www.tracopower.com Page 4 of 9
AC/DC Power Modules
TMP & TMPM Series 4 to 60 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
General Specifications
Temperature ranges – Operating TMPM 04 models: –25°C to +60°C (no derating)
TMP 10 models: –25°C to +50°C (no derating)
other models: –25°C to +70°C (with derating)
– Storage (non-operating) –40°C to +85°C
Power derating 3.3 %/K above +50°C to +65°C
5.0 %/K above +65°C to +70°C
(no derating approved for TMPM04 and TMP10 models)
Over temperature protection at 90°C (automatic recovery at 67°C)
Temperature coefficient 0.02 %/K
Humidity (non-condensing) 95 % rel. H max.
Switching frequency 100 kHz typ. fixed
Isolation voltage (60 sec.) – Input/Output 3‘000 VAC
Isolation resistance – Input/Output 100 MOhm (at 500 VDC)
Working voltage (rated) 250 VAC
Altitude during operation TMP 10, TMPM 04 & 10, : 2‘000 m max. (6’560 ft) approved
other models: 3‘000 m max. (9‘840 ft) approved
Electromagnetic compatibility (EMC), Emissions EN 61000-6-3
EN 61000-6-4
EN 61204-3: 2000, class A
EN 55011, EN 55032, FCC part 15: class B
Electromagnetic compatibility (EMC), Immunity EN 61000-6-2: 2005
EN 61204-3: 2000, class A
– Electrostatic discharge ESD EN 61000-4-2 8 kV / 4 kV, criteria B
– RF field susceptibility EN 61000-4-3 10 V/m, criteria A
– Electrical fast transient / burst immunity input EN 61000-4-4 ±2 kV, criteria B
– Electrical fast transient / burst immunity output EN 61000-4-4 ±2 kV, criteria B
– Surge immunity line – neutral EN 61000-4-5, ±1 kV, criteria B
– Surge immunity output EN 61000-4-5 ±0.5 kV, criteria B
– Immunity to conducted RF disturbances EN 61000-4-6 10 V, criteria B
– Mains voltage dips and interruptions EN 61000-4-11 30 % 10 ms, criteria B
60 % 100 ms, criteria C
95 % 5000 ms, criteria C
EMC test certificates www.tracopower.com/overview/tmp
Protection class II
to IEC/EN 60536
Safety standards – Information technology equipment
IEC/EN 60950-1, UL 60950-1
TMP 30 models: IEC/EN 62368-1, UL 62368-1
– Industrial control equipment
UL/cUL 508
(chassis mount single and symetric
dual output models only)
Safety approvals – CB certificate for IEC 60950-1 www.tracopower.com/overview/tmp
– UL approvals for UL 60950-1 www.ul.com -> certifications -> File: e188913
– UL approval for UL 508 (chassis mount models only) www.ul.com -> certifications ->
File: e322109
Reliability /calculated MTBF TMP 07, TMPM 04 & 10 models: >330‘000 h
(MIL-HDBK-217F, at +25°C, ground benign) TMP 10 models: >300‘000 h
TMP 15 models: >280‘000 h
TMP 30 models: >250‘000 h
TMP 60 models: >125‘000 h
Casing material plastic resin + fiberglass (UL 94V-0 rated)
Environmental compliance – Reach
www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU