T3DMM4-5 Data Sheet 4.5 Digit Digital Multimeter Broad Measurement Range DC: 1000 Volts AC: 750 Volts Current: 10A Tools for Improved Debugging Wide range of measurements - DC/AC voltage and Current, Resistance, Capacitance, Frequency, Period, Temperature, and more. More application coverage from a single Digital multimeter. True-RMS measurements - All AC Voltage and Current ranges give True-RMS readings. Excellent accuracy regardless of the waveform shape. Advanced measurement features - Min, Max, Average, Standard Deviation dBm/dB, Pass/fail, Histogram, Trend, Relative measurements. Advanced features for today's measurement needs. Built-in cold terminal thermocouple compensation - 4.3 inch (10.92 cm) color TFT-LCD 480 x 272 display. Accurate Temperature measurements. USB Device, USB Host and LAN support Remote control your measurements. Key Specifications DC Voltage 600 mV to 1000 V DC Current 600 A to 10 A True RMS AC Voltage 600 mV to 750 V True RMS AC Current 60 mA to 10 A 2/ 4 Wire Resistance 600 Ohms to 100 MOhms Connectivity USB Device, LAN Remote Control SCPI, LabView Driver PRODUCT OVERVIEW Teledyne Test Tools T3DMM4-5 is a 41/2 digit digital multimeter incorporating the latest 4.3 inch (10.92cm) dualdisplay technology which can be configured to show data histograms, Data fluctuation Trends, Bar Graph, Statistics or the traditional Number mode, all in an easy to use interface. A great feature of the Teledyne Test Tools T3DMM4-5 is it's ability to made highly accurate True RMS AC Voltage and Current measurements, meaning no loss of accuracy even when measuring complex voltage and current waveforms. The T3DMM4-5 is especially well suited for the needs of the general purpose multifunctional environment, as well as supporting a full range of automatic measurements. Main Functions Application fields Basic Measurement Function Research DC Voltage: 600 mV ~ 1000 V Development DC Current: 600 A ~ 10 A Detection AC Voltage: True-RMS, 600 mV ~ 750 V Calibration AC Current: True-RMS, 60 mA ~ 10 A Automatic 2/4-Wire Continuity 2 nF ~ 10000 F Test: Range is fixed at 2 k Test: Adjustable range is 0 ~ 4 V. Frequency Period Measurement: 20 Hz ~ 500 KHz Measurement: 2 s ~ 0.05 s Temperature: Support for TC and RTD sensor Max, Min, Average, Standard Deviation, dBm/dB, Relative Measurement, Pass/Fail Histogram, Trend Chart User-friendly Design 4.3" TFT-LCD, 480*272 Dual display, Chinese and English Menu Built-in File 2 Laboratory and Maintenance Laboratory Production Test Resistance: 600 ~ 100 M Capacitance: Diode Laboratory front panel accessible help system management (support for U-disc and local storage) Main Features Real Up 41/2 digit (66000 count) readings resolution to 150 rdgs/s measurement speed True-RMS AC Voltage and AC Current measuring 1 Gb flash memory for mass storage configuration files and data files Built-in cold terminal compensation for thermocouple Standard USB interface: USB Device, USB Host, LAN & LAN remote interfaces support common SCPI command set. Compatible with other popular DMMs on the market. SPECIAL FEATURES Dual Display Bar Chart Statistics Histogram Trend Chart Hold Measurement dBm Hold Measurement Interface 3 SPECIFICATIONS DC Characteristic Function DC Voltage DC Current Resistance3) Diode Test6) Continuity Test Accuracy (%of Reading + count)1) Range2) 600 mV 6V 60 V 600 V 1000 V4) 600 A 6 mA 60 mA 600 mA 6A 10 A5) 600 6 K 60 K 600 K 6 M 60 M 100 M 0~2 V 2~4 V 2000 Test current or Load voltage < 33 mV < 330 mV < 0.05 V < 0.5 V < 0.33 V < 0.6 V 1 mA 1 00 A 10 A 1 A 200 nA 200 nA || 10 M 200 nA || 10 M 1 mA 1 mA 1 mA Resolution 0.01 mV 0.0001 V 0.001 V 0.01 V 0.1 V 0.01 A 0.0001 mA 0.001 mA 0.01 mA 0.0001 A 0.001 A 0.01 0.0001 K 0.001 K 0.01 K 0.0001 M 0.001 M 0.01 M 0.0001 V 0.0001 V 0.1 Accuracy (one year; 23C 5C) 0.02 + 6 0.02 + 6 0.02 + 6 0.02 + 6 0.02 + 6 0.05 + 3 0.05 + 3 0.05 + 3 0.12 + 6 0.20 + 5 0.25 + 4 0.08 + 6 0.04 + 6 0.04 + 6 0.08 + 6 0.12 + 3 0.85 + 3 1.75 + 3 0.05 + 3 0.35 + 3 0.05 + 3 Remarks: 1) Specifications are after 0.5 Hour warm-up, "Slow" measurement rate and calibration temperature 18C ~ 28C. 2) 10 %over range on all ranges except for DCV 1000 V, ACV 750 V, DCI 10 A and ACI 10 A. 3) Specifications are for 4-wire measure or 2-wire measure under "REF" operation. 