours + 1000 discharges at 1.4 IR + 70 C / 1.4 VR / 250 hours or Top / 1.4 Vop / 250 hours 70 C / 1.25 VR / 1000 hours or 85 C / 1.25 Vop / 1000 hours or 100 C / 1.25 Vop / 1000 hours Performance requirements No visible damage IC/C0 I 3% at 1 kHz I tan I 0.015 at 10 kHz No visible damage IC/C0 I 5% at 1 kHz I tan I 0.005 RINS 50% of initial limit Mounting guidelines 1 Soldering 1.1 Solderability of leads The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1. Before a solderability test is carried out, terminals are subjected to accelerated ageing (to IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 C). Since the ageing temperature is far higher than the upper category temperature of the capacitors, the terminal wires should be cut off from the capacitor before the ageing procedure to prevent the solderability being impaired by the products of any capacitor decomposition that might occur. Solder bath temperature 235 5 C Soldering time 2.0 0.5 s Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane Evaluation criteria: Visual inspection Wetting of wire surface by new solder 90%, free-flowing solder Please read Cautions and warnings and Important notes at the end of this document. Page 31 of 41 B32674 ... B32678 MKP DC link high power series 1.2 Resistance to soldering heat Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1A. Conditions: Series Solder bath temperature Soldering time MKT boxed (except 2.5 x 6.5 x 7.2 mm) 260 5 C coated uncoated (lead spacing > 10 mm) MFP MKP (lead spacing > 7.5 mm) MKT boxed (case 2.5 x 6.5 x 7.2 mm) MKP (lead spacing 7.5 mm) MKT uncoated (lead spacing 10 mm) insulated (B32559) 10 1 s 5 1 s <4s recommended soldering profile for MKT uncoated (lead spacing 10 mm) and insulated (B32559) Immersion depth 2.0 +0/0.5 mm from capacitor body or seating plane Shield Heat-absorbing board, (1.5 0.5) mm thick, between capacitor body and liquid solder Evaluation criteria: Visual inspection C/C0 tan Please read Cautions and warnings and Important notes at the end of this document. No visible damage 2% for MKT/MKP/MFP 5% for EMI suppression capacitors As specified in sectional specification Page 32 of 41 B32674 ... B32678 MKP DC link high power series 1.3 General notes on soldering Permissible heat exposure loads on film capacitors are primarily characterized by the upper category temperature Tmax. Long exposure to temperatures above this type-related temperature limit can lead to changes in the plastic dielectric and thus change irreversibly a capacitor's electrical characteristics. For short exposures (as in practical soldering processes) the heat load (and thus the possible effects on a capacitor) will also depend on other factors like: Pre-heating temperature and time Forced cooling immediately after soldering Terminal characteristics: diameter, length, thermal resistance, special configurations (e.g. crimping) Height of capacitor above solder bath Shadowing by neighboring components Additional heating due to heat dissipation by neighboring components Use of solder-resist coatings The overheating associated with some of these factors can usually be reduced by suitable countermeasures. For example, if a pre-heating step cannot be avoided, an additional or reinforced cooling process may possibly have to be included. EPCOS recommendations As a reference, the recommended wave soldering profile for our film capacitors is as follows: Please read Cautions and warnings and Important notes at the end of this document. Page 33 of 41 B32674 ... B32678 MKP DC link high power series Body temperature should follow the description below: MKP capacitor During pre-heating: Tp 110 C During soldering: Ts 120 C, ts 45 s MKT capacitor During pre-heating: Tp 125 C During soldering: Ts 160 C, ts 45 s When SMD components are used together with leaded ones, the film capacitors should not pass into the SMD adhesive curing oven. The leaded components should be assembled after the SMD curing step. Leaded film capacitors are not suitable for reflow soldering. In order to ensure proper conditions for manual or selective soldering, the body temperature of the capacitor (Ts) must be 120 C. One recommended condition for manual soldering is that the tip