0.2 of extra errors will be generated if perform 2-wire measure without "REF" operation. 4) Plus 0.02 mV of error per 1 V after the first 500 VDC. 5) 30 seconds OFF after 30 seconds ON is recommend for continuous current that higher than DC 7 A or AC RMS 7 A. 6) Accuracy specifications are only for voltage measuring at input terminal. The typical value of current under measure is 1 mA. Voltage drop at diode junction may vary with current supply. Adjustable voltage range: 0 ~ 4 V. 4 SPECIFICATIONS AC Characteristic Function Accuracy (%of Reading + count)1) Range2) 600 mV 6V True-RMS AC Voltage3) 60 V 600 V 750 V 60 mA 600 mA True-RMS AC Current5) 6A 10 A6) Frequency Range Resolution 20 Hz - 45 Hz 45 Hz - 100 Hz 100 Hz - 20 KHz 20 KHz - 50 KHz 50 KHz -100 KHz 20 Hz - 45 Hz 45 Hz - 100 Hz 100 Hz - 20 KHz 20 KHz - 50 KHz 50 KHz -100 KHz 20 Hz - 45 Hz 45 Hz - 100 Hz 100 Hz - 20 KHz 20 KHz - 50 KHz 50 KHz -100 KHz 20 Hz - 45 Hz 45 Hz - 100 Hz 100 Hz - 20 KHz 20 KHz - 50 KHz 50 KHz -100 KHz 20 Hz - 45 Hz 45 Hz - 100 Hz[4] 100 Hz - 20 KHz 20 KHz - 50 KHz 50 KHz -100 KHz 20 Hz - 45 Hz 45 Hz - 2 KHz 2 KHz - 10 KHz 20 Hz - 45 Hz 45 Hz - 2 KHz 2 KHz - 10 KHz 20 Hz - 45 Hz 45 Hz - 2 KHz 2 KHz - 10 KHz 20 Hz - 45 Hz 45 Hz - 2 KHz 2 KHz - 10 KHz 0.01 mV 0.01 mV 0.01 mV 0.01 mV 0.01 mV 0.0001 V 0.0001 V 0.0001 V 0.0001 V 0.0001 V 0.001 V 0.001 V 0.001 V 0.001 V 0.001 V 0.01 V 0.01 V 0.01 V 0.01 V 0.01 V 0.01 V 0.01 V 0.01 V 0.01 V 0.01 V 0.001 mA 0.001 mA 0.001 mA 0.01 mA 0.01 mA 0.01 mA 0.0001 A 0.0001 A 0.0001 A 0.001 A 0.001 A 0.001 A Accuracy (one year; 23C 5C) 2.0 + 20 0.6 + 10 0.3 + 20 2.0 + 40 3.0 + 10 2.0 + 20 0.6 + 10 0.8 + 20 2.0 + 40 3.0 + 40 2.0 + 20 0.6 + 10 0.8 + 20 2.0 + 40 3.0 + 40 2.0 + 20 0.6 + 10 0.8 + 20 2.0 + 40 3.0 + 40 2.0 + 20 0.6 + 10 0.8 + 20 2.0 + 40 3.0 + 40 2.0 + 20 0.5 + 20 2.5 + 30 2.0 + 20 0.5 + 20 2.5 + 30 2.0 + 20 0.5 + 20 2.5 + 20 1.5 + 45 0.5 + 35 2.5 + 25 Additional wave crest factor error (not Sine)7) Wave crest coefficient 1 - 2 2 - 3 Error (% Range) 0.05 0.3 Remarks: 1) Specifications are for 0.5 Hour warm-up, "Slow" measurement rate and calibration temperature 18C ~ 28C. 2) 10 %over range on all ranges except for DCV 1000 V, ACV 750 V, DCI 10 A and ACI 10 A. 3) Specifications are for amplitude of sine wave input > 5 %of range. For inputs from 1%to 5 %of range and <50 kHz, add 0.1%of range as extra error. For 50 kHz to 100 kHz, add 0.1%of range as extra error. 4) Plus 0.025 V of error per 1 V after the first 400 VAC. 5) Specifications are for sine wave input > 5 %of range. 0.1%error will be added when the range of the input sine wave is 1%to 5 %. 6) 30 seconds OFF/ 30 seconds ON is recommend for the continuous current higher than DC 7 A or AC RMS 7 A. 7) For input Frequency Range < 100 Hz 5 SPECIFICATIONS Frequency and Period Characteristic Function Frequency/Period Accuracy (%of Reading + count)1) Range Frequency Range 600 mV to 750 V2) 20 Hz - 2 KHz 2 KHz - 20 KHz 20 KHz - 200 KHz 200 KHz -500 KHz Resolution Accuracy (one year; 23C 5C) 0.01 + 3 0.01 + 2 0.01 + 2 0.01 + 2 Remarks: 1) Specifications are for 0.5 Hour warm-up. 2) Except for exceptional levels, the AC input voltage is 5 %to 110 %of range when <100 kHz and 10 %to 110 %of range when >100 kHz. 750 V range is limited to 750 Vrms. The accuracy is 10 times %of Reading when the measurement range of AC voltage is in 600 mV range. Capacitance Characteristic Accuracy (%of Reading + count)1) Function Range2) Max Testing Current Resolution Capacitance 2 nF 20 nF 200 nF 2 F 20 F 200 F 10000 F 10 A 10 A 100 A 100 A 1 mA 1 mA 1 mA 0.001 nF 0.01 nF 0.1 nF 0.001 F 0.01 F 0.1 F 1 F Accuracy (one year; 23C 5C) 3 + 10 1 + 10 1+9 1 + 10 1 + 10 1+9 2 + 50 Remarks: 1) Specifications are for 0.5 Hour warm-up and "REF" operation. Using of non-film capacitor may generate additional errors. 2) Specifications are for from 1%to 110 %on 2 nF range and ranges from 10 %to 110 %on other ranges. Temperature Characteristic Function Probe Type RTD2) Temperature TC3) Accuracy (%of Reading + count)1) Probe Mode l = 0.00385 B E J K N R S T Working Temperature Range Accuracy (one year; 23C 5C) -200C ~ 660C 0C ~ 1820C -270C ~ 1000C -210C ~ 1200C -270C ~ 1370C -270C ~ 1300C -50C ~ 1760C -50C ~ 1760C -270C ~ 400C 0.16 0.76 0.5 0.5 0.5 0.5 0.5 0.6 0.5 Remarks: 1) Specifications are for 0.5 Hour warm-up, not include probe error. 2) Specifications are for 4-wire measure or 2-wire measure under "REF" operation. 3) Built-in cold terminal compensation for thermocouple, accuracy is 2C. 6 Temperature coefficient 0C ~ 18C 28C ~ 50C 0.09 0.14 0.02 0.02 0.03 0.04 0.09 0.11 0.03 MEASURING METHOD AND OTHER CHARACTERISTICS DC Voltage Input Resistance Input Bias Current Input Protection CMRR NMRR 600 mV 10 M or 10 G selectable 6 V, 60 V, 600 V and 1000 V Range 10 M 2 % < 90 pA, 25C 1000 V on all ranges 120 dB (For the 1 K unbalanced resistance in LO lead, max 500 VDC) 60 dB at "slow" measurement rate Resistance Testing Method Input Protection 4-wire resistance or 2-wire resistance selectable 1000 V on all ranges DC Current Shunt Resistor Input Protection 600 A sampling voltage < 33 mV 6 mA sampling voltage < 0.33 V 1 for 60 mA, 1 for 600 mA 0.01 for 6 A, 10 A Rear panel: accessible 10 A, 250 V fast-melt fuse Internal: 12 A, 250 V slow-melt fuse Continuity/Diode Test Measurement Method Beeper Continuity Threshold Input Protection 1 mA 5 %constant-current source or open-circuit voltage yes Adjustable 1000 V True-RMS AC Voltage Measurement Method Wave Crest Factor Input Impedance AC Filter Bandwidth CMRR AC Coupled true RMS measure - up to 1000 V DC bias are permitted on every range. 3 at full scale 1 M 2 %in parallel with < 100 pF on all ranges 20 Hz ~ 100 KHz 60 dB (For the 1 K imbalance resistance among Lo lead and < 60 Hz, Max 500 VDC) True-RMS AC Current Measurement Method Wave Crest Factor Max Input Shunt Resistor Input Protection DC Coupled to the fuse and shunt; AC Coupled True-RMS measurement (measures the AC components only) 3 at full scale < 10 A (include DC component) 1 for 60 mA, 600 mA; 0.01 for 6 A, 10 A Rear panel: accessible 10 A, 250 V fast-melt fuse Internal: 12 A, 250 V slow-melt fuse Frequency/Period Measurement Method Additional Errors Reciprocal-counting technique, AC Coupled input, AC voltage or AC current measurement function Percentage Error increases in all frequency counters when measuring low voltage or low frequency signal. Capacitance Measuring Measurement Method Connection Type Input Protection Measure the rate of change of voltage generated during the current flowing in the capacitor 2-wire 1000 V on all ranges 7 MEASURING METHOD AND OTHER CHARACTERISTICS Temperature Measuring Measurement Method Support for TC and RTD types of sensor Trigger and Memory Samples/Trigger Trigger Delay External Trigger Input VMC 1 ~ 10000 6 ms ~ 10000 ms optional Input Level Trigger Condition Input Impedance Level Output Polarity Output Impedance TTL compatible (High level when left input terminal is Disconnected Rising and Falling selectable 20 K//400 