of the soldering iron should be < 360 C and the soldering contact time should be no longer than 3 seconds. For uncoated MKT capacitors with lead spacings 10 mm (B32560/B32561) the following measures are recommended: pre-heating to not more than 110 C in the preheater phase rapid cooling after soldering Please refer to EPCOS Film Capacitor Data Book in case more details are needed. Please read Cautions and warnings and Important notes at the end of this document. Page 34 of 41 B32674 ... B32678 MKP DC link high power series Cautions and warnings Do not exceed the upper category temperature (UCT). Do not apply any mechanical stress to the capacitor terminals. Avoid any compressive, tensile or flexural stress. Do not move the capacitor after it has been soldered to the PC board. Do not pick up the PC board by the soldered capacitor. Do not place the capacitor on a PC board whose PTH hole spacing differs from the specified lead spacing. Do not exceed the specified time or temperature limits during soldering. Avoid external energy inputs, such as fire or electricity. Avoid overload of the capacitors. The table below summarizes the safety instructions that must always be observed. A detailed description can be found in the relevant sections of the chapters "General technical information" and "Mounting guidelines". Topic Storage conditions Flammability Resistance to vibration Safety information Reference chapter "General technical information" Make sure that capacitors are stored within the specified 4.5 range of time, temperature and humidity conditions. "Storage conditions" Avoid external energy, such as fire or electricity (passive 5.3 flammability), avoid overload of the capacitors (active "Flammability" flammability) and consider the flammability of materials. Do not exceed the tested ability to withstand vibration. 5.2 The capacitors are tested to IEC 60068-2-6. "Resistance to EPCOS offers film capacitors specially designed for vibration" operation under more severe vibration regimes such as those found in automotive applications. Consult our catalog "Film Capacitors for Automotive Electronics". Topic Safety information Soldering Do not exceed the specified time or temperature limits during soldering. Use only suitable solvents for cleaning capacitors. When embedding finished circuit assemblies in plastic resins, chemical and thermal influences must be taken into account. Caution: Consult us first, if you also wish to embed other uncoated component types! Cleaning Embedding of capacitors in finished assemblies Please read Cautions and warnings and Important notes at the end of this document. Page 35 of 41 Reference chapter "Mounting guidelines" 1 "Soldering" 2 "Cleaning" 3 "Embedding of capacitors in finished assemblies" B32674 ... B32678 MKP DC link high power series Display of ordering codes for EPCOS products The ordering code for one and the same product can be represented differently in data sheets, data books, other publications and the website of EPCOS, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.epcos.com/orderingcodes. Please read Cautions and warnings and Important notes at the end of this document. Page 36 of 41 B32674 ... B32678 MKP DC link high power series Symbols and terms Symbol C A C C CR C C/C C/CR dt t T tan V dV/dt V/t E ESL ESR f f1 f2 fr FD FT i IC English Heat transfer coefficient Temperature coefficient of capacitance Capacitor surface area Humidity coefficient of capacitance Capacitance Rated capacitance Absolute capacitance change Relative capacitance change (relative deviation of actual value) Capacitance tolerance (relative deviation from rated capacitance) Time differential Time interval Absolute temperature change (self-heating) Absolute change of dissipation factor Absolute voltage change Time differential of voltage function (rate of voltage rise) Voltage change per time interval Activation energy for diffusion Self-inductance Equivalent series resistance Frequency Frequency limit for reducing permissible AC voltage due to thermal limits German Warmeubergangszahl Temperaturkoeffizient der Kapazitat Kondensatoroberflache Feuchtekoeffizient der Kapazitat Kapazitat Nennkapazitat Absolute Kapazitatsanderung Relative Kapazitatsanderung (relative Abweichung vom Ist-Wert) Kapazitatstoleranz (relative Abweichung vom Nennwert) Differentielle Zeit Zeitintervall Absolute Temperaturanderung (Selbsterwarmung) Absolute Anderung des Verlustfaktors Absolute Spannungsanderung Differentielle Spannungsanderung (Spannungsflankensteilheit) Spannungsanderung pro Zeitintervall Aktivierungsenergie zur Diffusion Eigeninduktivitat Ersatz-Serienwiderstand Frequenz Grenzfrequenz fur thermisch bedingte Reduzierung der zulassigen Wechselspannung Frequency limit for reducing permissible Grenzfrequenz fur strombedingte AC voltage due to current limit Reduzierung der zulassigen Wechselspannung Resonant frequency Resonanzfrequenz Thermal acceleration factor for diffusion Therm. Beschleunigungsfaktor zur Diffusion Derating factor Deratingfaktor Current (peak) Stromspitze Category current (max. continuous Kategoriestrom (max. Dauerstrom) current) Please read Cautions and warnings and Important notes at the end of this document. Page 37 of 41 B32674 ... B32678 MKP DC link high power series Symbol IRMS iz k0 LS 0 test Pdiss Pgen Q R R Ri Rins RP RS S t T tan tan D tan P tan S TA Tmax Tmin tOL Top TR Tref tSL English (Sinusoidal) alternating current, root-mean-square value Capacitance drift Pulse characteristic Series inductance Failure rate Constant failure rate during useful service life Failure rate, determined by tests Dissipated power Generated power Heat energy Density of water vapor in air Universal molar constant for gases Ohmic resistance of discharge circuit Internal resistance Insulation resistance Parallel resistance Series resistance severity (humidity test) Time Temperature Time constant Dissipation factor Dielectric component of dissipation factor Parallel component of dissipation factor Series component of dissipation factor Temperature of the air surrounding the component Upper category temperature Lower category temperature Operating life at operating temperature and voltage Operating temperature, TA + T Rated temperature Reference temperature Reference service life Please read Cautions and warnings and Important notes at the end of this document. German (Sinusformiger) Wechselstrom Inkonstanz der Kapazitat Impulskennwert Serieninduktivitat Ausfallrate Konstante Ausfallrate in der Nutzungsphase Experimentell ermittelte Ausfallrate Abgegebene Verlustleistung Erzeugte Verlustleistung Warmeenergie Dichte von Wasserdampf in Luft Allg. Molarkonstante fur Gas Ohmscher Widerstand des Entladekreises Innenwiderstand Isolationswiderstand Parallelwiderstand Serienwiderstand Scharfegrad (Feuchtetest) Zeit Temperatur Zeitkonstante Verlustfaktor Dielektrischer Anteil des Verlustfaktors Parallelanteil des Verlfustfaktors Serienanteil des Verlustfaktors Temperatur der Luft, die das Bauteil umgibt Obere Kategorietemperatur Untere Kategorietemperatur Betriebszeit bei Betriebstemperatur und -spannung Beriebstemperatur, TA + T Nenntemperatur Referenztemperatur Referenz-Lebensdauer Page 38 of 41 B32674 ... B32678 MKP DC link high power series Symbol VAC VC VC,RMS English AC voltage Category voltage Category AC voltage VCD Vch VDC VFB Vi Vo Vop Vp Vpp VR Corona-discharge onset voltage Charging voltage DC voltage Fly-back capacitor voltage Input voltage Output voltage Operating voltage Peak pulse voltage Peak-to-peak voltage Impedance Rated voltage Amplitude of rated AC voltage R VRMS German Wechselspannung Kategoriespannung (Sinusformige) Kategorie-Wechselspannung Teilentlade-Einsatzspannung Ladespannung Gleichspannung Spannung (Flyback) Eingangsspannung Ausgangssspannung Betriebsspannung Impuls-Spitzenspannung Spannungshub Nennspannung Amplitude der Nenn-Wechselspannung VSC Vsn (Sinusoidal) alternating voltage, root-mean-square value S-correction voltage Snubber capacitor voltage Z Impedance Spannung bei Anwendung "S-correction" Spannung bei Anwendung "Beschaltung" Scheinwiderstand Lead spacing Rasterma Please read Cautions and warnings and Important notes at the end of this document. (Sinusformige) Wechselspannung Page 39 of 41 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). Page 40 of 41 Important notes 7. The trade names EPCOS, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 41 of 41