pF, DC-coupled TTL compatible Straight and negative optional 200 , typical History Records Volatile Memory Nonvolatile Memory 10 K reading of history records 1 Gb Nand Flash, Mass storage configuration for files and data files, Support U-disk external storage Math Functions Min/Max/Average, dBm, dB, Pass/Fail, Relative, Standard deviation, Hold, histogram, Trend chart, Bar chart General Specifications Power Supply AC 100 V ~ 120 V AC 200 V ~ 240 V Consumption Mechanism Dimension Weight Other Characteristics Display Screen Operating Environment electromagnetic compatibility Safety Remote Interface Programmer Language Warm Up Time 8 45 Hz ~ 66 Hz 45 Hz ~ 66 Hz 20 VA max 293.75 mm x 260.27 mm x 107.21 mm 3.76 Kg 4.3" TFT-LCD with aresolution of 480*272 Full accuracy from 0C to 50C, 80 %RH and 40C, non condensing Storage Temperature: -20C -70C Shock and Vibration: conforming to MIL-T-28800E, , 5 level (only for sine) Height above sea level: up to 3000 meters Conforming to EMC (2004/108/EC) and EN 61326-1:2013 Conforming to EN61010-1:2010 and low voltage instructions (2006/95/EC) 10/100 Mbit LAN, USB2.0 Full Speed Device and Host Standard SCPI, compatible with commands of main stream multimeters 30 minutes Ordering information Product Name Model Standard Accessories Teledyne Test Tools T3DMM4-5 Digital Multimeter T3DMM4-5 Two Test Leads, Two Alligator Clips A USB Cable A Quick Start A Guarantee Card Power Cord The T3DMM4-5 comes with a 3 year return to Teledyne LeCroy warranty. 9 ABOUT TELEDYNE TEST TOOLS Company Profile Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively. Oscilloscopes are tools used by designers and engineers to measure and analyze complex electronic signals in order to develop high-performance systems and to validate electronic designs in order to improve time to market. The Teledyne Test Tools brand extends the Teledyne LeCroy product portfolio with a comprehensive range of test equipment solutions. This new range of products delivers a broad range of quality test solutions that enable engineers to rapidly validate product and design and reduce time-tomarket. Designers, engineers and educators rely on Teledyne Test Tools solutions to meet their most challenging needs for testing, education and electronics validation. Location and Facilities Headquartered in Chestnut Ridge, New York, Teledyne Test Tools and Teledyne LeCroy has sales, service and development subsidiaries in the US and throughout Europe and Asia. Teledyne Test Tools and Teledyne LeCroy products are employed across a wide variety of industries, including semiconductor, computer, consumer electronics, education, military/aerospace, automotive/industrial, and telecommunications. Teledyne LeCroy (US Headquarters) 700 Chestnut Ridge Road Chestnut Ridge, NY. USA 10977-6499 Phone: 800-553-2769 or 845-425-2000 Fax Sales: 845-578-5985 Phone Support: 1-800-553-2769 Email Sales: contact.corp@teledynelecroy.com Email Support: support@teledynelecroy.com Web Site: http://teledynelecroy.com/ Teledyne LeCroy (European Headquarters) Teledyne LeCroy GmbH Im Breitspiel 11c D-69126 Heidelberg, Germany Distributed by: Phone: Fax: Phone Service: Phone Support: Email Sales: Email Service: Email Support: Web Site: +49 6221 82700 +49 6221 834655 +49 6221 8270 85 +49 6221 8270 28 contact.gmbh@teledynelecroy.com service.gmbh@teledynelecroy.com tlc.t3.appsupport.eu@teledyne.com http://teledynelecroy.com/germany teledynelecroy.com (c) 2018 Teledyne Test Tools is a brand and trademark of Teledyne LeCroy Inc. All rights reserved. Specifications,prices,availability and delivery subject to change without notice. Product brand or brand names are trademarks or requested trademarks of their respective holders. T3 stands for Teledyne Test Tools. 9Apr2019